| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-Finance A 178 OLD NO 525 KH NO 2 18 G F BLOCK A PREHLAD VIHAR GUPTA COLONY VILL PRAHLAD PUR DELHI 110042 | NORTH WEST | DELHI | 110042 | ₹9.6 L | L1 | Accepted-Finance L1 |
| 2 | L2₹13.9 LAccepted-Finance GSTIN: 07AMZPK8050HIZHA 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹13.9 L | L2 | Accepted-Finance L2 |
| Sl No | Description | Qty | Unit | PARASAR ELECTRICALS & REFRIGERATION L2 | R S ELECTRICAL WORKS / PHULMATI L1 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C | 30 | Point | 1,200 ₹36,000 | 1,311 ₹39,330 |
| 2.00 | LED Batten light (System lumen efficacy ≥105 <120
lm/Watt).
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/ Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
18-22 Watt | 30 | Each | 600 ₹18,000 | 299 ₹8,970 |
| 3.00 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
200 watt | 4 | Each | 5,600 ₹22,400 | 4,330 ₹17,320 |
| 4.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering.
Upto 35 sq. mm | 60 | Mtr | 300 ₹18,000 | 182 ₹10,920 |
| 5.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wallsurface as required.
Upto 35 sq. mm | 240 | Mtr | 150 ₹36,000 | 47 ₹11,280 |
| 6.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm | 50 | Mtr | 150 ₹7,500 | 29 ₹1,450 |
| 7.10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 kV grade as required.
4 x 25 sq.mm (28mm) | 2 | Set | 200 ₹400 | 189 ₹378 |
| 7.20 | 4 x 35 sq.mm (32mm) | 2 | Set | 300 ₹600 | 188 ₹376 |
| 8.10 | Supplying of Following Items for Routine Operation and Maintenance of Electrical Panels situated at Pump House of FFC complex.
3 pole MCCB, 100A, 16kA Ics= 100% Icu and operational voltage 690 V | 6 | Each | 4,000 ₹24,000 | 1,999 ₹11,994 |
| 8.20 | 4 pole MCCB, 250A, 36kA Ics= 100% Icu and operational voltage 690 V | 2 | Each | 12,000 ₹24,000 | 7,990 ₹15,980 |
Tender Value
₹13.5 L
EMD Value
₹26,970
Closing Date
16 Apr 2026, 3:00 pmClosed
Er. Sunil Kumar
Office of EE (ED-I), TC Building, Wazirpur Indl. Area, Delhi-110052
Routine Operation and Maintenance of all blocks situated at DSIIDC Flatted Factory Complex (FFC) Jhandewalan, New Delhi - 110055
2026_DSIDC_289762_1
Eniq-01/2026-27
Open Tender
Electrical Works
365 days
Jhandewalan
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹26,970
24 Apr 2026
9 Apr 2026
16 Apr 2026
9 Apr 2026
16 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | |||||
| 2LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/ Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 Watt | |||||
| 3LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 200 watt | |||||
| 4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required,but excluding sand cushioning and protective covering. Upto 35 sq. mm | |||||
| 5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wallsurface as required. Upto 35 sq. mm | |||||
| 6Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. Upto 35 sq. mm | |||||
| 7.1 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 kV grade as required.
4 x 25 sq.mm (28mm) | - | Set | - | - |
| 7.2 | 4 x 35 sq.mm (32mm) | - | Set | - | - |
| 8.1 | Supplying of Following Items for Routine Operation and Maintenance of Electrical Panels situated at Pump House of FFC complex.
3 pole MCCB, 100A, 16kA Ics= 100% Icu and operational voltage 690 V | - | Each | - | - |
| 8.2 | 4 pole MCCB, 250A, 36kA Ics= 100% Icu and operational voltage 690 V | - | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
niqdocument1.pdf
Tender Documents • 0.70 MB
BOQ_384772.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid