Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹15.9 L+₹1.4 L (9.56%)Rejected-AOC NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹16.0 L+₹1.5 L (10.4%)Rejected-AOC | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | L4₹17.1 L+₹2.6 L (18.2%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L4 | Rejected-AOC Rejected being not L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai 600 055
STRUCTURAL REPAIRS AND REAPAIRS TO ROOF INCLUDING MISC WORK IN THE BLDGS OF AF UNDER AGE BR II AREA AT AF STATION AVADI
2021_MES_415013_1
8812
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Avadi
₹40,000
Yes
9 Mar 2021
21 Jan 2021
22 Feb 2021
21 Jan 2021
19 Feb 2021
4 Feb 2021
60 days
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for(reinforcement cut as reqd to facilitate demolition) complete all as specified and as directed.
Material and Labour for RCC 1:2:4 type B1 using 20mm graded stone aggregate for chajjas and similar works complete all as specified and as directed. Note : Reinforcement and form work shall be measured and paid separately
Material and Labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for coving to chajjas, rounded or chamfered on edges etc and similar works complete all as specified and as directed.
M&L Form work to sides and soffits of concrete chajjas and similar works for fair finished surfaces of complete concrete complete all as specified and as directed.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for mild steel TMT bars 8mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Plastering in CM 1:3, 5mm thick on ceiling surfaces and finishing the same even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in two coats viz first coat 10 mm thick in CM 1:6 and finishing coat 5 mm thick in CM 1:4 mixed with water proofing compound as per manufacturer's instruction on fair faces of stone/brick/concrete surfaces and finished even and fair complete all as specified and as directed. Note : Supply only water proofing compound will be measured and paid separately.
Supply only integral water proofing compound complete all as specified.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement based paint all as specified and as directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exc 15cm thickness ( below or above GL) complete all as specified and as directed.
M & L for 75 mm thick PCC 1:3:6, type C2 using 40mm graded stone aggregate as in plinth protection and finished even and smooth without using extra cement complete all as specified and as directed.
M & L for PCC 1:2:4 type B1, 40mm thick using 20mm graded stone aggregate, finishing cement concrete surface even and smooth using extra cement all as complete all as specified and as directed.
M & L for 38mm wide glass dividing strips, 3mm thick and inserted in a position confirming to design complete all as specified and directed.
M & L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to receive floor finishes complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding,(but not backing) and rubbish off the premises complete all as specified and as directed.
M&L chequerred cement concrete tiles 30cm x30cm x25mm thick set and jointed and pointed in neat in grey cement slurry with pigment in floors over 20mm thick screed bed in CM 1:4 bedded and jointed complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry all as specified.
M & L for machine pressed precast concrete interlocking paver block of any shape and size with grey cement & pigment confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed.
M & L for 50mm thick sand filling under interlocking paver block complete all as specified and as directed.
M & L for Chipping, Cheselling surface mechanically with chipping machine :- (1) Providing zinc rich primer for exposed reinforcement (2) Providing 100x100x3mm weld mesh and fixing the same with sheer connectors of 8 mm dia with epoxy resin. (3) Rendering the area with CM 1:3 with two layers of 15mm thickness each in small areas/patches complete all as specified and as directed.
M & L for crack repair work in walls :- (1) Clean surface around crack, joint should be free from loose particles and dust, cutting 'V' shaped groove along the crack line by machine or manually, then clean the groove by wire brush to remove loose particles and thenwashed by water jet, and fixing nozzle and reparing cracks using Fosroc Rendroc CS chemical complete all as specified and as directed. .
M & L for crack repair work in slab areas:- Chipping the loose particles and corrosion treatment done to existing rod and then bonding agent nitobond SBR applied to the surface, bottom shuttering to be provided before concrete pouring, and apply MICRO CONCRETE using Rendroc RG-SLAB- II levels complete all as specified and as directed. .
Demolition of plain cement concrete (Unreiforced) of any description and in any position not otherwise specifically provided forcomplete all as specified and as directed.
S & F in repairs posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E165 complete all as specifieied and directed.
S & F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E165 complete all as specifieied and directed.
M&L PCC 1:3:6 type C2 using 40mm graded stone aggregate for fixing of MS posts in foundations etc all as specified and as directed.
S&F Galvanised ,2 strand,steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standerd rails staining bolts ,including securing or tying at crossings with and provission of galvanised mild steel wire ,stapples or steel pins ,etc complete all as specified and as directed(each line to be measured)
S&F in repairs Galvanised ,2 strand,steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and including re-straining, re-securing including making good staples etc; straining and fixing to any type of standerd rails staining bolts ,including securing or tying at crossings with and provission of galvanised mild steel wire ,stapples or steel pins ,etc complete all as specified and as directed(each line to be measured)
Dismantling Plain or corrugated steel sheeting any guage, thickness including nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre painted galvalume aluminium Zinc coating GI based corrugated steel 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0 (Brackets over 10kg each to be measured under `Structural Steel') complete all as specified and directed.
M&L for joist channel, angle or tee sections, FI (FE290 Gde E165) fixed independently, without connecting plates etc cut to ordinary lengths ie within 20 mm of the length indicated) complete all as specified and directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10 cm wide or girth including preparation of surfaces etc., complete all as specified and directed.
S&F in repairs 3.8mm dia PVC coated steel wire, chain link of size 50 x 50mm mesh, PVC coated [colour will be decided by GE] made into , laped, wired laid in position all as specified and as directed.
S&F MS screw bolts machine made with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screw end to be fitted with washers length nexc 5 cm and dia 5 to 10mm complete all as specified.
Complete Removal of existing water proofing treatment over roof including PCC of any thickness description in any position including cleaning wire brushing, watering remove of debris up to 1500 mtr distance etc., complete all as specified and as directed.
Material and Labour PCC 1:2:4 type B-0, using 12.50 mm graded stone aggregate as in, levelling course using integral water proofing compound as per manufacturers instructions including demolition of unserviceable unreinforced cement concrete as in roofs complete all as specified and directed. Note:- WPC shall be measured and paid seperately.
Material and Labour for Rendering/ bedding layer of mortar 10mm thick in CM 1:3 on brick or concrete surfaces mixed with integral water proofing compound as per manufactures instruction while the concrete is green all as specified and as directed. Note:- WPC shall be measured and paid seperately.
Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade at the rate of 1.2 kg per sqm applied on the cleaned surfaces complete all as specified and directed.
Material and Labour for APP based polymeric membrane as per IS 16540-2017/ IS 16532-2017 with overlap of 100mm minimum weighing 3.6 kg/ sqm and minimum 3mm thick reinforced with polyester non woven fabric (weight not less than 150gms/ sqm) laid on primed surface by forced application complete all as per manufacturer's instructions as specified and as directed.
Material and Labour for applying one coat of bituminous aluminium paint @100gms/sqm complete all as specified and as per manufaturer's instructions.
Supply and Fix 20mm bore Unplasticised PVC pipes including all fittings (such as unions, elbows, etc.) of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc.,complete and making good the area to match with existing surface, including taking down the existing unserviceable pipes complete all as specified and as directed.
Ditto all as per item No 34 described herein before, but 25 mm bore.
Disconnecting existing tanks exc 250 ltrs and n.exc 500ltrs capacity, setting a side or (lowering if requird ) for repairs etc, and refxing in same position in all respect all as directed
All as per item No 38 but Exc 500 ltrs and n.exc 1000 ltrs
S & F in repairs 25mm bore, ball cock, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) all as specified and as directed.
S & F in repairs 20mm bore, ball cock, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) all as specified and as directed.
SAMYDOSS CONSTRUCTIONS
M/s Omm Muruga Enterprises
S K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .