| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.7 CrAdmitted-Finance 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹56.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹61.4 CrAdmitted-Finance | ₹61.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹61.7 CrAdmitted-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹61.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹62.3 CrAdmitted-Finance | ₹62.3 Cr | L4 | Admitted-Finance |
| 5 | L5₹64.0 CrAdmitted-Finance 34 KALIKA DAS ROAD NATUN BAZAR P O DIST COOCH BEHAR PIN 736101 W B | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | ₹64.0 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M P KHAITAN L10 | Hariom Projects Pvt Ltd L9 | Som Projects Pvt Ltd L13 | NARSINGH DEVELOPERS LLP L8 | Adhunik Infrastructures Pvt Ltd L2 | D. K. PROJECT PRIVATE LIMITED L5 | surendra infrastructure pvt ltd L12 | VERMA BROTHERS L7 | MAA BHAGWATI ASSOCIATES L3 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L1 | GANGA INFRABUILD PVT LTD L4 | M K GUPTA & CO. L6 | CHHABINDRA KUMAR PRADHAN L11 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00BUILDINGS & STRUCTURE (Sch 'A' PART-I) | ||||||||||||||||
| 1.01 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 43,23,70,400.00 inserted by the MES in Schedule ‘A’ Part-I. | 1 | LUMP SUM | 46,50,00,000 ₹46.5 Cr | 49,50,00,000 ₹49.5 Cr | 52,59,18,725.5 ₹52.6 Cr | 45,85,00,000 ₹45.9 Cr | 44,10,00,000 ₹44.1 Cr | 48,45,00,000 ₹48.5 Cr | 48,33,00,000 ₹48.3 Cr | 46,80,00,000 ₹46.8 Cr | 45,15,00,000 ₹45.1 Cr | 39,50,76,453 ₹39.5 Cr | 46,00,56,834.84 ₹46.0 Cr | 46,25,86,323 ₹46.3 Cr | 49,37,66,996.8 ₹49.4 Cr |
| 2.00EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) | ||||||||||||||||
| 2.01 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 38,76,738.25 inserted by the MES in Schedule ‘A’ Part-II. | 1 | LUMP SUM | 28,30,000 ₹28.3 L | 38,76,738.25 ₹38.8 L | 25,06,723 ₹25.1 L | 31,38,000 ₹31.4 L | 42,00,000 ₹42 L | 37,75,000 ₹37.8 L | 32,00,000 ₹32 L | 29,60,000 ₹29.6 L | 25,00,000 ₹25 L | 14,16,870 ₹14.2 L | 21,95,062.2 ₹22.0 L | 36,50,000 ₹36.5 L | 27,13,716.78 ₹27.1 L |
| 3.00INTERNAL WATER SUPPLY (Sch 'A' PART-III) | ||||||||||||||||
| 3.01 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,22,638.62 inserted by the MES in Schedule ‘A’ Part-III. | 1 | LUMP SUM | 15,20,000 ₹15.2 L | 12,22,638.62 ₹12.2 L | 20,95,685.75 ₹21.0 L | 16,55,000 ₹16.6 L | 13,00,000 ₹13 L | 11,51,000 ₹11.5 L | 16,00,000 ₹16 L | 14,80,000 ₹14.8 L | 14,00,000 ₹14 L | 22,14,700 ₹22.1 L | 13,81,140 ₹13.8 L | 19,56,221.79 ₹19.6 L | 13,44,902.48 ₹13.4 L |
| 4.00INTERNAL ELECTRIFICATION (Sch 'A' PART-IV) | ||||||||||||||||
| 4.01 | Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,16,86,007.47 inserted by the MES in Schedule ‘A’ Part-IV. | 1 | LUMP SUM | 1,58,00,000 ₹1.6 Cr | 1,27,26,062.13 ₹1.3 Cr | 1,22,45,550.6 ₹1.2 Cr | 1,45,90,000 ₹1.5 Cr | 1,21,00,000 ₹1.2 Cr | 1,25,00,000 ₹1.3 Cr | 1,56,00,000 ₹1.6 Cr | 1,32,00,000 ₹1.3 Cr | 1,30,00,000 ₹1.3 Cr | 1,67,72,605 ₹1.7 Cr | 1,19,56,882.5 ₹1.2 Cr | 1,28,54,608.22 ₹1.3 Cr | 1,16,86,007.47 ₹1.2 Cr |
| 5.00ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V) | ||||||||||||||||
| 5.01 | Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,36,73,773.81 inserted by the MES in Schedule ‘A’ Part-V. | 1 | LUMP SUM | 1,63,00,000 ₹1.6 Cr | 1,48,90,739.68 ₹1.5 Cr | 1,70,74,230.9 ₹1.7 Cr | 1,57,50,000 ₹1.6 Cr | 1,45,00,000 ₹1.4 Cr | 1,36,00,000 ₹1.4 Cr | 1,75,00,000 ₹1.8 Cr | 1,43,00,000 ₹1.4 Cr | 1,40,00,000 ₹1.4 Cr | 1,50,76,170 ₹1.5 Cr | 95,54,006.62 ₹95.5 L | 1,91,43,283.33 ₹1.9 Cr | 1,36,73,773.81 ₹1.4 Cr |
Updated dates
Tender Value
₹65 Cr
EMD Value
₹15 L
Closing Date
24 Mar 2026, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF OTM ACCN FOR CORPS HQ COMPLEX AT SUKNA UNDER GE (P) SILIGURI
2026_MES_749058_1
98737/SUK/SZ/E8
Open Tender
Civil Works
900 days
SUKAN
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (P) SILIGURI
₹15 L
Yes
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA
16 Jun 2026
17 Jan 2026
31 Mar 2026
17 Jan 2026
24 Mar 2026
17 Mar 2026
17 Jan 2026 - 6 Feb 2026
9 Feb 2026
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 43,20,08,900.000 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,82,81,023.25 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 17,59,560.78 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,17,05,504.31 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,36,55,882.91 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 18,24,836.95 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 46,25,252.23 inserted by the MES in Schedule ‘A’ Part-VII.
FALSE CEILING (Sch 'A' Part-VIII)
Lump sum price worked out by the Contractor for “(FALSE CEILING)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 71,24,306.40 inserted by the MES in Schedule ‘A’ Part-VIII.
SECURITY WALL, FENCING & GATE (Sch 'A' Part-XVII)
Lump sum price worked out by the Contractor for “(SECURITY WALL, FENCING & GATE)” as listed in Schedule ‘A’ Part-XVII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 76,17,103.76 inserted by the MES in Schedule ‘A’ Part-XVII.
EXTERNAL WATER SUPPLY (Sch 'A' Part-IX)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,94,379.42 inserted by the MES in Schedule ‘A’ Part-IX.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 78,08,662.40 inserted by the MES in Schedule ‘A’ Part-X.
FIRE FIGHTING (Sch 'A' Part-XI)
Lump sum price worked out by the Contractor for “(FIRE FIGHTING)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 83,97,635.72 inserted by the MES in Schedule ‘A’ Part-XI.
FIRE ALARM SYSTEM (Sch 'A' Part-XII)
Lump sum price worked out by the Contractor for “(FIRE ALARM SYSTEM)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 25,25,089.00 inserted by the MES in Schedule ‘A’ Part-XII.
CONDUIT FOR TELEPHONE / INTERNET (Sch 'A' Part-XIII)
Lump sum price worked out by the Contractor for “(CONDUIT FOR TELEPHONE / INTERNET)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 8,09,280.00 inserted by the MES in Schedule ‘A’ Part-XIII.
LIGHTNING PROTECTION (Sch 'A' Part-XIV)
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION) ” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 5,10,689.60 inserted by the MES in Schedule ‘A’ Part-XII.
LIFT (Sch 'A' Part-XV)
Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,02,52,510.80 inserted by the MES in Schedule ‘A’ Part-XV.
AIR CONDITIONING (Sch 'A' Part-XVI)
Lump sum price worked out by the Contractor for “(AIR CONDITIONING)” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 16,82,087.96 inserted by the MES in Schedule ‘A’ Part-XVI.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XIX)
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved Earth may be mixed with granules / pebbles not exceeding 40 mm size (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any, transportation, taxes if any etc. complete all as specified and directed. NOTE :- (a) Earth required for the item shall be supplied by contractor from outside of MOD land at any lead, at his own arrangement. (b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (c) Forming embankments / filling in low lying areas including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming / rolling and finishing of required size, shape etc not exceeding 1.5 m high from base / natural ground level. (d) With reference to Clause 3.6 of MES Schedule Part-II on Serial Page No. 21, it is clarified that measurement of the above item shall be of finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk. (e) Total quantity / partial quantity of earth may not be available in Sukna Area. The contractor shall bring the earth outside area and it is advised to quote the rate considering available of soil and its lead involved.
INTERNAL WATER SUPPLY S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down for iron pipe 20 mm bore and fixed complete all as specified and as directed.
INTERNAL ELECTRIFICATION S & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified and directed. (AC & GYSER POINT)
S & F modular type 3 pin Metal Clad S/B with SP 20A MCB, conforming to IS 1293: 2005 complete all as specified and directed. (Power Point With 4sp mm wire)
S & F modular type 1 module RJ-11 telephone socket with shutter complete all as specified and directed
S & F modular type 1 module co-axial type TV socket complete all as specified and directed.
S & F modular type 1 module Regulator complete all as specified and directed.
S & F Engagement light & Switch with all Other accessories complete all as specified and directed.
S & F single pole & neutral double door DB, 6 way, modular type, double door, metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. NOTE : DP RCCB / RCBO / Isolator / MCB & SP MCBs shall be measured and paid separately.
M & L for galvanised iron strip 50X6mm GI wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
S & F 12W LED Concealed Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 6W LED Concealed Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 5W LED Mirror light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 9W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 36W 2X2 LED Panel light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 24W 1X1 LED Panel light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 36W 2X2 LED surface square light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
S & F 24W 1X1 LED surface square light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed.
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type MLTP (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.20 to 18.21
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 2000A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i]1600A, 415 V, Ics = 100% Icu = 50 kA, 50 Hz 3P ACB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i]100A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos
[ii]250A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iii]320A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [iv]630A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 06 Nos. [vi] LED phase indicators (Red, Yellow, Blue)- 06 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING EMERGENCY PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.23 to 18.25
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 800A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i]630A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i]100A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.
[ii]125A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iii]250A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [iv]25A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.
[v]20A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [vi]16A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 04 Nos. [vii]20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [viii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 11 Nos. [ix] LED phase indicators (Red, Yellow, Blue)- 11 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type FIRE FIGHTING PANEL TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.27 to 18.28
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 200A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i]160A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set
[C] OUTGOING [i] 125A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [ii]16A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iii] 45kw Star-delta Starter - 01 Nos, (iv) 5.5kw Dol Starter - 01 Nos [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 03 Nos. [vi] LED phase indicators (Red, Yellow, Blue)- 03 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-U (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.30 to 18.31
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 125A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i]100A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set
[C] OUTGOING [i] 40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [ii]25A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iii]16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [Iv] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 04 Nos. [v] LED phase indicators (Red, Yellow, Blue)- 04 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-A (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.33 to 18.34
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 125A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i]100A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 20A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos.
[ii] 16A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iii] 32A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iv] 25A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [v] 20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [vi] 16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 04 Nos. [vii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 04 Nos. [viii] LED phase indicators (Red, Yellow, Blue)- 04 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-B (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.36 to 18.37
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 320A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 250A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [ii] 32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos.
[iii] 25A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [iii] 20A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [iv] 20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [vi] 16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [vii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 13 Nos. [viii] LED phase indicators (Red, Yellow, Blue)- 13 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-C (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.39 to 18.40
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 05 Nos. [ii] 32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos.
[iii] 25A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [iii] 20A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [vi] 16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 13 Nos. [vi] LED phase indicators (Red, Yellow, Blue)- 13 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-D (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.42 to 18.43
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 05 Nos.
[ii] 32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [iii] 25A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [iii] 20A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [vi] 16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 13 Nos. [vi] LED phase indicators (Red, Yellow, Blue)- 13 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-E (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.45 to 18.46
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 320A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 250A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos
[ii] 32A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 04 Nos. [iii] 25A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [vi] 20A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [v] 16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [vi] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 13 Nos. [vii] LED phase indicators (Red, Yellow, Blue)- 13 Set
Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-F (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed. Item Continued as 18.48 to 18.49
The MLTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 100A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] 63A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set [C] OUTGOING [i] 25A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.
[ii] 20A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 03 Nos. [v] 16A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 2P MCB, conforming to IEC 60947-2, having m trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos. [vi] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interrupts- 05 Nos. [vii] LED phase indicators (Red, Yellow, Blue)- 05 Set
ROAD, PATH, CULVERT & HARDSTANDING M&L for 2.00 mm thick road marking paint, white or golden yellow, confirming to BS-3262, applying on road surfaces as in lines, dashes, arrows, letters, zebra cross etc., on roads, pavements and the like etc. not exc 10cm wide with thermoplastic road marking paint with glass beads @ 250 - 300 gms/sqm over painted surfaces while the painting surfaces are hot including cleaning surfaces complete all as specified and directed. NOTE : Painting to road surface shall be carried out through mechanical application by the approved applicator of manufacturers instruction..
Supply and installation of Raised Pavement Marker (RPM) with polycarbonate lens electronically welded with the RPM body. The marker shall be scratch proof and abrasion resistant microprismatic polycarbonate lens with polycarbonate reflective panels with dual prismatic cubes capable providing total internal reflection complete all as specified and directed. Dimension: The dimension of the marker is height 15.88mm, width 101.6mm, length 89.2mm. The marker conforms to ASTM D4280 and is in accordance with MOSRTH circular reference No. RW/NH 33023/10/97-DO III dated 11 June 1997. Marker shall be fixed with adhesive and no nails shall be used to affix the marker and shall be marked with manufacturer name.
FIRE ALARM Supply, Installation, Testing & Commissioning of Network Repeater Panel with 6 inch or 640-characters; The LCD shall Display all events / detectors, devices status of complete systems in the networked, The NRP shall be equipped with QWERTY Keypad. Mounting options include an annunciator box, and blank modules are required for mounting and suitable battery backup with maintenance battery dry type alongwith battery charger complete all as specified and directed.
S&F PVC insulated heavy duty unarmoured shield single run copper conductor of 2.5 sqmm 2 core , working voltage 1100 volts conforming to IS: 1554 part -I, drawn through steel conduit for Note: steel conduit with conduit accessories shall be measured & paid separately ). complete all as specified and directed.
S & F rigid metallic ERW steel conduit 25 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc.(6200 Rm copper cable 2.5 sqmm and +200 RM OFC cable) complete all as specified and directed.
Supply and laying underground type Optic fibre Cable(OFC) - Armoured FRLS Cable of 6 core, single mode (wired armoured) inside 25 mm ERW steel conduit colour pipe including root indicator suitable for repeater panel from fire alarm panel to fire station alongwith all suitable required devices like LIOU panel, fibre optic converters and picktails, etc. complete all as specified and directed. (for repeater panel).
FIRE FIGHTING Supply, jointing, testing and laying in trenches/floor/wall etc. in standard lengths, Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating, ISI marked of the 150 MM dia Pipe (nominal diameter), including push on rubber gasket joints complete all as specified and as directed. Note : (i) DI specials/ fittings will be measured and paid separately under relevant items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
S&F Foot Valve conforming to IS 4038, 150 mm dia flanged end and rubber gasket , leather Jip and complete, with stainless steel nut bolt rust proof, including jointing material such as rubber gasket,,etc. suitable for size 150 mm all as specified and as directed.
Supply, installation, testing & commissioning of Air release valve, Cast iron, double air outlet, flanged ends, conforming to IS- 14845, 50 mm bore connected to the main line including all jointing materials as required complete all as specified and as directed.
Supply, installation, testing & commissioning of Sluice Valve, ISI marked heavy duty, 150 mm bore complete all as per IS- 14846-2000, PN 1.6 with gun metal spindle non rising type, and one number hand wheel both end flanged and drilled with necessary holes for bolts alongwith jointing materials viz nuts, bolts and gaskets etc. all as specified and directed.
M&L for construction of brick masonary valves pit of internal dimensions 1.2m x 1.2m x 0.9 mtr complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown on drawing No CE/TD-1001/90, Sheet No1/1 all as specified and as directed.
M&L for fittings ISI marked of size 80 - 200 mm bore suitable for DI pipes class K-12, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining and outside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed.
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type "Motor Control Center" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. Item Continued as 18.63 to 18.65
[vi] 32 A, 10 kA, 230 V, 50 Hz, SPN MCB- 02 Nos. [vii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts- 02 Nos. [viii] LED phase indicators (Red, Yellow, Blue)- 02 Set NOTES: [i] The Panel shall be purchased from the original equipment manufacturer (OEM) only. [ii] The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, GADs, etc. for approval of the Engineer-in-Charge.
Supply, Laying, Jointing,Testing and commissioning of 15 mm dia of ERW Mild Steel pipe Heavy class (C Class) conforming to IS : 1239-1974/2004 Part-I and amendments of wall thickness 5.4 mm, with all online Pipe Fittings, flanges (ASA 150 class), bends, tees, reducers, nuts,bolts (Galvanised, heavy grade ), rubber insertions/ gaskets, washers, 'U' clamp and tapping for gauges/instruments including cutting, welding, fixing in / on walls, ceiling by using suitable supports etc. including surface preparation of pipes and painting with one coat primer and two or more coats of synthetic enamel paint complete all as specified and directed.
S&F of strainer of CS/CI body with SS strainer element 40 mesh matching flange including nut & Bolts , gaskets fire fighting of size 50 mm bore all as specified and directed.
M&L for wrapping coating of underground MS pipe as per IS 10221 of 2008 after cleaning of external pipe surfaces, priming with suitable type synthetic primer, first coat of coal tar enamel with 2mm min thickness, inner wrapping first layer with glass fiber tissue of 0.30mm min thickness, outer wrap of tar impregnated glass fiber with 0.7mm min thickness and white colour latex emulsion paint or white wash complete all as specified and as directed.
S&F PVC insulated heavy duty armoured copper conductor 06 Sqmm 3 Core, working voltage 1100 volts conforming to IS: 1554 part -I, drawn through ERW steel conduit for Fire Alarm System complete all as specified and directed. (LT Panel to Pump)
M&L for road cutting , pavement , hard standing by using cutting machine and making good using cement mortar (1:2:4) given in schedule of laying of pipe up to 200 DI Pipe pipes given in schedule complete all as specified and directed.
S&F ceiling mounted Fire suppression System Modular type clean agent (HFC236fa) Clean Agent (Stored Pressure) Type Capacity 5 Kg Fire Extinguisher IS: 15683 filled with HFC 236FAClean Agent Gas. Complete with squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket. Complete in all respect. Operating Temperature: -30ºC to + 60ºC. Modular type , Fire Class A,B C & Electric with automatic discharge mechanism, discharge time - Min 8 Sec complete all as specified and directed.
S&F fire extinguisher, Dry Chemical Powder, ABC type 6.00 kg Capacity complete with initial charge and wall bracket BIS and BSEN standard complete all as specified and directed.
S&F Fire Extinguisher CO2 Type (light weight squeeze grip type) 4.5 Kg BIS complete all as specified and directed.
S&F Fire Extinguisher Water Stored Pressure Type 9.0 Ltr capacity BIS standard complete all as specified and directed.
S&F Fire Extinguisher Mechanical Foam Type 9.0 Ltrs capacity BIS standard complete all as specified and directed.
S&F auto-illuminated (glow-in-dark) exit sign board with red colour background with appropriate symbol, made up of acrylic sheet for fire escape in minimum 10 cm x 30 cm size to be pasted on wall with high quality adhesive or to be hanged with s.s. hook-chain system complete all as specified and directed.
S&F rechargeable type ceiling/wall mounted Escape lighting showing exit sign in green colour provided with in-built battery suitable to provide minimum 90 min continuous lighting after power cut complete all as specified and directed.
S&F Fire Bucket 09 Ltrs made of iron with high functionality, able to withstand very high temperature with ring handle complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply, jointing, testing and laying in trenches/floor/wall etc. in standard lengths, Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-7conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating, ISI marked 200 mm dia Pipe (nominal diameter), including push on rubber gasket joints complete all as specified and directed. NOTE :- (i) DI specials/ fittings will be measured and paid separately under relevant items of Schedule. (ii) The cost of push on type joint deemed to be included in the rate quoted.
Supply, jointing, testing and laying in trenches/floor/wall etc. in standard lengths, Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-7conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating, ISI marked 150 mm dia Pipe (nominal diameter), including push on rubber gasket joints complete all as specified and directed. NOTE :- (i) DI specials/ fittings will be measured and paid separately under relevant items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
Supply, jointing, testing and laying in trenches/floor/wall etc. in standard lengths, Centrifugally Cast (Spun) Ductile Iron (DI) Pressure Pipes with Spigot & Socket end, Class K-7conforming to IS: 8329/2000 and amendment No.1, suitable for (push-on) rubber gasket jointing with inside cement mortar lining and outside zinc coating with finishing layer of Black Bitumen/Blue Epoxy coating, ISI marked 100 mm dia Pipe (nominal diameter), including push on rubber gasket joints complete all as specified and directed. NOTE :- (i) DI specials/ fittings will be measured and paid separately under relevant items of Schedule (ii) The cost of push on type joint deemed to be included in the rate quoted.
S&F Air release valve, Cast iron, double air outlet, flanged ends, conforming to IS-14845, 80 mm bore connected to the main line including all jointing materials as required complete all as specified and directed.
M&L for construction of Standpost with Pipes Galvanised Iron 20mm dia "Medium grade" ISI marked 1.2 Mtr high with all fittings, ISI marked and one Bib Tap 20 mm size cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe including PCC base all as specified and directed.
M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and directed.
M&L for fittings ISI marked of size 80 - 200 mm bore suitable for DI pipes class K-12, PN 10, as per IS: 9523 / 2000 with inside cement mortar lining and outside Zinc coating with finishing layer of Black Bitumen, such as bends (any type radius & angle) tapers, tee pieces, single branches, Y junctions, double junctions, connecting pieces, Nuts & bolts, gaskets, flanges, including push on rubber joints etc. complete all as specified and directed.
Supply, installation, commissioning and testing of centrifugal type (pump set with suitable capacity 3 PH motor ) capable of delivering 250-110LPM at 24-36 MTR head directly coupled with suitable capacity of electric motor 3 phase 415V 3000 RPM rating as per the recommendation of manufacture of pump set, The foundation size as per OEM Recommendation Providing new RCC foundation (minimum height of foundation from GL 0.8 mtr) , base plate made from 6 mm thick iron plate/ angel suitable size as per OEM , iron angles frame , anti vibration pad ,nut bolts washer for holding to pump with motor , with "0" vibration of pump set, including necessary electrical connection and water connection & inlet outlet testing complete all as specified and directed.
Supply and Laying, PVC insulated and FR PVC Round Sheathed, Copper Conductor conforming to IS: 694 PVC insulated 1100 volt grade heavy duty electric cables with copper conductor , cross sectional area 4 sqmm 4 core complete all as specified and directed.
M&L for Disconnecting the existing 100, 150, 200mm GI/CI/DI pipes ,suction and delivery of any type from the pump set/ Existing pipe over / under ground and supply and fixing new pipe given in schedule including cutting, welding or lead or any other types joint nominal dia up to 200 mm joints complete for delivery and side including necessary nuts bolts , welding works and rubber etc., all as specified and directed
M&L for construction of stand post in cutting of GI/DI pipe of 100/150 mm size including of reducer, welding/ jointing clamp and 40 mm gun metal globe valve complete all as specified and directed.
S&F Foot Valve conforming to IS 4038, 50 mm dia flanged end and rubber gasket , leather Jip and complete, with stainless steel nut bolt rust proof, including jointing material such as rubber gasket,,etc. complete all as specified and directed.
M&L for road cutting , pavement , hard standing by using cutting machine and making good using cement mortar (1:2:4) given in schedule of laying of pipe up to 200 DI Pipe pipes given in schedule complete all as specified and directed.
Supply, installation, testing and commissioning of indoor cubical type LT Control Board, factory fabricated CPRI type tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-43 & general construction confirming to IS-13947, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 2.0 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50 x 50 x 6 mm angle iron suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl PCC platform/plinth of suitable size complete all as specified & as directed with & incl the following accessories :- (Pump Control panel) Item continued as 18.93
EXTERNAL ELECTRIFICATION S&F factory fabricated (CPRI type tested) weather proof, dust & vermin proof street light junction box of size 250 (L) x 250 (B) x 150 (D) mm (minimum dimensions) made up of 3.15 mm thick CRCA sheet, powder coated after preparation of surfaces comprising of 04 Nos aluminium bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators with provn of 01 No MCB SP 6 Amps, 10 KA breaking capacity, "C" curve & two openings at the bottom & one opening at the top with cable glands & fixing with the help of suitable sized MS clamps to steel poles incl testing complete all as specified and directed. (For Post top lantern)
Supply, erection, commissioning and testing of High Galvanized Mast Light 16 Meter High suitable for 6-9 Nos 200-210 W LED Flood light (to be paid separately under relevant item) and having three point suspension system with steel wire rope of 6 mm did and double drum winch with luminaire mounting arm, 01 No. twin LED type aviation obstruction light including lamp, lightning arrestor spike, power tools including lamp, including excavation for RCC foundation complete with following and all as specified and directed :- (a) High mast fabricated from steel plates conforming to BSEN-10025/IS:5986, cut and folded to from a polygonal section. Mast shall be in two sections for 16 mtr heights having only longitudinal weld conforming to BS-5135/AWS. The mast is to be provided with a fully penetrated flange which shall be free from any laminations or incursions. The welded connection of the base flange shall be fully developed to the strength of the entire section. The base flange shall be provided with supplementary gussets between bolt holes to ensure elimination of helical stress concentration. For environmental protection of the mast, the entire fabricated mast shall be Hot Dip Galvanized (As per IS:2629) internally and externally having uniform thickness of average 86 microns for bottom / top sections respectively and certificate from the OEM regarding the same to be submitted alongwith the PV and test certificates. The minimum size 410 mm bottom, 150 mm top, 4 / 3 mm section thickness, PCD 490 mm with base plate of 570 X 25 mm with 2 wire rope system and accessories. include Head frame, Lantern ring with 6 nos. of lum arms (symmetrically arrangement), wire ropes, powertool, AOL bracket and 1 set of Foundation Accessories, each set consists of 8 nos.of M 30 x 850 mm bolts with Anchor plate and 10 % templates. Item Continued as Ser No. 18.96 to 18.98
(b) An adequate door opening shall be provided at the base of the mast. The opening shall be such that it permits clear access to equipment’s lich winch, cable, wire rope, plug and socket etc. and also facilitates easy removal of the winch for servicing. The door opening shall be complete with a close fitting vandal resistant allen key locking with provision for external lock. The door opening shall be carefully designed and reinforced with adequate steel section so that the mast section at the base is unaffected, and undue buckling of the cut portion is prevented under heavy wind condition. (c) Mast structure shall sustain as assumed maximum reaction arising from wind speed as per IS-875 (Part-3) 1987 (three seconds) which is measured at a height of 10 mtrs above ground level. (d) The high mast shall be provided with accessories which include a raising and lowering system (R&L), trailing cable, power tool, lighting finial and aviation obstruction warning light. (e) The wire ropes shall be of stainless steel grade AISI 304 with minimum 6 mm diameter and 7/19 construction. Its central cores shall be also SS and have a minimum breaking strength of 2400 Kgs. The power tool shall be integral type suitable for handling the total head load. It shall have a mechanical torque limiter to ensure safety and also a manual handle shall be provided.
(f) Earthing 04 Nos. (02 for FP Box and 02 for High mast) complete with Galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below ground level with the top edge of the earth plate not less than 1.5 mtr below ground level and connected to galvanized iron earth lead strip 32 x 6 mm upto the required length by means of bolts, nuts, check nuts and washer of galvanized iron including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) precast RCC cover slab including one handle made out of 8 mm dia round bar embedded in precast slab and 20 mm bore medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as shown in EP No. 3 of SSR Part-I and testing on completion complete all as specified and as directed. (g) One number heavy duty hot dip galvanised finial shall be provided for the mast. The lightning finial shall be minimum 1.2 Mtr in length and shall be provided at the centre of the head frame. It shall be bolted solidly to the head frame to get a direct conducting path to the earth through the mast. The mast body acts as a conductor and earth Strip shall be connected to the mast door stiffener.
(h) Earthing 01 No. (for Surge protection device) complete with Galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below ground level with the top edge of the earth plate not less than 1.5 mtr below ground level and connected to galvanized iron wire 4 mm dia upto the required length by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) precast RCC cover slab including one handle made out of 8 mm dia round bar embedded in precast slab and 20 mm bore medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as shown in EP No. 3 of SSR Part-I and testing on completion complete all as specified and as directed.
S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimensions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 24 mm dia, pitch circle dia 250 mm, bolt length 750 mm, projects bolt length 125 mm , with Single type arm bracket 1500 mm long, top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding complete all as specified and directed.
S&F aviation light neon lamp 75 VA step up transformer heat resistant clear glass accessories, voltage 230 v AC or 24 V DC dual power operation , 50 HZ,IP 65, Cast aluminium , clear glass or polycarbonate dome, red colour complete all as specified and directed.
S&F LED Solar street light fitting 30-36 Watt LED power made with high Effficiency Monocrystalline solar PV modules, Lithium Ferro Phosphate battery with in built BMS technology, High efficiency LED,MPPT Solar charge controller and Aluminium Extruded body with dusk down sensor including 7 mtr octagonal galvanized steel pole and clamps for mounting and painting on pole complete all as specified and directed. NOTE : Excavation & earth work shall be measured and paid under relevant schedule.
Supply, installation, testing and commissioning of OEM Type Automatic Power factor control panel (Var SeT APFC panel) to improve power factor upto 0.99 or unity of capacity 400 KVAR with (2X5Kvar+2x10Kvar+2x7.5Kvar+ 2x12.5kVAr+ 2x15Kvar+2x25Kvar+ 3x50kVAr+1x100Kvar) and suitable size of MCCB's or MCB's 10KA 'C' curve indoor type floor mounted self supported front and rear openable double door hinged type with locking arrangement, suitable ventilation on both sides with wire mesh, IP-42 protection, dust and vermin proof, fabricated out of 2 mm CRCA sheet, powder coated with chemical process, mounted / fixed on and including MS angle iron stand / frame 40 cm height above FFLwith angles of size 50 x 50 x 6mm duly painted with black synthetic enamel paint over a coat of red oxide primer, PCC 1:3:6 type C1 foundation for grouting angle frame, control wiring with copper stranded conductor PVC insulated FRLS cables not less than 1.5 Sqmm, suitable size / capacity of copper strips for switch gear connection from main bus bar, earth bus bar strip of 32 x 6mm for entire length of panel, suitable size MS glands with gland plate and aluminium lugs / thimbles for all incoming / out going cables etc. Capacitor-duty contactors are rated based on nominal reactive power and Power contactors are rated based on the rated operational current and also use Two CL110, fixed in predefined locations in the Capacitor Bank, are paired with Zigbee-equipped PAS800 to communicate temperature and humidity values. Note:- All the Switchgear Capacitor, Capacitor Duty Contactor and Sensor Should be Same Manufacturer. Capacitors shall be continuous super heavy-duty type. The capacitor element shall have metallized polypropylene film (MPP) having low-loss dielectric, impregnated to high dielectric constant, low viscosity and high chemical stability. The capacitor unit shall have over pressure dis-connector protection. Item Continued as Ser No. 19.03
S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm buried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint ( HT cable 11 KV or LT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 Volts grade complete all as specified and directed (For street light )
Supply, installation, testing and commissioning of outdoor type LT Panel of suitable size, floor mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories all as specified and as directed : Main Panel Item Continued as Ser No. 19.07 to 19.08
OUTGOING :- (a) ACB, 1000 Amps, 50 kA, 4 pole, rated operational voltage 415-690 V, Manual draw out (MDO) type microprocessor release with LSIG protection unit with over current, short circuit and earth fault protection with LCD display with the manual setting nobs & current measurement on screen and battery back up with over temperature protection and indication for protection unit shunt trip, under voltage release, Terminals, dedicated slots for releases,In Built Temperature Protection, Ics=Icu=Icw rated impulse withstand voltage 12 kV - 01 No.. (b) MCCB 4P of capacity 500 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release & lcs=100 % lcu -03 Nos.(01 Spare) (c) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release & lcs=100 % lcu -03 No.(01Spare) (d) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos.
Supply, installation, testing and commissioning of out door type LT feeder piller box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door with 4 side slanting canopy duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories all as specified and as directed. (FP-01) Item Continued as Ser No. 19.10 to 19.11
OUTGOING :- (a) MCCB 4P of capacity 320 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release & lcs=100 % lcu -01No (b) MCCB 4P of capacity 63 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -02 No( 01 Spare). (c) MCCB 4P of capacity 16 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -01 Nos (d) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos
Supply, installation, testing and commissioning of out door type LT feeder piller box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door with 4 side slanting canopy duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories all as specified and as directed : Feeder Panel-2 Item Continued as 19.13 to 19.14
OUTGOING :- (a) MCCB 4P of capacity 25 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -04 Nos (01 Spare) (b) Danger notice plate of size 25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos
Supply, installation, testing and commissioning of out door type LT feeder piller box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door with 4 side slanting canopy duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories all as specified and as directed : Feeder Panel-3 Item Continued as 19.16 to 19.17
OUTGOING :- (a) MCCB 4P of capacity 320 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release & lcs=100 % lcu -02 No (spare-01) (b) MCCB 4P of capacity 63 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -02 No (spare-01) (c) MCCB 4P of capacity 25 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -02 No (spare-01) (d) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos
Supply, installation, testing and commissioning of out door type MPCP box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door with 4 side slanting canopy duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories complete all as specified and directed : (Feeder -04) Item Continued as 19.19 to 19.20
OUTGOING :- (i)MCB 4P of capacity 10 Amp breaking capacity 10 KA , 415 volts 50 C/S, AC-04 Nos (1 Spare) (ii) DOL Starter 3 HP , Relay range 4-6.5 Amp-02 Nos (iII) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos
Supply, installation, testing and commissioning of outdoor LT Panel of suitable size, floor mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories all as specified and directed. (DG Panel) Item Continued as 19.22 to 19.23
OUTGOING :- (a) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release & lcs=100 % lcu -01 No. (b) MCCB 4P of capacity 320 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -02 Nos.(01 spare) (c) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 25 KA with thermal magnetic release & lcs=100 % lcu -02 No( 01 Spare). (d) MCCB 4P of capacity 16 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -01 No (e) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-02 nos
HT SWITCHGEAR:- 11 KV, Non -extensible 2 WAY Non- Extensible RMU compact switchgear consisting of 1 no's direct Module (LBS) and 1 No Fixed operated Manual charging & closing) 11 KV/630 Amps VCB in SF6 insulated stainless steel enclosure with series trip, self-powered microprocessors numerical over current and earth fault relay protection, HT cable/Bus Bar , and one metering module with necessary CTs and PT and digital panel mounted multifunction meter with class 1.0 accuracy, comprising the following:- (Complete unit is to be installed inside CSS, protection accessories , Enclosure : Metal Clad, IP-54 Protection. Protection Relay: Self Powered Alfa numeric LCD display type. Internal arc tested for 1 sec, Fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows: - Rated Voltage - 12 KV , Rated Frequency - 50 Hz., Rated continuous current rating - 630 Amps. , Rupturing capacity of VCB --350 MVA, Rated Interrupting Current - 21 KA. , Rated making current for VCBs- 52 KA. , Rated making current for Isolators - 62 KA. , Rated short time current for 3 sec - 21 KA ARC 1 Sec, Operating duty - O-3min-CO -3min.-CO , Power frequency withstand voltage - 28 KV , Impulse withstand voltage - 75 KV , Busbar rating - 120% of continuous current., Operation: Spring closing mechanism - DC motor operated with 24-volt supply, Breaker Closing - Manual & Electrical through TNC switch., Shunt Trip coil - 24 V DC, Safety Interlock Locking facility - Required., Breaker panel indication - ON (Red) OFF (Green)
Accessories: 1 No. Self Powered Relay, Mechanical counter, Space Heater with Thermostat, Fuse and ON/OFF Switch, Aux relays for remote trip/indication for PC interface etc., cubicle illumination lamp LED 5 watt retrofit type 230 V AC, T-N Switch, Anti pumping contractor etc. In addition to the above all standard fittings to be provided as per IS norms Mimic Diagram: An operating mimic diagram shall be provided on the front side of each cubicle. Note: - Circuit breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM. The installations, calibration and testing of SF-6 circuit breakers will be conducted in the presence of authorised representative of OEM by the Contractor. Battery bank with charger for RMU is included in the item rate and rating of battery as described by OEM.
Transformer :- 11KV/.433KV OIL TYPE TRANSFORMER OF 1250KVA Oil filled Type 3 phase, 50 Hz, Dyn11, ONAN type Sealed type Copper wound Transformer with On Load Tap Changing Arrangement on all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc. preferably DMCR Protection Relay i/c first filling of filtered mineral oil and confirming to IS 1180 and losses shall be as energy efficiency Level 3 only & 100% load 3 phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc. shall be strictly in accordance with IS 1180 Part - 1 only. Heat Run Test is the mandatory test for each Transformer. (Make: Schneider/ABB/Siemens) Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern. • IS 2026 Standard for Oil filled Transformer • IS:3639 for Fittings and Accessories • IS:2099 for Bushings > 1000 V • IS:7421 for Bushings < 1000 V • IS:1271 for Electrical Insulation classified by Thermal stability • CBIP Guidelines CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: - a. Transformer shall be of BOLTLESS core design b. Core shall be purchased Directly from Manufacturer or from their accredited MaCORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability
Marketing organization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer. c. Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following
Documents i. Invoice of the supplier ii. Mill’s test certificate iii. Packing list iv. Bill of landing & Bill of Entry certificate by customs d. Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns. e. Core shall be procured from one of these reputed Manufacturers – Posco / Nippon/ Novex/ Ak Steels. f. The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint. Winding: a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).
The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit. b) Winding shall be carried in dust free area c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation. Oil type: TransformerTransformer oil shall be as per IS-335:1993. mineral oil with insulation class A. Temperature Indicator: One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip.Temperature Rise: The maximum temperature rise at the specified maximum continuous output shall not exceed 35°C by thermometer in the hottest portion of the oil or 45°C measured by resistance of winding above ambient temperature of 50°C.Adequate fan cooling is required during peak summer. Each transformer shall be provided with Off circuit Rotary type tap Switch so as to provided for a voltage adjustment on H.V. from +5% to –5%(In steps of 2.5%) of rated voltage of 11000 volts in 4 equal steps (5 position) to obtain rated voltage of 433 volts on LV side. Insulating material shall be of proven design. The insulating materials shall be class “A” for ONAN Cooling : ONAN Vector Group : DYn 11 Percentage Impedance (Z%) 6.25 %. Transformer Losses: as per IS 1180 - Level II
Supply, installation and testing of Astronomical Time Switch alongwith CRCA sheet enclosure IP-65 415 V, 03 Phase, 16 A including Contactor Digital time switch with astronomical function for switching on/off lights and other electric devices according to the rising/setting of the sun with combination function for creating switching programs in which the devices are switched according to astronomical time and/or fixed preset times, daily astronomical calculation of the sunrise/ sunset times based on the entered loc complete all as specified and directed.
DG SET Supply, installation, testing and commissioning Silent type built in within an acoustic enclosure Diesel Engine driven Generating set water cooled including AMF panel for standby power supply 415 volts, 3 Phase, 4 wire, 50 cycles / sec,0.8 power factor, 500 KVA (400 KW) or next higher standard size available KVA,1500 RPM. Self excited self regulated brushless AC generator installed. The alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter 12 volt. Acoustic enclosure suitable for ambient condition at Siliguri area and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 to meet exhaust emission test as per revised MoEF norms/as per CPCB -IV plus or as per latest. Fuel tank capacity not less than 08 hours fuel requirement & battery as recommended by OEM battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based gen-set controller governor with the following under-mentioned features & all as specified & as directed :- Note :- The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. Item Continued as Ser No. 19.36 to 19.44
(A) Alternator :- Standard design alternator rated at 500 KVA/ nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire, 415 volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequency regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. (i) Insulation class - 'H' (ii) Temperature rise Class - 'H' (iii) Excitation : Self Excited (iv) Regulation performance: The voltage is kept constant with + 1%. (v) Frequency regulation + 1% (B) Diesel Engine: - Adequate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete, with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
(i) Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts. (iii) Cooling Water pump : - Centrifugal type belt driven. (iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. MS Exhaust pipe with bends/flanges and all accessories to be supplied and erected as per OEM recommendation. The Exhaust Pipe shall be insulated with low resin bounded wool of min 75 mm thickness min 144 Kg/m density. The dia/thickness and Stack height of the Exhaust pipe shall be as per OEM recommendation and CPCB norms. The minimum height of Stack to be provided with each generator set shall be worked out as per latest CPCB norms. Turbo charger type Exhaust manifold Silencer : Residential type
(v) Fuel System :- Diesel Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governor electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Comprising with Fuel Filters and Fuel Hoses. (vi) Lub oil System :- Comprising of Lubricating oil filter, Lubricating oil pump etc. (vii) Air Intake System :- Air intake Manifold, Air cleaner dry type etc. (viii) Governor : - Electronic type (ix) Starting System :- Electric Self starter with and including battery charging alternator 12 Volts DC. (x) Batteries :- Batteries of maintenance free 180 AH - 02 Nos of voltage as per OEM complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified. Start and stop push button Ignition key / Switch Radiator with blower fan & first fill of coolant oil Corrosion inhibitor coolant (xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.
(xii) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine. (xiii) Coupling arrangement : - Flexible coupling (xiv) Accessories :- AVM Pads built- in or separately mounted to manufacturer base frames. (xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer. (xvi) Fuel Tank :- Daily service fuel tank made complete on a common base inside the acoustic enclosure as per manufacturer guidelines for min 8 hrs continuous operation. (xvii) MS/Steel flexible pipe line to and from the fuel tank to the DG Set. (xviii) Battery Charger shall be provided as per manufacturer guidelines (xix) The DG Set shall comply to the emission limits requirement as per Govt of India CPCB -IV plus or as per latest. The DG Set shall be complied with all test requirements as stipulated in the gazette notification. All relevant test results from NABL accredited lab shall be produced.
(c) Digital Frequency meter - 1 No (d) Digital KW meter - 1 No (e) Digital KWH meter panel mounted type - 1 No (f) Digital PF meter - 1 No (g) Annunciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temperature. (iii) Engine over speed. (iv) Battery low voltage. (v) Over voltage, under voltage and over current (vi) Display shall be alphanumeric LCD display with LED backlight. Controls and Records:- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button (e) Fault accept / reset push button (f) Battery Charger shall be provided as per manufacturer guidelines (g) Suitable to provide a record of most recent fault conditions & fault history. (h) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA , frequency etc.
(j) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. (k) Control including provn of service adjustment & calibration of DG control functions. (D) Civil Works :- All civil works including PCC plat form and related foundations including for panel and equipments including making good of disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer. Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer. (E) Acoustic Enclosure:- Manufactured by OEM suitable for 500 KVA DG Set. (i) Tested by NABL approved lab as per CPCB-IV Plus or as per latest (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating set battery should be inside the enclosure. (iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 8 hrs continuous operation. If required contractor may arrange outside fuel storage capacity to achieve this
(v) Construction Details/specification are as follows : - (a) Outer body :- CRCA Sheet of 1.6mm thick. (b) Doors :- CRCA sheet of 1.6 mm thick (c) Sound Insulation :- 100 mm thick rock wool (minimum density 64kg/Cum)/ fire resistance foam/puff as per OEM/ as per standard manufacturing to achieve desired decibel level (vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The DG Set should be provided with external Emergency stop push button. (viii) The enclosure should be suitably internally illuminated by CFL/FTL Lamp fittings. (ix) The noise level should be 75 dB at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre-treatment process. The base frame should be painted with epoxy based black shade.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed.
Supply, install and commissioning of new factory made microprocessor controlled air cooled variable refrigerant flow type air conditioning system consisting modular type outdoor units equipped with highly efficient full inverter scroll compressors not less than two units (all compressors will have to be inverter type), special acryl precoated / blue fin heat exchanger, low noise condenser fan, The Outdoor and Indoor units shall be integrated with special super wiring system with LCD display into one common wiring circuit from the indoor control arrangement including refrigerant gas of R410A and piping system, complete suitable for refrigerant R410A or equivalent non-CFC type and including all structural MS frame work PCC platforms required of capacity 40 TR to maintain a temperature range 22 degree +/- 2 degree Celsius complete all as specified and as directed. Item continued as 19.51
S&F wired remote control unit suitable for central room wise control for all cassette type units installed in all individual rooms together with LCD display and self diagnostic features complete all as specified and directed..
Supply and installation of refrigerant copper piping 41.30 mm (outer dia) with 19 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 34.90 mm (outer dia) with 19 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 28.60 mm (outer dia) with 19 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 25.40 mm (outer dia) with 19 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 22.20 mm (outer dia) with 13 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 19.10 mm (outer dia) with 13 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 15.90 mm (outer dia) with 13 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 12.70 mm (outer dia) with 10 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
Supply and installation of refrigerant copper piping 9.50 mm (outer dia) with 8 mm thick Nitrile Rubber Tubular insulation including suitable joints / branch connectors and distributers for indoor & outdoor units as required at site complete all as specified and as directed.
S&F perforated cable tray 150mm (W) x 50mm (D), made of 1.0mm thick plain Galvanized steel sheet, for laying of the XLPE cable, sub main Wiring, copper tubing etc. including all supports, brackets, clamps, nuts & bolts etc. all as specified and as directed
S&F perforated cable tray 250mm (W) x 50mm (D), made of 1.0mm thick plain Galvanized steel sheet, for laying of the XLPE cable, sub main Wiring, copper tubing etc. including all supports, brackets, clamps, nuts & bolts etc. all as specified and as directed
S&F perforated cable tray 300mm (W) x 50mm (D), made of 1.0mm thick plain Galvanized steel sheet, for laying of the XLPE cable, sub main Wiring, copper tubing etc. including all supports, brackets, clamps, nuts & bolts etc. complete all as specified and directed.
S&F PVC insulated heavy duty copper conductor 2.5 Sqmm, 2-Core, working voltage 1100 volts conforming to IS: 1554 part -I, drawn through pvc conduit for VRF System complete all as specified and directed. NOTE : PVC conduit with conduit accessories shall be measured & paid separately.
S&F PVC insulated heavy duty copper conductor 2.5 Sqmm, 4-Core, working voltage 1100 volts conforming to IS: 1554 part -I, drawn through pvc conduit for VRF System complete all as specified and directed. NOTE : PVC conduit with conduit accessories shall be measured & paid separately.
S&F PVC insulated heavy duty copper conductor 4.0 Sqmm, 4-Core, working voltage 1100 volts conforming to IS: 1554 part -I, drawn through pvc conduit for VRF System complete all as specified and directed. NOTE : PVC conduit with conduit accessories shall be measured & paid separately.
M&L for communication/ shielded cable of 1 Sqmm 3 Core for connecting of AC plants complete all as specified and directed.
Supply, installation, testing and commissioning of out door type LT feeder piller box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper looking arrangement in both front and rear door with 4 side slanting canopy duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on suitable PCC platform & necessary foundation complete with the following accessories all as specified and as directed. Item Continued as 19.71 to 19.72
OUTGOING :- (a) MCCB 4P of capacity 125 Amps, 415 Volts, 50 Hz, breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu -02 No (spare-01) (b) MCCB 4P of capacity 32 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 16 KA with thermal magnetic release & lcs=100 % lcu - 02 Nos (c) MCB TPN of capacity 32 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 10 KA with thermal magnetic release & lcs=100 % lcu -05 No (d) Danger notice plate of size25 x 20 cm of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red color and fixed with MS clamp and bolt and nuts of approved size for LT conforming to lS:2551 complete-
SECURITY WALL, FENCING & GATE S&F Concertina coil 600 mm dia fix over angle section complete all as specified and directed.
SEWAGE TREATMENT PLANT (STP) Designing (hydraulically, structurally & aesthetically), providing,constructing, hydraulic testing,commissioning and giving satisfactory trials of Pakaged Sewage Treatment Plant of capacity 10 KLD FRP based on any suitable technology of Sewage treatment with online continuous monitoring system consisting of Inlet chamber(RCC), Fine bar Screen chamber (manual) RCC with steel screen, Oil & Grease Remover(RCC), Grit separator, Equalization Tanks, Air Grid for Equalization Tanks, Feed Pumps(2 No), Sludge Drying Bed of appropriate size, Chlorine Dozing System, Chlorine contact tank, Foundation for all E/M equipments, Associated piping work with required valves, gates, drains, pathways, Electrical control Panel with interconnecting cable, spare parts for 2 years of operation, etc. complete as turnkey job with all involved civil, electrical, digital and mechanical works as per detailed specifications for civil, electrical and mechanical components with all duties and taxes complete with tertiary treatment including Filter Feed Tank of RCC, Filter Feed Pumps, Dual Media Filter, Activated Carbon Filter, Treated water Tank in RCC including tertiary treatment and all necessary civil work for installation. Treated sewage shall be used for irrigation, horticulture, fire fighting and MT wash of capacity 10 Cum/day. The following specifications shall be considered during design of the STP :- Item Continued as 19.75 to 19.78
(a) BAR SCREEN MOC: SS 304 Fine screen mesh size: 6 mm Type Mqanual-01 No (b)RAW SEWAGE PUMP Type: Sewage Submersible Type, Head: 10 m or as per design Flow: 0.5 m3/hr or as per design, HP: minimum 1 HP Phase: Single or Three Phase as per design (1 W+1 S)=02 (c)FLOW METER Type: Online float type Rota meter Capacity: 0-1000 LPH (d)Membrane: Submerged Hollow fiber membrane as per design. MOC of fiber: Reinforced PVDF or as per design. MOC of membrane stand: SS – 304 (e) MEMBRANE FILTRATION PUMP Type: Centrifugal pump, Head:18 - 20 m or as per design Flow: 0.6 m3/hr or as per design, HP: 0.5 to 1 HP as per design, Single or Three Phase as per design (1W+1S)=02 (f) MEMBRANE BACKWASH PUMP Type: Centrifugal pump as per design (1W+1S)=02 (g) Air Blower Type: Twin Lobe Root Capacity as per design and OEM Recommendation. (1W+1S)=02 (h) ANOXIC MIXER Type: Motor, Gear Box with Impeller MOC: SS 304 RPM: 20 RPM HP: 1 HP or as per design -01 No (j) AIR PIPING Non submerged piping: MSEP / GI/ uPVC Submerged piping: uPVC -01 lot (k) LIQUID PIPING Non submerged piping: uPVC - Sch – 40 Submerged piping: uPVC - Sch - 40 -01 Lot (l) CONTROL PANEL Type of panel: Automatic panel of PLC base Housing: MS with Powder Coating 1 Mode of operation: Automatic / Manual -01 No
(m) SKID MOC: SS 304 Dimension if Skid: As per final size of membrane-as per design and recommendation of OEM (n) DISINFECTANT DOSING SYSTEM Dosing pump, Capacity of Dosing pump: 0 - 4 LPH or as per design Dosing tank capacity: not less than 50 Lit Dosing tank MOC: LDPE-01 No (o) CEB/CIP DOSING SYSTEM Dosing pump 0 - 4 LPH or as per design, Dosing tank capacity not less than 50 Lit Dosing tank MOC: LDPE as per recommendation of OEM (p) DIFFUSER Type: Disc membrane diffuser -3 Nos (q) SOLENOID VALVE Type: ON/ OFF type, NC Valve MOC: Nylon/ SS - 304 - 1-02 Nos (r) PRESSURE GAUGE - 4 Nos or as per design. (s) VACUUM GAUGE Range: 0 - 1 kg/cm2-01 or as per design (t) CENTRIFUGE Capacity: 12 Kg/Batch Size: 12 mm Dia or as per design MOC: MSEP- 01 No (u) LEVEL SENSOR Type: Ultrasonic Type, Depth range: 1m to 5m Output Type: 4-20 mA or as per design -01 No (v) LEVEL CONTROLLER Type: Float type level sensors Cable Length: 3m - 02 Nos as per design (w) Flow Transmitter cum Totalizer Type: Magnetic Type Flow Meter Line Size: 1” - 02 Nos as per design. (x) Anoxic Tank Capacity: 1 KL MOD: MSFR - 01 No (y) Aeration Tank Capacity: 3 KL MOD: MSFR - 01 No (z) MBBR Tank Capacity: 1.5 KL MOC: MSFRP -01No (aa) RCC Treated Water Tank Capacity: 2 KL - 01No
(m)Module Mounting Structure: Design, procure, fixing, support structure made of hot dipped galvanised iron with min 85 micron thickness including necessary PCC foundation and associated work and fixing mounting arrangement suitable for SPV modules so as it can withstand wind speed of 150km per hour. The array mounted structure has to be so designed that it occupies minimum space without sacrificing the output of SPV panels, Nuts, bolts, mounting structure including module mounting structure shall have to be adequately protected from atmosphere and weather prevailing in the area. All the modules fixing fasteners shall be of stainless steel of grade SS316.The module mounting structure to be fixed tilt to optimise the maximum generation in a year. MMS design shall be supported with staad pro report and submitted for the approval of the accepting officer. Cost of all equipments, copper strip up to earth test point and copper earthing etc. are included in this item. The cost of sufficient earthing for lightning protection is included in this item and no extra payment will be made to the contractor on this account.
(n)String Inverter: Procure, fixing, testing and commissioning of 10 KW , 50+3 Hz (min) 3 phase 460 volt, THD< 3%, at nominal power inverter suitable to convert DC power of solar PV module/array/ to AC for further feeding to grid confirming to IEC 61683 for efficiency, IEC 62109 or equivalent for safety and IEC 62093 for reliability. The input DC technical specification of 10 KW inverter are as under: Input (DC) DC V voltage Range: 575-850 V Max DC Voltage:1000 V Nominal Power : 10 kW Max output power : 10 kW Nominal AC current : as per standards Nominal output voltage: 460V Output Frequency : 50/60 Hz Harmonic Distortion current : < 3% Efficiency : 98.3% Standby operation consumption (feed in) : < 20 W
Civil work for Blower, Room, RCC Bar Screen Chamber Size: 500 x 500, RCC O&G Trap Size: 1000 x 1000 ,RCC Collection Tank, RCC UG Sump 5000 Ltrs , Piping work ,electrical work etc. complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
TD_DRGS.rar
Additional Documents • 5.96 MB
Complete_tender_except_BOQ_98737.pdf
Tender Documents • 4.75 MB
BOQ_838872.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid