Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.2 LAccepted-AOC SHOP NO 48 HOSANNA LAXMI VENKETESWARA LAYOUT 2ND CROSS MARAGONDANAHALLI K R PURAM POST BANGALORE 560036 | BENGALURU URBAN | KARNATAKA | 560036 | L1 | Accepted-AOC L1 | |
| 2 | L2₹86.9 L+₹4.0 L (4.87%)Rejected-AOC | L2 | Rejected-AOC NOT L1 | |
| 3 | L3₹1.1 Cr+₹25.1 L (30.2%)Rejected-AOC FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-AOC NOT L1 |
| Sl No | Description | Qty | Unit | M/S G.N.POWAR L2 | M/s J.D. DESAI L3 | AURA ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Cleaning of reinforcement from rust from the reinforcing bars of any size of bar to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, and applying two coats of epoxy based zinc primer in a span of 4 hours over the treated re-bar & allow to dry for 6 hours, complete all as specified and directed. | 1,800 | RM | 40 ₹72,000 | 19 ₹34,200 | 18 ₹32,400 Lowest |
| 2.00 | Chipping of unsound/weak concrete material 35-45mm average thickness from slabs, beams, columns etc. similar surfaces with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. complete with necessary formwork/scaffolding/ staging (till completion of structural repair) and disposal of debris outside MD land for all lead and lifts all complete all as specified and directed. | 175 | Sqm | 50 ₹8,750 Lowest | 426 ₹74,550 | 218 ₹38,150 |
| 3.00 | All as per item No. 2 but average thickness 45-65mm complete as specified and directed | 120 | Sqm | 60 ₹7,200 Lowest | 478 ₹57,360 | 338 ₹40,560 |
| 4.00 | All as per item No. 2 but average thickness 65-85mm complete as specified and directed | 95 | Sqm | 120 ₹11,400 Lowest | 492 ₹46,740 | 344 ₹32,680 |
| 5.00 | Material and labour for mixing and applying polymer modified Cement mortar over bonding agent 35-45mm average thickness in one or more layers, provision of protection coating on finished concrete complete as specified and directed | 175 | Sqm | 2,350 ₹4,11,250 Lowest | 4,585 ₹8,02,375 | 3,270 ₹5,72,250 |
| 6.00 | All as per item No.5 but average thickness 45-65mm complete as specified and directed | 120 | Sqm | 2,550 ₹3,06,000 Lowest | 6,423 ₹7,70,760 | 4,138 ₹4,96,560 |
| 7.00 | All as per item No.5 but average thickness 65-85mm complete as specified and directed | 95 | Sqm | 2,850 ₹2,70,750 Lowest | 8,097 ₹7,69,215 | 5,331 ₹5,06,445 |
| 8.00 | Supply and fix high strength deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm (including welding/drilling to old TMT bars wherever necessary) dia complete all as specified and directed. | 1,800 | Kg | 90 ₹1,62,000 | 88 ₹1,58,400 Lowest | 112 ₹2,01,600 |
| 9.00 | Supply and fix high strength deformed TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia (including welding/drilling to old TMT bars wherever necessary) complete all as specified and directed. | 1,000 | Kg | 90 ₹90,000 Lowest | 90 ₹90,000 Lowest | 116 ₹1,16,000 |
| 10.00 | Cutting down the plants/ trees of girth n.exc. 15cm from roof tops/ sides of external walls of building, chajja, wall junctions & at junctions of rain water/ waste water pipes including taking out the roots entered in to wall/ slab surfaces; making good surfaces with PCC 1:2:4 type B0 or cement mortar (1:2) including repairing the GI/ CI/ PVC pipe joints which were affected due to cutting/ taking out process after applying suitable herbicide including making good the disturbed surfaces to match the adjoining surfaces complete with necessary scaffolding/ staging/ Jhula etc, with all necessary safety precautions up to 4 storey height complete all as directed and as specified. | 49 | Each | 250 ₹12,250 | 226 ₹11,074 Lowest | 318 ₹15,582 |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
11 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL SAIKAT DE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIRS TO DISTRESSED CONCRETE STRUCTURE/BUILDING IN VARIOUS LOCATIONS AND CERTAIN OTHER WORKS AT INHS JEEVANTI VASCO UNDER GE GOMANTAK
2025_MES_706833_1
85951
Open Tender
Civil Works
Item Rate
Vasco
As per tender
9 documents required · 9 mandatory
₹1,000
GE Gomantak
₹1.8 L
Yes
8 Sept 2025
6 May 2025
13 Aug 2025
6 May 2025
11 Aug 2025
28 Jul 2025
Amount
Cleaning of reinforcement from rust from the reinforcing bars of any size of bar to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, and applying two coats of epoxy based zinc primer in a span of 4 hours over the treated re-bar & allow to dry for 6 hours, complete all as specified and directed.
Chipping of unsound/weak concrete material 35-45mm average thickness from slabs, beams, columns etc. similar surfaces with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. complete with necessary formwork/scaffolding/ staging (till completion of structural repair) and disposal of debris outside MD land for all lead and lifts all complete all as specified and directed.
All as per item No. 2 but average thickness 45-65mm complete as specified and directed
All as per item No. 2 but average thickness 65-85mm complete as specified and directed
Material and labour for mixing and applying polymer modified Cement mortar over bonding agent 35-45mm average thickness in one or more layers, provision of protection coating on finished concrete complete as specified and directed
All as per item No.5 but average thickness 45-65mm complete as specified and directed
All as per item No.5 but average thickness 65-85mm complete as specified and directed
Supply and fix high strength deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm (including welding/drilling to old TMT bars wherever necessary) dia complete all as specified and directed.
Supply and fix high strength deformed TMT steel bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia (including welding/drilling to old TMT bars wherever necessary) complete all as specified and directed.
Cutting down the plants/ trees of girth n.exc. 15cm from roof tops/ sides of external walls of building, chajja, wall junctions & at junctions of rain water/ waste water pipes including taking out the roots entered in to wall/ slab surfaces; making good surfaces with PCC 1:2:4 type B0 or cement mortar (1:2) including repairing the GI/ CI/ PVC pipe joints which were affected due to cutting/ taking out process after applying suitable herbicide including making good the disturbed surfaces to match the adjoining surfaces complete with necessary scaffolding/ staging/ Jhula etc, with all necessary safety precautions up to 4 storey height complete all as directed and as specified.
Material and labour for cleaning of roof tops including removing the existing treatment by brooming down with steel wire brushing scrapping down with steel scrapper and roughening the existing surfaces to receive plaster complete all as directed and as specified. Note: The debris out the cleaning/removing/ scraping shall be removed out MD Land complete all as specified and directed.
Providing erecting, removing and taking away steel tubular scaffoldings/formwork using vertical props, horizontal ties and diagonal bracings and other necessary members, nuts, bolts, clamps etc. complete as directed. The scaffolding/formwork shall be retained till the work is completed in all respects including curing etc. and after completion of the work; the scaffolding/formwork shall be dismantled and removed out of the premises complete all as specified and directed. Note : formwork to support existing structure and paid as floor area of supporting structure
Drilling 12mm dia holes up to a depth of 75mm maximum and fixing 8mm dia L shaped anchor rods as shear connectors at every 300mm c/c on the surfaces of the columns/beams or any other structural member as the case may be. Clean the same using water and make sure that there are no fine particles present in the hole. Fill the drilled & cleaned holes to a minimum depth of 2/3rd of the hole with the Lokfix E77. Make sure that the resin has reached till the end of the hole. At this stage push the shear connector gently in to the hole & finish the excess resin which comes out of the hole & allow the shear connectors not to be disturbed for min 20 minutes complete all as specified and directed. The rate shall including the cost of all the operations & etc
Providing and fixing the Chemical Anchor Fasteners as specified below of Hilti Make or equivalent confirming to IS 1367 (Part 3) at required locations and level including drilling the hole, cleaning with blow pump and anchoring the bolt with chemical as per manufacturers specifications etc. complete all as specified and directed. (a) M10 x 90 foil capsule (HVU) & M10 x 130 Rod
(b)M16 x 125 foil capsule (HVU) & M16 x 190 Rod
(c) M20 x 170 foil capsule (HVU) & M20 x 240 Rod
Material and labour for 25mm thick cement concrete (1:2:4) type B0 (using 12.5mm graded aggregate) as in leveling course of slab complete all as specified and directed.
Material and labour for providing 10mm thick cement plaster over roof slab (over the area of dismantled roof treatment ) in cement mortar 1:3 finished even and smooth without using extra cement with WPC complete all as specified and directed. (Note: WPC shall be measured and paid separately)
Material and labour for water proofing treatment to the roof slab using 4mm thick APP modified membrane consisting five layer membrane with features as specified, weighing not less than 4.0Kg/m2 laid over a coat of cold applied bitumenous primer @ 0.4 ltr per sqm on surface provide a layer of APP modified membrane by torching application including sealing the overlap with torching with 150mm on length side and 100mm on width side as per manufacture's instruction including joints and changes in direction be covered with thin cement slurry in CM 1:3 mixed with SBR latex @ 200ml/bag of cement curved well before laying of membrane all as per manufacturer's instruction and provide two finishing coat with solar reflective bituminous aluminium paint @ 0.20Kg/m2 as prescribed by manufacturer of membrane complete all as specified and directed. Note:- (i) Irrespective of the lap the net covered area will only be measured for payment. (ii) The quoted rate is deemed to be inclusive of bituminous primer, APP membrane , solar reflective bituminous aluminium paint & SBR latex.
Demolition of brickwork or stone/boulder masonry wall, built in cement mortar complete all as specified and directed.
Material and labour Pre-cast cement concrete block masonry Type C1 1:3:6 20mm graded aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, ceilings etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Material and labour rendering 15mm thick on stone masonry surfaces or surface other than fair face of brick work in cement mortar 1:6 in patches finishing the surfaces even & smooth complete all as specified and directed.
Material and labour rendering 5mm thick with WPC over 10 mm thick on concrete surfaces or fair face of brick work or PCC block masonry in CM 1:4 finishing the surfaces fair and even complete all as specified and directed.
Supply only integral water proofing compound
Material and labour for preparing new plastered surfaces of walls Chalk whiting, on plastered surface and applying two coats of oil bound distemper complete all as specified and directed.
Material and labour for preparation of new surfaces of walls by means of using jet water spray machine wash down existing treatment and preparation of old surfaces wall/ceiling by scrapping/rubbing applying two coats of Advanced Anti-algal Weather Proof 100% Acrylic smooth emulsion with silicon additives, over a coat of fiber reinforced elastomeric liquid water proofing membrane on old plastered surfaces walls/ceiling and cornices bromming down or steel wire brushing scrapping down with steel scrapper smoke soot moulds moss and efflorescent slats brading oil and greasy spots etc and making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions and as specified and directed. Note: The application of paint to be done by the authorised applicators oapproved make and also the dealer shall appoint a person to inspect and validate the application of the system in stage wise manner.
Material and labour for complete removal of existing treatment by means of using jet water spray machine wash down existing treatment and preparation of old surfaces wall/ceiling by scrapping/rubbing applying two coats of Advanced Anti-algal Weather Proof 100% Acrylic smooth emulsion with silicon additives, over a coat of fiber reinforced elastomeric liquid water proofing membrane on old plastered surfaces walls/ceiling and cornices bromming down or steel wire brushing scrapping down with steel scrapper smoke soot moulds moss and efflorescent slats brading oil and greasy spots etc and making proper surface by applying ready mix preparatory wall care putty of Birla wall Care or equivalent wherever required complete all as manufacturers instructions. Note: The application of paint to be done by the authorised applicators of approved make and also the dealer shall appoint a person to inspect and validate the application of the system in stage wise manner.
Material and labour for preparing new plastered surfaces of ceiling and applying three coats of white wash.
Material and labour preparation of new plastered or un plastered surfaces and applying three coats of white wash
Demolition of cement concrete etc in any description/any location not exceeding 15 cm thickness.
Material and labour for cement concrete type B-1, 1:2:4 (20mm graded aggregate) 40mm thick finished fair & even w/o using extra cement complete all as specified and directed.
Material and labour cement concrete type D2, 1:4:8 (40mm graded aggregate) 75 mm thick as in sub base leveling course complete all as specified and directed.
Material and labour for 75mm thick PCC 1:3:6 ,type C2( using 40mm graded stone aggregate) as in plinth protection, path etc. including provision of grade A sealants complete all as specified and directed.
Material and labour providing cement concrete type C1 1:2:4 (20cm graded aggregate) in coping work, over chajjas, Compound walls and other similar works etc complete with necessary scaffolding/ staging/ Jhula etc, with all necessary safety precautions up to 4 storey height complete all as directed and as specified.
Taking down shutters of any description n exc 1 sq. m each including easing and adjusting and refixing the shutters in same opening including renewal of unserviceable screws, etc complete all as specified and directed
Taking down shutters of any description exc 1 sqm but not exc 2.00 sq. m each including easing and adjusting and refixing the shutters in same opening including renewal of unserviceable screws, etc complete all as specified and directed
Taking down Chowkats or frame exc 1.5Sqm and not exc. 4Sqm each with shutters (without taking off shutters from the frames), all as specified.
Taking down Chowkats or frame not exc 1.5Sqm each with shutters (without taking off shutters from the frames), all as specified.
Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Supply and fix powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
Supply and fix in 4.8 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beading in squares not exc 0.5 Sqm each pane fixed in aluminium windows/door/portions complete all as specified and directed
Dismantling floor, hearth or wall tiling also in patches including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material and labour Coloured non skid/Anti skid ceramic tiles 8 to 10 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, ramp, steps, riser etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6. completed all as specified and as directed.
Material and labour Glazed Ceramic Coloured Tiles, 300X450X7-10 H or ceramic designer tiles in any size, set on Vertical Surfaces such as Skirting, Dado, etc, over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed.
Material and labour Vitrified Ceramic tiles 9 to 10 mm thick light shade (also in patches) square/ rectangular polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Supply and fix (in repairs) Low level flushing cistern 10 Litre capacity moulded from virgin poly propylene Make Parry ware Brand Slimline Single flush including provision of 32 mm dia PVC flush pipe and making connections, ISI marked or equivalent of other make specified ccomplete all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Supply and fix in repair vitreous china wash basin (WHB), white, flat back, size 550mmx400mm including Cl cantilever brackets. 32 mm dia brass Chromium plated waste fittings with long screw shanks and fly nuts, flange end Embedded in red lead cement, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply pipe and supply of taps complete all as specified and directed.
Supply and fix in repair Vitreous China wash down water closet pan (pedestal pattern), white (flushing cistern and flush pipe) complete all as specified and directed.
Supply and fix in repair PVC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hanging devices approved by GE complete all as specified and directed.
Supply and fix (in repairs) CP Angle stop cock two way screwed down for 15 mm bore dia pipe, high pressure, with crutch handle screwed externally both ends for unions etc. and fixed C complete all as specified and directed.
Supply and fix in repairs 15mm Bib taps, long nose fancy type chromium plated with crutch or butterfly handle, screwed down. screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix in repairs grating doom type 100mm dia of stainless steel (min wt 25gms)
Dismantling reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for including necessary reinforcements wherever necessary., complete all as specified and as directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc. rough finished surface of concrete, square, rectangular etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions, rough finished surface of concrete, square, rectangular etc. complete all as specified and directed.
Formwork to soffits of suspended slabs such as chajjas n.exc 200m thick (Horizontal or sloping) complete all as specified and directed.
Material and labour for RCC ((design mix) M-30(20mm graded aggregates) in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material and labour for RCC (design mix) M-30 (20mm graded aggregates) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and labour for RCC (design mix) M-30(20mm graded aggregates) in Chajjas/slab complete all as specified and directed.
Dismantling Mild steel work in any location complete all as specified and directed.
Material and labour for rolled sections Fe 410 gde E 250 as in framing, roof covering for cladding, glazing and the like fixed with angle cleats and connecting plates, etc complete all as specified and directed.
Material and labour preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enameled paint over one coat of red oxide Zinc chrome primer complete all as specified and directed.
Supply and fix Pre-painted galvalume aluminum zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/chajja), fixed with self tapping screws complete all as specified and directed.
Removing building/wall material etc to a distance out of MoD Land beyond the lead including in the rates, including loading, unloading & stacking at the destination and Each load of material not less than 5 Cum complete all as specified and directed.
Material and labour for crack treatment on plastered/concrete wall and ceiling surfaces by forming a ‘V’ groove of 5 mm width and 5 mm depth along the existing crack line using an electrically operated angle grinder / concrete saw blade, followed by thorough cleaning using an air blower as directed by the Engineer-in-Charge.Subsequently, the groove shall be sealed with a solvent-free, moisture-tolerant, thixotropic, two-part structural adhesive and epoxy repair mortar-cum-surface levelling compound of approved make complete all as specified and directed. Note : Application shall be executed only by authorised applicators certified by the respective manufacturers.
Material and labour for structural repair using micro-concrete including the following, preparation of concrete surface by removing all loose/damaged concrete and cleaning to expose sound concrete. application of epoxy-based bonding agent of approved make, providing and fixing suitable formwork/shuttering to prevent leakage during placement. Mixing and placing ready-to-use, non-shrink, flowable micro-concrete of approved make,by pouring or pumping into prepared sections. All work to be executed as per manufacturer’s instructions complete all as specified and directed. Note: Application to be carried out only by authorised applicators certified by the manufacturer. Rate to include all labour, materials, tools, curing and scaffolding/supports etc complete in all respects.
Material and labour for applying one coat of primer under tow coats fo smartcare PU Aqua of Asian paints ro equivalent in sika, fosroc and applying one coat of exterior emulsion paint to match the existing surface complete all as specified and directed.
Material and labour for shifting of window/split AC's from existing location into New location dismantling of window/split AC's with electrical connection carefully and transported to New location as directed by the Engr-in-charge and cutting of window grill /brick wall including making good patches both the location & servicing of said AC's including point wiring suitable for window/split AC's not less than 215 sqmm (copper conductor and fixing of plug for window AC's remaining area complete all as specified and directed.
Supply & fix in replacement of AC stand wall mounted/floor mounted type suitable for existing type/Model of AC's complete all as specified and directed.
Supply and charging refrigerant gas R-22/R-32 up to required level including connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed by Engr-in-Charge. Note : Above second floor contractor will arrange Crain / scaffolding with safety device) Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
Material and labour for servicing of Split type AC 1.5/2 Ton capacity comprising of thorough cleaning, lubricating of all moving parts, replacement of worn-out screws, bolts etc to make the unit for smooth operation complete all as specified and directed.(Note : Above second floor contractor will arrange Crain / scaffolding with safety device)
Preparation of old painted surfaces of Split type AC 1.5/2 Ton Capacity, painting with two coats of synthetic enamel paint by spraying complete all as specified and directed.(Note : Above second floor contractor will arrange Crain / scaffolding with safety device)
Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (Note : Above second floor contractor will arrange Crain / scaffolding with safety device) Split type AC 1.5/2.0 Ton capacity.
Supply and replace capacitors of the following capacities for ACs (a) 4/6 Mfd
( c) 36 Mfd 6 pin
(f) 45+6 Mfd Seven Pin
Replace after cutting of worn out bottom portion and fabricated / welded properly of bottom tray with suitable size of GI plate of Split type ACs any capacity and make and welding of legs including supply fixing suitable size of angle iron legs of any make complete all as specified and directed.
Supply and replace starting relay suitable for Split type AC 1.5/2 Ton capacity complete all as specified and directed.
Supply and replace thermostats of Split type AC 1.5/2 Ton capacity complete all as specified and directed.
Supply and replace overload protector of Split type AC 1.5/2 Ton capacity complete all as specified and directed.
Supply and replace copper condenser unit of Split type AC 1.5/2 Ton capacity including making of all connections as complete all as specified and directed.
Supply and replace of evaporator coil of Split type AC 1.5/2 Ton capacity to suit existing AC complete all as specified and directed.
Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, copper conductor cable drawn in and including 25/32mm wide PVC casing and capping with all accessories such as tees, elbows, junction box, reducers etc as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion including taking down old submain wiring of any type with conduit complete all as specified and directed. Note : 3 runs of 4 Sqmm cable, and 1 run of PVC casing/capping 25mm/32mm wide shall be measured as single run complete all as specified and directed.
Supply & Fixing of DBOXX protected socket AC Box with one single pole MCB 240 Volts 20 Amps complete all as specified and directed.
Supply and replace MCB SP 5 to 30 Amps 250 Volts complete all as specified and directed.
Supply and replace contact unit of split type AC of 1.5/2 Ton cap to suit existing AC complete all as specified and directed.
Supply and replace internal wiring but complete suitable for Split type AC of any make and capacity 1.5/2ton complete all as specified and directed.
Dismantling and removing of defective burnt motor from Split type AC of any make and capacity 1.5/2 ton and rewinding the motor with enamel copper winding wire including replacement of worn - out motor bearing ,refixing and testing complete all as specified and directed.
Supply and replace suitable blower/condenser fan motor complete with necessary mounting bracket to and base frames for Split type AC of any make and capacity 1.5/2 ton complete all as specified and directed.
Supply and replace suitable indoor fan unit complete suitable for cool room / cold room with existing make and capacity complete all as specified and directed.
Supply and replace heavy duty PVC flexible pipe with necessary fittings of jubilee /split Aces/Window Aces drains of 15mm dia bore complete all as specified and directed.
Supply and fix Air filter suitable for 1.5/2.0 ton split type AC of any make complete all as specified and directed.
Supply and fix insulation for copper tubes of split type AC units, insulation type superion of size 3/8"diameter complete all as specified and directed.
Supply and fix insulation for copper tubes of split type AC units, insulation type superion of size 5/8"diameter complete all as specified and directed.
Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" dia complete all as specified and directed.
Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" dia complete all as specified and directed.
Supply and fix PCB(circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC indoor unit complete all as specified and directed.
Supply and fix PCB(circuit board) complete suitable for 1.5/2.0 ton capacity Inverter type split AC out door unit complete all as specified and directed.
Supply and fix PCB complete suitable for 1.5/2.0 ton capacity split type AC complete all as specified and directed.
Supply and fix Remote control of any size and capacity of split AC complete all as specified and directed.
Supply and fix in repair Voltage stabilizer capacity of 5 KVA of range 130V to 280 V suitable for up to 2 ton Split AC complete all as specified and directed.
Supply and fix in repair indoor cooling unit with rotary fan suitable for 1.5 ton Split AC complete all as specified and directed.
Supply and fix in repair Out Door unit with rotary fan suitable for 1.5 ton Split AC complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition separately) and making good disturbed surface of walls, floors etc complete all as per the existing finish complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit and accessories concealed into wall by cutting of chases in wall/ceiling and replacement of modular metal flush box, modular white cover plate with frame, blanking plate rates are deemed quoted rates etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one the following:- (a) One light/fan/exhaust fan point controlled by one switch.
(b) One 5 pin switch socket outlet 5 Amps on same board controlled by one switch.
(c) One 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per item No 2 here-in-before but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and directed.
Supply and fix in replacement of modular switch, one way 6 Amp ,1 module
Supply and fix in replacement of modular switch, one way 16 Amp ,1 module
Supply and fix in replacement of modular socket 6 Amp, 2 / 3 pin, 1 module
Supply and fix in replacement of modular socket 6/16 Amps, 2/ 3 pin 2 module
Supply and fix in replacement of ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete.
Supply and fix in replacement of modular fan regulator flush type complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, includes min 1 mtr length down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery min 225 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make: Havells cat No- FHCNF5SWHT56/Orient model Hector 500/ Bajaj Model- ENERGOS 28(SKU Code 251100EE)
Supply and fixing in replacement of LED tube light fitting surface and wall mounted batten Aluminium body with 22/20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete made up of polycarbonate complete all as specified and directed. Make: Philips cat No-BN021CLED22S PSU CW GR/ Crompton cat no-CCS-103-20-65-SL-DP-NWH/ Halonix HLB-03-20-CW-AL-SQ.
Supply & Fixing in replacement of Recess mounting LED fittings 36 watts ,6500K, suitable for 600 mm x 600 mm (2ftx2ft) modular/POP/Gypsum ceiling, luminaire with white powder coated CRCA housing with LEDs. seamless front frame with fat white high transmission acrylic cover 230V, complete in all respect & accessories internally prewired including connecting up with twin copper twisted flexible copper conductor cable with suitable size including taking down old fitting of any type. Make: Havells cat No-VENUSNEO2X2PLR36WLED865G2/ Philips cat no-RC380B LED36S-6500 G5 L60W60 PSU OD SG / Halonix HLFPR22-11-36-CW-37mm-WC.
Supply and fix in replacement of sheet metal enclosure (DB) for MCB's, 16 way, single pole and neutral, 240 volts, double door complete all as specified and directed.
Supply and fix in replacement of sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps,C series 240 Volts complete all as specified and directed.
Supply and fix in replacement of MCB, single pole,16 Amp to 32 Amp, 240 Volts, 'C' Curve 10KA.
Supply and fix in replacement of MCB, single pole and neutral, 63 Amp, 240 Volts, 'C' Curve 10 KA.
Material and Labour in replacement of sub main wiring with single core, PVC insulated unsheathed cables two run of 4 Sq mm multi stranded copper conductor drawn through and including 25/32mm mm wide non metallic PVC conduit including all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 4 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/capping casing and making good disturbed surfaces to match existing all as specified and directed. Note : Three runs of 4 sqmm cable and one run of PVC Capping casing 25/32mm width shall be measured as one run.
Material and Labour in replacement of sub main wiring with single core, PVC insulated unsheathed cables two run of 10 Sq mm multi stranded copper conductor drawn through and including 25/32mm mm wide non metallic PVC conduit including all accessories fixed on walls/roof/floors/ceiling etc with an earth wire of one run 10 sqmm copper wire earth continuity conductor connecting to existing main switch board \ Distribution Board and testing on completion etc including taking down old submain wiring of any type with conduit/capping casing and making good disturbed surfaces to match existing all as specified and directed. Note : Three runs of 10 sqmm cable and one run of PVC Capping casing 25/32mm width shall be measured as one run.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth for Laying of UG cable getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth for Laying of UG cable getting out soft disintegrated rock complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed.
Supply, Laying, joining & testing in replacement of LT XLPE Insulated & sheathed armoured electric cables with aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection for following cross- sectional areas complete all as specified and directed. (a). 95 sqmm 3.5 core
(b) 185 Sqmm 3.5 Core
Supply and fix for DWC high density polyethylene pipes 80mm inner dia size having outer side wall corrugated and inner surface plain confirming to IS 14930 (Part-I & II) for protection of underground cable laid in trenches/floor/fixed on pole/wall including all fittings(coupler) and clamps as required complete all as specified and directed.
Removal and refixing on walls using MS angles after building work completed of LT UG cable of any size with any damage of cable fix with proper clamps, lugs . Note:- (i). The tenderer shall make sure to remove and refix the cable to avoid any damage to cable. The interuption of power supply more than two hour will be fined at suitable rates (ii) MS clamps and joint kit if any required is deemed to be included in the quoted rates.
M/S G.N.POWAR (BID ID -3375997)
M/s J.D. DESAI (BID ID -3382213)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .