| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC Awarded being L1. | |
| 2 | L2₹4.6 L+₹25,060 (5.74%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1. | |
| 3 | L3₹5.2 L+₹83,840 (19.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1. | |
| 4 | L4₹5.7 L+₹1.3 L (29.8%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L4 | Rejected-Finance OTHER THAN L1. |
Tender Value
₹9.0 L
EMD Value
₹17,940
Closing Date
9 Jul 2024, 6:00 pmClosed
AGE (I) CIF (K)
AGE (I) CIF (K) SHALATENG
REPAIR AND MAINTENANCE TO GEYSER, CEILING FANS, EXHAUST FANS, REFRIGERATOR, AC ETC, WORK IN CERTAIN ARMY BLDGS AND ALL RR UNITS AT SHARIFABAD MIL STN UNDER AGE (I) CIF (K).
2024_MES_658893_1
CA NO. AGE (I) CIF (K) - 09/2024-15
Open Tender
Civil Works
Item Rate
180 days
SHALATENG
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹17,940
Yes
17 Sept 2024
11 Jun 2024
11 Jul 2024
11 Jun 2024
9 Jul 2024
25 Jun 2024
Amount
Material and Labour for servicing and repair/replacement of defective parts of ceiling fan of 1200/1400 mm, Exhaust fan upto 300 mm sweep and wall fan of any type/capacity including greasing, oiling for smooth working , complete all as specified and as directed by the Engineer-in-Charge. Note :- Defective part will be measured and paid seperately under appropriate item of this BOQ.
Material and Labour for replacement of defective copper winding of ceiling fan of size 1200/1400 mm, Exhaust fan upto 300 mm sweep and wall fan of any type/capacity with existing size of super enamelled copper wire including varnishing and heating for smooth working complete with testing for 24 hours, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement Fan Condenser 2.5/4.0 MFD , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement Ball Bearing of any type and size, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of fan hook clamp with split pin of existing size, complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for repair of Geyser of capacity 25/50 litres including disconnecting of all electric/water line connection from existing point and taking out for repairs at site workshop, replacement of defective parts of geyser and testing after completion of repair to satisfication of Engineer-in-Charge and refixing/remounting on wall of geyser with S&F new 4 x fastener, nuts, bolts and washer of suitable size, complete all as specified and as directed by Engineer-in-Charge. Note :- Defective parts will be measured and paid seperately under appropriate item of this BOQ.
Supply and replacement of Heating Element of any type/size suitable for geyser of any capacity, of 1500 watt/2000 watt, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Geyser assembly of any type and size suitable for 25/50 litres capacity, complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of thermostate of geyser of any type and size suitable for 25/50 litres capacity, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of MS heat resistant heavy duty inner tank of geyser of capacity 25/50 litres, complete all as specified and directed by Engineer-in-Charge.
Supply and replacement of lead wool for geyser of 25/50 litres capacity, complete all as specified as directed by the Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches,ceiling rose ,pendents ,regulators,socket,lamp holders brackets,bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and also making good distrubed surfaces of wall,floors etc, complete all as specified and directed by the Engineer-in-Charge.
Point wiring with 2.5 sqmm copper conductor (Multistranded) PVC insulated and unsheatheted FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts, 2.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continious earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good distrubed surface of wall ,covered with 3 mm thick plastic laminated for mounting of switches, socket, fan regulators etc., complete all as specified and directed by the Engineer-in-Charge .
S&F Swithch socket combination 5 in 1, 5 & 15 Amp flush type complete all as specified and directed.
S&F plug top 3 pin 15 Amp 240 volt ISI marked complete all as specified and directed by Engr-In-Charge.
Dismantling and lowering to ground for repair, inspecting defective of Window and split type AC of capacity 1.5 and 2 Ton and re-installing the same after repair and descaling of condenser and servicing complete, testing to the complete satisfaction of the Engineer-in-Charge.
Taking out the existing burntout compressure and supply and replacement of compressor sealed unit suitable for ACs 1.5 Ton Capacity flushing , vaccumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including including replacement of strainer, complete all as specified and as directed by the Engineer-in-Charge. Make- Kirloskar/ Tecumshah
Supply and replacement of compressor sealed unit suitable for ACs 2 Ton Capacity flushing , vaccumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition including including replacement of copper strainer, complete all as specified and as directed by the Engineer-in-Charge. Make- Kirloskar/ Tecumshah
Material and labour for charging of gas in window type AC of capacity 1.5 Ton after flushing,vaccumising and hydration as per laid down standard practice including replacement of copper strainer, complete all as specified as directed by the Engineer-in-Charge.
Material and labour for charging of gas in split type AC of capacity 2 Ton after flushing,vaccumising and hydration as per laid down standard practice including replacement of copper strainer complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of blower motor of size 1/10 HP for Air Conditioner of capacity 1.5 Ton as per existing model of approved make, complete all as specified as directed by the Engineer-in-Charge. Make: NDO AIR MASTER/FRAC MASTER
Supply and replacement of running capacitor 36 mfd, complete all as specified and as directed by the Engineer-in-Charge. Make: TIBCON/SIEMENS
Supply and replacement of running capacitor 45 mfd, complete all as specified and as directed by the Engineer-in-Charge. Make:TIBCON/SIEMENS.
Supply and replacement of starting capacitor of size 100-120MFD for Air Conditioner upto 2 Ton Capacity, complete all as specified and as directed by the Engineer-in-Charge. Make:TIBCON/SIEMENS.
Supply and replacement of starting capacitor of size 80-100 mfd., complete all as specified and as directed by the Engineer-in-Charge. Make:TIBCON/SIEMENS,
Supply and replacement of box type relay type Model Sr-1622 for Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by department, complete all as specified and as directed by the Engineer-in-Charge. Make:SRIRAM/RENUTROL
Supply and replacement of air filter of window/ split type AC suitable AC 1.5/2 Ton Capacity, complete all as specified and as directed by the Engineer-in-Charge. Male: BLUESTAR/VOLTAS/FEEDER LOYD
Supply and replacement of thermostatic switch of ACs of capacity 1.5 to 2 Ton, complete all as specified and as directed by the Engineer-in-Charge. Make:- Make :- Renutrol/Indfoss or equivalent as approved by AGE(I).
Supply and replacement of PCB assembly for window type Acs of capacity 1.5 to 2.0 ton with remote control, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of PCB assembly for split type Acs of capacity 1.5 to 2.0 ton with remote control., complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of fan blade of ACs of capacity 1.5 to 2.0 ton as per existing, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing sheet metal enclousers, single pole and neutral with a two pin and earth plug and socketed complete with one single pole MCB of capacity 20 Amp, 240 volts., complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting electrical connection and taken out to inspect the defect of refrigerator of capacity 165 to 310 Litres including cleaning greasing, oiling of required parts etc and re-installing the same after repair and testing the unit, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of compressor sealed unit for refrigerator of size 165 to 220 litres capicity with copper strainer and including , supplying and charging of gas with necessary welding/soldering for leak proof as required, including commissioning and testing, complete all as specified as directed by the Engineer-in-Charge. Make- Kirloskar/Tecumesh
Description all as per serial item No 34 here-in-before, but of capacity 280/320 litres , complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of Freezer with door frame of refrigerator of capacity 165 to 220 litres, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of Freezer with door frame of refrigerator of capacity 286 to 310 litres, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of starting box type relay 1/6 HP for refrigerator, complete all as specified as directed by the Engineer-in-Charge.
Supply and replacement of Over load protector 1/6 HP for refrigerator, complete all as specified as directed by the Engineer-in-Charge.
Supply and charging refrigerant gas in the refrigerator including satisfactory leak test and vaccum test of capacity 165 to 220 litres including replacement of copper strainer and necessary welding work, complete all as specified as directed by the Engineer-in-Charge.
Description all as per serial item No 40 here-in-before, but of capacity 280/320 litres , complete all as specified and as directed by the Engineer-in-Charge. Make-Kirloskar/Tecumesh
Description all as per serial item No 40 here-in-before, but deep freezer of capacity 280/230 litres , complete all as specified and as directed by the Engineer-in-Charge. Make:- Kirloskar/Tecumeshvoltas/Godrej
Supply and replacement of thermostat switch for refrigerator of any size, complete all as specified and as directed by the Engineer-in-Charge. Make:- IND FOSS/RENUTROL/HITECH.
Supply and replacemet of door gaskets of refrigerator 165 to 310 litres, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of fan motor of freezer of refrigerator 286 to 310 litres, complete all as specified and as directed by the Engineer-in-Charge.
Disconnecting and complete opening of voltage stablizer of capacity upto 10KVA and removing the burnt out unserviceable parts and cleaning, complete all as specified and as directed by the Engineer-in-Charge.
Rewinding with copper enamelled wire as per existing gauge of transformer assembly of voltage stabilizers for following capacity, complete all as specified and as directed by the Engineer-in-Charge :-
up to 0.5 KVA
Supply and replacement of boost/buck relay of voltage stablizers of following capacity, complete all as specified and as directed by the Engineer-in-Charge:-
upto 0.5 KVA
Supply and replacement of time delat relay PCB card for 0.5 to 10KVA, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of 909V sensing transformer capacity 500ma, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of 909V sensing transformer capacity 1 Amp, complete all as specified and as directed by the Engineer-in-Charge.
Supply and replacement of toggle switch 2way 10Amp, complete all as specified and as directed by the Engineer-in-Charge.
Note :- An amount of Rs. 32,950.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S Ghulam Mohammad Shalla
YATTOO ENTERPRISES
M/S SHIMAR STAR GLACIER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .