| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-Finance | L1 | Accepted-Finance BEING LOWEST | |
| 2 | L2₹43.0 L+₹2.9 L (7.31%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹43.3 L+₹3.3 L (8.18%)Rejected-Finance SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹45.8 L+₹5.7 L (14.3%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹47.4 L+₹7.4 L (18.4%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | SHAH BUILDERS L2 | George Electricals L7 | KSP ENTERPRISES L9 | M/s Harshal Traders L5 | Sunhari Electricals L8 | A.B.CONSTRUCTION L10 | D H L ENTERPRISES L4 | PROLINK COMPUTERS L3 | SHRI PLACEMENT AND CONSULTANCY SERVICES L1 | K K ENGINEERING SERVICES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out cable of any dia/sq mm in trench/wall all as directed by Engr-in-Charge | 535 | RM | 27 ₹14,445 | 12 ₹6,420 | 15 ₹8,025 | 12 ₹6,420 | 20 ₹10,700 | 10 ₹5,350 | 8 ₹4,280 Lowest | 9 ₹4,815 | 15 ₹8,025 | 15 ₹8,025 |
| 2.00Supply laying, joint testing & commissioning LT under ground cable 1100 volts grade XLPE insulated armoured with galvanised round steel wire or steel strep, electric power cable heavy duty, with multi stranded aluminum conductor, laid in trenches, ducts fixed on wall/poles with proper size saddles and clamp laid under road/path/drain/culverts or enclosed in GI pipe/fix complete all as specified, for following size : | |||||||||||||
| 2.01 | (a) 70 Sq mm x 3.5 core | 150 | RM | 572 ₹85,800 | 550 ₹82,500 | 555 ₹83,250 | 600 ₹90,000 | 504 ₹75,600 | 750 ₹1,12,500 | 240 ₹36,000 Lowest | 600 ₹90,000 | 540 ₹81,000 | 540 ₹81,000 |
| 2.02 | (b) 16 Sq mm x 4 core | 385 | RM | 230 ₹88,550 | 450 ₹1,73,250 | 455 ₹1,75,175 | 210 ₹80,850 | 186 ₹71,610 Lowest | 550 ₹2,11,750 | 480 ₹1,84,800 | 300 ₹1,15,500 | 225 ₹86,625 | 240 ₹92,400 |
| 2.03 | (c) 6 Sq mm x 2 core | 250 | RM | 135 ₹33,750 | 390 ₹97,500 | 389 ₹97,250 | 210 ₹52,500 | 97 ₹24,250 Lowest | 350 ₹87,500 | 180 ₹45,000 | 210 ₹52,500 | 150 ₹37,500 | 180 ₹45,000 |
| 2.04 | (d) 10 Sq mm x 4 core | 250 | RM | 230 ₹57,500 | 360 ₹90,000 | 359 ₹89,750 | 240 ₹60,000 | 175 ₹43,750 Lowest | 300 ₹75,000 | 240 ₹60,000 | 252 ₹63,000 | 210 ₹52,500 | 210 ₹52,500 |
| 3.00 | Taking down old Lt Panel Supply install, test and commissioning Powder coated LT Panel (CPRA Approved) Powder coated, free standing type compartmentalized in construction center openable double door type with canopy factory fabricated from makes as specified and made out of 3 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars having rating cap of 400 A. The TPN copper bus bars bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The Out Going MCCB of rating greater than 125 amps shall have copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides. | 1 | Each | 1,62,000 ₹1,62,000 | 1,27,000 ₹1,27,000 | 1,28,000 ₹1,28,000 | 1,42,000 ₹1,42,000 | 40,000 ₹40,000 Lowest | 1,35,000 ₹1,35,000 | 91,000 ₹91,000 | 1,50,000 ₹1,50,000 | 1,65,000 ₹1,65,000 | 1,50,000 ₹1,50,000 |
| 3.01The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, & Reconnecting the cables to new panels, replacing of cable glands, lungs and including PCC foundation, excevation, foundation bolts. The Panel shall comprise of following switchgears & acessories (a) S&F MCCB FP 250 Amp 25 KA -02 Nos (For Main incoming-01 No & For incoming DG Set -01No ) (b) S&F MCCB TP 100 Amps 16 KA -04 Nos (d) S&F MCCB TP 63 Amps, 16 KA -03 Nos (e) Change over switch 250 A, 04 Pole -01 Nos (e) S&F Indicating Lamp RYB (LED) Type-01 Set (g) Digital 3 Phase Amp Meter & Voltmeter with selector switch -01 Set (h) Digital Street light timer -01 Nos (j) Auto Manual Selector switch -01 No (k) MCB TPN 40 Amps -03 Nos (l) MCB SPN 40 Amp -02 Nos Note : Layout diagram of panel shall be submitted by the Contractor for the approval of GE. | |||||||||||||
| 4.00 | M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground vertically at a depth not less than 2.25m below normal ground level with top level of earth plate at depth not less than 1.5m below normal ground level surrounded form all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 25mmx4mm by means of bolts, nuts, check nuts and washers of galvanized iron and protected by GI pipe light grade 50mm bore connected to main switch board or main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, 80mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation; and earth work, disposal of surplus soil to a distance not exceeding 50m all as specified and as shown in Electrical Plate No 3 of MES Schedule Part-I. | 2 | Each | 6,499 ₹12,998 | 7,000 ₹14,000 | 7,200 ₹14,400 | 5,410 ₹10,820 | 5,000 ₹10,000 Lowest | 7,500 ₹15,000 | 5,500 ₹11,000 | 6,300 ₹12,600 | 6,000 ₹12,000 | 6,000 ₹12,000 |
| 5.00 | Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m deep for laying of cable etc and getting out soft/loose soil complete all as specified and directed. | 142.6 | Cum | 230 ₹32,798 | 320 ₹45,632 | 310 ₹44,206 | 235 ₹33,511 | 150 ₹21,390 Lowest | 330 ₹47,058 | 280 ₹39,928 | 240 ₹34,224 | 180 ₹25,668 | 250 ₹35,650 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
9 Oct 2025, 6:00 pmClosed
Garrison Engineer
GE AF LOHEGAON PUNE-411032
PROVN OF DEFICIENT INFRASTRUCTURE FOR COMMISSIONING OF AWS AT AFS PUNE AND SPECIAL REPAIRS TO INTERNAL WIRING, REPLACEMENT OF FITTING, FIXTURE AND CABLES AT KV-01 AFS PUNE
2025_MES_731972_1
8977
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KV-01 AFS PUNE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF LOHEGAON
₹98,000
Yes
26 Nov 2025
20 Sept 2025
14 Oct 2025
20 Sept 2025
9 Oct 2025
4 Oct 2025
Amount
Taking out cable of any dia/sq mm in trench/wall all as directed by Engr-in-Charge
Supply laying, joint testing & commissioning LT under ground cable 1100 volts grade XLPE insulated armoured with galvanised round steel wire or steel strep, electric power cable heavy duty, with multi stranded aluminum conductor, laid in trenches, ducts fixed on wall/poles with proper size saddles and clamp laid under road/path/drain/culverts or enclosed in GI pipe/fix complete all as specified, for following size :
(a) 70 Sq mm x 3.5 core
(b) 16 Sq mm x 4 core
(c) 6 Sq mm x 2 core
(d) 10 Sq mm x 4 core
Taking down old Lt Panel Supply install, test and commissioning Powder coated LT Panel (CPRA Approved) Powder coated, free standing type compartmentalized in construction center openable double door type with canopy factory fabricated from makes as specified and made out of 3 mm thick CRCA sheet & suitable size as apporved by GE to accomodate all accessories / fittings, MCCB, MCB, Contactors and TPN Copper bus bars having rating cap of 400 A. The TPN copper bus bars bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The Out Going MCCB of rating greater than 125 amps shall have copper extension link & copper bus bar for connecting the cables. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 50 mm X 50mm X 6mm & detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & Back openable lockable /openable by key from both sides.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground vertically at a depth not less than 2.25m below normal ground level with top level of earth plate at depth not less than 1.5m below normal ground level surrounded form all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using GI strip 25mmx4mm by means of bolts, nuts, check nuts and washers of galvanized iron and protected by GI pipe light grade 50mm bore connected to main switch board or main control board and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, 80mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation; and earth work, disposal of surplus soil to a distance not exceeding 50m all as specified and as shown in Electrical Plate No 3 of MES Schedule Part-I.
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m deep for laying of cable etc and getting out soft/loose soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Removal of surplus soil to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 above the starting point complete all as directed.
S&L Sand cushioning to cable with 80 mm layer before laying of cable and 150 mm after laying the cable in trenches/ ducts for cable including consolidation complete all as specified
S&L Brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified.
Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light point complete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge.
Taking down cearfully by unscrewing the unserviceable DB Boxes, MC distribution boards SP & TPN with porcelain cutouts etc all as directed.
Taking down the sub main wiring of any dia / sq mm on teak wood batten / PVC conduit GI earth wire all as directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open type Plastic Enclosure( Plastic Switch Board ) ISI Marked for housing switches / sockets all a specified and directed
(a) One light point controlled by one switch .
(b) One Fan point controlled by one regulator/switch.
(c) One 3 pin socket 5A on independent board
(e) One 3 pin socket 5 A on the same switch board.
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open type Plastic Enclosure (Plastic Switch Board) ISI marked for housing one 15 A Switch / sockets all a specified and directed
Supply and fix switch piano flush type 5 Amp one way. (ISI marked)
Supply and fix Socket out let , 3 pin 5 Amp (ISI marked)
Supply and fix switch socket combination 5 / 16 A, 2 in 1, 5 Pin, flush type.(ISI marked)
Supply and fix ceiling rose surface type bakelite / PVC three terminal 65 x 50mm. (ISI marked)
Taking down old light fitting along with fixture and Supply & fix LED tube light fitting comprising of 20 watt Aluminium T-8 LED tube rod with inbuilt driver and acessories, the tube rod shall have efficacy of 100 Lm/Watt, including providing prewired CRCA box type batten with holders for fixing LED Tube rod along with provision of 02 no PVC square block for fixing of the fitting with necesary screws, including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal complete as specified and directed.
Taking down old light fitting along with fixture and S&F high quality indoor surface and wall mounted industrial box type batten suitable for 2 x 20 watt Aluminium T-8 tube rod 4 feet long, including LED retrofit Tube rod 20 w Aluminium T8 tube rod 4 feet long 6000K colour temperature, having lumen output not less than 100 Lumen per watt & integrated electronic driver with industrial grade heavy duty driveer having THD<10%. complete with all accessories internally pre wire and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiig rose to fitting terminal complete all as specified and directed
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and LED lamp, clamps for insulation complete all as specified and directed.
M/L for sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable for continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified. (Note:- Three runs of 4 Sqmm copper cable including PVC casing & caping shall be mesured and paid as one length)
M/L for sub main wiring with two runs of single core 6.0Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:- Three runs of 6 Sqmm copper cable including PVC casing & caping shall be measured & paid as one length )
M/L for sub main wiring with two runs of single core 10 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 10 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping all as directed and specified . ( Note:- Three runs of 10 Sqmm copper cable including PVC casing & caping shall be measured & paid as one length )
S&F Vertical double door Distribution board TPN 4 way with nuetral busbar and consisting of MCCB 4pole 100A 10KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 100A, 4pole, 10KA -01 Nos is included in quoted rates)
Supply and fix sheet metal enclosure surface mounted MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge.
Supply and fix sheet metal enclosure surface mounted MCB DB double door SPN 8 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge.
Supply and fix MCB TP 40 Amps complete all as directed at site.
Supply and fix MCB SPN 240 V, 32 Amps. complete all as directed at site.
Supply and fix MCB SP 240 V ,6 to 32 Amps complete all as directed at site.
Supply and fixing ceiling fans complete with blades, down rods uptp 1 meter, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and hole cutting in wall all as specified & directed
Supply and fixing in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed
M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 1991 & testing complete including 15mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GI watering pipe etc.
S&F Junction box made out of FRP sheet of make SINTEX ready made type having 4 nos bakelite connector of size 388X304X170 mm with necessary connector MCB 16 Amps and entry of gland and fixing arrangement to fix the box on pole / wall by providing MS clamp of size 25X5 mm -2 Nos as per product complete all as specified and directed.
Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type outdoor Confirming to IS 8623 Part 1 1993, free floor standing factory fabricated made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom channel of size 75x40 mm . A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection, complete as specified and consisting the following switchgears and accessories :
(i) Incoming MCB DP 240 Volt 63 Amps - 01 Nos (ii) Outgoing MCB DP 240 Volt 32 Amps - 03 Nos (iii) LED Type RYB Phase Indicator -01 Set (iv) SPN Copper bus bar with colour code 100 APMS Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be fabricated from CPRI approved manufacturer
Supply and laying in trenches or fixing to wall/pole/ducts or passing through pipe PVC insulated heavy duty electric cable with Armoured Copper conductor 1100 volts grade cross sectional area 10 Sqmm 2 core.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge.
Supply and fix Isolater DP 240 V, 63 Amps 10 KA C Curve in DB complete all as directed at site.
Supply and fixing 50 mm dia HDPE pipe in trenches, pressure not less than 6 Kg/Sqcm, PE-63 grade any approved make etc complete all as specified and as directed
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt ,all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm , 7.5 meter long, etc complete all as specified and directed. Note- (i) Vendors are bound to get earthing result less than or upto1 Ohm with or without the grid of earthing.(Maximum number of new earthings in grid are restricted to 3 nos) Any additional work and material required to achieve the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate)
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out hard/dense soil complete all as specified and directed.
M&L 100mm thick PCC 1:4:8, type D2, using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L hardcore of gauge exc 63mm but not exc 100mm deposited, spread, and levelled in layers not exc 15cm thick watering, ramming to a true surface broken stone or boulders complete all as specified and directed.
M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour ,design & pattern as in footpath, parks,drive ways or light traffic parkings etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / layer of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator , filling the joints with sand and cutting of paver blocks as per required size and pattern , finishing and sweeping extra sand complete all as specified and directed.
M&L PCC B1, 1:2:4 using 12.5mm graded stone aggregates as in lintels upto 1.5m clear span,cills,steps,seismic and other similar bands, plinth courses,string courses, lacing courses,parapets and railings upto 60cm height,copings, kneelers,apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed.
M&L Factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including raking out joints with or without grooves (thickness of joint except at sharp curve shall not more than 5mm including making drainage opening wherever required complete all as specified and directed.
SHAH BUILDERS (BID ID -3446677)
PROLINK COMPUTERS (BID ID -3446746)
D H L ENTERPRISES (BID ID -3446191)
M/s Harshal Traders (BID ID -3446783)
K K ENGINEERING SERVICES (BID ID -3445960)
George Electricals (BID ID -3446738)
Sunhari Electricals (BID ID -3446857)
KSP ENTERPRISES (BID ID -3446749)
A.B.CONSTRUCTION (BID ID -3446885)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .