Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹26.8 L+₹1.9 L (7.54%)Rejected-AOC H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹29.9 L+₹5.0 L (20.1%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹33.2 L+₹8.3 L (33.4%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L4 | Rejected-AOC Rejected |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
27 Jul 2021, 6:00 pmClosed
GE (N) Mamun
GE (N) Mamun C/o 56 APO
REPAIR/ REPLACEMENT OF INTERNAL WIRING, LIHGT FITTINGS,SUB MAIN AND CONNECTED ITEMS IN OTM ACCN UNDER AGE E/M-I OF GE (N) MAMUN.
2021_MES_455162_1
GE (N)/M- /2021-22 NIT-09
Open Tender
Civil Works
Item Rate
270 days
Mamun
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (N) Mamun
₹84,000
Yes
11 Nov 2021
28 Jun 2021
30 Jul 2021
28 Jun 2021
27 Jul 2021
13 Jul 2021
Amount
Taking down carefully unsv copper/aluminium point wiring (light/fan/Bell/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lamp holders, regulators, light fitting etc removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions separately).
Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 Sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit not less than 20 mm dia and 1.8 mm thick including all fitting viz tees, bend, junction box and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunken GI pressed steel terminal boxes with 3mm thick hylam/masonite sheet fixed with brass screws for mounting switch/sockets or approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switch sockets complete including cutting grooves for concealed wiring and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface specifications including connection of cable with MCBs through proper size copper/brass thimbles for one light/fan/bell point controlled by one 1 way switch.
All as per Srl item No 2 here in before but for 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way.
All as per Srl item No 2 here in before but for 5 Amp socket outlet point on same board controlled by one switch 5 Amp one way.
All as per Srl item No. 02 above but one 15Amp socket point concealed with 2.5Sqmm FRLS PVC insulated multi-strand copper conductor including 2.5Sqmm FRLS PVC insulated unsheathed copper conductor earth wire complete all as specified and directed.
M & L for point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 Sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through existing conduit and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunken GI pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws for mounting switch/sockets or approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting moular switch sockets complete connection of cable with MCBs through proper size copper/brass thimbles for one light/fan/bell point controlled by one 1 way switch.
All as per Srl item No. 6 here in before but for 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way.
All as per Srl item No. 6 here in before but for 5 Amp socket outlet point on same board controlled by one switch 5 Amp one way.
All as per Srl item No. 6 here in before but for one light point controlled by two 2 way switch.
All as per Srl item No. 6 above but one 15Amp socket point with 2.5Sqmm FRLS PVC insulated multi-strand copper conductor including 2.5Sqmm FRLS PVC insulated unsheathed copper conductor earth wire complete all as specified and directed.
S & F switch piano flush button single pole one way 5 amp 240 volts, all as specified and directed.
S & F Socket outlet 2 in 1, 3 pin, 5 amps, flush type, 240 volts all as specified and as directed.
S & F switch 15 Amps, flush type with shutters, 240 volts all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type, 240 volts all as specified and as directed.
S & F Switch Socket outlet combination 2 in 1, 5 Amp flush type, 240 volts all as specified and as directed.
S & F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W.
S & F switch piano flush button single pole two way 5 Amp 240 volts, all as specified and as directed.
S&F Bell push, flush type, 5 amp AC 230 Volt etc complete all as specified and directed.
S&F ceiling rose jumbo type PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals.
S&F modular socket 6/10 Amp, 2/3 Pin multipurpose, 2 module, complete all as specified and directed.
S&F modular switch one way 6/10 Amp one module, front operated complete all as specified and directed.
S&F modular switch piano type flush button single pole 16/20 Amp one module, front operated.
S&F modular socket 6 Amp/16 Amp, 2/3 Pin multipurpose, 2 module, complete all as specified and directed.
S&F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as spd and directed.
S&F Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed.
S&F Lamp holder jumbo type, PVC/Polycarbonate type with back plate incl 15W LED lamp complete all as specified.
Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit and removing materials to store for keeping in safe custody for taking credit complete all as specified.
S&F in replacement sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 sqmm and one single core FRLS PVC insulated multistranded unsheathed flexible copper conductor 4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface all as specified and directed.
All as per Srl item No 28 here in above but for sub Main Wiring of size 2x6 Sqmm with one single core FRLS PVC insulated multistranded unsheathed flexible copper conductor 6 Sqmm size (green colour) complete all as specified and directed.
S&F in replacement sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 Sqmm and one single core FRLS PVC insulated multistranded unsheathed flexible copper conductor 4 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing PVC concealed conduit complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface all as specified and directed.
All as per Srl item No 30 here in above but for sub Main Wiring of size 2x6 sqmm with one single core FRLS PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) complete all as specified and directed.
Supply and fixing LED tube lights fitting 1x 20W, 220V,AC white powder coated CRCA box type channel with decorative end cap alongwith LED T8 tubular lamp 20W linear with extruded aluminium/pc body and PC diffuser and inbuilt drive incl connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser complete including connecting up with three core twisted flexible copper conductor cable of suitable size.all as specified.
Supply and fixing surface mounted Decorative,uplight light fitting including for 9 W LED lamp and with decorative diffuser and mounting clips and lamp holder , wall mounting arrangment and all as specified and directed.
Supply and fixing Decorative 07/10Watt LED mirror light with driver and wall mounting arrangment and all as specified and directed.
Supply and fixing round surface mounted 18Watt LED panel having aluminum housing and high translucent frosted plastic diffuser with inbuilt driver with efficacy 100Lm/W, CRI>80 with 5700+/-300K CCT complete complete all as specified and directed.
Supply and fixing recess mounted 18Watt LED round panel polycarbonate housing down lighter and high qaulity diffuser, separate driver, efficacy 100Lm/W, CRI>80 with 5700+/-300K CCT complete with locking arrangement incl taking out old unsv recess mounted fitting complete all as specified and directed.
Supply and fixing LED 36Watt 2x2 recess mounted panel made out of white powder coated CRCA housing with LEDs and high quality diffuser inbuilt driver, efficacy 100Lm/W, CRI>80 with 5700+/-300K CCT complete suitable for grid ceiling incl taking out old unsv recess fitting complete all as specified and directed.
S & F in replacement SPN MCB DB 12 way sheet metal enclosures double door 230 V AC, 50 Hz AC having copper bus bar of rating 200Amps complete all as specified and directed.
S & F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC having copper bus bar of rating 200Amps complete all as specified and directed.
S & F in replacement SPN MCB DB 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC having copper bus bar of rating 200Amps complete all as specified and directed.
S&F MCB SP 240V, 50Hz, 10 KA,of rating 6 to 32 Amp all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA,of rating 32Amp all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA,of rating 40-63Amp all as specified and directed.
S&F sheet metal enclosures double door VTPN MCB DB 4 way 415 V AC, 50 Hz with 250Amps rated copper bus bar complete with IP 43, IK-09 protection suitable for flush mounting into the wall incl MCCB 63Amps, 4P, 16kA breaking capacity with fixed magnetic and thermal setting of same make as of DB and making connection with cable by means of suitable size of Al thimbles incl making good the disturbed surface and matching with the existing surface specification complete all as specified and directed.
S&F hylam/masonite sheet 3mm thick with brass screws for repair to existing switch board by taking out the old existing serviceable switches, sockets, regulators and refixing the same after replacement of old unsv/broken Hylam sheet of size upto 7"x4" complete all as specified and directed.
All as per item No 46 above but of size 8"x10".
S&F Modular plate cover plate with support frame(inner and outer) 8 module rectangular or Square complete all as specified.
S&F Modular plate cover plate with support frame(inner and outer) 12 module rectangular or Square complete all as specified.
S&F Decorative gate/garden light made up of high grade unbreakable polycarbonate material with collar for retrofit Lamp B22 base and incl LED lamp of 12Watt and making suitable arrangements for fitting on existing pipe of size 32/40/50mm dia including connecting up with three core twisted flexible copper conductor cable of suitable size including taking down old unsv light fitting complete all as specified.
S&F 35/40 watt Post top LED lights made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP65 Protection and making suitable arrangements for fitting on existing pipe of size 32/40/50mm dia including connecting up with three core twisted flexible copper conductor cable of suitable size including taking down old unsv light fitting complete all as specified.
Supply and fix 18Watt LED lamp suitable for 2G11 lamp holder complete all as directed and specified.
M & L for sheet metal enclosure with plug socket and MCB 20A SP, 240Volts (2P+E) including Cutting chases of suitable size on existing wall, flushing into the wall and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface including testing on connected load complete all as specified and directed.
M & L for sheet metal enclosure with plug socket and MCB 20A SP, 415Volts (3P+E) including Cutting chases of suitable size on existing wall, flushing into the wall and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface including testing on connected load complete all as specified and directed.
M/S HIMANSHU BUILDERS
KULBHUSHAN AGGARWAL
commercial traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .