Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-Finance AT DANGALPARA SURJ BIRBHUM PIN 731191 | SURI | BIRBHUM | WEST BENGAL | 731191 | L1 | Accepted-Finance Quoting Lowest rate | |
| 2 | L2₹42.0 L+₹2,036 (0.05%)Rejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance Quoting High Rate | |
| 3 | L3₹42.0 L+₹5,721 (0.14%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L3 | Rejected-Finance Quoting High Rate | |
| 4 | Rejected-Technical 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | - | Rejected-Technical Insufficient Documents |
| Sl No | Description | Qty | Unit | Swarnendu Sarkar L2 | UJJWAL MUKHERJEE L3 | BABA ELECTRIC L1 |
|---|---|---|---|---|---|---|
| 1.00 | SUB-HEAD 1-SITC OF FIRE ALARM PANEL. Supply , Installation , Testing and Commissioning of minimum 6 loop Microprocessor based Multi-loop, addressable fire alarm panel , Fully 7-inch Touch Screen 800 x 480 pixel display, with peer to peer networking of 250 FAP in single node, each panel should act as master panel, single loop with minimum 240 addressable points (Any combination) per loop, panel with built in battery charger that can support backup upto 24hours idle condition and 30 minutes during alarm condition, Programing via PC or panel keypad and touch screen, panel with integral thermal printer, option to interface to BMS with optional interface of LON Works, BACnet & MODBus, 96 Zonal LEDs on board, capacity to have upto 250 logic zones, 4 NAC circuits, 3 programmable relays, dedicated Alarm relay, Integral short circuit, History records of 100,000 events, should have PAS (Positive Alarm Sequence) , should have Optional Redundancy CPU, total load Max.2.5A/24VDC. Should have Remote diagnosis via Ethernet, Email notification, Real time detector compensation level report. As per NBC guidelines- Networkable Fire alarm control panel shall be able to accommodate below given detectors & devices and shall have 20% spare capacity to accommodate future expansions of addressable points. Comply EN-54- LPCB approved. (Approved Make : GST/ Johnson Controls/ Edward other equivalent make as approved by E.I.C) ) | 1 | Item | 3,08,540 ₹3,08,540 | 3,09,880 ₹3,09,880 | 3,07,620 ₹3,07,620 Lowest |
| 2.00 | Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable and network connected Repeater panel of EN-54 standard LPCB approved, should have all the controls and monitoring as on the main fire alarm panel, functioning as a controller, shall allow remote command in the system reset, trouble and alarm silence and manual alarm. It shall be programmable to display information for the entire system i.e. all panels in the network, having minimum 80 characters LCD display (display system status) With CAN networking. The system text displays shall include: Alarm missing point trouble; system test, service, local system test, extra custom test by polling circuit and address. The repeater panel should annunciate alarm and trouble conditions in the occasion of signal actuation. (Approved Make : GST/ Johnson Controls/ Edward) | 2 | Nos | 1,21,360 ₹2,42,720 | 1,22,560 ₹2,45,120 | 1,21,150 ₹2,42,300 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning of Microprocessor controlled. IP Addressable Multi-sensor detector of EN-54 standard LPCB approved with inbuilt optical smoke Sensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptable Provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in LED indicator. Thedetector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector and the protection catagory of IP40. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : GST/ Johnson Controls/ Edward) | 388 | Nos | 3,153 ₹12,23,364 Lowest | 3,154 ₹12,23,752 | 3,153 ₹12,23,364 Lowest |
| 4.00 | Supply, Installation, Testing & Commissioning of Microprocessor controlled IP Addressable Heat detector of EN-54 standard LPCB approved with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 60 deg. to 80 deg. having high level of imunity to electrromagnetic influences and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in LED indicator with 360 degree viewing angle and the protection catagory of IP40. (Approved Make : GST/ Johnson Controls/ Edward) | 15 | Nos | 2,321 ₹34,815 Lowest | 2,321 ₹34,815 Lowest | 2,321 ₹34,815 Lowest |
| 5.00 | Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point of EN-54 standard LPCB approved with necessary accessories for fitting, JB etc. (Approved Make: GST/ Johnson Controls/ Edward) | 32 | Nos | 3,510 ₹1,12,320 Lowest | 3,510 ₹1,12,320 Lowest | 3,510 ₹1,12,320 Lowest |
| 6.00 | Supply, Installation, Testing & Commissioning of Loop Isolator Modules of EN-54 standard LPCB approved. Loop Isolator can isolate the shorted circuit from the whole system to ensure normal operation of other devices and locate the devices in fault. After the short
circuit fault is cleared, those devices will be re-introduced into the system with degree of protection IP 30. (Approved Make : GST/ Johnson controls/Edward) | 32 | Nos | 2,440 ₹78,080 Lowest | 2,440 ₹78,080 Lowest | 2,440 ₹78,080 Lowest |
| 7.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter (sound output of minimum 80 db ) cum strobe (strength of iight 10 cd) of EN-54 standard LPCB approved with necessary accessories for fitting, JB etc. (Approved Make: GST/ Johnson Controls/ Edward) | 16 | Nos | 6,771 ₹1,08,336 Lowest | 6,771 ₹1,08,336 Lowest | 6,771 ₹1,08,336 Lowest |
| 8.00 | Supplying, Installing, Testing & Commissioning of LED technology, High efficiency, Double Sided Exit Signage cum Emergency light with Function Use either as an emergency luminaire or exit sign, Testing system Stand Alone, Housing Polycarbonate, Glow wire test : 850°C, RAL9003, Type of mounting Surface: Recessed base for ceiling, double sided cone diffuser, plexi plate diffuser, set of 3 exit legends (L, R, D), Degree of protection IP65, Operation Mode Non Maintained or Maintained & Non Maintained mode selectable, Connection voltage 230V -/+ 5% [220V-240V] 50-60Hz, Permissible ambient: temperature +5°C to +40°C, Battery: Ni-Cd, Duration 3 hours, Viewing distance 30m, Insulation class II, Dimensions for 30 m viewing distance version: 371 x 170 x 62.(Approved Make: GST/ Johnson Controls/ Edward or other equivalent make as approved by E.I.C) | 12 | Nos | 3,868 ₹46,416 Lowest | 3,868 ₹46,416 Lowest | 3,868 ₹46,416 Lowest |
| 9.00 | Supply & Laying of 1.1KV grade 2 Core 1.5 sq.mm FRLSH shielded copper Conductor stranded cables in red/black color (Make: Finolex/ Technoflex/ MEM/ KEI) for Looping.in PVC rigid FR conduit (Precision make of Red colour or as approved by EIC) on wall with saddles including Supply & Fixing of 20 mm PVC rigid FR conduit complete with all accessories.
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of --
(i) National Fire Protection Association (NFPA) standards,
(ii) IS 2189
(iii) NFPA 7O National Electric Code,
(iv) NFPA 72 National Fire Alarm & Signaling Code
(v) Local Statutory Regulations ,
(vi) Manufacturer Recommendation
vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. viii) The agency must arranged a mock drill for the fire detection alarm system at Sainthia State General Hospital. (ix)The agency must be Maintenant atlist Two years of DLP | 3,850 | Mtrs | 208 ₹8,00,800 Lowest | 208 ₹8,00,800 Lowest | 208 ₹8,00,800 Lowest |
| 10.00 | SUB-HEAD 2--SUPPLY & LAYING of fire Pump cable. Supply & delivary of 1.1KV grade 4 core 240 sq.mm. PVC/A AL. cable to be laid through masonary / U.G trench as per G.S. (from LT panel room to Fire pump room ) - [Make- Gloster/ Havells / Polycab/ KEI / As per choice of EIC] | 390 | Mtrs | 2,763 ₹10,77,570 Lowest | 2,763 ₹10,77,570 Lowest | 2,763 ₹10,77,570 Lowest |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
23 Feb 2026, 11:00 amClosed
Sr.Superintending Engineer
Office of the Sr. Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Supply , Installation , Testing and Commissioning SITC of Fire Detection and Alarming system at Sainthia SGH, Sainthia, Birbhum RN 24001423, Project ID HF252646146S000.
2026_WBPWD_1006105_1
WBPWD/SSEWEC /BRED /NIQ-79 /2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Birbhum
Please refer Tender documents.
5 documents required · 5 mandatory
₹84,000
Office of the Sr. Superintending Engineer, Western
27 Apr 2026
13 Feb 2026
25 Feb 2026
13 Feb 2026
23 Feb 2026
17 Feb 2026
13 Feb 2026 - 16 Feb 2026
16 Feb 2026
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 17.49 MB
new2911.pdf
Tender Documents • 0.51 MB
BOQ_2468093.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .