| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC The lowest bidder | |
| 2 | L2₹43.1 L+₹2.3 L (5.56%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L2 | Rejected-Finance Not the Lowest Bidder | |
| 3 | L3₹46.3 L+₹5.5 L (13.5%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L3 | Rejected-Finance Not the Lowest Bidder | |
| 4 | L4₹48.7 L+₹7.8 L (19.2%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Not the Lowest Bidder | |
| 5 | L5₹49.0 L+₹8.2 L (20.1%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance Not the Lowest Bidder |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
10 May 2025, 6:00 pmClosed
GE (Army) Suratgarh
GE (A) Suratgarh
SPECIAL REPAIR TO BLDG NO SC-01 NEAR MAP-I, ADDN/ALTN TO A VEH GARAGE BLDG NO P-48, PROVN OF STORAGE ACCOMMODATION (PERMANENT STRUCTURE) AND OTHER SANCTIONED WORK UNDER GE (ARMY) SURATGARH AT SURATGARH MIL STN
2025_MES_704146_1
GE (A) SOG Token No -01/25-26
Open Tender
Civil Works
Item Rate
180 days
Suratgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(Army) Suragarh
₹91,000
Yes
11 Jul 2025
11 Apr 2025
12 May 2025
11 Apr 2025
10 May 2025
28 Apr 2025
Amount
Notes:- (i) 100 percent nonperishable items of the work shall be deposited by the L1 bidder within 30 days after placing of work order. (ii) The critical path network shall be submitted by L1 bidder immediately after the acceptance of tender and approved by GE. (iii) The bidders must ensure to visit the site, check relevant documents and makes of materials required to be incorporated under the subject from concern Engineer-in-Charge. (iv) The unserviceable material obtained under the schedule of credit shall be handed over to the contractor by the Engineer-in-Charge on a proper gate pass. (v) In case of non-availability of any make mentioned under list of Makes, the L1 Bidder shall obtain non-availability / non-manufacturing certificate from the concern OEM / authorised dealers and submitted to Accepting Officer, the L1 bidder may be incorporated makes as approved by HQ CE SWC Jaipur / HQ CE BTZ in the works after prior approval of Accepting Officer. (vi) L1 Bidder shall produce E-way bill alongwith test certificate from OEM / manufacturer for costly items / major items of amount above Rs 50,000/- along with RAR’s and Final Bill. (vii) L1 Bidder shall be maintained an album containing Photos of all the material brought at site and each stage wise work progress and kept at site. Same shall be deposited in Engineer-in-Charge office after completion of work. (viii) Suffficient tradesman, Labours needs should be employed by the bidder on daily basis and as required by Engineer-in-Charge. (ix) Main Items and fixtures, base materials shall be from the same manufacturer. (x) The cost of all the above provisions shall be deemed to be included in the quoted rate of bidder, nothing extra shall be paid to the bidder.
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Dismantling bricks (laid flat or on edge) or brick tiles on roof terrace, in floors, channels, kerbs, aprons etc laid dry or laid dry and pointed and removing from site complete all as specified & directed by Engineer-in-charge.
Taking down steel window / ventilator of any description and of any type with or without guard bars and making good the disturbed portion complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
Taking down chowkat or frame with shutters including fitting and fixtures area not exc 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
Taking down chowkat or frame with shutters including fitting and fixtures area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each (includig fitting and fixtures) complete all as specified and as directed by Engineer-in-charge.
Taking down and refixing door shutters of any description having area exc 1.00 sqm but not exc 2.00 sqm, each in the same opening complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Rough excavation not exceeding 1.5 m deep and getting out complete all as specified and directed by Engineer-in-charge.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed by Engineer-in-Charge
Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified & as directed.
M&L anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed.
M&L anti-termite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed.
M&L anti-termite treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified & as directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block, roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 design mix using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engineer-in -charge.
M&L for reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for providing reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate as in chajjas and the like complete all as specified and directed by Engineer-in-Charge.
M&L for providing reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate as in column, pillars, piers, posts and sturts complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
All as per serial item No. 30 here-in-above but except bricks. Note : Old serviceable bricks retrieved from serial item No 1 of BOQ here-in-before shall be used under this item.
M&L for masnory work with Autoclave Aerated Concrete (AAC) Blocks with approved adhesive/mix mortar, straight or curved on plan exc 6 m mean radius complete all as specified.
M&L for use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work exceeding 200mm thick (horizontal or sloping), rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to flat surfaces of chajjas, chullah hoods, troughs and similar items including edges for rough finished surfaces complete all as specified and as directed by Engineer-in-charge.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
M&L for Square, rectangular or polygonal use and waste of form work to sides pillars, posts, struts, pier, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exceeding 10cm wide but not exceeding 20cm wide, surface flat for rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for 35mm thick flush shutter solid core construction with block board core & ply wood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-charge.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be inclusive in this items) complete all as specified and directed by Engineer-in-charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S S screws shall be paid separately.
S&F 35mm thick factory made glazed and skeleton shutters made of second class hard wood (Bonsum/Hollock), open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Part I Section 8 Clause 8.24 (a) kiln seasoned and chemically pressure treated fixed to chowkat complete all as specified and directed by Engineer-in-charge.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick one side prelaminated PVC sheet reinforced with MS square tube and edges painted to match the prelaminated sheet complete all as specified & shown in relevant drawing of item No. 08095 to 8097 in MES Schedule (Part-II) and directed by Engineer-in-Charge
S&F 28 to 30mm thick (styles) factory made solid PVC moulded Door shutter, with 2, 4, or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm thick prelaminated PVC sheet on back face complete all as specified & shown in relevant drawing of item No. 8101 to 8105 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 200 mm long mild steel barrel tower bolt stove enamelled black with bright bolt (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size mild steel butt hinges cold rolled medium weight (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size butt hinges of extruded aluminium alloy with galvanized mild steel hinge pin, anodized type C-21 (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 300mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 150 mm long mild steel pressed handle, oval type, stove enameled black (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 150mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 55 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc complete all as specified and directed.
M&L for mild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer-in-charge.
M&L for steel work as in square / tubular trusses, purlins, post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 including painted with one shop coat of zinc chromate primer paint including preparation of surface at contractor workshop before fabrication complete all as specified and directed by Engineer-in-charge.
S&F factory made steel window with side hung shutters including projecting type hinges with steel handle, steel peg stay, fixing lugs etc complete with glazing bars including one shop coat of red oxide primer and Cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified & directed by Engineer-in- charge
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed.
S&F anodised aluminium frames powder coated (thickness of powder coating shall not less than 50 micron) for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium window / ventilators shutters powder coated (thickness of powder coating shall not less than 50 micron) side hung type, without sash bars having aluminium sections weighting 0.55 Kg/RM including necessary jointing cleats, glazing clips, anodised aluminium snap beading, screws, rubber neoprene packing including anodised aluminium fitting such as peg stay 150mm long (1 No), hinges type B21 100mm size (2 Nos), suitable handle (1No) complete all as specified and directed by Engineer-in-Charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F as in repair Anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross Tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM and 23.5mm x 26.4mm x1.40mm weighing 0.191Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mm x 15mm x 1.5mm weighing 0.12Kg /RM fixed with suitable MS bolts, nuts and washer. The snap grid (main /cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 35mm x 25mm x 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement duly suspended with 3mm dia GI wire length as required @ 600mm C/C with adjustable device including plugging in brick / concrete work with steel raw plugs including making good all the disturebed portion complete all as specified and directed by Engineer-in-Charge.
M&L for 4mm thick E board classic, fibre base cement boards, embosed texture, fixed to aluminium snap grid (size of grid 605mm x 605mm) in ceiling complete all as specified and directed by Engineer-in-charge. Note :- The aluminium snap grid frame work shall be measured & paid for separately.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab 18 to 20mm thick (minimum size 550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting, raiser of steps etc. laid over & including rendering 10mm thick in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for Roof treatment in as specified below and as directed (a) Cleaning the roof surfaces thoroughly using wire brushes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/ plaster etc complete. (b) Applying one coat of elastomeric PU based liquid membrane diluted with potable water in the ratio of 1:1 and apply @ 0.40 Kg/Sqm. (c) Laying polyster reinforced fiber net / 50 sqm Geotextile mesh, upto 300mm on walls. (d) Applying two coats of undilited PU based liquid membrane having Elongation more than 400%, Tensile strength more than 2N/mm2 and alkali & antifungal resistant maintaining thickness of 1.5mm with paint brush/ roller upto 300mm on walls. (e) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Note : (i) The treatment shall be carried out as per manufacturer instructions and as directed by Engineer-in-Charge. (ii) The plan area of floor shall be considered for payment.
Demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified and directed.
M&L for cleaning from roof and priming the surface with one coat of cold applied bituminious primer @ 0.40 Kg/Sqm conforming to IS:3384 and applying a layer of APP based polymeric membrane not less than 3 mm thick, weighing not less than 3.5 Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) and upper side of membrane thermally insulated with white gravel finish uniformaly embedded during manufacturing process. It shall be laid by torch application having side over lap 75 mm and at the end 100 mm, all overlaps and joints shall be sealed by torch application. The same shall be furnished by a membrane flashing.
M&L for cleaning of all loose dirt, dust, removing all existing bitumen coating, App membrane completely with intensive wire brushing or high speed water jet and surface should be free from any loose paint, dust or grease complete all as specified and directed by Engineer-in-charge.
M&L for running welding as in repairs not exc 2.5cm in length, thickness of metal to be welded exceeding 6mm and not exc 9mm complete all as specified and directed by Engineer-in-charge.
M&L for 18-20mm thick Granite (Z Black type south) slab of approved shade as in cooking platforms, steps, jambs, pillars, window cills and the like etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) over & including 15mm thick screed bed (bedding layer) in CM (1:6) complete all as specified and directed by Engineer-in-charge. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for 50 mm thick PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 50mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in flooring, finished even and smooth without using extra cement cement complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 300mm x 450mm x 7-8mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick vitrified ceramic light shade, double charge, ultra charged (as approved) coloured tiles (square / rectangular), polished, area of each tile not exceeding 0.36 sqm in floors etc, set and jointed with epoxy grout to match coloured to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick vitrified ceramic light shade, double charge, ultra charged (as approved) coloured tiles (square / rectangular), polished, area of each tile not exceeding 0.36 sqm as on vertical surfaces such as dado, skirting etc., set and jointed with epoxy grout to match coloured to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4 mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished fair & even, complete, all as specified. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for 10mm thick rendering in cement mortar (1:3) over concrete surface (Roof) mixed with water proofing compound 3% by weight of cement finished as per manufacturer’s instructions including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note : - Water proofing compound shall be included in this items. Nothing extra shall be paid on this account.
M&L for 15mm thick rendering in cement mortar (1:4) on fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:6) on fair faced surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 5mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint over a coat of cement base primer and filling cement based putty in cracks complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, filling cracks with wall care putty etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of oil bound distemper including Alkali resistant priming preparatory to distempering complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre / 10 sqm over and including one coat of primer applied @ 0.9 litre / 10sqm as per manufacturer instruction complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of appropirate primer over and including 2mm thick layer of ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old plastered surfaces like lime, distemper, plastic paint, cement base paint including scrapping down smoke soot, moulds, moss, efflorscent salts, trading oil, greasy spots using mechanical grinding machine and washing of old surface with water of wall, preparation of surfaces and applying two coats of oil bound distemper (OBD) over a coat of appropirate primer over and including 2mm thick layer of ready made wall care putty including sand papering after filling the putty to make surfaces smooth and ready for receiving painting complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing,scrapping down smoke soot mulds, moss and efflorescent, salts etc and applying two coat of cement based paint complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed.
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain / brass CPVC SDR 11 fittings and fixed complete to walls and ceilings or laid in floors, trenches complete all as specified and directed by Engineer-in-charge.
Supplying and laying of 25mm dia CPVC pipes SDR 11 & Plain / brass CPVC SDR 11 fittings and fixed complete to walls and ceilings or laid in floors, trenches complete all as specified and directed by Engineer-in-charge.
S&F as in repair 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F as in repair grating doom 125mm dia of PTMT with waste hole (minimum weight 40 grams) complete all as specified and directed by Engineer-in-Charge.
S&F as in repair rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 litres including PTMT float valve ball valve and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F as in repair 15mm bore angle cock, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. Make :- Jaquar Cat part No FUS-CHR-29053, Kohler Cat Part No 76390IN-9-CP or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F as in repair vitreous china wash basin white, flat back of size 550x400mm including a pair of cast iron brackets embedded in PCC 1:3:6 type C-1 blocks of size 10 x 7.5 x15 cm with & including 32 mm dia PVC waste pipe, 32mm dia PTMT waste coupling half or full thread (minimum wt 45 grms) flange end bedded in red lead cement & other end fixed to waste pipe and including brass chromium plated fancy type pillar tap, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F as in repairs vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
S&F as in repair 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge. Make :- Parryware Cat part No E8109 SLIMLINE ECONOMY, Hindware Cat Part No 509801, Cera Cat part No B1010112 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F as in repairs PVC waste pipe 32 to 40mm bore suitable for WHB or Sink complete all as specified and directed by Engineer-in-charge.
S&F in replacement 110mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F as in repair 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F as in repair 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge"
M&L for applying cement mortar 1:3 over a coat of neat cement slurry @ 3 Kg/Sqm and one coat of bonding agent as per manufacturers specifications complete all as specified and directed by Engineer-in-charge. Make :- Dr Fixit URP, Fosroc Nitobond, Sikka Hibond
M&L for a micro conrete mixed and poured as per manufacturer specificatios of thickness 40-50 mm as required and directed by Engineer-in-Charge. Make :- Dr Fixit URP, Fosroc Nitobond, Sikka Hibond
M&L for removing loose ceiling plaster completely, cleaning and dripping mortars and curing of effected surface area, cleaning well expossed reinforcement and applying two coats of anti-corrosive paint to it, supply and fixing mild steel XPM mesh of size 25mm x 25mm (wire dia min. 2mm) to the effected ceiling surface either by welding with exposed reinforcement or by stapling nails or screw or tie with reinforcement, applying cement slury and 25mm thick microphone of 1:1:1 using 6mm graded aggregate and cuting it for 3 days and then making well finish the surface using cement mortar 1:3 complete all as specified and directed by Engineer-in-charge.
Taking down carefully or drawn out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators, MCB, DB, lamp, earth plug etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for Modular point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated multistranded unsheathed copper conductor cable drawn in and including concealed PVC rigid conduit medium grade 20mm dia, pipe hooks, elbows, junction covers and junction boxes including cutting chases in walls for conduits and for sunken pressed steel terminal boxes and making good the disturbed surfaces of wall with all jointing accessories including provision of pressed steel sunken terminal boxes made of 1.2mm thick pressed steel sheet, 60mm deep of suitable length and painted with red oxide primer for mounting modular switches, sockets, fan regulator including suitable size modular plates fixed flush with wall including 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. Note : The quoted rate shall be deemed to included with modular cover plates with frame of any colour and metal flush boxes of suitable size as directed by Engr-in-Charge.
All as per serial item No.130 here-in-before but for One 3 pin 5 Amp socket outlet one light point controlled by one switch on the same board with other switches.
All as per serial item No. 130 here-in-before but for One 3 pin 5 Amp socket outlet one light point controlled by one switch on independent board.
All as per Srl item No. 130 above, but wiring with cable of cross sectional area 4 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC sheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 4 Sqmm PVC insulated multistranded unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F Modular switch piano 6 Amps single pole, one way, 01 Module complete all as specified and directed by Engineer-in-charge.
S&F Modular Switch socket Combination 5A, 3 pin, 3 modular, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F Modular Switch socket Combination 16A, 6 pin, 3 modular, 230 Volts grade complete all as specified and directed by Engineer-in-charge.
S&F Modular electronic fan regulator suitable for ceiling fan 2 Module, 1200mm / 1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in new sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 2.5 sqmm PVC insulated unsheathed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point controlled by one way switch complete all as specified and directed by Engineer-in- charge.
M&L for point wiring complete with 2.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in new sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 2.5 sqmm PVC insulated unsheathed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point controlled by one way switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 143 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 143 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No. 143 above, but wiring with cable of cross sectional area 4 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 4 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3/5 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEPLUSNEOBS18WLED865SSIND / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, Maxoled batten for T-8 LED retro lamp, polycarbonate body, 1.2m length, ultra bright, glass shell, glare free, wide angle single/ double side connection retrofit LED tube with G-13 lamp holder/patti 20 watt LED light fitting (Day cool light) including 20 watt LED tube with all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LHFXCENNTN1W020 & LHLDDCXCML8Q020 / Crompton cat part No DIJB12LT8-20 & LGT8-16-865-2 or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865S PCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL or equivalent cat part No of makes mentioned in Appendix 'A' here-in-after.
Supply and fixing LED lamp minimum 3 star rated 10W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.90 (e) CRI : Morethan 80
S&F flush mounting factory made SPN DB 8 way, 240 Volt, Single door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made TPN DB 4 way, 415 Volt, Double door, IP-43 protection, IK-09 with metal door with 160 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair MCB 40-63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 32 Amps, Double Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 40 Amps, double pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F MCB 63 Amps, four pole 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F as in repair street light bracket made out of 40mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F rigid non metalic pvc conduit of dia 20mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accesorries such as couplers, lock nuts, saddles pipe hoses etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F in replacement Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 4 Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 4 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
Supply, fixing and testing as in replacement LED Bldg / Security light fitting of 35 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15%, cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
Notes for srl Item No 77 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F ceilling fan copper wound complete with blade, down rod, electronic regulator and accessories AC, 230 V, 50 Hz, 1200mm sweep, min air delievery 210 CFM with serving value 6.00 BEE, with Brush less direct current motor (BLDC) complete all as specified and directed by Engineer-in-charge. Note :- MES No with stencil shall be marked on ceiling fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item.
Fixing only exhaust fan any type and connecting up including provision of cable from ceiling rose/connector to fan with 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge.
M&L for make opening for exhaust fan of in brick walls built in cement mortar and making good disturbed portion as per existing surfaces complete all as specified and directed by Engineer-in-charge.
Fixing only electric water heater, storage type steel body and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) Cost of GI wire upto 7.5m is included in this item. (ii) PCC 1:2:4, Excavation, earthwork is included in the quoted rate of this item. (iii) Cost of GI tubing upto 7.5m is included in the quoted rate of this item. (iv) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (v) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking out old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F as in repair Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account. Note :- A sum of Rs. 88501/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 37 (R) to 39 (R) (Schedule of Credit) of Tender documents.
Gill Construction Co (BID ID -3294551)
SHIVA BUILDERS (BID ID -3294253)
M/S Shree Ram Enterprises (BID ID -3291292)
PAREEK AND COMPANY (BID ID -3291154)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .