Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹17.3 L+₹32,980 (1.94%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹23.8 L+₹6.8 L (40.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
25 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JAMMU
GE AF JAMMU
REPAIR MAINTENANCE OF INTERNAL ELECTRIC SUPPLY AND SUMMER WINTER APPLIANCES AT PCDA ARMY OFFICE AND RESIDENTIAL COMPLEX UNDER GE AF JAMMU
2025_MES_738347_1
CA NO GE/AFJ-59/2025-26
Open Tender
Civil Works
Item Rate
180 days
JAMMU
Pls refer tender document
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹63,000
Yes
23 Jan 2026
4 Nov 2025
2 Dec 2025
4 Nov 2025
25 Nov 2025
18 Nov 2025
Amount
Attending complaints for checking of existing electrical points wiring upto size 6 sqmm in any Buildings for continuity ,no light including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, tightning of loose connections etc all as specified. Note:- (a) Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all working days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor. (b) One complaint shall be considered as Each Job (c) The contractor shall depute ITI holder electrician & semi skiilled helper to attend complaits, with proper uniform as finalised by Engr-in-Charge. (d) Material required for attending complaints will be given as supply only item. (e) Any parts required to be replaced shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule. (f) Taking down the 'Supply only' item is included in the rate quoted against of Srl item No. 1 of BOQ.
Taking down carefully copper/aluminium point wiring (light, fan,bell, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
M&L for point wiring for light/fan/Bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping or existing conduit with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface/ flush type with PVC sheet for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc complete all as specified.
All as per item No.3 above but for one multipin 5 amps socket outlet on same board.
All as per item No.3 above but for one multipin 5 amps socket outlet on independent board
All as per item No . 3 above but with 2.5 sqmm cable and 2.5 sqmm for earth continuity for multipin 15 amps socket outlet flush type on independent board.
S&F switch piano button flush type, single pole one way 5 amps complete all as specified.
S&F switch bell push piano flush button single pole one way 5 amps complete all as specified.
S&F piano switch two way flush button 16 amps complete all as specified.
S&F 5 pin socket outlet 2 in 1, 3 pin, 5 amps flush type complete all as specified.
S&F 5 pin switch socket combination 2 in 1, 5 amps flush type complete all as specified.
S&F switch socket combination 3 in 1, 5 and 15 Amp flush type controlled by one switch complete all as specified.
S&F ceiling rose, 3 phase on PVC square blocks surface bakelite 65 x 50 mm, 3 terminal.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete complete all as specified.
S&F flush type fan regulator 230V, electronic rotary stepped complete all as specified.
S&F Call bell ding dong AC, 23 Volts, single pole type complete all as specified.
Supply only Switch Modular (piano) flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and directed.
Supply only Switch Modular (piano) flush button single pole one way 16 amps with suitable plate and cover complete all as specified and directed.
Supply only Socket outlet flush modular (piano) type 2/3 pin 6 Amps with suitable plate and cover complete all as specified and directed.
Supply only in repair Socket outlet flush universal modular (piano) type 3/5 pin 6/16 Amps with suitable plate and cover complete all as specified and directed.
Supply only three modular sheet fitting.
Supply only four modular sheet fitting.
Supply only Six modular sheet fitting.
Supply only eight modular sheet fitting.
Supply only twelve modular sheet fitting.
Supply only copper wire 1.5 Sqmm single core
Supply only copper wire 2.5 Sqmm single core
M&L for sub main wiring with two run of 6 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLS cable in and including electrical grade PVC conduits of desired colour not less than1.2 mm thick and 25 mm wide & 6 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one complete all as specified.
Ditto- as per item No.28 above but size 4 Sqmm two runs and with 4 sqmm FRLS copper wire for earth continuity.
Ditto- as per item No.28 above but size 2.5 Sqmm two runs and with 2.5 Sqmm FRLS copper wire for earth continuity.
Supply only LED tube light fitting 18/20 watt wall mounted LED batten with aluminum housing & integrated electronic driver.
Supply only LED tube light fitting 9/10 watt wall mounted LED batten With aluminum housing & integrated electronic driver.
S & F in repair by flushing to walls MCB distribution board Double door SPN 230 volts 12 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc complete all as specified.
S & F in repair by flushing to walls MCB distribution board Double door SPN 230 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc complete all as specified.
S & F in repair by flushing to walls MCB distribution board double door 240 volts 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc complete all as specified.
S & F in repair Distribution board iron clad TPN DB, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar. complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Note: MCB's and MCCB will be measured and paid separately under relevent items).
S&F MCB SP 6 to 32 Amps, 240 Volts complete all as specified.
S&F MCB SPN upto 32 Amps ,240 Volts complete all as specified.
M & L for MCCB TPN 100 Amps ,415 Volts complete all as specified.
M & L for MCCB TPN 125 Amps ,415 Volts complete all as specified.
S&F MCB SPN 63 Amps, 230 V,AC.complete all as specified.
S&F TPN 63 Amps 415 V. complete all as specified.
M & L in repair metal socket enclosure with 240 volt MCB 20 Amps, with metal plug top complete all as specified.
M & L for earthing complete with copper earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth copper strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Supply only 10 Watt energy efficient wall mouted LED Bulk head luminaire made off die cast aluminium with opal diffuser .
Supply only 36 watts recess /pendant mounting ultraslim LED flat panel 2' X 2' made of extruded aluminium frame with high LEDs & glare free opal diffuser.
Supply only round sheet for blank area 2.5 " dia and 3 "
S & F MCCB Three pole 415V 100 Amps 16 kA incl taking down old unserviceable one.
S & F MCCB Three pole 415V 200 Amps 25 kA incl taking down old unserviceable one.
S & F MCCB Three pole 415V 250 Amps 25 kA incl taking down old unserviceable one.
M&L in replacement of PVC Boards closed recessed of size 4x4x2 inches
M&L in replacement of PVC Boards closed recessed of size 4x7x2 inches
M&L in replacement of PVC Boards closed recessed of size 8x10x2 inches
M&L in replacement of PVC Boards closed recessed of size 10x12x2 inches
Supply only PVC electrical insulation tape width 25-30mm and length 35-40 mtrs
Supply only PVC Gang box two way or one way for shifting of 5A/15 Amps switch & socket etc
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron 4mm dia wire by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Supply only 9 watts LED Bulb Make Wipro/Havells/Siska
Supply only 18 way modular box
Supply only 14 way modular box
Supply only 12 way modular box
Supply only 8 way modular box
Supply only 6 way modular box
Supply only 4 way modular box
Supply only 3 way modular box
Taking down carefully the existing unserviceable ceiling / Exhaust fans/ Wall mounted fan of any make/ model and sweep from different sites in the building for overhauling / servicing after disconnecting carefully cleaning and checking unserviceable components, and replacing the defective components such as bearing, rubber bush/bolt, gunmetal bush, capacitor burnt windings flexible cord, shaft and painting etc., including assembling after lubricating the movable components and installing in its original position connecting, testing and commissioning all as specified and directed by the Engineer-in-charge. Note:-Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor / cord flexiable / stator/rotor and painting only will be measured and paid separately under respective item.
M & L for rewinding of ceiling fans 1200/1400mm sweep of any make/model, including removal of existing burnt windings carefully from the slots,cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enmelled copper winding wire of same gauge/same number of turns as that of existing and connecting the coils suitable to operate on 230 volts single-phase AC supply permanent capacitor type, tying the windings and applying air dry insulating varnish and drying the windings including replacing the defective components such as bearing, gun metal bush,rubber bush/bolt, capacitor,flexible cord, shaft and painting including assembling after lubricating movable components complete including testing complete all as specified and directed Note :-(1) Fan will be issued from AGE E/M store yard through gate pass. (2) Bearing/ Gunmetal bush/ rubber bush bolt/ capacitor / cord flexiable / stator/rotor and painting only will be measured and paid separately under respective item.
All as per item no 67 above but exhaust fan of 450/300/250mm sweep of any model/make.
All as per item no 67 above but Wall mounting fan of any sweep , any model/make.
S&F ceiling fans complete with aluminium blades, down rods, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 5.00 BEE Five star rated with brushless direct current motor (BLDC ) with high efficenecy as specified, complete all as specified and directed by Engr-in-charge.
Supply only fan motor 150W 1500 RPM suitable for Exhaust fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.
Supply only fan motor 90W 1500 RPM suitable for Wall Mounting fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make CG/Bajaj/Havells
S&F steel body heavy duty exhaust fan 300mm complete acessories with suitable copper wire including taking down old unserviceable burnt exhaust fan complete all as specified and directed.Make-crompton/Havells/Orient
S&F PVC exhaust fan 250mm complete acessories with suitable copper wire including taking down old unserviceable burnt exhaust fan complete all as specified and directed.
S&F galvanised/aluminium metal sheet frame exhaust fan flappe shutter outdoor type of size 20x20 inches having no chance of rusting including nuts, bolts, screws etc. flappe is fitted to any height/floor of building complete all as specified and directed by Engineer-in-charge.
S&F wall mounted fan complete with blades,hanging accessories,pull chain control and acessories,1350 RPM,230V, 400MM size sweep minimum air delivery 72CMM air delivery complete all as specified and directed.Make-Bajaj/Havells/Crompton
Supply only ball bearing suitable for any fans of any Sweep any make / model all as specified and directed by the Engineer-in-charge.Make TATA, SKF
Supply only gunmetal bush suitable for ceiling fan / wall mounting fan of any make/model/ sweep of 1200/1400 mm and Exhaust fan of any sweep all as specified and directed by the Engineer-in charge.
Supply only twin core PVC flexible copper conductor of size 23/0076 all as specified and directed by the Engineer-in-charge
Supply only capacitor of 2.5/3.15/4.0 Mfd. AC 230/240 volts, 50 Hz
Supply only of PVC canopies of suitable size for ceiling fan of any make/model(set of two) with screws.
Supply only U clamps with rubber reel and nuts/bolts of suitable size with pins.
Supply only of rubber bush kit suitable for exhaust/wall mounting fan of any make/sweep complete.
Taking down existing louvers from any location or any height of bldg. with safety and re-fixed after repair with fastner complete all as specified and directed.
Supply only of metallic / plastic louversof size 21" x 21" for 350mm/450mm/300mm sweep exhaust fan including fixing arrangment i.e. nuts , bolts, washers etc. complete all as specified and directed by Engr-in Charge.
Supply only Modular regulator electronic rotary step type suitable for ceiling fan of sweep 1200/1400 mm complete all as specified and directed.
Supply and fixing automative batteries 12 volts 180AH, cold cranking ability (CCR) 1100 suitable for graeves DG set of Capacity 320 KVA all as specified and directed by engr-in-charge.
Labour only for day to day maintenance and servicing for Split AC/Window AC for PCDA Jammu (excluding sundays and holidays) with high skilled refrigerator mechanic and helper including detecting fault of split/window air conditioner complain and servicing all unserviceable parts for split/window ac and water cooler, deep freezer, refrigerator and replacement of u/s parts & repair of all necessary items and handed over to user for serviceable condition , all as specified and direted by Engineer In Charge. Note: (a) Contractor has to employ highly skilld Refrigerator Mechanic with helper and necessary T&P for attending day to day complaints of Ref and AC failing which recovery shall be made at two times of quoted rate. (b) Rate quated shall be inclusive of transport from AF Station to work shop & back shifting within permises. (c) Any parts required to be replaced shall be replaced and paid separately as "supply only " against relevant item (s) of this schedule.
Shifting of Split type AC/ Window type Ac capacity upto 2 Ton , including submain/point wiring all electrical items and drilling, making good on surface of PCC concreting, white cement plastering and all necessary items and transporting complete one location to other location in PCDA (NC) Jammu replacing unserviceable parts and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge
Supply only the following Items to incorporate against repairable summer appliances Window / Split Type AC's against relevant items No. 88 here-in- before: -
Blower motor complete suitable for window/Split type AC upto 2.0 Ton.
Thermostat switch suitable for window/Split type AC up to 2 Ton. Make - Ranotroll, Denfess
Relay box suitable for window Type AC upto 2 Ton. Make- Voltas/ Bluestar/ LG/ As on site.
Power control Board ( PCB ) for window type / split Type AC up to 2 Ton.
Wiring kit suitable for Window/split AC and window Type AC upto 2 Ton.
Condenser fan motor complete with fan suitable for Window/split Type Air conditioner upto 2 Ton.
Cooling coil evaporator fan motor complete suitable for indoor unit of split type air conditioner upto 2 ton.
Relay suitable for Window/Split Type AC upto 2 Ton.
S&F of condenser outdoor unit capacity 2TR/1.5TR of split AC and also removing old unserviceable condenser complete all as specified and directed by Engineer-in-Charge.
Plastic air filter suitable for split AC indoor unit AC upto 2 TR.
Foaming insulator for AC suction/ cooling line ( Approx - length 15').
Supply and fixing as in replacement ( hermetically ) uncut sealed compressor unit for Window/Split Type Air conditioner with filling of refrigerent gas for the following capacity: -
Capacity 1.0 TR.
Capacity 1.5 TR.
Capacity 2.0 TR.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to Window/Split Type air Conditioners for the following capacity: -
Capacity 1.0/1.5/2.0 TR.
Repair to Power control Board (PCB) of Window/Split type AC upto 2.0 TR capacity.
S&F copper pipe 5/8" and removing old unserviceable copper pipe complete all as specified and directed by Engineer-in-Charge.
S&F copper pipe 1/4" and removing old unserviceable copper pipe complete all as specified and directed by Engineer-in-Charge.
Supply only the following capacitors to incorporate against repairable summer appliances Window / Split Type AC's , Desert cooler, Water cooler: -
Supply only Running capacitor capacitor 45 MFD. Make- Epcos/havells
Supply only Running capacitor 50 MFD. Make- Epcos/havells
Supply and fixing Plug top 15 Amps capacity, fixed in repairs complete all as specified and as directed.
Supply and fixing Plug top 5 Amps capacity fixed in repairs complete all as specified and as directed.
S&F PVC insulated sheathed service wire twin core 10 sqmm aluminium solid conductor 1100 volts grade including taking down old unserviceable one complete all as specified and directed.
M&L for minor Repair to Voltage stabilizer (up to 6 KVA)
S&F Trigger Transformer (Control Step- down- transformer) 12-0-12 Volts for 03 KVA to 06 KVA.
S&F Power Relay 24 Volts / 250 Ohms 30 Amps ( 03- Nos) for 03 KVA to 06 KVA.
M&L Rewinding transformer of voltage stabalizer of capacity upto 05 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed.
S&F in repairs 240 Volt, sheet metal enclosure, distribution board single pole and neutral 2 way without bus bar complete all as specified.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 110V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified.
Disconnecting water and electric connections from existing position of geyser capacity 25/50 ltr, taking down geysers fixed to walls at any height, transporting to/ depositing in MES store yard for inspection of Engineer-in-Charge to ascertain the serviceability / unserviceability and quantam of repairs involved including transportation of serviceable geyser capacity 25/ 50 Ltr from workshop to building site as directed for fixing in existing position making water and electric connections and testing complete as directed.
Repairs to geyser capacity 25/ 50 Ltr involving the following operations. (a).Dismantling (opening) of geyser complete in MES yard / workshop part by part of all the stationary parts, cleaning the covers and parts as applicable (b).Servicing, cleaning of geyser accessories and parts as applicable such as inner tank body, water inlet/ outlet assembely, heating element etc descaling with acid wash all as directed by Engineer-in-Charge. (c). Assembling of geyser complete with old serviceable parts, replacement of unserviceable parts by new as ordered, renewal of nuts bolts and washers, rubber gasket complete as directed by Engineer-in-Charge. Note:- (i) Parts required to be replaced shall be measured and paid separately as "supply only " against relavant item (s) of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item. (ii) Any minor parts / repairs involved to make the geyser completely functional even if not notified by Engineer-in-Charge shall be carried out by the contractor without any extra cost to the Department
Shifting of Geyser of capacity upto 50 Ltrs including submain/point wiring all electrical items and drilling , making good on surface of PCC concreting, white cement plastering and iron frame /angle all necessary items and transporting complete from one location to other location and handing over the machine/ equipment in serviceable condition to the user including fixing to new location all as specified and directed by Engineer-in-Charge.
Supply only Heating element with rubber washer ('O' ring) cap 1.5 KW. (triangular / round ) any type. Make- Make- Theetta, Micron., DasPass , Bajaj
Supply only Heating element with rubber washer ('O' ring) cap 2 KW (trangular/ round ) Type Make- Theetta, Micron., DasPass , Bajaj
Supply only indicator bulb neon round / square type single phase 230 Volt
Supply only Safety plug 15mm ( brass ) for geyser cap 25/50 Ltr.
Supply only Thermostat 30 deg.C to 70 deg.C 230 Volts.
Supply only Inner tank for geyser cap 25/50 ltr of MS Steel sheeting thickness of gauge 20 (Geyser make :- Bajaj, usha, recold, venus, vguard)
Supply only geyser water (inlet/outlet) assembly brass for geyser cap 25 Ltr of any type.(Geyser make :- Super hot, Racold, Bathwell, Ditz, Kumar, Pearl, Classic, Pieco)
Supply only PVC connection 600 mm long complete with brass nut, washers, seals, etc suitable for hot & cold water complete all as specified and directed. Make: Theetta / Micron / DasPass / Bajaj
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/S VIDYA ENTERPRISES (BID ID -3481569)
VIDHATA ELECTRICALS (BID ID -3487765)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
tender59.pdf
Tender Documents • 1.45 MB
BOQ_826741.xls
BOQ • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .