Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹48.7 L+₹1.6 L (3.42%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹51.2 L+₹4.1 L (8.66%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹51.9 L+₹4.8 L (10.1%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | Rejected-Technical 23 A MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP 474005 | GWALIOR | GWALIOR | MP | 474005 | - | Rejected-Technical Due to not enlisted in b (ii) category |
| Sl No | Description | Qty | Unit | MONA GENERATOR SEVICES PVT. LTD. L4 | M/S Kumar Contractors L3 | M/s Sagar Construction L1 | BABA DEVELOPERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commisioning of DISTRIBUTION transformer mounted on massonry platform size as recommended by OEM stepdown , 11KV/0.415KV, Three Phase complying with IS:1180(part-1 2014), level-2 with latest ammendments, outdoor type, copper wound suitable for 50 Hz system of capacity 400 KVA , oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in steP of 2.5 %. . The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have BOTH SIDE cable end box with neutral brought out complete all as directed by Engineer - in -Charge.
(a) Lifting lugs for transformer and tank. (b) Earthing terminal rating and diagram plate. (c ) Air release valve with explosion vent. (d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator (g) Silica jel breather (h) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (i) Type of connection Delta/Star (j) Type of cooling: Oil and Natural Air. (k) Vector group:DYN 11. (l) Temperature rise over an ambient of 50 °C maximum. (m) Cable end box on both side for HT/LT cables of suitable size alongwith cable gland. (n) Provision of thermometer with pocket. (o) Provision of oil and winding temperature gauge. (p) Rating & Terminal marking plate. | 1 | Each | 17,74,030 ₹17,74,030 | 14,50,000 ₹14,50,000 Lowest | 16,40,000 ₹16,40,000 | 17,55,000 ₹17,55,000 |
| 2.00 | Supply, install, testing and commisioning of DISTRIBUTION transformer mounted on massonry platform size as recommended by OEM stepdown, 11KV/0.415KV, Three Phase complying with IS:1180(part-1 2014), level-2 with latest ammendments, outdoor type, copper wound suitable for 50 Hz system of capacity 315 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in steP of 2.5 %. . The transformers should be supplied with first filling of oil confirming to IS 335 .The transformer should have BOTH SIDE cable end box with neutral brought out complete all as directed by Engineer - in -Charge.
(a) Lifting lugs for transformer and tank. (b) Earthing terminal rating and diagram plate. (c ) Air release valve with explosion vent. (d) Oil filling inlet pipe with plug.
(e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator (g) Silica jel breather (h) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (i) Type of connection Delta/Star (j) Type of cooling: Oil and Natural Air. (k) Vector group:DYN 11. (l) Temperature rise over an ambient of 50 °C maximum. (m) Cable end box on both side for HT/LT cables of suitable size alongwith cable gland. (n) Provision of thermometer with pocket. (o) Provision of oil and winding temperature gauge. (p) Rating & Terminal marking plate. | 1 | Each | 14,60,774 ₹14,60,774 | 12,50,000 ₹12,50,000 Lowest | 14,50,000 ₹14,50,000 | 15,25,000 ₹15,25,000 |
| 3.00 | Supply, installation, testing and commissioning of 630 A, 11 KV 50 Hz, 3 Phase dead front, Breaking capacity 25 KA, Making capacity 50 KA, floor-standing fully compartmentalized metal clad dust, dump and vermin proof indoor HT switchboard conforming to IEC 62271-200, with provision for bolting to the floor, suitable for severe tropical climate conditions and fully complying with climatic aging tests as per IEC 60932 having separately earthed IP5X rates HV and busbar compartments and IP4X r+F618 LV compartment made of CRCA sheet steel, multi panel shunt trip, indoor type, motor operated spring closing vacuum circuit breaker (VCB) conforming to IEC 62271-100, and complete with all accessories, overload & earth fault protection for rupturing capacity of 350 MVA as specified and directed. The HT switchboard shall confroming the following technical specifictaions :- | 1 | Each | 3,11,351 ₹3,11,351 Lowest | 4,50,000 ₹4,50,000 | 4,25,000 ₹4,25,000 | 5,00,000 ₹5,00,000 |
| 3.01(a) VCB shall be mounted on sithdrawable truck with a rool-n-floor trolley having three interrupters of individual phases mounted on a common phases segregated epoxy body. (b) Self powered microprocessor based IDMT, O/C, E/F numerical relays, conforming to IS 3231:1986, with high set for both phase & earth shall be provided. The relay shall store fault data, site selectable CT secondary relay currents i.e -/5 A or -/1 A LED/LCD display for each function element of a relay to enable identification of the type of fault condtion. Composite relay unit having O/C, E/F, O/V, U/V etc shall be preferred. The numerical relays shall be of communiable type and shall communicate on MODBU protocol. The use of communication protocol converter is unacceptable. Minimum 10 DI/DO shall be provided. (c) Digital type multi function meter displaying A, V, PF, Hz, kVA, kW, kVAr, kWh, kVArh etc of class 0.5 accuracy with RS485 port for communication in Modbus protocol shall be provided. | |||||||
| 3.02(d) Ammeter & voltmeter selector switches shall be of four position type and have make before break feature to prevent open circuiting of CT secondary. Selector switch shall be suitable for semi flush mounting with only switch front plate and operating handle projecting out. (e) Current transfomers shall be double core window/bar primary. Maximum VA burden shall be 15 VA and rated for full short circuit current for 1s. CTs shall be of a minimum accuracy of class 0.5/5P10 and CT Secondary rating shall be A unless otherwise specified, CT Ratio shall be 300/200/5+5A. (f) Potential transformer shall be 3-Phase, 3 Limb type with 50 VA per phase of class 0.5/3P accuracy and shall be mounted on incomer breaker truck. The same shall be mounted in a separate withdrawable truck in a separate vertial panel for bus connected PT. | |||||||
| 3.03(g) Control supply for closing and tripping shall be 110/220 V DC through an external battery source, 230 V, 50 Hz 1 Ph AC supply shall also be availabel for the operation of spring charging motor and cubicle space heater. Wattage rating of closing and tripping coils shall be within 250 W, Auxiliary supply shall be suitably distributed alongwith switchgear in loop in loop out fashion. (h) All the secondary wiring in the panel shall have high quality PVC insulation and the same shall have conductor size of not less than 1.5 Sqmm of copper. (j) Rate inclusive of disconnecting old VCB and connecting new VCB from existing Aluminium bus bar & connecting links to HT/VCB to match with existing system. Notes : (i) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADS of the windings with details of insulation of each point and core construction etc for approval of the accepting officer. (ii) The bidder shall intimate the Accepting Officer for the routine tests in accordance with IEC-62271-200 & IEC 62271-100 in the OEM factory in presence of a representative nominated by the Accepting Officer before despatch. | |||||||
| 4.00Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:- | |||||||
| 4.01 | 400 Sqmm 3.5 core | 30 | RM | 2,333 ₹69,990 | 2,000 ₹60,000 Lowest | 2,100 ₹63,000 | 2,200 ₹66,000 |
| 4.02 | 240 Sqmm 3.5 core | 60 | RM | 1,473 ₹88,380 | 1,400 ₹84,000 | 1,290 ₹77,400 Lowest | 1,450 ₹87,000 |
| 5.00 | M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground, earth pit not less than 2.25m deep below normal GL with top edge of the earth plate not less than 1.25m below GL connected with earth strip 32 x 6 by means of check nuts, bolts, nuts, washers of GI or steel all as shown in plate no. 3 of MES sch. Pt 0I, connected to main switch board all as specified and testing on completion including provision of earth strip protected by galvanized iron 15 mm dia light grade including all excavation, earth work, PCC, RCC cover, watering by funnel etc. complete including testing on completion complete all as specified directed | 10 | Each | 5,908 ₹59,080 | 6,000 ₹60,000 | 5,500 ₹55,000 | 5,000 ₹50,000 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
29 Dec 2025, 6:00 pmClosed
SHRI ANIL KUMAR, IDSE, SE, CWE
HQ CWE JHANSI
PROVN OF NEW TRANSFORMER AGAINST BER AND REPAIR AND RENOVATION OF ELECTRICAL SUPPLY IN MES INSTALLATION UNDER GE GWALIOR AT MORAR CANTT
2025_MES_743283_1
CWE/JHA/GWL/TOKEN/87 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GWALIOR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE GWALIOR
₹1 L
Yes
7 Mar 2026
5 Dec 2025
31 Dec 2025
5 Dec 2025
29 Dec 2025
20 Dec 2025
(g) Control supply for closing and tripping shall be 110/220 V DC through an external battery source, 230 V, 50 Hz 1 Ph AC supply shall also be availabel for the operation of spring charging motor and cubicle space heater. Wattage rating of closing and tripping coils shall be within 250 W, Auxiliary supply shall be suitably distributed alongwith switchgear in loop in loop out fashion. (h) All the secondary wiring in the panel shall have high quality PVC insulation and the same shall have conductor size of not less than 1.5 Sqmm of copper. (j) Rate inclusive of disconnecting old VCB and connecting new VCB from existing Aluminium bus bar & connecting links to HT/VCB to match with existing system. Notes : (i) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADS of the windings with details of insulation of each point and core construction etc for approval of the accepting officer. (ii) The bidder shall intimate the Accepting Officer for the routine tests in accordance with IEC-62271-200 & IEC 62271-100 in the OEM factory in presence of a representative nominated by the Accepting Officer before despatch.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-
400 Sqmm 3.5 core
240 Sqmm 3.5 core
M&L for sand cushioning in trenches for cable protection including consolidation complete all as directed.
Supplying and laying un reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed
M&L Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M & L, for cement concrete, type B-0 1:2:4 (using 12.50 mm graded stone aggregate) complete all as specified and as directed.
M&L for angle iron posts and struts in fencing including cutting tops to shape (swan neck) or as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work including 40x6mm flat iron for holding chain link fencing conforming to Fe-290 Gde E-165 all as specified and as directed.
S&F Framed work as in doors or gates or chowkhat of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete complete all as specified and directed.
Mild steel round bars Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Fixing only galvanised chain link fencing of 4mm dia GI wire including line wire standards rails straining bolts etc including provision of binding wire and mesh size as per direction of GE Gwalior & complete all as specified and as directed.
Supply only galvanised chain link fencing of 4mm dia GI wire including line wire standards rails straining bolts etc including provision of binding wire and mesh size as per direction of GE Gwalior & complete all as specified and as directed.
M&L, for 100mm Cement concrete type D-2, 1:4:8 (40mm graded aggregate) complete all as specified and as directed.
Providing and laying 60mm thick laquer finish (ISI Marked) factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tenderdocuments87.pdf
Tender Documents • 1.35 MB
BOQ_832297.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .