Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹2.2 Cr+₹14.5 L (6.98%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹2.2 Cr+₹14.5 L (6.98%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹2.4 Cr+₹35.3 L (16.9%)Rejected-Finance | ₹2.4 Cr+₹35.3 L (16.9%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹2.6 Cr+₹54.3 L (26.1%)Rejected-Finance BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹2.6 Cr+₹54.3 L (26.1%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹2.7 Cr+₹61.3 L (29.5%)Rejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹2.7 Cr+₹61.3 L (29.5%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹3.3 L
Closing Date
27 Jan 2022, 6:00 pmClosed
CE (AF) Gandhinagar
HQ CE (AF) Gandhinagar Lekawada Patia Chiloda PO CRPF Campus Gandhinagar-382042
PROVN OF CERTAIN WORKS SERVICES IN AN AROUND WSA AND BDPS AT AIR FORCE STN UTARLAI
2021_MES_480732_2
82354/E8
Open Tender
Civil Works
Lump-sum
GE (AF) Utarlai
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Utarlai
₹3.3 L
Yes
18 Feb 2022
22 Nov 2021
28 Jan 2022
22 Nov 2021
27 Jan 2022
21 Jan 2022
25 Nov 2021 - 29 Nov 2021
Amount
NOTE: Schedule ‘A’ Part I to XI are under Ser No. 2.00 to 12.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part III
Lump sum price worked out for Road/Hardstanding as listed in Sch `A’ Part IV
Lump sum price worked out for External Electrification as listed in Sch 'A’ Part V
Lump sum price worked out for Air Conditioning as listed in Sch 'A’ Part VI
Lump sum price worked out for Fire Alram system as listed in Sch `A’ Part VII
Lump sum price worked out for Stand by Power supply as listed in Sch `A’ Part VIII
Lump sum price worked out for Lightening Protection as listed in Sch 'A’ Part IX
Lump sum price worked out for Demolition and Dismantling as listed in Sch `A’ Part X
Lump sum price worked out for Additional B/R items as listed in Sch `A’ Part XI
SCHEDULE `A' PART-XII MISCELLANEOUS ITEMS OF WORK (Note for items 13 to 27. The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
M & L for sand cushioning all around the cable for protection by natural tibba sand complete all as specified & directed.
Supplying and Laying stone patti 40-50mm thick, 25-30cm wide abutting each other for cable protections complete all as specified and as directed.
S&F horizontal PAN type (Wall mounted/Floor mounted) humidifier made from 1.2mm stainless steel sheet welded construction with steam outlet nozzle, top open able with stainless steel bolt heating element Electrical resistance immersion type stainless steel tube Chromium plated rating with capacity 6 KW heater with Thermostat to maintaining 85 C temperature controls float switch (low level cut out ) with nylon ball and float valve with stainless steel ball thermostat side glass insulation 25mm thick fiber glass wool clamed with 18 gauge thick CRC (Epoxy painted) sheet complete including pron of electric cable with accessories from main panel to Humidifier The electric panel made out of 1.8 mm thick CRCA sheet epoxy coated having the following items. (I) out going contractor of 63Amps-01 (ii) indicting lamp RYB -01 set (iii) Volt meter-01 (iv) Ammeter with CT provision0-30A-1 (v) Humidity controller with digital processor .
Supply installation testing & commissioning of Ionization smoke detector consisting of dual ionization chamber and having radioactive oil of American 241 complete with base plate UL, UPCB approved system , sensor Edwardsense response indicator lamps mounting base on 'J' Box for fixing etc including wiring with 1.0 Sqmm FRLSH wire in steel conduit 20/25 mm dia all as specified and directed.
Supply installation testing & commissioning of photo electronic type smoke detector having of dual ionized chamber meant for easy detection oh high carbonised fume by means of light emitting principle complete with base UL, lpcb approved make and having radioactive oil of of American 241 complete with base plate UL, UPCB approved system , sensor Edward including wiring with 1.0 Sqmm FRLSH wire including steel conduit 25mm dia all as specified and directed.
Supply & fixing test and commissioning of response indicator made from 16 SWG CRCA sheet having Dust red LED indicator & provision for cable / wire entry from top wiring with 1.0 Sqmm FRLSH wire including steel conduit 25mm dia all as specified and directed.
Supply & fixing manual call box(pol box) made from 18 SWG CRCA sheet having single LED indicator and release type push button with incase of FIRE BREAK GLASS printed on front cover with chain and hammer including wiring with 1.0 Sqmm FRLSH wire including steel conduit 25mm dia all as specified
Supply, installation, testing & commissioning of medium intensity electronic hooter (Siren) cum speaker made from 16 SWG CRCA sheet with Philips/Ahuja make speaker & circuit having on output of 80 DB & painted FIRE ALARM on top cover with fire red finish including wiring with 1.0 Sqmm FRLSH wire including steel conduit 25mm dia all as specified and directed
Supply and fixing, testing & commissioning Micro Processor based control panel (Fire Alarm control panel) of 6 Zones with battery charging circuit with power supply unit having provision for audio, video indications for FIRE FAULT, OPEN/SHORT EARTH CIRCUIT for each zone independently for tripping air conditioner unit split type in case of fire and shall have 2 x 12 volt 32 AH batteries set for 8 hour back up incase of main failure and shall have:- a) Visual & audio indicators for fire alarm b) Provision of sound all the sirens in case of actual fire/during testing. (c) Visual indications for clear, healthy and faultness circuit. (d) Facility to indicate failure of indications lamps of the circuit by visual audio alarm system different from actual fire alarm. (e) Facility to indicate audio able signals being switched off by means of indicating lamps.
Supply installed test and commissioning of 6 zones Repeater panel for introphasing the main panel having provisioning of Audio, Vidio, indicacation same as in main panel zones for remote indication including wiring with 1.0 Sqmm FRLSH wire including steel conduit 25mm dia all as specified and directed.
Supply, installation, Testing and commissioning of silent diesel engine driven generating set water cooled 415 Volt 3 Phase wire engine as per IS 10001/10002 and alternator as per IS 13364 complete with relay panel for automatic starting of main failure control panel having meter sound proof canopy and foundation as per coy recommendation etc of capacity 100 KVA , all as directed. The design of integrated acoustic enclosure should be of type approved by National Physical Laboratory as per Central Pollution Control Board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories and fitting PCC foundation for (acoustic enclosure also 30 cm above ground level) as recommended by manufacturer. Vibration pad, sand cushioning around PCC foundation, tools and spares as provided by manufacturer all as specified and as directed with the following specification :- (A) ENGINE - Water cooled diesel engine of suitable capacity to match the 100 KVA alternator under NTP conditions with provision of 10% over load for 1 hour in every 12 hours running conforming to IS-10002 ISO 3046 BS 5514. The engine shall consist of the following :- (i) Fly Wheel (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry
(vii) fuel injecting pump(viii) Mechanical governor(ix) Fuel filter (Mounted) (x) Radiator fan (Blower type) with guard(xi) Lubricating of filters (Mounted)(xi) 12 Volt self regulating alternator belt driven by engine.(xii) Exhaust silencer heavy duty residential type. (xiv) Corrosion resistor/scale inhibitor (xv) Starter 12 VDC.(xvi) Lubricating Oil Cooler(xvii) Lubricating oil pump (Gear type) (xviii) Turbo charger (xviiii) Exhaust piping shall not be more than3.0 m with asbestos rope logging covered with aluminum foil caning.(xvii) Instrument panel electronic type with fault memory complete to be installed inside the sound proof enclosure with :- (a) Auto/manual starting switch with key. (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge.(d) Water temperature gauge (e) Battery charging ammeter.(f) Battery charging indicating lamp. (g) Hour meter with RPM indicator. (h) Safety control against low lubricating oil pressure. (j) Safety control against high temperature of water. (k) Over speed stop with double driven adopter. (l) Coolant solution. (m) Control against high temperature of water.
(B) BRUSH LESS ALTERNATOR :- (i) Alternator coupled to engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brush less alternator shall be conforming to BS-2613 or relevant IS-4722. (ii) Type :- Self-excited self regulated with automatic voltage regulator.(iii) Rating :- 100 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition.(iv) Speed - 1500 RPM(v) System :- 415 Volts + 2.5% AC - 3 phase 4 wire 50 HZ.(vi) Condition :- 4 wire star connected.(vii) Enclosure :- Screen protected drip proof(viii) Ventilation :- Self-ventilated.
(D) ONE SET OF ACESSORIES : COMPRISING OF :- (a) FUEL TANK : One No made of sheet steel 14 SWG and capacity to hold diesel sufficient for running 08 hours running at full load including :-(i) Level indicator of fuel tank(ii) Drain plug(iii) MS Class 'C' piping for inlet from pump to tank of engine (iv) Fuel strainer.(v) Fuel tank shall be mounted as per manufacturer's instructions.(b) SEMI ROTARY PUMP :- Manually operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 m flexible hose pipe of suitable size heavy duty for suction of diesel from barrel.(c) BATTERY :-Heavy duty batted one No 12 V 180 AH connected to the system with multithreaded flexible copper lead 1.5 mtr long welded with battery terminals fully charged ready for lead complete all as specified. Make : Exide, Amaron(d) BASE PLATE :- Fabricated out of MS channel's and ISMC of suitable size suitable for fixing of DG set all as specified by the manufacturer.(E) TOOLS KIT :-(i) Box type spanner set consisting of 12 spanner - 01 Set.(ii) -do- but D/E ( 05 mm to 27 mm ) - 01 set.(iii) 1 year maint spare kit as per maint manual of manufacturer. Note :- PCC foundation/platform shall be included in the above quoted rates.
Supply, installation, Testing and commissioning of silent diesel engine driven generating set water cooled 415 Volt 3 Phase wire engine as per IS 10001/10002 and alternator as per IS 13 364 complete with relay panel for automatic starting of main failure control panel having meter sound proof canopy and foundation as per coy recommendation etc of capacity 62.5 KVA , all as directed. The design of integrated acoustic enclosure should be of type approved by National Physical Laboratory as per Central Pollution Control Board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories and fitting PCC foundation for (acoustic enclosure also 30 cm above ground level) as recommended by manufacturer. Vibration pad, sand cushioning around PCC foundation, tools and spares as provided by manufacturer all as specified and as directed with the following specification :- (A) ENGINE - Water cooled diesel engine of suitable capacity to match the 62.5 KVA alternator under NTP conditions with provision of 10% over load for 1 hour in every 12 hours running conforming to IS-10002 ISO 3046 BS 5514. The engine shall consist of the following :- (i) Fly Wheel (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry
(vii) fuel injecting pump(viii) Mechanical governor(ix) Fuel filter (Mounted) (x) Radiator fan (Blower type) with guard(xi) Lubricating of filters (Mounted)(xi) 12 Volt self regulating alternator belt driven by engine.(xii) Exhaust silencer heavy duty residential type.(xiv) Corrosion resistor/scale inhibitor (xv) Starter 12 VDC.(xvi) Lubricating Oil Cooler(xvii) Lubricating oil pump (Gear type)(xviii) Turbo charger (xviiii) Exhaust piping shall not be more than 3.0 m with asbestos rope logging covered with aluminum foil caning.(xvii) Instrument panel electronic type with fault memory complete to be installed inside the sound proof enclosure with :- (a) Auto/manual starting switch with key. (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge.(d) Water temperature gauge (e) Battery charging ammeter.(f) Battery charging indicating lamp. (g) Hour meter with RPM indicator. (h) Safety control against low lubricating oil pressure. (j) Safety control against high temperature of water. (k) Over speed stop with double driven adopter. (l) Coolant solution. (m) Control against high temperature of water.
(D) ONE SET OF ACESSORIES : COMPRISING OF :- (a) FUEL TANK : One No made of sheet steel 14 SWG and capacity to hold diesel sufficient for running 08 hours running at full load including :-(i) Level indicator of fuel tank(ii) Drain plug(iii) MS Class 'C' piping for inlet from pump to tank of engine. (iv) Fuel strainer.(v) Fuel tank shall be mounted as per manufacturer's instructions. (b) SEMI ROTARY PUMP :- Manually operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 m flexible hose pipe of suitable size heavy duty for suction of diesel from barrel. (c) BATTERY :-Heavy duty battery one No 12 V 160 AH connected to the system with multithreaded flexible copper lead 1.5 mtr long welded with battery terminals fully charged ready for lead complete all as specified. BASE PLATE :- Fabricated out of MS channel's and ISMC of suitable size suitable for fixing of DG set all as specified by the manufacturer.(E) TOOLS KIT :-(i) Box type spanner set consisting of 12 spanner - 01 Set.(ii) -do- but D/E ( 05 mm to 27 mm ) - 01 set.(iii) 1 year maint spare kit as per maint manual of manufacturer. Note :- PCC foundation/platform shall be included in above quoted rates.
M&L two coat of Fire resisting paint including primer over new steel surface including preparation of new steel surface complete all as specified.
Supply and fix flameproof and weather proof industrial type DB with various combination of incoming and outgoing MCB suitable for and including:- (a) 01 No MCB SPN 16 Amps 'C' series (b) 06 Nos of MCB SP 10 Amps 'C' series including necessary connection complete.
M/s godara infratech and power industries
Dasmesh Buildcon
Brahma Infra
RAGHUSONS INFRA ENGINEERING PVT. LTD
SG ENGINEERING CO
M/s Tansingh Chouhan
Shri Ram Traders
Anil Builders
MADAN MOHAN JAIN sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .