Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.9 LAccepted-AOC QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹27.8 L+₹93,615.28 (3.48%)Rejected-AOC | L-2 | Rejected-AOC Other than lowest bidder | |
| 3 | L-3₹28.7 L+₹1.8 L (6.59%)Rejected-AOC H NO 352 SECTOR 1 CHANNI HIMMAT JAMMU J K 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-3 | Rejected-AOC Other than lowest bidder | |
| 4 | L-4₹28.8 L+₹1.9 L (7.14%)Rejected-AOC 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-4 | Rejected-AOC Other than lowest bidder | |
| 5 | L-5₹29.2 L+₹2.3 L (8.43%)Rejected-AOC | L-5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
SPECIAL REPAIRS OF CGI SHEET ROOFING FALSE CEILING TILING REWIRING ETC OF BLDG NO. T-27 T-66 AND SECURITY WALL AT RATNUCHAK MIL STN UNDER GE KALUCHAK
2021_MES_489183_1
GE/KC/NIT-46/2021-22
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹77,000
Yes
4 Feb 2022
18 Nov 2021
29 Dec 2021
18 Nov 2021
21 Dec 2021
7 Dec 2021
18 Nov 2021 - 25 Nov 2021
Amount
Taking down chowkats or frames including shutters (without taking off shutters from the frame) n exc. 1.5 Sqm each including cutting holes for taking out hold fast or dismantled brickwork and making good disturbed portion in cement mortar 1:3 or PCC 1:2:4 type B-1, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each including cutting holes for taking out hold fast or dismantled brickwork and making good disturbed portion in cement mortar 1:3 or PCC 1:2:4 type B-1, complete all as specified & directed.
Taking down shutters of any description not exc. 1 Sqm each, complete all as specified & directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, complete all as specified & directed.
Brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
Taking up or down steel tubing and connections 25mm bore, complete all as specifed & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc. 10cm girth in brick/stone walls, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified & directed.
Factory made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long, complete all as specified & directed.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 100mm long, complete all as specified & directed.
Extruded aluminium alloy handle, fabricated type, anodised, 150mm long, complete all as specified & directed.
Butt hinges, medium weight, cold rolled, mild steel 100mm long, complete all as specified & directed.
2nd class hard wood (Sal/Hollock) plain, solid, straight chowkats/frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, with one or more rebates, complete all specified & directed.
Mild steel work as in bands, straps, supports or stays for rain water, vantilating pipes including bolts, if required, bolt hooks (stay), heavy for large gates; hook and pintle hinges; large hasp and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, necessary welding for fixing of butt hinges of any size/any number, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, necessary welding for fixing of butt hinges of any size/any number, complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
PCC 1:3:6 nominal mix, type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats and similar items, complete all as specified & directed.
30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified & directed.
35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, size of members of shutters as specified in clause 8.24 (b) of SSR Part-I, fitted to chowkat, complete all as specified & directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, 300mm long, complete all as specified & directed.
300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel and fixed to pressed steel frame / MS frame/ wooden chowkhats including necessary welding work etc where-ever required, complete all as specified & directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm, complete all as specifed & directed.
19/20mm dia mild steel chromium plated curtain rails of 1mm wall thickness in one length as per door/window with MS chromium plated bracket of suitable size, stops rollers etc, fixed in repairs, complete all as specified & directed.
18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber framed work as in cup board shutters, shelves etc., with 3mm thick teak wood beading/lipping, complete all as specified & directed.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified & directed.
150mm size hasp & staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws, complete all as specified.
Non skid ceramic coloured tiles, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Machine cut kota stone slab flooring, 18-20 mm thick as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 15mm screed layer in cement mortar 1:6, complete all as specified & directed.
Machine cut kota stone slab, 18-20 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Galvanized iron water tubing, medium grade, 25mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Angle valves, 15mm bore, fancy type, chromium plated, cast copper alloy with capstan head, screwed down, high pressure, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy with capstan head, screwed down, high pressure, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
Vitreous china, wash hand basin, white, flat back of size 550mmx450mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, 32mm dia HDPE waste pipe, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed.
PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified & directed.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore, fixed in repairs, complete all as specified & directed.
Brass chromium plated shower rose of 125mm size with or without swivel joints, fixed in repairs, complete all as specified & directed.
Chromium plated grating of 100mm size (square/round) cast copper alloy, made in two parts, fixed in floors/tiles with white/coloured cement, fixed in repairs, complete all as specified & directed.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls with clamps including dismantling of old unserviceable pipe, complete all as specified & directed.
PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls with clamps including dismantling of old unserviceable pipe, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified & directed.
75mm bore PVC (SWR) bends any radius, fixed in repairs, complete all as specified & directed.
PVC (SWR) vent cowl of size 110mm bore, fixed in repairs, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 110mm bore with oval access door, fixed in repairs, complete all as specified & directed.
PVC (SWR) junction single (Single T) equal or unequal, 75mm bore with oval access door, fixed in repairs, complete all as specified & directed.
Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Complete removal of the existing sunken treatment including roughening and preparation old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and applying the following treatment :- (a) 15 thick rendering on fair faces of brick work or cement surfaces in cement mortar 1:4 with using integral water proofing compound as per manufacturer instructions by weight of cement to sunken portion including wall of sunken portion with proper slope towards outside and finishing cement concrete or brick work surface even and smooth using extra cement, finishing concrete including walls of sunken portion with proper slope. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. Note : Ponding shall be done in sunken portion area by filling water which shall be kept there for 48 Hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
PCC 1:7:14, nominal mix, type F-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed.
BLANK
Galvanized iron tube as in spout pipe, medium grade, 40mm bore in short length of 450mm, cut to shape required including cutting holes in walls and making good in cement mortar 1:3, complete all as specified & directed.
Steel windows with bottom hung or top hung shutters with glazing bars, including hinges, steel side arms or peg stays and locking arrangements, complete all as specified & directed.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as in sunken floor using water proofing admixtures as per manufacturer's instructions, complete all as specified and as directed.
Soap dish, brass chromium plated, of size 100x60mm, fixed to walls with chromium plated screws, fixed in repairs, complete all as specified & directed.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs with chromium plated brass screws & wooden/plastic cleats, complete all as specified & directed.
Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in padding on roof, for levelling of roof slab, finished even and fair, complete all as specified & directed.
Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 2000 ltrs including making connections, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20 mm - 210 gms) and dismantling of old unserviceable water tank of any description, complete all as specified & directed.
Gun-metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed, fixed in repairs, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Taking down cement plaster and decayed concrete of any description, upto triple storey (11mtr) of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound or PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thick cement mortar 1:3, surface finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid seprately.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
15mm thick rendering in cement mortar 1:6 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
5mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
5mm thick rendering in cement mortar 1:4 over 10mm thick rendering in cement mortar 1:6 on brick or concrete surfaces using integral water proofing compound, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective items.
Supply only integral water proofing compound, complete all as specifed & directed.
75mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including forming and filling of joints 12mm wide with bituminous filler, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of ceiling by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
Complete removal of existing treatment from old decorated plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali-resistant priming paint over 2mm thick wall care putty, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of alkali-resistant priming, complete all as specified.
Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint of any tint over a coat of primer, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of cement base paint, complete all as specified & directed.
Preparation of new plastered surfaces of walls and applying two coats of exterior weather proof paint over a coat of primer, complete all as specified & directed.
Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scraping down smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of exterior weather proof paint, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
3mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Mild steel galvanised wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for (Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor finishes, complete all as specified & directed.
Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match, complete all as specified & directed.
75mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipe etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 200mm, complete all as specifed & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:2:4 (Nominal mix) type B-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 200mm, complete all as specified & directed.
Salt-glazed stoneware drain pipe, grade ‘A’ internal dia of pipe 200mm, laid in trenches and jointed, complete all as specified & directed.
Machine cut marble tile, 18-20 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified & directed.
Rolled mild steel work in roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290 grade-E-165, complete all as specified & directed.
Rolled mild steel work in main and cross beams, hip and jack rafters; purlins where connected to comman rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel framed work as in plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, n exc 30cm long, diametre of neck in exc 12mm but n exc 20mm, complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Non asbestos 4mm thick board (classic) of size 600x600mm laid on and included GI snap grid frame work (Grid size 605x605mm) for false ceiling with powder coated GI angle of size 25x25mm, main runner ‘T’ of size 25 x 40mm, secondary runner ‘T’ of size 25x30mm suspended with 3mm GI wire with butterfly clips for levelling, complete all as specified & directed. Note : 1. Quoted rates are inclusive for making holes, cutting chassis and making good to existing walls in cement mortar 1:3 or PCC 1:2:4 type B-1 as per existing finish all as directed at site. 2. All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
Preparation of new ceiling surfaces and applying two coats of oil emulsion distemper over a coat of alkali-resistant priming, complete all as specified.
RCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
RCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts, complete all as specified & directed.
Use & waste of form work to sides of pillars, posts, structs, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified & directed.
Dismantling of old rusted galvanised barbed wire fencing of any size, type & in any position, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Mild steel framed work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified & directed.
Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified & directed.
Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face, complete all as specified & directed.
Filling of crumple joint with 25mm thick polystyrene (thermocol), complete all as specified & directed.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 140 above but for one 3/5 pin 5 Amps socket outlet on same board.
All as per Srl item No. 140 here-in-before but for one 3/5 pin 5 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 4.0 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Inverter LED lamp 6500K, 900lm in white colour of 9 watt, base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified & directed.
Electronic fan regulator, 2 module, 120watt, (5 stepped type), 240 Volt for 1200/1400mm sweep AC ceiling fan, complete all as specified & directed.
Bell push flush type, one way 5 Amps single pole one way, complete all as specified & directed.
Electronic bell, musical type, AC, 240 volts, single pole, complete all as specified & directed.
LED tubelight fitting 1 x 20W inverter batten type fitting, 4 feet long, aluminium extruded housing, IP-20 rated, voltage 230 volts (operating range 140 volts to 270 volts), 50 Hz, system wattage 20 watt ±10%, system current not less than 102mA, power factor more than 0.95, system lumen efficacy 100 lm/watt CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% with all accessories pre-wired and making connection with three core PVC insulated overall sheathed flexiable copper cable of size 0.75sqmm from ceiling rose to light fitting, complete all as specified & directed.
Factory made epoxy powder coated distribution board vertical type, TPN, 4 ways with metal double door (IP-43 protection) confirming to IS : 8623, fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar, cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one MCCB 63/160/250 Amp 4P as incomer and MCBs SP/TP as outgoing, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
MCCB of capacity 63 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, ATM (Thermal magnetic release), adjustable overload 80-100%, adjustable short circuit 5-10 In, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting, complete all as specified & directed.
Supply, hanging and testing of 1200mm sweep, 230 volts, AC ceiling fans, BEE rated energy efficient ceiling fan conforming to IS:374-2019, having 3 blades alongwith copper wound stator (capacitor start) with minimum air delivery 210 cubic metre per minute, power consumption not more than 50 watt, top speed minimum 370 RPM or higher, speed control by 5 step electronic regulator including capacitor, down rod, canopy, making connection with three core flexiable copper cable of 1.50 Sqmm upto ceiling rose & taking down old unserviceable ceiling fan of any type/size from existing location and depositing in MES store, complete all as specified & directed.
Supply, installation and testing of water heater storage type (Geyser), single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, inner tank coating of ferro glass powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners - 04 Nos, hot & cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 2 Nos, non return valve 01 No and including necessary plumbing work, complete with integrated shock safe plug with all protection features as per OEM design and standard, complete all as spcified & directed.
Cutting & screwing of existing water supply line of 15mm bore for alterations or additions (or lengthening screw on pipe to form connector) including testing after completion, complete all as specified & directed. (each cut measured)
Stop valves, cast copper alloy, 15mm bore, screwed down, high pressure with capstan head, both ends screwed for iron pipe or for union etc., fixed in repairs, complete all as specifed & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion and removal of old unserviceable cable, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/ under floor/ under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Taking down carefully electric meter of any description by disconnecting electrically and refixing the same in old or new location, complete all as specified & directed.
Factory made epoxy powder coated distribution board, SPN, 16 ways with metal double door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
MCB, SPN, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' curve, complete all as specified & directed.
M/S Shiv Enterprises
M/S ARUN ANAND
NARESH KUMAR AND COMPANY
Pyramid constructions
GENESIS INDIA
MAMTA ENTERPRISES
S R CONSTRUCTIONS
KAMAL CONSTRUCTION
M/S Vishwakarma Builders
M/S TRIKUTA BUILDERS
M/S ANIL MAHAJAN
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .