Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.0 L+₹8.3 L (39.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹29.0 L+₹8.3 L (39.9%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹32.6 L+₹11.9 L (57.2%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹43.2 L+₹22.5 L (108.3%)Rejected-Finance 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹95,500
Closing Date
4 Mar 2021, 6:00 pmClosed
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
REPAIR/REPLACEMENT OF HOT WATER BOILER (HAMMAM) AND STAND ALONE CHS AND HEATING PANELS AT SECTOR A AND B AREA UNDER AGE EM-II OF GE 865 EWS
2021_MES_419107_1
138WE/L-67/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹95,500
Yes
3 Apr 2021
4 Feb 2021
6 Mar 2021
4 Feb 2021
4 Mar 2021
19 Feb 2021
Amount
Attending the complaints of Hot water plants/Stand alone CHS plants for checking the burner assembly, fuel pumps, injectors, starter etc. and checking continous electric supply including checking and rectification of electrical fault of Hot water Boilers/Stand alone CHS plants installed at various unit locations at Leh area under AGE E/M-II sub division, making the plants functional incl minor repairs where ever required as per site requirement, complete all as specified and directed by Engr-in-Charge. Note : The spare parts for replacement shall be measured and paid seperately under respective items of schedule.
M&L for replacement of Photocell suitable for 0.35 to 1.5 Lakh Kilo/Cal/Hr burner, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Ignition Transformer electronic type suitable for 0.35 to 1.5 Lakh Kilo/Cal/Hr burner rod assembly, complete all as specified and directed by Engr-in-Charge.
M&L for Sequence controller suitable for 0.35 to 1.5 Lakh Kilo/Cal/Hr burner rod assembly complete with all electric connections, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Thermostat assembly tail type as per existing, suitable for 50-300 degree centigrade temperature, complete all as specified and as directed by Engr-in-Charge.
S&F Temperature controller digital type DTC-503 with sensor suitable for 0.35 to 1.5 Lakh Kilo/Cal/Hr burner rod assembly, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Burner Nozzle suitable for Burner capacity 0.35 to 1.5 Lakh Kilo/Cal/Hr all as per existing, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Electrode suitable for Burner capacity 0.5/1.0 / 1.5 Lakh Kilo/Cal/Hr all as per existing, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Oil Pressure Pump suitable for Burner capacity 0.5/1.0 / 1.5 Lakh Kilo/Cal/Hr AS47A all as per existing, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Thermal Over Load Relay, 3 pole, 10 - 18 Amp all as per existing, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Diesel Filter all as per existing, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Push Button type ON/OFF switches all as per existing, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of High pressure fuel pipe 1.50 mtr long all as per existing, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Rotary type switch all as per existing, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Indicating Lamps RYB all as per existing, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Digital type Volt Meter complete with touch control switch 0-500 volts, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Digital type Amp Meter complete with touch control switch and suitable for CTs 0-300 Amps, complete all as specified and as directed by Engr-in-Charge.
S&F 50mm dia, Gun metal globe or Gate valve, with iron wheel head, screwed both ends for iron/GI pipe, complete all as specified and as directed by Engr-in-Charge.
S&F 40mm dia, Gun metal globe or Gate valve, with iron wheel head, screwed both ends for iron/GI pipe, complete all as specified and as directed by Engr-in-Charge.
S&F 25mm dia, Gun metal globe or Gate valve, with iron wheel head, screwed both ends for iron/GI pipe, complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of MK-I Starter Star Delta, 3 phase, 415 volts as per existing, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire, 3 core of 6 Sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire, 2 core of 6 Sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
M&L for Rewinding of electric motor, 3 phase, 415 volts of capacity 5 HP with superior quality super enameled copper winding wire of appropriate size and gauge as per existing, including varnishing, cotton tape, PVC sleeves etc., complete all as specified and directed by Engr-in-Charge.
M&L for dismantling of burner assembly and removing of side cover of boiler capacity 0.75 to 1.5 Kilo/Cal/Hr and complete serviceing the boiler by using coil shine chemical and removing the complete carbon/oil deposites including repair to coil assembly if there is any leakage found or any other repair required at site and reassembling/testing the same, complete all as specified and directed by Engr-in-Charge.
M&L for dismantling of burner assembly of Stand Alone CHS and removing of side cover of boiler capacity 0.5/0.35 Kilo/Cal/Hr and complete serviceing the boiler by using coil shine chemical and removing the complete carbon/oil deposites including repair to coil assembly if there is any leakage found or any other repair required at site and reassembling/testing the same, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of burner assembly including fixing the assembly in the existing Hot Water Boiler including making necessary arrangments with all required fixing materials and made functional the Hot Water Boiler of capacity 1.0/1.5 Kilo/Cal/Hr and testing the same after completion, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of burner assembly including fixing the assembly in the existing Hot Water Boiler/Stand Alone CHS including making necessary arrangments with all required fixing materials and made functional the Hot Water Boiler/Stand Alone CHS of capacity 0.5/0.35 Kilo/Cal/Hr and testing the same after completion, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing 40 mm dia 3 layer polyproplyene random copolymer (PPR) pipes, SDR 7.4 & SDR 11, UV stablised and antimicrobial fusion welded having thermal stability for Hot and Cold water supply, all PPR plain & brass threaded polypropylene random fittings laid in trenches, complete all as per manufactures instructions and as directed by Engineer-in-charge.
All as per description of Ser Item No 29.00 above but of size 50mm dia pipes, complete all as specified and directed by Engineer-in-charge.
All as per description of Ser Item No 29.00 above but of size 25mm dia pipes, complete all as specified and directed by Engineer-in-charge.
All as per description of Ser Item No 29.00 above but of size 20mm dia pipes, complete all as specified and directed by Engineer-in-charge.
M&L for lagging for 25mm bore pipes to be used in water supply all round with 40mm thick bonded mineral wool preformed, 'SNAP ON' pipe sections of density 144 Kgs/Cum confirming to IS-9842 and providing chicken mess wire netting, 25 guage, 20mm mesh and covered with aluminium foil 0.01mm, complete all as specified and directed by Engineer-in-charge.
All as per description of Ser Item No 33.00 above but of size 40mm dia pipes, complete all as specified and directed by Engineer-in-charge.
All as per description of Ser Item No 33.00 above but of size 50mm dia pipes, complete all as specified and directed by Engineer-in-charge.
All as per description of Ser Item No 33.00 above but of size 20mm dia pipes, complete all as specified and directed by Engineer-in-charge.
Supply and laying XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm, 2 core, laid in trenches or passing through pipes, ducts or fixed to walls/poles, complete all as specified and directed by Engineer-in-charge. Note : Earth work, cable protection and sand cushioning shall be measured and paid seperately.
Supply and laying in replacement XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 35 Sqmm, 3.5 core, laid in trenches or passing through pipes, ducts or fixed to walls/poles, complete all as specified and directed by Engineer-in-charge. Note : Earth work, cable protection and sand cushioning shall be measured and paid seperately.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, in hard/dense soil, complete all as specified and directed by Engr-in-Charge.
Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance n exc 50m and depositing at a level n exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified in clause 19.75 of SSR Part - I and directed by Engr-in-Charge. Note: Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class LV Type-I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed by Engr-in-Charge.
Supplying and fixing of PVC heavy duty vertical type fuel storage tank of 50 Ltrs capacity with necessary connection at bottom for fuel pipe of suitable size complete all as specified and directed by Engr-in-Charge.
M&L for under deck insulation with PUF slab including application of cold bitumen on PUF slab, steel wire of size 46 guage fixed for fastening of 60mm PUF slab, suitable for steel sheet duct of any size, complete all as specified and as directed by Engr-in-Charge.
ASHOK KUMAR SHARMA
M/s Aman Enterprises
S S BUILDERS
VIMAL TRADERS AND SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .