Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.0 L+₹48,057 (2.91%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹17.9 L+₹1.4 L (8.59%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
21 Jan 2021, 6:00 pmClosed
GE AF THANE
The Garrison Engineer (AF) Thane Kolshet Road, Sandoz Baugh Post,Thane 400607
PROVISION OF TILING IN CERTAIN TMQs AT SITE R, UPGRADATION OF VIP-1 GUEST ROOM IN OFFICER MESS AND CERTAIN BR AND EM SANTIONED MAJOR REVENUE AND MINOR WORKS AT SITE R UNDER GE AF THANE
2020_MES_327386_4
8916/E8
Open Tender
Civil Works - Others
Item Rate
180 days
THANE
AS PER REVISED NIT UPLOADED ALONGWITH TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF THANE
₹38,000
Yes
6 Mar 2021
1 Jan 2021
23 Jan 2021
1 Jan 2021
21 Jan 2021
9 Jan 2021
1 Jan 2021 - 9 Jan 2021
Amount
M&L for dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed by Engr-in-charge.
Demolition of PCC of any description in ground floors n.exc 15cm thick etc, complete all as specified and directed by Engr-in-charge.
M&L for 25mm thick PCC (1:2:4) type B-O using 12.5mm graded stone aggregate stone as in floor finished even and fair to receive the floor finish , complete all as specified and directed by Engr-in-charge.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6) etc , complete all as specified and directed by Engr-in-charge.For the following:-
In floors
In skirting
M&L for coloured Glazed ceramic tiles in vertical surface 450X300X7mm thick, including 10 mm thick CM 1:3 as backing coat ,set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and directed by Engr-in-charge.
Taking down cement plaster on brick or stone walls etc including racking out joints hacking for key, scrubbing down with water etc , complete all as specified and directed by Engr-in-charge.
M&L for rendering 15mm thick in cm 1:6 on fair faces of brick work or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all as specified , complete all as specified and directed by Engr-in-charge.
M&L for Preparing new plastered surfaces, priming plastered and other surfaces with alkali resistant priming paint, and applying two coat of OBD complete all as specified , complete all as specified and directed by Engr-in-charge.
Taking down shutters of any description exc 1 Sqm but not exc 2 sqm for resecuring or easing and refixing in same opening , complete all as specified and directed by Engr-in-charge.
M&L for black granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms , including 10 mm thick cement mortar(1:3) as backing coat, and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite , complete all as specified and directed by Engr-in-charge.
M&L for machine cut cudappa stone slab 15-20mm thick over cement screed base as in jambs and soffits of lintel laid ,including 10mm thick CM 1:3 as backing coat and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing , complete all as specified and directed by Engr-in-charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting in soft /loose soil, complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/dense soil for laying of under ground cable, foundation of poles, stays etc., all as specified and as directed.
M&L Hardcore of Broken stone or boulders gauge exc 63 mm but n exc. 100 mm , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface , complete all as specified and directed by Engr-in-charge.
M&L for 50mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth protection and manhole etc finished even and fair surfaces , complete all as specified and directed by Engr-in-charge.
Returining/filling in including spreading/ levelling, watering and well ramming in layors not exceeding 25cm in any type of soil , complete all as specified and directed by Engr-in-charge.
Removal of surplus spoils soil to a distance not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point , complete all as specified and directed by Engr-in-charge.
M&L form work to side and soffit of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelvves incl support, overhangs etc , complete all as specified and directed by Engr-in-charge.
M&L RCC M-30 Design mix as in roof beams, cantilevers, bressummers, lintels over 1.5m span etc ,complete all as specified and directed by Engr-in-Charge.
M&L TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed ) not less than 0.9mm dia securing with clips ,complete all as specified and directed by Engr-in-Charge.
M&L TMT bar 5mm dia and over upto and including 10mm dia in stirrups, cut to length band to shape required incl cranking bending, spirally for hooping for columns hooking ends and binding with MS wire 0.9mm dia or securing with clips for spacer and binder and in stirrips complete all as specified and directed by Engr-in-Charge.
M&Lfor rendering 15mm thick in CM 1:4 on fair faces of brick work incl WPC @ 3% by weight of cement ,complete all as specified and directed by Engr-in-Charge. (Note:WPC shall be paid saperately)
Supply only integral water proofing compound ,complete all as specified and directed by Engr-in-Charge.
M&L for IInd class hard wood plain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints ,complete all as specified and directed by Engr-in-Charge.
M&L for 35mm thick IInd class HW rail and style plain framed panelled factory made shutter (Two panel) with lock rail and panel of 9mm BWP,commercial ply or 12mm veneered particle beard with commercial veneering on both faces. The size of rail and stile as per IS :1003 (Part-I) kiln and chemically pressure treated ,complete all as specified and directed by Engr-in-Charge.
M&L for 35mm thick Iind class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or reounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chawkats ,complete all as specified and directed by Engr-in-Charge.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples ,complete all as specified and directed by Engr-in-Charge.
M&L for powder coated aluminium Door/ window/ sliding window / Ventilator / partition frames and shutters using standard aluminium powder coated sections including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, anodised aluminium fittings suitable Nylon gasket, nylon rollers, maruthi locks, handles, concealed star lock, aluminium F channel for fixing aluminium grill and all necessary fittings and fixtures etc all as specified etc complete of standard sections and fixing to cudappa stone/granite stone with necessary bolts/screws ,complete all as specified and directed by Engr-in-Charge.
M&L for Powder coated aluminium anodized grill of 4.75 x 7.75 mm, size of opening 10cm, size of mesh RG 103 (as per royal grill) with aluminium channel `F' angle 20mmx15mm fixed to aluminium frame work ,complete all as specified and directed by Engr-in-Charge.
S & F MS Butt hinges of cold rolled mild steel,medium weight,100mm size ,complete all as specified and directed by Engr-in-Charge.
S&F aluminium alloy, anodised sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed ,complete all as specified and directed by Engr-in-Charge.
S&F aluminium anodised barrel tower bolt 200mm long of extruded section and fixed ,complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of wall & apply two coats of acrylic paint over a coat of weather coat primer ,complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new wood surfaces of any description over 10cm width of girth applying two coats of synthetic enamel paint over coat of pink primer etc ,complete all as specified and directed by Engr-in-Charge.
Demolition of bickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar ,complete all as specified and directed by Engr-in-Charge.
M & L for Brick work with sub class 'B' bricks with old size bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified ,complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) ,complete all as specified and directed by Engr-in-Charge.For the following sizes:-
Not exc 1.5 sqm
Exc 1.5 sqm but not exc 4 sqm each
S&F 30mm thick Flush shutters,solid core construction,with block board core and plywood covered with decorative face venner with lipping/frame on both sides approved by Engr -in-Charge etc complete all as specified and as direted .
S&F 300mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts decoorative type as approved by Engr -in- Charge complete all as specified
S&F 200mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts decoorative type as approved by Engr -in- Charge complete all as specified.
S&F 150mm Brass handles, cast type polished bright etc complete all as specified and decoorative type as approved by Engr -in- Charge.
M&L for 4.80 mm thick ordinary quality and glazing in square n. exc 0.5 sqm in each pan ,complete all as specified and directed by Engr-in-Charge.
M&L for rounding to edges of stone slabs one edge , such as in steps, cooking platform, and other similar situations ,complete all as specified and directed by Engr-in-Charge.
M&L for Vitrified Ceramic tiles Double charged 10mm thick (Square / rectangular) polished, area of each tiles not exceeding 0.42 Sqm etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 ,complete all as specified and directed by Engr-in-Charge.For the following :-
In floors
In Skirting
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing ,complete all as specified and directed by Engr-in-Charge.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 ,complete all as specified and directed by Engr-in-Charge.
S&F Welded steel wire fabric complete to wood or steel members n Exc 4 Kg/Sqm ,complete all as specified and directed by Engr-in-Charge.
M&L for providing Plain cement concrete (1:2:4) type B-1 using 20mm graded stone agg as in coping, bends etc and other similar work as required and specified including necessary form work ,complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel surface & applying two coats of synthetic enamel paint over a coat of red oxide on surface of any discription , over 10cm in width or girth, not otherwise described ,complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick Sand Texture mineral board fine fissured in true horizontal level of size 600mm x 600 mm as in false ceiling hot dipped galvanized steel section, exposed surfaces with precoated capping, main centre to centre of size 24mm x 32mm having 0.27 mm gauge at every 1200mm centre to centre and wall angle of size 19mm x 19mm having 0.35 mm gauge fixed to the periphery of the wall . The above grid is suspended at every 1200mm c/c on both directions using 3 mm thick prestrightened GI wire, laying etc. comnplete as directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 Cum, in Hard and dence soil ,getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,watering, and removing surplus soil to a distance n exc 50 m and making good surface etc.complete all as specified and as directed by Engineer-in-charge
M&L for PCC (1:3:6) type C-2 ( using 40mm graded stone aggregate ) as in foundations, filling & mass concrete etc.complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundation ,filling & mass concrete etc.complete all as specified and as directed by Engineer-in-charge.
S&F , Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) etc.Fe410W(GdeE-250 Quality B) including fabrication & erection fixing complete etc ,all as specified and directed by Engr-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge. .
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engr-in-Charge.
M&L for 75mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor and manhole etc finished even and fair all as specified and directed by Engr-in-Charge.
M&L for Chequered cement concrete tiles 20cm x 20cmx 25mm thick,set for 15mm thick screed bed in CM 1:4 for receiving floor finished ,jointed and pointed in floor with neat cement slurry with grey cement & pigment with glossy finish all as specified and directed by Engr-in-Charge
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing in SSR,all as specified and directed by Engr-in-Charge.
S&F Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F extruded aluminium alloy handles 150mm fabricated type, anodised complete all as specified and directed by Engr-in-Charge
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate, in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed and all as specified and directed by Engr-in-Charge
S&F 500 Ltr Rotational moulded polyethene water storage tanks triple layered (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I ,all as specified and directed by Engr-in-Charge
S&F 25mm Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed all as specified and directed by Engr-in-Charge
M&L for 25mm bore medium grade G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors all as specified and directed by Engr-in-Charge
Cutting existing 25mm steel tubing for alterations or additions in any position without taking down (Each cut measured) all as specified and directed by Engr-in-Charge
M&L for 20mm bore medium grade G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors all as specified and directed by Engr-in-Charge
Cutting existing 20mm steel tubing for alterations or additions in any position without taking down (Each cut measured) all as specified and directed by Engr-in-Charge
S&F 20mm Stop valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed all as specified and directed by Engr-in-Charge
M & L for Point wiring with 1.5 Sq mm copper conductor single core flame retardant PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC rigid concieled conduit and its accessories of suitable size, medium grade ISI marked surface on walls /roof and MS pressed steel terminal boxes of 1.6 mm thick of suitable size duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement incl provision of 3 mm thick bakelite hylem sheet for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified ,complete all as specified and directed by Engr-in-charge.For the following :-
One light/Bell point controlled by one, one way switch 5 Amps.
One Ceiling Fan / exhaust fan point controlled by one, one way switch.
One 3 pin 5 Amps socket out let on same board.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
Ditto as per Item No 70.00 above but with 2.5 Sq mm copper conductor
S&F Modular switch 1 way 6A,1 module, 220 V ,complete all as specified and directed by Engr-in-charge . Make : Ancor/Havells/Kinjal/Crabtree/Legrand
S & F Modular switch 1 way 16A,1 module, 220 V ,complete all as specified and directed by Engr-in-charge .Make : Ancor/Havells/Kinjal/Crabtree/Legrand
S & F Modular socket 6A-2/3 pin combined 2 modular flush type 220 V ,complete all as specified and directed by Engr-in-charge . Make : Ancor/Havells/Kinjal/Crabtree/Legrand
S & F Modular socket 6A/16A-2/3 pin combined 2 modulas flush type 220 V ,complete all as specified and directed by Engr-in-charge .Make : Ancor/Havells/Kinjal/Crabtree /Legrand
S & F Modular Bell push button flush type 5 Amps ,complete all as specified and directed by Engr-in-charge. Make : Ancor/Havells/Kinjal/Crabtree
S & F Modular fan regulator Electronics step type 120 watts 2 moduls and connecting ,complete all as specified and directed by Engr-in-charge .Make : Ancor/Havells/Crabtree
S & F Modular white cover plate with frame suitable for 1 module ,complete all as specified and directed by Engr-in-charge. Make : Legrand/Ancor/Havells
S & F Modular white cover plate with frame suitable for 3 modul ,complete all as specified and directed by Engr-in-charge. Make : Ancor/Havells/Kinjal/Crabtree/Legrand
S & F Modular Metal flush box suitable for 1/2 module ,complete all as specified and directed by Engr-in-charge. Make : Legrand/Ancor/Havells//Legrand
S & F Modular Metal flush box suitable for 3 module ,complete all as specified and directed by Engr-in-charge. Make : Ancor/Havells/Legrand/Crabtree
S & F Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals white color ,complete all as specified and directed by Engr-in-charge. Make : Ancor/Havells/Crabtree
S & F and fix bell multi music AC 230 volt single pole ,complete all as specified and directed by Engr-in-charge .Make : Ancor/Havells/Crabtree
S&F sheet metal enclosure plug and socket with 200 Amps rated bus bar 240 volts with one MCB SP 20 Amps ,complete all as specified and directed by Engr-in-charge
M & L Submain wiring PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC rigid conduit heavy duty ISI marked and its accessories including one run of single core 1.5 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board complete all as specified and directed. make: Polycab,Havells,Anchor,RR cable.For the following:-
With 2 runs of single core 4 sqmm
With 2 runs of single core 6 sqmm
S&F socket two in one ,5 Pin, 5 Amps 230 V AC supply ,complete all as specified and directed by Engr-in-charge, Make : Anchor/Legrand/C&S/havells
S&F Switch socket combination (multi purposes) 6 Pin 15 Amps ,complete all as specified and directed by Engr-in-charge.Make : Anchor/Legrand/C&S/havells
S & F sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system ,complete all as specified and directed by Engr-in-charge.Make-Benlo/Havells/Legrand/Indo Asian/Standared
S&F MCB TPN 415 volt 63 Amp,"C" Curve 16kA breaking capacity ,complete all as specified and directed by Engr-in-charge. Make-Benlo/Havells/Legrand/Indo Asian/Standared
S & F MCB SPN 230 volts suitable for fixing on MCB DB of capacity 5 to 30 Amps ,complete all as specified and directed by Engr-in-charge. Make-Benlo/Havells/Legrand/Indo Asian/Standared
S & F MCB SP 5 to 30 Amps 240 volts for fixing on MCB DB's ,complete all as specified and directed by Engr-in-charge. Make-Benlo/Havells/Legrand/Indo Asian/Standared
S&F copper strip of 20x3.00 mm as roof conductor and down conductor till test point ,complete all as specified and directed by Engr-in-charge .Note:-Copper strip to be jointed through brazing only.
Supply & fix fans wall mounting 230 volts single phase, 50Hz oscillating 450/18" mm sweep Thunder storm ,complete all as specified and directed by Engr-in-charge.
S & F LED Pluto NEO Panel 2x2, 34/36 Watt environmental frindly, new generation aesthetically design, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Amstrong/Grid ceilling all in one fixture and removal old existing unsv tube from fitting ,complete all as specified and directed by Engr-in-charge
S & F LED 15 Watt indoor commercial integra environmental frindly, new generation aesthetically design, ultra modern recess mounting LED downlighter elegently design pressure di cast Al. heat sink for heat dissipasion n cluding suitable driver all in one fixture and removal old existing unsv tube from fitting ,complete all as specified and directed by Engr-in-charge
Supply & fix Type 1+2 surge protection device TP+N high discharge current Imax 50 Ka (L-N) 70ka (N-E) COMPACT SIZE INTEGRATED Type-1 & Type-2 protection in small module width. Ideal in all reduced size plants. Better voltage protection level 1.5kV complete all as specified and directed by Engr-in-charge
M & L for exhaust fan AC single phase 23/240 Volt with 3 Number of blades and louvers, including cutting wall in required shape and size for cercular opening (hole) and after fixing the exhaust fan, the wall surface shall be made with existing surface by PCC/plastering and painting complete all as specified and directed by Engr-in-Charge at site.For the following:-
For Sweep blade of size 230 mm long
For Sweep blade of size 450 mm long
Atharva Enterprises
Biju Construction & Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .