| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹5.3 L+₹36,497.70 (7.35%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹5.4 L+₹43,496.55 (8.76%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹5.4 L+₹48,269.91 (9.72%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹6.6 L+₹1.7 L (33.7%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
9 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Gurgaon
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-110010
REPAIR/MAINT OF HT GEARS, HT DISTRIBUTION AND ALLIED WORKS AT AFS FARIDABAD UNDER GE (AF) FARIDABAD
2021_MES_472745_1
CA NO CWE/GGN/FT-14/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Faridabad
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Faridabad
₹24,000
Yes
3 Dec 2021
3 Sept 2021
11 Oct 2021
3 Sept 2021
9 Oct 2021
25 Sept 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in deep and getting out in hard/dense soil for laying underground cable, foundation etc all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as directed
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed
Material and labour for sand cushioning to cable using fine sand (Jamuna dry and clean sand ) in two layers , first layer of 80mm thick before laying of cable and second layer of 150mm thick (Punned down to 100 mm thick) after laying of cable complete all as specified and directed by Engineer-in-Charge. Note :- 180 mm thickness only will be considered for the purpose of payment.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 of size 300mm x 180mm x 40mm complete all as specified and directed.
Supplying, laying, testing and commissioning in repairs HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed) grade, cross sectional area 95 Sqmm, 3 core with thimbles and all accessories etc complete all as specified and directed by Engineer-in-Charge
Supplying, laying, testing and commissioning in repairs HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed) grade, cross sectional area 70 Sqmm, 3 core with thimbles and all accessories etc complete all as specified and directed by Engineer-in-Charge
S&F cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, 3core complete all as specified and directed by Engineer-in-Charge
S&F cable jointing kit for 11 KV (E) grade cable for indoor termination cold shrinkable type joint complete with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge
S&F cable jointing kit for 11 KV (E) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, 3core complete all as specified and directed by Engineer-in-Charge
S&F cable jointing kit for 11 KV (E) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm, 3 core complete all as specified and directed by Engineer-in-Charge
M&L cable jointing kit for 11 KV (E) grade cable for straight through cold shrinkable type joint complete with jointing material and accessories, suitable for HT XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, 3core complete all as specified and directed by Engineer-in-Charge
M&L cable jointing kit for 11 KV (E) grade cable for straight through cold shrinkable type joint complete with jointing material and accessories, suitable for HT XLPE armoured aluminium conductor cable of size 120 Sqmm, 3core complete all as specified and directed by Engineer-in-Charge
S&F in repairs Pin/ Post type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for 11000 volts grade including galvanised mild steel straps, washers, insulator bolts, washers and nuts etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single disc assembly for tension with tension clamps for conductor for working pressure 11000 volts complete all as specified and directed by Engineer-in-Charge.
Supplying, installing, testing & commissioning in repairs air break switch, mechanically gang operated 11KV, current rating upto 200 Amps (swing out expulsion fuse isolators), 3 insulators per phase, triple pole rocking, outdoor type, suitable for both horizontal and vertical mounting, DO fuse including channel bases for mounting post insulators, multi-built type contacts to grip incoming and outgoing ACSR conductors, operating mechanism complete with 5/6 m long GI pipe, medium grade 25mm dia, phase coupling shaft, operating handle with and including padlock arrangements conforming to IS 9921/ 1985 (Part I to IV) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs lightning arrester explusion type compete with all fittings, transmission class, discharge capacity up to 65 Kilo Amp, HT 11 KV, 65 KA station class and shall comply with the requirements of routine tests as specified in the relevant IEC: 99-4 & IS:3070 (Part-III) complete all as specified and directed by Engineer-in-Charge
Supply, laying and fixing in repairs galvanised iron pipe, 100 mm bore, light grade, fixed to poles with mild steel clamps of required size or laid through wall or under floor/ road or in trenches etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
S&F in repairs Galvanised iron strip of 32mmx 6mm size as earth continuity conductor or main earthing lead, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engineer-in-Charge.
Dehydration of transformer oil from plinth / pole mounted Transformers etc by dehydration filter machine at site to maintain 40 KV dielectric strength in 2.5mm gap complete all as specified and directed by Engineer-in-Charge.
Supply and topping up of transformer oil in sealed barrel conforming to IS: 335-1983 with latest version at various places including testing etc complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized mild steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to galvanized iron strip of size 32mm x 6mm as earthing lead by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC (concrete chamber) shall be of size 300mm x 300mmx 300mm (internal dimensions) using PCC 1:2:4, type B-1, using 20mm graded stone aggregate coping shall be of PCC 1:3:6, type C-1, using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge (0.68mm) 8 mesh per linear inch, 80mm thick RCC cover of size 320mm x 320mm, made out with RCC 1:2:4, type B-1, using 20mm graded stone aggregate, reinforced with four Nos 8 mm dia TMT bars @80mm centre to centre, both ways and charcoal dust and common salt all as shown in Electrical plate No 3 of SSR Part-I (2009) and specified including 40mm dia GI medium grade pipe as protection pipe and watering pipe shall be 20mm bore GI medium grade including necessary excavation and earth work & connecting the earthing to an earthing test point as specified and testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with copper earth plate electrode of size 60cmx60cmx3 mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected to copper strip of size 25mm x 3mm as earthing lead by means of nuts, bolts, thimbles, check nuts, washers of copper , PCC (concrete chamber) shall be of size 300mm x 300mmx 300mm (internal dimensions) using PCC 1:2:4, type B-1, using 20mm graded stone aggregate coping shall be of PCC 1:3:6, type C-1, using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of 22 gauge (0.68mm) 8 mesh per linear inch, 80mm thick RCC cover of size 320mm x 320mm, made out with RCC 1:2:4, type B-1, using 20mm graded stone aggregate, reinforced with four Nos 8 mm dia TMT bars @80mm centre to centre, both ways and charcoal dust and common salt all as shown in Electrical plate No 3 of SSR Part-I (2009) and specified including 40mm dia GI medium grade pipe as protection pipe and watering pipe shall be 20mm bore GI medium grade including necessary excavation and earth work & connecting the earthing to an earthing test point as specified and testing on completion complete all as specified and directed by Engineer-in-Charge.
Disconnecting worn out HT connections any size from VCB, cutting worn out leads (near lugs), re-fixing new aluminium lugs , cleaning the bus bar chamber with 2-26 CRC solution, insulation with HT tape, connecting the cables with bus bar and testing for smooth functioning complete all as specified and as directed
Repair/servicing of 400/630A 11 KV mechanism/calibration of HT VCB with highly skilled mechanic specialist in electric HT breakers line, by taking out trolley, decarburizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy mvoing of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of IDMT relays contact traqvel contact alignments, roller gap, hard or light seeting of breaker greasing of all moving mechanism complete all as specified and as directed.
Repair/servicing of 400/630A 11 KV mechanism/calibration of HT RMU with highly skilled mechanic specialist in electric HT breakers line, by taking out trolley, decarburizing of all parts using CRC-2-26 spray, checking of all fixed and moving parts, tightening of all nuts & bolts, dressing, cleaning of contacts by using emery paper for fine/smooth contact, tightening of all connections, checking of alignment for easy mvoing of breaker, checking of ON/OFF operation with setting of buffer gap adjustment, inspecting the wiring of IDMT relays contact traqvel contact alignments, roller gap, hard or light seeting of breaker greasing of all moving mechanism complete all as specified and as directed.
Repair/servicing of Automatic power factor correction (APFC) Panel for 3 phase 415Volts 50 Hz system for suitable capacity of KVAR (5x10x20x25 KVAR), capacitor, contactor and digital meter complete all as specified and directed.
M&L for defect rectification in HT 11000/LT 1100 volts cable of size 120 Sqmm to 50 Sqmm by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault locator with high frequency and distance calculation etc. Excavation and earth work are included in the quoted rate complete all as specified and directed.
Material and labour for synthetic/rubber insulating mats of size 2mm thick of size 2mx1m length for electrical purpose to fixed on the floor as per IS-15652:2006 complete all as specified and directed.
M&L for stone aggregate of size not exceeding 40 mm deposited spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer yard and pole structure area.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate including filling of river sand/ stone dust upto 15 cm complete all as specified and directed at site. Note:- (i) Stone dust/river sand shall be measured and paid separately under relevant items of this schedule. (ii) The rate also deemed to be included for labour (iii) All the sub station yards shall be kept clean through out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass.
Net Contract Sum will be after deducting Sch of Credit of Rs 22,250.00
BRIJ MOHAN LAL AND CO.
Shiv Enterprises
Ish Engineers and Contractors
M/S Anand Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .