| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹19.6 L+₹1.7 L (9.59%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | Rejected-Technical NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | - | Rejected-Technical Not meeting eligiblity criteria. Category c (i) repairs only | |
| 4 | Rejected-Technical | - | Rejected-Technical Not meeting eligiblity criteria. Category c (i) repairs only |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
14 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
86512E8 SPL REP AND ADDL PROV OF COOLING TOWERS AND ALLIED WORKS AT OTA UNDER GE STM CHENNAI
2022_MES_523764_1
86512E8IIND
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
STM CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE STM CHENNAI
₹37,000
Yes
13 Aug 2022
12 May 2022
21 Jun 2022
12 May 2022
14 Jun 2022
1 Jun 2022
12 May 2022 - 19 May 2022
60 days
Amount
REVISED BOQ UPLOADED ON 28 MAY 2022, BOQ UPLOADED ON 12 MAY 2022 CANCELLED
SCH "A" PART-I (CIVIL WORKS)
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of unserviceable debris out of MD land complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Hardcore of gauge not exceeding 63mm of broken stone aggregate, deposited, spread and levelled in layers not exceeding 150mm thick, watered and rammed to a true surface complete all as specified and as directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in plinth beam, footing, bases of columns etc., complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, shelves and the like complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in columns, pillars etc., complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-30, (Design Mix), using 20mm graded stone aggregate as in beams, lintels over 1.5m span complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, shelves and similar work not exceeding 200mm thick (horizontal or sloping) rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides of columns, pillars, stancions and similar work; square, rectangular or polygonal rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor / roof beams and similar items including edges rough finished surfaces of concrete complete all as specified and as directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe 410 -W (GdeE- 250) quality A complete all as specified and as directed.
Rolled mild steel sections as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. of Fe 410 -W (GdeE- 250) quality A complete all as specified and as directed.
Plain cement concrete, 1:2:4, type B0, using 12.50mm graded stone aggregate, 40mm thick as in floor, finished fair and even complete all as specified and as directed.
Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate, 75mm thick as in sub-base complete all as specified and as directed.
Rendering 15mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces as in walls finished fair and even complete all as specified and as directed.
Rendering 5mm thick in CM(1:3) on fair faces of concrete surfaces as in ceiling finished fair and even complete all as specified and as directed.
Preparing newly plastered surfaces of ceiling and applying three coats of white wash on plastered ceiling surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed.
Preparing newly plastered surfaces of wall,, applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
SCH "A" PART-II (AIR CONDITIONING)
Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit and provision steel tubing, galvanised, medium grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls and ceilings or laid in floors of bore of pipe 50mm complete all as specified and as directed.
Gun metal, globe or gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 50mm as in repairs complete all as specified and as directed.
Old gate valve retrieved shall be handed over to the storeyard of AGE E/M STM, Chennai.
Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 40mm-690gms) bore of pipe 40mm as in repairs complete all as specified and as directed.
Old ball valve retrieved shall be handed over to the storeyard of AGE E/M STM, Chennai.
Taking out existing cable and provision of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of 4 core, cross sectional area 16 sqmm complete all as specified and as directed.
(a) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(b) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(c) Old cable retrieved shall be handed over to the storeyard of AGE E/M STM, Chennai.
Supply, installation, commissioning and testing of induced draft top discharge counterflow type FRP Cooling Tower with FRP body and base, PVC fills, high efficiency fan, fan motor, drift eliminator, water spray headers, ladder, SS bolts and nuts, float valve, quick fill connections, suitable inlet / outlet connection with existing system, supporting base frames etc, of size 100 TR suitable for 2 x 75 TR AC Plant all as per specifications and as per manufacturer's standard instructions complete all as specified and as directed.
(a) RCC staging required for the cooling tower as required shall be measured and paid separately.
(b) The place of installation of cooling tower is Auditorium of OTA, Chennai.
(c) The design ambient wet bulb temperature shall be 27.8 degree celsius.
(d) The outlet water temperature from cooling tower shall not be more than 32.2 degree celsius.
(e) Total heat rejection of cooling tower shall be 6 to 8 degree celsius i.e suitable for operation of 2 x 75 TR AC Plant (01 x 75 TR Running and 01 x 75 TR Standby).
(f) The old cooling tower shall be dismantled and handed over to MES Storeyard of GE STM Chennai and the rate quoted is deemed to include for the same.
(g) All requirements like connecting the pipes to the existing system with necessary bolts, nuts, washers, gaskets, minor fittings and fixtures etc., contingent for satisfactory commissioning of the cooling tower is deemed to be included in rate quoted.
Supply, installation, commissioning and testing of induced draft top discharge counterflow type FRP Cooling Tower with FRP body and base, PVC fills, high efficiency fan, fan motor, drift eliminator, water spray headers, ladder, SS bolts and nuts, float valve, quick fill connections, suitable inlet / outlet connection with existing system, supporting base frames etc, of size 200 TR suitable for 2 X 100 TR AC Plant all as per specifications and as per manufacturer's standard instructions complete all as specified and as directed.
(a) RCC staging required for the cooling tower as required shall be measured and paid separately.
(b) The design ambient wet bulb temperature shall be 27.8 degree celsius.
(c) The outlet water temperature from cooling tower shall not be more than 32.2 degree celsius.
(d) Total heat rejection of cooling tower shall be 6 to 8 degree celsius i.e suitable for operation of 3 X 100TR AC Plant (2 X 100 TR) Running and 1 X 100 TR Standby).
(e) All requirements like connecting the pipes to the existing system with necessary bolts, nuts, washers, gaskets, minor fittings and fixtures etc., contingent for satisfactory commissioning of the cooling tower is deemed to be included in rate quoted.
Supply, installation, testing and commissioning of centrifugal monoblock electrically driven pumpset with impeller capable of self priming, with high pressure die cast iron motor body, mounted on commom base plate including suitable size flanged valve, necessary PCC foundation works, bolts and nuts for anchoring the pumpset and motor complete all as specified and directed.
(a) Material of Construction
(i) Impeller - Cast iron
(ii) Delivery Casing - Cast Iron
(iii) Motor Body - Cast Iron
(iv) Pump shaft - Stainless steel
(v) Mechanical seal
(b) Phase - Three Phase, AC, 50 Hz
(c) Voltage - 415 V
(d) Capacity - 15.0 HP (11 kW)
(e) Pipe size suction x discharge - 100mm x 100mm
(f) Discharge-2140 LPM to 1150 LPM
(g) Head- 18m to 36m
(j) Any other requirement as per OEM is deemed to be included in the rate quoted.
Mild steel pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of 125mm bore of pipe including cutting and welding as per site requirement as in repairs complete all as specified and as directed.
Old steel pipes retrieved shall be handed over to the storeyard of AGE E/M STM, Chennai.
Butterfly valve, wafer type, Class PN 1.6, with cast iron body and disc, suitable for 150mm bore of pipe with necessary fixing arrangements such as fasteners, nitriles or EDPM rubber lining, stainless steel pins, ring, bolts and nuts etc as in repairs complete all as specified and as directed.
Old butterfly valve retrieved shall be handed over to the storeyard of AGE E/M STM, Chennai.
Strainers with cast iron body ‘Y’ type with flanges and with removable stainless steel screen with 3 mm perforations suitable for 150mm bore of pipe with necessary fixing arrangements such as fasteners, etc as in repairs complete all as specified and as directed.
Old strainer retrieved shall be handed over to the storeyard of AGE E/M STM, Chennai.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 32mm x 6mm dia GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Glacier Cooling Solutions Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .