Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.4 L+₹4.1 L (17.0%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹29.0 L+₹4.7 L (19.3%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L3 | Rejected-Finance Being Higher Bidder | |
| 4 | L4₹29.2 L+₹5.0 L (20.4%)Rejected-Finance | L4 | Rejected-Finance Being Higher Bidder | |
| 5 | L5₹29.7 L+₹5.4 L (22.1%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L5 | Rejected-Finance Being Higher Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT AND REPLACEMENT OF STREET LIGHTS, FLOOD LIGHTS, LT POLE, PANEL AND OTHER MISC WORKS FOR 11 GRRC, OTM/MD ACCN AT WEST OF MG ROAD IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2022_MES_561018_1
GE/EM/LKO/EXT(ELECT)/T-52 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
13 Dec 2022
2 Nov 2022
23 Nov 2022
2 Nov 2022
21 Nov 2022
16 Nov 2022
Amount
Dismentling and taking out existing unserviceable street light fittings / flood lights of any type from pole / bldgs incl brackets and electric connections complete all as specified and directed.
Taking down existing unserviciable bollard light/post Top Lantern fitting complete all as specified and directed.
Supply and fixing of 60 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted DriverTHD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete all as specified and directed. (Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement)
Supply and fixing of 90 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted Driver THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete all as specified and directed. (Note :-The contractor should take approval of techincal specification of street light and driver from department before procurement)
Supply and fixing of 45 W LED Street light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution . street light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 100>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED driver with APFC, lower THD, open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD , and provided with company LOGO ingraved on housing of the Street light complete all as specified and directed. Note :-The contractor should take approval of techincal specification of street light and driver from department before procurement.
Supply and fixing of 120 W LED flood light fitting having epoxy powder coated pressure die cast aluminium housing front cover with polycarbonate lens with silicon gasket, with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant.IP lens for better distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 110>_ lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,Street light should have built in potted IP 66 electronic LED potted driver with open circuit protection , over voltage protection , surge voltage protection 5KV in built & 10KV SPD and provided with company LOGO ingraved on housing of the flood light complete all as specified and directed. Note :-The contractor should take approval of techincal specification of of street light and driver from department before procurement.
Supply and fixing bollard light 60 cm long 10 - 12 watt LED Bollard light having epoxy powder coated pressure die cast aluminium housing Light optic /Diffuser - High impact polycarbonate/Optic colour temprature 5700K CRi>70,THD<10% PF >.90 surge protection 4KV inbuilt ,Rated voltage and frequency 240 Volt,50 Hz. aesthetic innovative design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landsscape IP 65 environmental complete with foundation work nut,bolt and washer etc complete all as specified and directed.
S&F Post top energy saving 240V,50Hz AC, environmental friendly, aesthetically designed electronic constant current,IK07, having epoxy powder coated pressure die cast aluminium housing Top cover spun Al sheet powder coated,front cover Clear acrylic diffuser with indirect symmetrical light distributio, IP-65 luminaire with high power LED as light source of capacity 40 Watt, 5700K PF >0.9, THD<10% and light efficiency 85> ,CRI > 70,Surge protection 5KV complete all as specified and directed.
Supply and fixing security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos clamp made out of 50mm x 5mm flat iron and 06 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old unsv bracket complete all as specified and directed.
Supply and fixing street light junction box of suitable size for three phase cable connection outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings :- (a) Bus bar with four aluminium strips, 100 Amps capacity insulated with insulators, including colour coding strip, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 40mm x 5mm flat iron duly welded with nuts & bolts including taking down old unsv junction box complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 45 to 90 Watt LED flood light/street light fitting as required at site or as per sample including taking down old unsv drivers/PCB/electronic gear complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 120 to 150 Watt LED flood light/street light fitting as required at site or as per sample including taking out old unserviceable drivers/PCB/electronic gear complete all as specified and directed.
Supply and fixing Street light fitting electronic constant current drivers/PCB/electronic gear suitable for 200 Watt LED flood light/street light fitting as required at site or as per sample including taking out old unserviceable drivers/PCB/electronic gear complete all as specified and directed.
S&F PVC insulated, PVC sheathed twin flat core 1100 volts grade, 4 sqmm aluminium stranded conductor from OH conductor or from junction box to street/security light complete all as specified and directed.
Supply, laying jointing and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4.0 core, laid in trench/laid under floor or fixed naked with wall/on wall/in ducts/in GI pipes etc. with and includings MS Clamps, nuts,bolts,washers complete all as specified and directed. (Note- Excation, earth works,and sand cushioning,protection bricks/tiles/blocks and pipe shall be measured and paid seprately under given items)
Supply and installed steel tubular swaged pole type 410 SP - 31 (9 mtr long) complete with MS base plate of size 300x300x6mm thick at bottom, welded at the centre with through hole of 14mm dia at a height of 300mm above the coping finial cap and painted with two coats of aluminium paint over a coat of red oxide primer with writing number with and including excavation upto required depth and PCC type C-2 1:3:6 (using 40mm graded) at bottom and PCC type B-1 1:2:4 (20mm graded) for mass filling and pole coping (60x60x30cm) and rendering of coping with 10mm thick in1:6 cement mortar complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using stone aggregate of 40mm nominal size in foundation concrete for pole/strut complete all as specified and directed.
M & L for PCC 1:3:6 type C2 using stone aggregate of 40mm nominal size in foundation concrete for stays complete all as specified and directed.
M & L for PCC 1:3:6 type C1 using stone aggregate of 20mm nominal size in foundation concrete for coping of poles complete all as specified and directed.
M&L for earthing complet with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m in deep below ground level with top edge of the plote not less than 1.5m deep below normal ground level connected to and incl 4mm dia galvanised wire as earth lead wire by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 5 of SSR (1991) part-I incl 15mm bore GI pipe for protection upto 5 mtr length and PCC 1:2:4 type B-1 as in pit excavation and earth work in any type of soil charcoal common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron fixing and wiremesh and testing on completion complete all as specified and directed.
S&F LED lamp 10 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL, complete all as specified and directed.
S&F GI Pipe light grade 40 mm with all fitting such as clamp nuts bolt washer etc laid in trenches / under road / path /bollard light, Post top lantern fittings etc complete all as specified and directed.
All as per item No 22 above but 50 mm
All as per item No 22 above but 80 mm
M&L for painting of steel tublar/rail pole 09/11 meter long with silver aluminium paint of two coat after preparing surface & Marking number on pole with black paint complete all as specified and directed.
Supply and fix three phase street light power contactor 3 pole AC1 rating 45 Amp MNX 25 suitable for 45W to 150 watt street light including disconnecting and taking out old and unsv, complete all as specified and directed.
Supply and fix three phase automatic street light switch suitable for 3 to 5KW load complete with two numbers infrared sensor based NATURE SWITCH for automatic switching of street/security lights including taking out old UNSV, complete all as specified and directed.
Supply and fix three automatic street light switch suitable up to 08 KW load complete with two numbers infrared sensor based NATURE SWITCH for automatic switching of street/security lights with one number three pole power contractor 20 Amps with coil voltage 440 V and incoming MCBs single pole - 01 No, out going MCBs single pole - 01 No of rating 63 Amps & circuit wiring with single core multistranded of size 10 sq mm lighting switch operation should be based on natural light lux level, Required lluminance level for switching ON is < 30 Lux. The sensor (one service and one stand by) should also have part night operation facility for 4,5,6---------11&12 hours. The sensor along with suitable power contractor (S), incoming and out going MCBs should be enclosed in a pole/wall mountable enclouser made of Rust proof, Electric shock proof,termite proof and FR grade confirming to IP66 complete all as specified and directed.
Excavation in trenches in soft/Loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick work with fly ash bricks as per IS 12894 -2002 laying in trenches for protection of cable complete all as specified and directed.
Boring/drilling (Horizontly) manually/mechanically under existing road max 10 M in depth) suitable for passing GI Tubing 40 to 100 mm bore complete all as specified and directed.
M/s A.K Construction
NAVJYOTI ENTERPRISES
Prime power system
M/S S.B. Singh and Sons
MTR GROUP & COMPANY
Diamond Electric Co.
Ajanta Motor Store
Aawadh associates
Saurabh Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .