Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹3.5 L+₹31,900 (10.1%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest | |
| 3 | L3₹3.7 L+₹58,700 (18.6%)Accepted-Finance | L3 | Accepted-Finance 3rd Lowest | |
| 4 | L4₹4.0 L+₹86,650 (27.4%)Accepted-Finance | L4 | Accepted-Finance 4th Lowest |
Tender Value
₹3.2 L
EMD Value
₹6,332
Closing Date
29 Jul 2022, 10:00 amClosed
EE WSD APWD Port Blair
EE WSD APWD Port Blair
SITC of Air Conditioners in Gym room at DC SA office complex and in Dining room at DC Bungalow. Port Blair
2022_APWD_6768_1
DB Tender/Elect/WSD/2022-23/3285 dated 26/07/2022
Open Tender
Air-Conditioner
Works
30 days
Port Blair
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹6,332
20 Aug 2022
26 Jul 2022
29 Jul 2022
26 Jul 2022
29 Jul 2022
27 Jul 2022
26 Jul 2022 - 28 Jul 2022
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(Drain pipes for IDU of AC)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Triple pole and neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply and fixing of MCB enclosure of sheet steel, phosphatisd,power painted MCB DB,s with Din rail ( in accordance with IS 1302, IS8623, IEC/BSEN 60439-3). Of 4 ways Havells CAT NO DHDESFP or equivalent.
SITC of 02 Ton capacity Floor Standing, Tower type, 01 Phase,220V) Air conditioner unit with R-32/R-410 refrigerant gas,MAKE: VOLTAS Model FAC 24 CZMM or equivalent in BLUESTAR/ VESTAR /MITSUBHISHI /DAIKIN /CRUISE/ CARRIER. (With copper condenser coil).
Providing and fixing of refrigerant copper pipes of following sizes (Suction & delivery) of split type AC i/c providing 2.5 sqmm 4 core electrical cable, insulation, extra gas charging and covering with PVC non adhessive tape over the insulation of refrigerant pipes and as per the direction of E-in-C
Refrigerant pipes of Sizes 5/8" & 3/8"
Supplying and fixing of 5KVA Voltage Stabilizer Suitable for 2 ton Air Conditioner as required of Make V Guard Model VND 500 (Voltage Range 150V-285V,15Amps.) or equivalent.
SITC of 04 Ton capacity Floor Standing, Tower type, 3 Phase,415V) Air conditioner unit with R-32/R-410 refrigerant gas,MAKE: VOLTAS Model FAC 48 CZMM, or equivalent in VESTAR/ CRUISE/BLUESTAR/CARRIER/ equivalent.(With copper condenser coil).
Providing and fixing of refrigerant copper pipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables, insulation, extra gas charging , cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering with PVC non adhessive tape over the insulation of refrigerant pipes and as per the direction of E-in-C
Refrigerant pipes of Sizes 3/4" & 1/2"
Fabrication of stand/Pedestal for keeping the indoor/out door unit of split type AC of various capacity made of suitable size of M S Angle and painting with one coat of red oxide and paint as required.
AKABEA INFRASTRUCTURES PRIVATE LIMITED
ROYAL ENGINEERING WORKS
TROPICAL REFRIGERATION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .