Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹47.9 L+₹3.0 L (6.70%)Rejected-Finance | L2 | Rejected-Finance High Rate Quoted | |
| 3 | L3₹51.4 L+₹6.5 L (14.4%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L3 | Rejected-Finance High Rate Quoted | |
| 4 | L4₹54.0 L+₹9.1 L (20.2%)Rejected-Finance | L4 | Rejected-Finance High Rate Quoted | |
| 5 | L5₹54.4 L+₹9.5 L (21.1%)Rejected-Finance | L5 | Rejected-Finance High Rate Quoted |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
12 Dec 2023, 6:00 pmClosed
Col Shery Goel, CWE Bikaner
HQ CWE Bikaner, Bikaner Mil Stn
Repair/replacement of electric wiring and panels at MD Accn Zone A and Zone B under GE (N) Bikaner at Military Station Bikaner
2023_MES_628245_1
CA No CWE BKN-Token No. 48/2023-2024
Open Tender
Civil Works
Item Rate
270 days
GE N BIKANER
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE (N) Bikaner
₹1.6 L
Yes
24 Jan 2024
14 Nov 2023
19 Dec 2023
14 Nov 2023
12 Dec 2023
5 Dec 2023
14 Nov 2023 - 18 Nov 2023
Amount
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one light point controlled by two, two way switches complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F bell push, flush type, 5 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 3 pin (2 in 1, with 2 pin outlet also), 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.
Taking down of serviceable and refixing after LED tube light fitting mirror type with high output diffuser, 2 feet, 10 Watt, 230 Volts, decorative type with driver holder and LED lamp including connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F in replacement of LED mirror fitting 1x10 Watt, 6000 K, 2 feet, basic all purpose surface and wall mounted LED batten with powdered coated aluminium housing & integrated electronic driver & all accessories including connection with 2 core flexible copper cable 23/0.00076 from ceiling rose to fitting connection with following specification, complete all as specified and as directed :- (a) Lumen efficacy of system should be minimum 105 Lumen per watt. (b) Voltage operating range : 160 to 270 Volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10%. (f) IP rating : IP-20. (g) CRCA pre coated housing. (h) LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection device for 2.5 KV. (l) CRI : Minimum 80
S&F in replacement of LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F in replacement of bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs/MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, TPN, vertical load line, 4 way, fitted with and including following accessories, complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 12 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 4 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCCB 4 Pole 40 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 3 Pole 63 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 63 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 3 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 125 Amps, thermal magnetic release having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and as directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep, keeping side to store in safe custody for painting of ceiling fans complete, insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed.
M&L for taking down carefully existing serviceable ceiling fan with down rod / exhaust fan of any sweep and re-fixing / hanging the same after proper cleaning and connecting up with and including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto ceiling rose, complete all as specified and as directed.
M&L for carefully disconnecting electric & water connections and taking down existing serviceable Geyser (water storage type) of capacity 25/50 litre vertical type and re-fixing the same with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of suitable size but not less than 10mm dia 125mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original and re-connecting electric & water connections, complete all as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC concealed conduit, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC concealed conduit, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with Four runs of 10 sqmm (nominal area) size main cable & Two run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 32mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 02 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified and directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :-(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
Repair to existing panel board indoor type sheet metal approximate size (5X5X1.5 Feet) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges MS Sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolt in MCBs and proper legging in cable and control wire sheet metal screws and replacing of unserviceable Volt meter, Amp meter and CT, PT and painting complete body with two coats of synthetic enamel paint over a coat of zink chrome primer and marking the Qtr No, panel board No in front side and tested on completion complete all as specified and as directed.
LAKSHMI ASSOCIATES
Pioneer Enterprises
B K CONTRACTORS
Goyal Enterprises
SUBHAM ENTERPRISES
M/s Kataria Construction Company
M/s Balvinder Singh Engineer and Contractors
M/s MAKHAN ENTERPRISES
M/s Kamal Builders
B5BUILDING SOLUTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .