| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-Finance | L1 | Accepted-Finance Complied as per NIT | |
| 2 | L2₹6.5 L+₹52,945 (8.84%)Accepted-Finance | L2 | Accepted-Finance Complied as per NIT | |
| 3 | L3₹7.3 L+₹1.3 L (21.1%)Accepted-Finance | L3 | Accepted-Finance Complied as per NIT | |
| 4 | L4₹7.4 L+₹1.4 L (23.7%)Accepted-Finance 388 SRI BENAKA 1ST PHASE 4TH STAGE VIJAYANAGAR MYSORE KARNATAKA 570017 | MYSURU | KARNATAKA | 570017 | L4 | Accepted-Finance Complied as per NIT | |
| 5 | L5₹9.0 L+₹3.0 L (50.7%)Accepted-Finance | L5 | Accepted-Finance Complied as per NIT |
| Sl No | Description | Qty | Unit | SUNDAR ASSOCIATES L4 | AKEY ELECTRO TECHNIQUES L3 | SRS ELECTRICALS L5 | S AND S ELECTRICALS L1 | AKSHAYA ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, Installation, Testing & Successful Commissioning of 20 Watts, 4 Feet LED Batten Light (light colour as per choice of Engineer Incharge), ready to use, complete with internal wiring, required length of any standard make rated 3 core copper wire, with suitable hardwares etc., to fix on wall / ceiling as per site requirement; to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting to be terminated to a ceiling rose for all. Make for All : Please refer Special Electrical Conditions under Tender Document File. | 20 | Each | 500 ₹10,000 | 350 ₹7,000 Lowest | 750 ₹15,000 | 600 ₹12,000 | 700 ₹14,000 |
| 2.00 | Supplying, Installation, Testing & Successful Commissioning of 36 Watts, 4 Feet LED Batten Light (light colour as per choice of Engineer Incharge), ready to use, complete with internal wiring, required length of any standard make rated 3 core copper wire, with suitable hardwares etc., to fix on wall / ceiling as per site requirement; to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting to be terminated to a ceiling rose for all. Make for All : Same as Item No:1 | 34 | Each | 850 ₹28,900 | 750 ₹25,500 Lowest | 1,250 ₹42,500 | 1,200 ₹40,800 | 900 ₹30,600 |
| 3.00 | Supplying, Installation, Testing & Successful Commissioning of IP65 50 Watts LED Focus Light (light colour as per choice of Engineer Incharge) complete with internal wiring, 1 metre length of any standard make rated 3 core copper wire etc., ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. he end wire from the fitting to be terminated to a ceiling rose for all. Make for All : Same as Item No:1 | 5 | Each | 1,700 ₹8,500 | 2,700 ₹13,500 | 3,000 ₹15,000 | 2,500 ₹12,500 | 1,600 ₹8,000 Lowest |
| 4.00 | Supplying, Installation, Testing & Successful Commissioning of 16 Modular PVC Box along with Modular Base, Cover Plate etc., in recess / wall using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 2 Nos; b) 3 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 20 Amps, 2 Pole, "C" Curve, 10kA, 230V Mini MCB - 1 No. Internal wiring for 5 Amps Switch & Socket with 2.5 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and Green Colour 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire for Earthing Loop and terminate all the wires using suitable size Copper Lugs etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File. | 33 | Set | 2,700 ₹89,100 | 2,800 ₹92,400 | 2,200 ₹72,600 Lowest | 2,750 ₹90,750 | 2,600 ₹85,800 |
| 5.00 | Supply, Installation, Testing and Successful Commissioning of MCB Distribution Box of size 8" (W) x 8" (H) x 8" (D) made out 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of primer & 2 coats of Siemens Gray colour paint, suitable for 230V / 440V, AC to fix on surface. The DB shall consist of Din Rail to fix 1 x 63Amps 2 Pole RCCB having a sensitivity current 30mA, 1 x 32 Amps 2 Pole MCB, "C" Curve, 10kA Breaking Capacity, 2 nos of blank plates and respective colour LED Indicator for the output tapped from R / Y / B Phase. One of the Phase Line of Item No:14, (in alternative) shall be given as Input for both RCCB and MCB as Input with 10.0 sq.mm and 4.0 sq.mm single core copper wires (Red & Black), duly terminated with copper lugs respectively. The incoming earth wire from the mains should be terminated to the earth bolt / bar in the box with lugs. Make: Please refer Special Electrical Conditions under Tender Document File. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker. | 10 | Each | 7,400 ₹74,000 | 7,800 ₹78,000 | 25,000 ₹2,50,000 | 5,500 ₹55,000 Lowest | 6,500 ₹65,000 |
| 6.00 | Supply & Fixing of 1" (25mm (H) x 20mm (D)) Electrical Grade Box Type Casing-Capping on Wall / Ceiling with One and Half Inch POP Screws and Wooden Gatta and to fix Tee / Elbow / Junction Boxes etc., as required. Colour: White / Ivory. 1 Length = 3 Metres. Make: Please refer Special Electrical Conditions under Tender Document File. | 30 | Length | 350 ₹10,500 | 95 ₹2,850 Lowest | 150 ₹4,500 | 200 ₹6,000 | 100 ₹3,000 |
| 7.00 | Fixing and Servicing of Institute provided DB Panel / MCCB by removing the existing old TPN / DPIC etc., and to give connections to all the existing output lines in the replaced Panel. | 1 | Job | 5,000 ₹5,000 | 2,000 ₹2,000 Lowest | 10,000 ₹10,000 | 10,000 ₹10,000 | 2,500 ₹2,500 |
| 8.00 | Labour charges for digging 8 feet of depth below ground level, including hard soil, rocks, cement surface etc.,if any encountered, fixing the Item No:18, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:18 as required, already estimated under S.No.18). | 4 | Each | 5,200 ₹20,800 | 6,000 ₹24,000 | 2,500 ₹10,000 Lowest | 4,000 ₹16,000 | 4,000 ₹16,000 |
| 9.00 | Dismantling & taking down all Old Electrical Wirings / Lights / Switch Boards and respective related wirings, hardwares etc., after carefully disconnecting the incoming electrical input and insulating the same, depositing all the old materials in an organised manner to the Auction / Electrical Section Store Yard or as per the advise of the Electrical Officer In-Charge of the Project without any damage. Note: While dismantling, Telephone / Internet Network Lines etc., should not be disturbed and proper care should be taken in all the 12 rooms. | 1 | Job | 12,000 ₹12,000 | 25,000 ₹25,000 | 30,000 ₹30,000 | 12,000 ₹12,000 | 6,000 ₹6,000 Lowest |
| 10.00 | Group A wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make: Same as Item No: 4 | 40 | Point | 850 ₹34,000 Lowest | 925 ₹37,000 | 1,350 ₹54,000 | 900 ₹36,000 | 1,500 ₹60,000 |
Tender Value
₹6.0 L
EMD Value
₹12,000
Closing Date
5 Nov 2025, 5:00 pmClosed
The Director
CSIR-CFTRI, Cheluvamba Mansion, Mysuru
Replacing and Rewiring of Short Circuited Aluminium Wiring in 12 rooms (West Corridor) in Animal House Facility at DoB Department at CSIR-CFTRI, Mysuru
2025_CSIR_253472_1
E/EW/005/1102/2025-26
Open Tender
Electrical Works
Item Rate
40 days
at CSIR-CFTRI Campus
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹12,000
25 Nov 2025
27 Oct 2025
7 Nov 2025
27 Oct 2025
5 Nov 2025
27 Oct 2025
27 Oct 2025 - 4 Nov 2025
Amount
Supplying, Installation, Testing & Successful Commissioning of 20 Watts, 4 Feet LED Batten Light (light colour as per choice of Engineer Incharge), ready to use, complete with internal wiring, required length of any standard make rated 3 core copper wire, with suitable hardwares etc., to fix on wall / ceiling as per site requirement; to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting to be terminated to a ceiling rose for all. Make for All : Please refer Special Electrical Conditions under Tender Document File.
Supplying, Installation, Testing & Successful Commissioning of 36 Watts, 4 Feet LED Batten Light (light colour as per choice of Engineer Incharge), ready to use, complete with internal wiring, required length of any standard make rated 3 core copper wire, with suitable hardwares etc., to fix on wall / ceiling as per site requirement; to work with 230V Single Phase, 50Hz AC Supply. The end wire from the fitting to be terminated to a ceiling rose for all. Make for All : Same as Item No:1
Supplying, Installation, Testing & Successful Commissioning of IP65 50 Watts LED Focus Light (light colour as per choice of Engineer Incharge) complete with internal wiring, 1 metre length of any standard make rated 3 core copper wire etc., ready to use suitable to fix on wall / ceiling and to work with 230V Single Phase, 50Hz AC Supply. he end wire from the fitting to be terminated to a ceiling rose for all. Make for All : Same as Item No:1
Supplying, Installation, Testing & Successful Commissioning of 16 Modular PVC Box along with Modular Base, Cover Plate etc., in recess / wall using suitable hardwares etc., as per directions of Engineer In-Charge and consisting of following Modular items a) 5/6 Amp Switch - 2 Nos; b) 3 Pin 5/6 Amp Socket Outlet - 2 Nos; c) 15/16 Amp Switch - 2 Nos; d) 6 pin 15/16 Amp Socket Outlet - 2 Nos and e) 20 Amps, 2 Pole, "C" Curve, 10kA, 230V Mini MCB - 1 No. Internal wiring for 5 Amps Switch & Socket with 2.5 sq.mm FRLS Multistrand, Single Core Copper Wire; for 15 Amps Switch & Socket with 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire. Red and Black Colour for Phase and Neutral and Green Colour 4.0 sq.mm FRLS Multistrand, Single Core Copper Wire for Earthing Loop and terminate all the wires using suitable size Copper Lugs etc., as required. Make: Please refer Special Electrical Conditions under Tender Document File.
Supply, Installation, Testing and Successful Commissioning of MCB Distribution Box of size 8" (W) x 8" (H) x 8" (D) made out 1.6mm thick CRCA sheet steel enclosure, painted with 2 coats of primer & 2 coats of Siemens Gray colour paint, suitable for 230V / 440V, AC to fix on surface. The DB shall consist of Din Rail to fix 1 x 63Amps 2 Pole RCCB having a sensitivity current 30mA, 1 x 32 Amps 2 Pole MCB, "C" Curve, 10kA Breaking Capacity, 2 nos of blank plates and respective colour LED Indicator for the output tapped from R / Y / B Phase. One of the Phase Line of Item No:14, (in alternative) shall be given as Input for both RCCB and MCB as Input with 10.0 sq.mm and 4.0 sq.mm single core copper wires (Red & Black), duly terminated with copper lugs respectively. The incoming earth wire from the mains should be terminated to the earth bolt / bar in the box with lugs. Make: Please refer Special Electrical Conditions under Tender Document File. Note: Labelling to be done for Input & Output Control in Paint / Acrylic Sticker.
Supply & Fixing of 1" (25mm (H) x 20mm (D)) Electrical Grade Box Type Casing-Capping on Wall / Ceiling with One and Half Inch POP Screws and Wooden Gatta and to fix Tee / Elbow / Junction Boxes etc., as required. Colour: White / Ivory. 1 Length = 3 Metres. Make: Please refer Special Electrical Conditions under Tender Document File.
Fixing and Servicing of Institute provided DB Panel / MCCB by removing the existing old TPN / DPIC etc., and to give connections to all the existing output lines in the replaced Panel.
Labour charges for digging 8 feet of depth below ground level, including hard soil, rocks, cement surface etc.,if any encountered, fixing the Item No:18, refilling of soil etc., as required. (along with charcoal / coke and salt from S.No:18 as required, already estimated under S.No.18).
Dismantling & taking down all Old Electrical Wirings / Lights / Switch Boards and respective related wirings, hardwares etc., after carefully disconnecting the incoming electrical input and insulating the same, depositing all the old materials in an organised manner to the Auction / Electrical Section Store Yard or as per the advise of the Electrical Officer In-Charge of the Project without any damage. Note: While dismantling, Telephone / Internet Network Lines etc., should not be disturbed and proper care should be taken in all the 12 rooms.
Group A wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make: Same as Item No: 4
Group B wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc., as required. Make for all: Same as Item No: 4
Wiring for circuit / submain wiring alongwith earthwire with 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 4. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earthwire with 2 x 6.0 + 1 x 6.0 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 4. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Wiring for circuit / submain wiring alongwith earthwire with 4 x 10.0 + 2 x 6.0 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. Make for all: Same as Item No: 4. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Supplying & drawing 2 x 1.5 sq.mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. Make for all: Same as Item No: 4. Note: All start, loop & end point of the wires are to be terminated with "Cu" Lugs of suitable type and size and individual pipes for wiring.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc., as required. Make: Same as Item No: 4.
Supplying and fixing 20A, 240V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Make: Please refer Special Electrical Conditions under Tender Document File.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. Note: Masonry enclosure size is 1.5 Feet x 1.5 Feet x 1.5 Feet. As per IS 3043, charcoal / coke and salt should be refilled with 50 Kg each per earthpit. The copper plate to be connected with a suitable size copper flat using SS / Bronze nut, bolts and washers until the funnel.
Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15mm G.I. pipefrom earth electrode including connection with copper thimble excavation and refilling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerence as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required. Fan & 2 Module Step Regulator Make: Please refer Special Electrical Conditions under Tender Document File.
Demolishing cement concrete Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-incharge.
Cement Concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tampling complete.
AKSHAYA ASSOCIATES (BID ID -923134)
AKEY ELECTRO TECHNIQUES (BID ID -923579)
SUNDAR ASSOCIATES (BID ID -922716)
SRS ELECTRICALS (BID ID -923637)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
TENEW005202526.pdf
Tender Documents • 1.91 MB
BOQ_291494.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .