Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 CrAdmitted-Finance | -14.99% | ₹2.3 Cr | L1 | Admitted-Finance |
| 2 | L1₹2.3 CrAdmitted-Finance | -14.99% | ₹2.3 Cr | L1 | Admitted-Finance |
| 3 | L1₹2.3 CrAdmitted-Finance QTR NO 2R 31 RIE CAMPUS WARD NO 28 UNIT IX PO SAHEED NAGAR BHUBANESWAR 751022 | KHORDHA | ODISHA | 751022 | -14.99% | ₹2.3 Cr | L1 | Admitted-Finance |
| 4 | L1₹2.3 CrAdmitted-Finance | -14.99% | ₹2.3 Cr | L1 | Admitted-Finance |
| 5 | L1₹2.3 CrAdmitted-Finance AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | -14.99% | ₹2.3 Cr | L1 | Admitted-Finance |
Tender Value
₹2.7 Cr
EMD Value
₹2.7 L
Closing Date
29 Dec 2025, 5:30 pmClosed
CCE Cuttack RandB Circle
O/o CCE Cuttack RandB Circle
Building work
2025_EICCL_123481_1
CCE.Ctc.(RandB)10/2025-26
National Competitive Bid
Civil Works - Buildings
270 days
Cuttack
As per DTCN
3 documents required · 3 mandatory
₹10,000
₹2.7 L
Yes
5 Feb 2026
18 Dec 2025
30 Dec 2025
18 Dec 2025
29 Dec 2025
18 Dec 2025
Supplying, filling in foundation and plinth with good quality river sand with watering and ramming including cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
Filling foundation and plinth with excavated earth well water and rammed in layers not exceeding 23cm in depth with all leads and lifts including cost conveyance taxes cost of all materials and labour etc complete as per specification and direction of Engineer in charge
Providing & laying plain Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
Providing & laying plain Cement concrete (1:2:4) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.
Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge. (Ground floor)
1st floor
Head room
Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:4) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge. (Ground floor)
1st floor
Head room
RCC work of M-20 with 20mm and down graded size crushed stone aggregates mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge.Column base footing
Plinth Beam
Column in superstructure -Ground floor
1st floor
Head room
Lintel-Ground floor
1st floor
Chajja-Ground floor
1st floor
Shelves Ground floor
1st floor
Roof slab -Ground floor
1st floor
Head room
Staircase -Ground floor
1st floor
Roof Beam Ground floor
1st floor
Head room
Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge Ground floor
1st floor
Head room
Providing 16 mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
1st floor
Head room
Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
1st floor
Head room
Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside ceiling surface of roof slab after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties of materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
1st floor
Head room
Supplying, fitting and fixing of Vitrified Industrial tiles in floors of size (600x600mm) (Plain/Ivory) over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF
1st floor
Supplying, fitting and fixing of Vitrified tiles in floors of size (600x600mm) (Plain/Ivory) over 20mm thick bed of cement mortar(1:4) jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royalties of materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF
1st floor
1st floor
CIVIL WORKS - Earth work in excavation of foundation in all kinds soil including dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and direction of Engineer in charge
1st floor
Painting two coats with anti-fungal resistance Weather Seal Coat over a coat of primer of approved shade upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge Ground floor
1st floor
Head room
Painting two coats with a coat of approved Plastic Emulsion paint over a coat of primer including sand papering, polishing the surface, cost, conveyances of materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge .Ground floor
1st floor
Head room
Painting two coats with approved Synthetic enamel paint over a coaat of primer of approved colour, shade over a coat of red oxide primer in Iron work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge. Ground floor
1st floor
Supplying, fitting & fixing in all floors of M.S. Grill in doors and windows with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of labour, materials cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardward required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost .
Providing, Fitting & Fixing of Stainless steel of 304 grade in handrailing of 50mm dia of 2mm thick circular pipe with balustrade of size 32mmX32mm X2mm @ 0.90mtr. C/C and stainless square pipes bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance of Materials, Labour, TandP etc required for the complete in all respect and as per specification & direction of Engineer-in-charge
PH works- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes conforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Joints all complete as per specification and direction of the Engineer in charge. 20mm dia CPVC pipe In ground floor
Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and ,es of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment)
EI works- Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Light Point GROUP-A
Light Point GROUP-B
Light Point GROUP-C
Fan Point GROUP-B
Fan Point GROUP-C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying ,fixing of 6A Plug on the same board in Separate switch board with complete fitting by 01 no of 6A switch & socket (modular type & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 2X 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Supplying,fixing of 1X1 6A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 01 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Supplying,fixing of 1X 6 A + 1 X1 6A Plug on the separate board with complete fitting by 01 No 6Amp & 01 no of 16A switch & socket(modular type) ( with suitable size modular box & metallic cover plate (both side)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of m
aterials.
Recessed Extra lead Sub-main wiring for light and fan point in 2x1.5mm2 FR PVC insulated single core multistrand copper conductor of ISI Marked confirming to IS-694/1990 in 20mm dia nonmetalic heavy duty conduit 1.6 sqmm thick along with 1x1.5 sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge(Make of wire Finolex / Havells /Polycab) 2x1.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990
Recessed wiring to Sub-main in 2x2.5 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x2.5 sqmm +1x1.5 sqmm 1100 Volts confirming to IS 694/1990
Recessed wiring to Sub-main in 2x4 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x1.5sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x4 sq mm+1x1.5 sqmm 1100 Volts confirming to IS 694/1990
Recessed wiring to Sub-main in 2x6 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 32mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x2.5sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x6 sq mm+1x2.5 sqmm 1100 Volts confirming to IS 694/1990
Recessed wiring to Sub-main in 2x10 sqmm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 32mm dia non metalic heavy duty flexible conduct 1.6mm thick along with 1x4sqmm FRLS PVC insulated single core multistrand copper conductor as earth wire as required complete in all respect as per direction of Engineer in charge (Make of wire Finolex / Havells /Polycab) 2x10 sq mm+1x4 sqmm 1100 Volts confirming to IS 694/1990
S/F of Bakelite Angle holder/Batten Holder of ISI marked in place of ceiling Rose complete in all respect as per direction of Engineer in charge (Make : Cona / Anchor / Havell's)
S/F of 8 way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard) )
S/F of 12 way SPN MCB DB on existgsurface / wall mounting with all connection complete in all respect as per direction of engineer incharge (Make : Schneider (ACTI 9 ) /legrand (Ekinox 3) /siemens (Betaguard) )
Supply and fixing of SP 6-32 A, 10 KA rating 240 V "C" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager )
Supply and fixing of RCCB DP 25 A rating 240V 30 MA breaker suitable for lighting and other loads in the existing DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager )
Supply and fixing of RCCB DP 63 A rating 240V 100 MA breaker suitable for lighting and other loads in the existing DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager )
S/F of 9 inch Heavy duty (Metalic Colour) Exahust Fan with wall cutting, S/F of proper size of hume pipe, concreating, plastaring, painting with all connection testing and commissioning complete in all respect as per direction of Engineer in charge (Make:- Almonard / Usha- S. PH Turbo/Crompton - Trans Air/Khaitan,/ Havells)
S/F of 18 inch Heavy duty (Metalic Colour) Exahust Fan with wall cutting, S/F of proper size of hume pipe, concreating, plastaring, painting with all connection testing and commissioning complete in all respect as per direction of Engineer in charge (Make:- Almonard / Usha- S. PH Turbo/Crompton - Trans Air/Khaitan,/ Havells)
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years..
S/F of Electronics step type Modular fan regulator with all connection complete in all respect as per direction of engineer incharge (Make: legrand (Mylinc)/schneider (clipsal)/hager (Insysta))
SITC of energy efficient LED tube light fittings with alluminium batten and LED tube light having power rating not more than 10 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
SITC of energy efficient LED tube light fittings with alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supplying and fixing of Energy efficient surface mounted square 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years.
SITC of energy efficien
t LED 90 watt Street light fittings complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supply of fixing of 40 mm GI Brackt with 2 nos GI clamp & 4 nos 3'' Anchor fasteners for fixing of street light.
Supply and fixing of DP 63A, 10 KA rating 240V / 415V "C" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager )
Supply and fixing of 2 pole 63 AMP changeover in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Apex/ Havells /Hager/L&T)
S/F of 63 - 100 A copper busbar panel of size 13x25x7 inch of 63-100 Amp FP MCB / MCCB AS INCOMER copper busbar, 415V 4 strip & internal connection & provision for termination of incomming & out going cable , earthing, Indicator etc, ( Floor panel)
Supply and fixing of FP 63A, 10 KA rating 415V "C" series miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager )
S/F of 63-100 A cubical panel board made of 16 SWG C.R sheet with powder coated with provision of following items with fabrication erection testing & comissioning of total enclosed panel board of size not less than 32"x32"x8" with (25 X 6 mm ) Double Busbar of 63-100A, 415V 4strip & internal connection & provision for termination of incomming & out going cable , earthing etc, complete with supply & fixing of following switch gears. 1. MFM 2. RYB Indicator 3. SPD 4. 63-100Amp 16 ka 4P MCCB , 5. 63A changeover earthing connector ,stand, Cable alley.
Supply and fixing of 4 pole MCCB 16-100A,Ics = 100% Icu, 16 KA breaking capacity, adjustableThermal,fixed magnetic type in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager)
Supply and fixing of Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) IEC 62053-21 complete with connections testing and commissioning complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager)
Supply and fixing of 4 pole (3P+N) ( T1+T2 - Iimp 8 kA/pole T2 - 60 kA) 40 KA SPD in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard) /Hager/ OBO )
Supply and fixing of 4 pole 63 AMP changeover in existing cubicle panel board including drilling holes in cubcle panel, making connections, etc. as required complete in all respect as per direction of Engineer in charge (Make : Schneider (ACTI 9 ) /legrand /siemens (Betaguard) /Hager/L&T)
Supply and fixing of G.I Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary with charcoal and salt as required.
Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit as required with all connection complete in all respect as per direction of engineer incharge
Solar Street Light:-Supply of Supply of All-In-One Solar LED Streetlight luminaire with System lumen output of 8500 lumens. System Efficacy should be ≥180lm/W. Maximum Power Consumption should be 47W/ 50 W. AIO luminaire should have minimum 75Wp Mono Solar Panel with 12.8V 30AH LiFePo4 Battery.ithium Ferrophosphate (LiFePo4) Battery (BIS approved) which shall be inside the extruded aluminium luminaire housing (Theft retardant type), Battery should have lifeclass of minimum 2000 cycles with inbuilt BMS system.CCT should be 5700K (+/-500K) and CRI should be ≥70. The luminaire shall be with PIR sensor.The complete system & BMS should be designed to provide 2 nights (24 Hrs) back up in dimming mode by activating PIR sensor and battery should be kept inside the luminaire and Mono Crystalline Panel (Made in India ) to be mounted on the top of the luminaire housing. The luminaire must be having IP 65 protection for critical component like (LED compartment, Driver compartment & Battery) . The AIO street light is having IK 08 protection except for panel .The luminaire should have the provision the tiltable/ adjustable mounting bracket to mount it on the top of the pole directly. Warranty on the AIO street lights must be 5 years . The solar lighting company must be having in house Lab accriditted by NABL , Lighting design team and service facility in Odisha to provide immediate after sales service within warranty period. LM79 report from 3rd party NABL accredited lab must be substantiating Lumen output and system Efficacy. TDS approval prior to start of the work. The System should meet below safety standards 1. IEC60598-2-3 : Safety of Luminaire for Road and Street Lighting 2. IEC 62109-1 : Safety of Power Converters used in solar Panel 3. EN 50530 : P
erformance Evaluation of Maximum Power Point(MPPT) 4. IEC 61547 : EMC immunity requirements 5. CISPR 15 : Radio disturbance characteristics 6. IEC 61730-1,2 & IEC 61215 : Safety of Solar Panel Module 7. IEC 62133 & UL1642 - Safety of Lithium Ferro Phosphate BatteryAll the test reports must be in the name of solar lighting company )Make- (Philips/Panasonic/Wipro/Havells/Bajaj/Crompton ) N.B:- The Cost includes 5 Years CMC including Repair/ Maintenance/ Replacement of the product in case of any defect.
Supply of 06 mtr high hot dip galvanised octagonal poles with 130 mm bottom A/F & 70mm top A/F made up of 4 mm thk. HT sheet along with base plate of size 200X200X12 mm thk. PCD - 200 mm with M20x6000mm “J” type foundation bolt(Make-Bajaj/LYSAGHT/VALMONT/Crompton/Utkarsh)
Foundation, erection and commissioning of street light pole and arm to proper alignment with supply of all materials such as steel reinforcement , metal, chips, cement , sand, cable entry pipe, shuttering for RCC work duly providing foundation bolt and nut with providing not less than 1m× 1m× 1.5m concrete(1:2:4) as per direction of field engineer during execution and approved drawings including labour charges, cost and conveyance of materials etc. complete.
Installation of 6 to 8 mtr pole after fixing the solar lights in the bracket & pole on that foundation by using suitable machinery by taking all safety precautions as per the direction of EIC.
10 KVA Rooftop Solar System:- Supply and Fixing of 590 w photovoltaic modules Solar Panel as per direction of Engineer in charge. (Make: RenewSys/ Luminous) Warranty: 25 years
Supply and Fixing of 10 KVA/120 V MPPT Solar PCU as per direction of Engineer in charge (Make: Statcon/ RenewSys/ Luminous) Warranty: 2 years
Supply and Fixing of of 200 Ah Solar Battery (Make: Exide / Luminous) Warranty: 5 years
Supply and fixing of GI module mounting structure with Accessories (Nut, Bolt, Anchor Bolt, C-clip, Conduit Pipe, PVC tape, Cable tie, MC4 Connector ,Civil Work and GI Battery Stand etc.) as per direction of Engineer in charge.
Supply of 2 in1 out DCDB with HRC Fuse, DC MCB and DC SPD as per direction of Engineer in charge.
Supply of 1 in1 out ACDB with AC MCB and AC SPD as per direction of Engineer in charge.
Supply & Laying of 4 sq. mm XLPE type Solar DC Cable as per direction of Engineer in charge. (Make-Polycab /Havells/KEI)
Supply & Laying of 16 sq. mm XLPE type Solar DC Cable as per direction of Engineer in charge. (Make-Polycab /Havells/KEI)
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn
Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 8 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 8 kg made up of frost resistant concrete. Make-OBO/Dehn
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn
Supply for Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU.Make-OBO/Dehn
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 Aluminium . Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). Make-OBO/Dehn
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn
Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn
Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
Per Watt
25mm dia C-PVC Pipe
32mm dia C-PVC Pipe
20mm dia C-PVC Pipe 1st floor
25mm dia C-PVC Pipe
32mm dia C-PVC Pipe
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 25mm dia PVC ASTM-D ( Sch-80)
32mm dia PVC ASTM (SCH-80) Pipe
40mm dia ASTM ( Sch-80 ) PVC Pipe
25mm dia PVC ASTM-D ( Sch-80) In 1st floor
50mm dia ASTM ( Sch-80 ) PVC Pipe In 2nd floor
Supplying all materials,labour,T&P and cutting holes through existing brick work including making good the damages in cement mortar(1:4) for taking GI pipes and fittings/PVC pipes and fittings etc.all complete as per PH specification and direction of the Engineer-in-charge. 250mm thick wall In ground floor
50mm dia ASTM ( Sch-80 ) PVC Pipe In 2nd floor
250mm thick wall In 1st floor
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge In ground floor
In first floor
Supplying all materials , labour, T&P and cutting grooves in pucca floors and walls for taking P.V.C pipes and G.I fittings etc. and making good the damages including finishing complete as per P.H. specification and direction of Engineer-in-charge. In ground floor
Supplying all materials , labour, T&P and fitting and fixing brass/CP fittings of following nominal bore with supply of all jointing materials complete as per P.H. specification and direction of Engineer-in-charge 15mm C.P.Bib cock(Plaza make/Amber /Aquatic make )
15mm C.P.Long Body Bib cock (Plaza make/Amber /Aquatic make )
15mm C.P.Two way Bib cock .(Plaza make/Amber /Aquatic make )
15mm dia CP Helth faucet.(Plaza make/Amber /Aquatic make )
15mm dia CP Angle Stop cock.(Plaza make/Amber /Aquatic make )
20mm dia CP Concealed Stop cock(Plaza make/Amber /Aquatic make )
25mm dia CPVC fullway valve(Shakti Make)
32mm dia CPVC fullway Vave (Shakti make)
40mm dia CPVC fullway valve(Shakti Make)
50mm dia CPVC fullway valve(Shakti Make)
15mm dia. C.P extension piece
15mm dia. C.P flange
125mm dia CP gratting
15mm C.P.Pillar cock(Plaza make/Amber /Aquatic make )
Supplying all materials ,labour ,T&P and fitting and fixing CP shower with 15mm or 20mm inlet including polishing etc.all complete as per specification and direction of Engineer-in-charge 15mm CP Revolving shower with shower Arm. (Plaza make/Amber /Aquatic make )
Supplying all materials ,labour ,T&P and fixing 10 litres capacity PVC low level flushing cistern with a pair of PVC brackets complete with fittings such as pvc siphonic arrangements, 15mm dia nominal size pvc ball valve with polythene float ,pvc handles, unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet , and connecting the inlet pipe with supply main etc.all complete as per specification and direction of Engineer-in-charge 10 ltrs. capacity PVC L.L cistern (Slimline- Deluxe-white-Parryware)
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge On the2nd floor 2000litre capacity water storage tanks
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm 2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm
DOL Control panel
40mm dia steel short piece
Well cap
50mm size CI bracket
2.50sqmm flat cable
20mm dia rigid UPVC pipes
Steel rope with cover
32mm dia HDPE pipe
Labour charges for lowering including transportation
Supplying all materials,labour,T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification,testing,earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of Engineer-in-charge 110mm dia U-PVC SWR Pipe (Supreme/Ashirvad)
110mm dia U-PVC Door cross Tee
110mm dia U-PVC Plain Tee
110mm dia U-PVC Door Tee
110mm dia U-PVC Door Bend
110mm dia U-PVC Plain Band
110mm dia U-PVC Plain Shoe Bend
110mm dia U-PVC 'P'Trap
110mm dia U-PVC Offset without ear
110mm dia U-PVC Socket plain
110mm dia U-PVC Cowl
110mm dia U PVC SWR Clamp
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC / HCI pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge 250mm to 375mm thick wall
Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge 580mmx440mm size Orissa Pan(Hind ware/Parryware/ Cera Make)
Supplying all materials,labour,T&P and fitting and fixing vitrous Chaina washed down water Closet (European
type water closet - EWC) with integral P or S type trap to the floor including wodden plug and chromoum plated screw including jointing the trap with soil pipe in CM(1:1) fixing plastic seat cover for washed down water closet with crmium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of Engineer-in-charge. European Water Clost with S trap Plane (Hind ware/Parryware/ Cera Make)
Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge 600x450x250 mm stainless steel kitchen sink with drain board-glossy-IS:13983 - 1994 (Jayna make)
Supplying all materials ,labour ,T&P and fixing Wash basin with hole for pillar taps with cast iron or MS brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. fixing pedestral for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered hot and cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin , fixing 12mm dia CP brass waste etc.all complete as per specification and direction of Engineer-in-charge. 550mmx400mm size wash hand basin with Porcelain pedestal(Hind ware/Parryware/ Cera Make)
Counter top basin 560x455(Hind ware/Parryware/ Cera Make)
Supplying all materials ,labour ,T&P and fixing Mirror of superior glass mounted on 6mm thick A.C. sheet or ply wood sheet and fixed to wooden plugs with chromium plated brass screws and washers etc.all complete as per specification and direction of Engineer-in-charge Mirror(Bevellededge) 600mmx450mm
Supplying all materials,labour,T&P and fixing standard sized Glass-shelf with C.P brass bracket and guard rail complete fixed to wooden pluges with screw etc.all complete as per specification and direction of Engineer-in-charge. 600mmx125mm size glass shelf with C.P guard rail
Supplying all materials ,labour ,T&P and fixing standard sized CP brass towel rail complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge 25mmx600mm long CP Towel rail
50mm dia ASTM ( Sch-80 ) PVC Pipe In 2nd floor
C P Towel Ring
50mm dia ASTM ( Sch-80 ) PVC Pipe In 2nd floor
Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge CP soap holder
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. In ground floor
Supplying all materials, labour, T&P and providing brick work with K.B.bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge InGround floor (Super structure )
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn first floor In first floor
50mm dia ASTM ( Sch-80 ) PVC Pipe In 2nd floor
Supplying all materials labour T&P and filling in Sunken floors in toilets with sinter (light weight Slag)well watered and rammed including conveyance of all materials to work site payment of royalty taxes etc all complete as per direction of Engineer in charge In ist floor
Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1"6" in wall including cleaning,applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 30 x 30 cm Kajaria / Somany / Johnson to be pree approved .In ground floor
In First floor
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge . 30cm x 45cm Kajaria / Somany
Supplying all materials, labour,T&P and providing cement concrete(1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height In ground floor
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS RO+UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1
for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. Aquaguard 120 PSS RO+UV
Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make)
for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge. Aquaguard 120 PSS RO+UV
Supplying all materials,labour,T&P and laying in trenches ( to level or slope ) unplasticized PVC pipe conforming to IS:4985/2000 of the following outside dia for class-3 (0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/ as per manufactures's providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the Type-C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge. 110mm dia U-PVC pipe ( Allround concrete )
160mm dia U-PVC pipe ( Allround contrete )
Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge. In side size 250mmx250mm
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size : 760mmx760mmx460mm
R.C.P.C.Cover(18" round man hole cover)
Supplying all materials ,labour ,T&P and constructing Man Hole Chamber of inside size 910mmx910mmx910mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken black hard granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing, conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size : 910mmx910mmx910mm
R.C.P.C.Cover(24" round man hole cover for septic tank )
Supplying all materials, labour, T&P & constructing Soak Way Pit of the following size with dry brick walling from bottom upto invert of inlet pipe and KB brick work in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size crusher broken hard black granite metal on bed, 12mm thick cement plaster in cement mortar (1:4) inside and outside over masonry brick work, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips fitted with iron lifting handles including earth work in open well excavation in all kinds of soil and refilling of cavity around the pit and painting the iron works, watering, curing,cost of all materials,conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per approved drawing,PH specification and direction of the Engineer-in- charge. 1.40m dia x 2.00m deep inside size Soakway Pit
Construction 1 nos 100 users RCC Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
- do - with addl. Depth of 1.5 m
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge In ground floor
Supplying all materials, labour, T&P and providing shoring and shuttering for foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. In ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge For Roof slab
For RCC wall
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
110mm dia U-PVC Plain Shoe Bend
Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including wateri
ng,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge 110mm dia UPVC Tee
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipe
110mm dia U-PVC Plain shoe bend
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge 1 x2 x(6.80+2.6) x 0.30 x 2.40
Sinking of 150mm dia tubewell through hand boring (water jet ) method (2nos) .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge
Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge
Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres
Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres
Reaming 150mm to 200mm dia from 0 to 360 metres
Reaming 200 mm to 250mm dia from 0 to 360 metres
Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres
Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge.
Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres
Cost of 150mm dia PVC ASTM pipe (sch-80)
Cost of 150mm dia PVC cutting slut
Cost of 100 mm dia C.I. cutter plug
Cost of bentonite powder
Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge
stage.html
html • 0.09 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
DTCN.pdf
Tender Documents • 0.57 MB
BOQ_572283.xls
BOQ • 6.34 MB