| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-I₹7.3 LAccepted-AOC GOVT CONT V P O LEDA TEHSIL BALH DISTT MANDI | MANDI | HIMACHAL PRADESH | 175001 | L-I | Accepted-AOC Bidder quoted lowest amount hence work awarded | |
| 2 | L-II₹8.0 LRejected-Finance HIMACHAL PRADESH HP | L-II | Rejected-Finance Bidder quote highest amount |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
29 Aug 2022, 2:00 pmClosed
Sh. Munish Sahni, Deputy General Manager
RTDC, US, Club, Shimla-1
Special repair of RTDC Office at US Club Shimla SH Repair of Existing old building 7 rooms opposite side of director office and 4 Rooms Adjacent to CGM Office room
2022_RTDCH_63925_1
RTDC/SSCL/2022/11172-73 dt 20/08/22
Open Tender
Construction Works
Item Rate
30 days
US Club Shimla
Read RFP for complete details
5 documents required · 5 mandatory
₹413
Yes
DEPUTY GENERAL MANAGER RTDC HP
₹14,000
Yes
2 Feb 2023
22 Aug 2022
29 Aug 2022
22 Aug 2022
29 Aug 2022
22 Aug 2022
Amount
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shad all Complete as per direction of Engineer-in-Charge.
Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. Of approved manufacturer and of required shade and colour complete. as per manufacturer’s specification. One or more coats on old work as per direction of Engineer-in-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per direction of Engineer-in-Charge.
Repair to plaster of 12mm to 20 patches of area 2.5 sqm and under, including cutting thepatch in proper shape, raking out joints and preparing plastering the wall surface with white cement based modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer- In-Charge.
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) 12 mm thick as per direction of Engineer-in-Charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m² as per direction of Engineer-in-Charge.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood as per direction of Engineer-in-Charge.
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc as per direction of Engineer-in-Charge.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-incharge. 35 mm thick shutters
P/L cement concrete - all works upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as per direction of Engineer-in-Charge.
P/L rectified Glazed Ceramic floor tiles laid on 20mm thick cement mortar (1:4) as per direction of Engineer-in-Charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge15 mm nominal outer dia Pipes as per direction of Engineer-in-Charge.
Providing and fixing C.P. brass bib cock of approved 15 mm nominal bore (In All Bath Rooms) as per direction of Engineer-in-Charge.
Providing and fixing PTMT pillar cock of approved quality and colour. In All Bath Rooms as per direction of Engineer-in-Charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good thewalls and floors wherever required In All Bath Rooms as per direction of Engineer-in-Charge.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap In All Bath Rooms as per direction of Engineer-in-Charge.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. In All Bathrooms
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. In All bath rooms as per direction of Engineer-in-Charge.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm In all Bathrooms as per direction of Engineer-in-Charge.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms as per direction of Engineer-in-Charge. In all Bathrooms
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. In all Bathrooms as per direction of Engineer-in-Charge.
Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated bracke 20 mm dia (heavy type) as per direction of Engineer-in-Charge.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 250x10 mm For all rooms as per direction of Engineer-in-Charge.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm For all Rooms as per direction of Engineer-in-Charge.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper For all Rooms as per direction of Engineer-in-Charge.
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete For all Rooms Door as per direction of Engineer-in-Charge.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. For All rooms as per direction of Engineer-in-Charge.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 110mm Bend as per direction of Engineer-in-Charge.
PVC Door Bend 110mm
Single Tee Without Door 110x110x110
PVC Plain Bend 75mm
PVC Plain Tee 75mm
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 as per direction of Engineer-in-Charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer-in-Charge.
Providing and laying of 2mm thick PVC /Rubber tiles flooring plain coloured corbed or mosaic or matted finish laid with approved adhasive on sub floor damp proofing treetment(to be measured separatly) for payment. Including carriage of material all lead and lift as per direction of Engineer in charge
Electrical Work
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required as per direction of Engineer-in-Charge.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required as per direction of Engineer-in-Charge.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC casing & capping along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required as per direction of Engineer-in-Charge.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, piano type switch, connections, painting etc. as required as per direction of Engineer-in-Charge.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Single door-4 way as per direction of Engineer-in-Charge.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Single pole. Cat-A as per direction of Engineer-in-Charge.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Double pole. Cat-A as per direction of Engineer-in-Charge.
Earthling with G.I. earth plate 600 mmx600 mix 6 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required as per direction of Engineer-in-Charge.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required as per direction of Engineer-in-Charge.
S/F Led Tube light of siesta or its equivalent approved make of complete with connections etc as required capable in all respects. Led tube 8 watt as per direction of Engineer-in-Charge.
S/F Led Bulk head of siesta or its equivalent approved make of complete with connections etc as required capable in all respects. Led Bulk head 12 watt as per direction of Engineer-in-Charge.
Providing and insstallation of 2no single bed for RTDC office (For Driver room) (including labour chagre and installations).
BALDEV THAKUR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .