Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
25 Sept 2021, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_469898_1
8344/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
E b(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹50,000
Yes
27 Oct 2021
23 Aug 2021
27 Sept 2021
23 Aug 2021
25 Sept 2021
11 Sept 2021
23 Aug 2021 - 1 Sept 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surfaces of walls, floors, as per existing finishes etc complete all as specified and directed.
Taking down carefully unserviceable/partly unserviceable light fittings any type, tube light fittings and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Taking down serviceable/unserviceable electric meter including meter box from existing position carefully for refixing adjacent to main switch board including making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
Fixing only serviceable electric meter on & including wooden board to the wall and including making good disturbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L for the following point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and hylam switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface complete all as specified and directed. Make of cable - FINOLEX / PLAZA / HAVELLS/POLYCAB & Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note : (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling.
-ditto- all as per item No 5 above but One light point controlled by one way switch
-ditto- all as per item No 5 above but One ceiling /exhaust fan point controlled by one switch and regulator
-ditto- all as per item No 5 above but One 3 pin 5 amp socket out point on the same board with other switches.
-ditto- all as per item No 5 above but One 3 pin 5 amps socket out let point on independent board
-ditto- all as per item No 5 above but One bell/buzzer point controlled by one bell push.
-ditto- all as per item No 5 above but One light point controlled by two 2-way switches
-ditto- all as per item No 5 above but for one socket outlet 15 Amp on independent board with 2.5Sqmm (FRLS) cable and 1.5 Sqmm (FRLS) earth wire.
S&F Switch piano flush type single pole one way 5 amps of ISI mark. Make : Havells/ Anchor/ Plaza
S&F Switch piano flush button type two ways 5 Amps of ISI mark. Make : Havells/ Anchor/ Plaza
S&F Socket out let 2 in one, 5/3 pin 5 Amp of ISI mark. Make : Havells/ Anchor/ Plaza
S&F Switch socket combination 5 Amps 5 pin flush type duly ebbosed ISI mark. Make : Havells/Anchor/ Plaza
S&F Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal. Make : Havells/Anchor/ Plaza
S&F Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified. Make : Havells/ Anchor/Plaza
S&F Call bell AC-230 Volt single pole ding dong. Make : Havells/Anchor/Plaza
S &F Bell push, flush type 5 Amps. Make : Havells/Anchor/Plaza
S&F regulator electronic step type 100/120 watt 5 step complete all as specified and directed. Make : Havells/Anchor/Plaza
S&F Lamp holder insulated body with back plate for angle holder all as per specified and directed. Make : Havells/Anchor/Plaza
S &F in repairs LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x20 Watt, 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc.with all accessories internal prewired & including coneecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos complete all as specified and directed. Make- Havells Cat Pt No SABERLP36WLED840SPMMAWH or Equivelant of Philips/Bajaj.
S &F in repairsLED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack,1x10 Watt, 2 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc.with all accessories internal prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos complete all as specified and directed. Make- Philips Cat Pt No Philips 20W B22d_3 Crystal white t Bulb or Equivelant of Havells/Bajaj.
Supply and fix in repairs LED security light fitting of 30 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of make Havells Cat Part No ENDURAPEARLSL30WLED757SASYTOPCMP or Bajaj Cat Part No EXNT P 36L WH CR PC SD or equivelant of Philips/Bajaj.
S&F Surface mounting round, decorative LED down lighter 12 WATT and transulent defuser, prefixed with flat profile and mounting clamps etc complete all as specified and directed. Make Havells Cat Pt No ENDURANEODLR15WLED840MOD or Equivelant of Philips/Bajaj.
S&F in repairs LED light fittings decorative 34/36 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc complete all as specified and directed. Make Havells Cat Pt No BOCR2X2R60WLED857SPCMSGENSSL or Equivelant of Philips/Bajaj.
S&F in repairs LED light fittings decorative 36/34 Watt recess mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc complete all as specified and directed. Make Havells Cat Pt No VENUSNEO2X2PLR18-48WLED840MOD or Equivelant of Philips/Bajaj.
S&F in repairs GI pipe 'light grade' bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 30W security light fitting complete all as specified and directed.
S&F in repairs earth enclosure with 2 pin earth plug socket complete with MCB SP 20/25 Amp, flush mounting type complete all as specified and directed. Make -Havells/ LEGRAND/L&T
Taking down ceiling Fan/Exhaust Fan of any size or make complete all as specified and directed.
Hanging only ceiling fan of 1200mm/1400mm/1500mm during wiring Sweep by providing fan hooks in proper manner and making connection with 3 core copper cable including painting all as per specified and directed by Engr-in-Charge.
Fixing only Exhaust fan 230/250/300/380/450 sweep heavy duty including 3 core copper cable & cutting holes if required etc complete all as specified and directed.
S&F in repairs capacitor 2.5 mfd suitable for ceiling fan/exhaust fan complete all as specified and directed.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces complete all as specified and directed.
S&F MCB DB made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door. Make -L&T/LEGRAND/ SCHNEIDER
S&F MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 4 ways Double door IP-43-IK09 protection grade complete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail ,230 Volts SPN with 8 ways Double door , IP-43-IK09 protection grade complete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 12 ways Double door IP-43-IK09 protection grade complete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
NOTE FOR ITEM Nos 28 to 32 - (i) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall/DB to be fixed on wall including frame made out of MS flat 40x5mm (ii) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface. (iii) MAKE OF DB & MCB L&T/LEGRAND/ SCHNEIDER
S&F in repair of pvc insulated unsheathed bright annealed bare copper conductor 0.5 sq mm cond. const (NO./Dia mm) (16/0.20) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/ Plaza
S&F in repair of PVC insulated unsheathed bright annealed bare copper conductor 0.75 sq mm cond. const (NO./Dia mm) (24/0.20) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/ Plaza
S&F in repair of PVC insulated unsheathed bright annealed bare copper conductor 1 sq mm cond. const (NO./Dia mm) (32/0.20) single core industrial cable & PVC insulated, PVC round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/Plaza
S&F in repair of PVC insulated unsheathed bright annealed bare copper conductor 1.5 sq mm cond. const (NO./Dia mm) (30/0.25) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/ Plaza
S&F in repair of PVC insulated unsheathed bright annealed bare copper conductor 2.5 sq mm cond. const (NO./Dia mm) (50/0.25) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/ Plaza
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm (FRLS), earth continuity conductor of size 2.5 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 2.5 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm (FRLS), earth continuity conductor of size 4 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 Single core of size 16 Sqmm (FRLS), earth continuity conductor of 2 Single core 10 Sqmm (FRLS) to be drawn through in and including on metallic PVC conduit medium grade 80 mm dia with fittings (ISI marked) on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) FOUR wires of 16sqmm and TWO wire of 10 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 Single core of size 10 Sqmm (FRLS), earth continuity conductor of size 2x6 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 50 mm dia with fittings (ISI marked) on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Four wires of 10sqmm and two wire of 6 sqmm & PVC conduit shall be measured as one unit. Note : For Item Nos 38 to 41, The makes of wire : PLAZA/ FINOLEX/ PARAGON/ HAVELLS and Makes of conduit : KISAN/ FINOLEX/ SUPREME
S&F in repairs MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps complete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating ccomplete all as specified and directed. Make -L&T/LEGRAND/SCHNEIDER
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (Part-I)
Refixing of servicable MCB any type or size
Taking down partly unservicable tube light fittings any type,and fixtures, etc, and Refixing the same after repair including making good the disturbed surface complete all as specified and directed.
Supply & Fix in repairs latest version, energy saving LED bulb of 7 Watt of make Phillips/Havells/Bajaj.
Supply & Fix in repairs latest version, energy saving LED bulb of 9 Watt of make Phillips/Havells/Bajaj.
Supply & Fix in repairs latest version, energy saving LED bulb of 12 Watt of make Phillips/Havells/Bajaj.
Supply & Fix in repairs latest version, energy saving LED bulb of 15 Watt of make Phillips/Havells/Bajaj.
Supply & Fix in repairs LED tube rod retrofit type of 18/20 Watt energy efficient,eco freindly of make Crompton Cat Pt No LT5RT-18-CDLor Havells Cat Pt No LHLDEFXD5L8R020 or Philips Cat Pt No 20W865 T8 IND I-2100 lm, or Bajaj Cat Pt No BLRB 20W CW LED.
Supply & Fix in repairs LED Batten suitable for 18/20 Watt LED tube make of Crompton Cat pt No DMLN1LT8-16 or Havells Cat Pt No LHFXCEP1TNNW020 or Philips Cat Pt No BN021C LED20S PSU CW GR S2, Or Bajaj Cat Pt No BLRB-DB-118 I.
Supply & fix in repairs post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 15/20 w led lamp fitting including lamp all as specified and directed. MAKE: HAVELLS/Philips/Crompton/Bajaj
Supply & Fix in repairs electronic ballast suitable for 1x36 watt tube light fitting of make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x28watt of make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs copper ballast suitable for 1x36watt of make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x18watt of make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x36watt CFL fitting of make - CROMPTON/ BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x11watt CFL fitting ofmake - CROMPTON/ BAJAJ /HAVELLS
Supply & Fix in repairs bipin holder suitable for 28/36 watt tube light fitting of make CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs starter holder suitable for 40/36 watt tube light fitting of make CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs starter suitable for 40/20 watt tube light fitting CROMPTON- / BAJAJ /HAVELLS
S&F in repairs PVC rectangular block of size 100 x100 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover complete all as specified and directed. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 175 x100 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover complete all as specified and directed. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 200 x150 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover complete all as specified and directed. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 250 x200 x50mm for mounting switches, sockets/fan Regulator etc with 3mm thick plastic laminated sheet cover complete all as specified and directed. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 350 x300 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover complete all as specified and directed. Make : Anchor/Press fit/Havells/C&S
S&F in repairs modular switch piano flush type single pole one way 5 amps. Make : Anchor/ Havells/ Leader/ HPL
S&F in repairs Modular socket out let 2 in one, 5/3 pin 5 Amp. Make : Anchor/ Havells/ Leader/ HPL
S & F in repairs modular switch socket combination 6 pin, 3 module 5/15 Amps flush type universal complete all as specified and directed. Make : Anchor/ Havells/ Leader
S&F in repairs modular bell push, flush type 6 Amps. Make : Anchor/ Havells/ Leader
S & F in repairs modular electronic regulator 100/120 watt step type. Make : Anchor/ Havells/ Leader/ HPL
S&F MCCB DB vertical type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door complete all as specified and directed. MAKE - L&T/LEGRAND/Havells
Taking down and dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spareparts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and supply and fixing the following items and including necessary transportion to workshop, for 1200/1400/1500mm sweep fan complete all as specified and directed.-
(I) Split pin - 02 Nos
(ii) Connection block - 1 No
(iii) Insulation rubber bush. - 01 No
Fixing or hanging only ceiling fan after winding fan under item No. 01 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) complete all as specified and directed.
All as pr item No. 01 here-in-above but exhaust fan of size 225mm to 450mm sweep (except rubber roll, split pin) complete all as specified and directed.
Fixing only Exhauest fan after winding fan under item No. 03 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) complete all as specified and directed.
All as pr item No. 01 here-in-above but air circulater fan of size 600 mm to 750mm sweep (except rubber roll, split pin) complete all as specified and directed.
Fixing only air circulater fan after winding fan under item No. 05 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) complete all as specified and directed.
All as pr item No. 01 here-in-above but wall fan of size 300 to 400 mm sweep (except rubber roll, split pin) complete all as specified and directed.
Fixing only wall fan after winding fan under item No. 07 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) complete all as specified and directed.
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion complete all as specified and directed. including taking down.(Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares required shall be measured and paid separately in the relevant items).
Taking down exhaust fan, of any size and type & cleaning/servicing and overhauling the same, refixing the same on its existing position and connection up complete all as specified and directed.
Supply, fixing and connecting up flexible copper wire twin core of 23/.0078.
Supply only gun metal bush of any size (Make - MSP).
Supply only bearing for ceiling fan (Make - TATA/SKF No.6201/6202).
Supply only bearing for ceiling fan (Make - TATA/SKF No.6203/6204).
Supply only fan condensor 4 MFD (Make – USHA / UNIVERSAL).
Supply only split pin.
S&F canopy of ceiling fan bottom and upper side of size 1200/1400/1500mm Make :- Usha / Orient / Bajaj/Havells
Painting of ceiling fan 1200/1400 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified and directed.
supply & fix fan blade made out of aluminium alloy suitable for wall mounting fan of sizx 300 to 450 mm complete all as specified and directed.
Supply & fix GI tubing light grade 40 mm dia use as down rod of ceiling fan ,cut to required length & incl. drilling of hole at both side complete all as specified and directed.
Supply & fix GI tubing light grade 20 mm dia use as down rod of ceiling fan ,cut to required length & incl. drilling of hole at both side complete all as specified and directed.
Supply & fix GI tubing light grade 15 mm dia use as down rod of ceiling fan ,cut to required length & incl. drilling of hole at both side complete all as specified and directed.
S & F in repairs Mild steel work in framed work such as Fan hooks, Clamps, gratings, ladders etc., with ends of bars welded and/ or riveted, or forged and similar work confirming to Fe 410 - O or Fe 310 - O and incl painting to surfaces using two coats of metallic primer and a coat of synthetic enamelled paint of desired colour complete all as specified and directed.
Taking down of MCCD DB/MCCB of any types and any size
S & F MCCB 63 Ams 4P thermal magnetic realease typ of make legrand /Seimens/Havells
S & F MCCB 100 Ams 4P thermal magnetic realease typof make legrand /Seimens/Havells
S & F MCCB 160 Ams 4P thermal magnetic realease typ of make legrand /Seimens/Havells
S&F in repairs infra red light sensor (Ceiling mounted) with adjustable dusk to down setting to sense motion and direct wheather human has moved in or out of the sensor range time delay control min 10 sec plus minus 5 sec, max plus minus 2 min adjustable, light label control 5 lux to 2000 lux, rated load 1100 watt (incandscent), 550 watt halogen or 250 watt LED complete with testing complete all as directed by Engr-in-Charge. Make Vinay/ Luker/ Phillips/Bajaj.
Taking down and refixing water storage type electric geyser of capacity 25/50 Ltrs 230 volts 50 Hz single phase and installed complete with proper fixing arrangement nut bolts & washers properly after repair work complete all as specified and directed.
S&F in repairs water storage tank of Geyser Vertical type capacity 25 Ltr made of stainless steel complete all as specified and directed.
S&F in repairs water storage tank of Geyser Horizontal type capacity 25 Ltr made of stainless steel complete all as specified and directed.
S&F in repairs glass wool of any colour complete all as specified and directed.
S&F in repairs heating element of 1500 watt triangular type for geyser complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs heating element of 1500 watt circular type for geyser complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs heating element of 2000 watt for geyser trangular type complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs heating element of 2000 watt for Solar System complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs thermostate for geyser complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs neon lamp yellow/red for geyser complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs air release valve for geyser complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs PVC connection armoured type both side brass union type nuts 45/60 cm length as specified and directed.
S&F in repairs anchor bolts 75mm long made out of stainless steel complete all as specified and directed.
S&F in repairs PVC insulated 3 core 2.5sqmm multistranded COPPER conductor for connection of Geyser complete all as specified and directed.
S&F in repairs geyser assembly suitable for 25 Ltr capacity complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs geyser assembly suitable for 50 Ltr capacity complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs Metal plug top 10 Amp, 3 Pin phase neutral and earth complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs Metal socket top 10 Amp, 3 Pin phase neutral and earth complete all as specified and directed. Make : Bajaj/ Toshiba/ Havells
S&F in repairs Ventilair of 200 mm internal daimeter and 62.5 CM x 35.2 CM x 38.3 CM of plastic frame of white colour allas spesified and directed by Engineer of Malke Havells Ventil Air DX 200 or equivalent of Phillips/Bajaj
Supply and fix in repairs LED security light fitting of 45 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of make Havells Cat Pt No ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent of Phillips/Bajaj
Supply and fix in repairs LED security light fitting of 60 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of make Havells Cat Pt No ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent of Phillips/Bajaj
Schedule of credit amount of Rs. 1,34,297.00 to be deducted during AOC
S K TRADERS
Skyline Encon
Goodluck Enterprises
shri krishna traders
a k builders
RAINA SALES AND SERVICES
M/s Ajayshwar Singh Rana
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .