| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹29.8 L+₹6.4 L (27.2%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹30.5 L+₹7.1 L (30.1%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹35.2 L+₹11.7 L (50.0%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹36.9 L+₹13.5 L (57.5%)Rejected-Finance SHOP NO 18 1ST FLOOR NORTH LAND BUILDING SECTOR NO 1 BACK SIDE OF BANK OF MAHARASHTRA INDRAYANI NAGAR BHOSARI PUNE 411039 | PUNE | MAHARASHTRA | 411039 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹77,580
Closing Date
9 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
PROVN OF FORTIFICATION OF SMALL ARMS SHED AT STN WKSP EME KHADKI UNDER GE MH AND RH KHADKI
2023_MES_609121_1
8483/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹77,580
10 Oct 2023
14 Jul 2023
11 Aug 2023
14 Jul 2023
9 Aug 2023
4 Aug 2023
14 Jul 2023 - 9 Aug 2023
Amount
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as directed
M&L for 20-25 mm thick machine cut machine polished kota stone slab in flooring but one piece as in treads of straircase etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing moulding, laid over and including 15 mm thick screed bed or bedding in CM 1:3 for laying floor finishes, all as specified and directed.
M&L for 18-20 mm thick machine cut machine polished kota stone slab in flooring but one piece as in treads of straircase etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing moulding, laid over and including 10 mm thick screed bed or bedding in CM 1:3 for laying floor finishes, all as specified and directed.
M&L for Pre-cast cement concrete block masonry of PCC 1:3:6 Type C1 using 20mm graded stone aggregate with solid blocks straight or curved on plan, exc 6m mean radius and exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Reinforced cement concrete M-25 grade (design mix) 20mm graded stone aggregates Beams, cantilevers, bressummers,lintels over span all as specified and directed. Note : Anchoring of proposed RCC beam into existing coloumns incl making good the existing surface all as per directed by the Engr-in-Charge.
M & L for steel formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M&L rendering 15 mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 and surface finished even and fair by mixing liquid water proofing compound as per manufacturers instructions complete. Note : Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
Supply only liquid water proofing compound hydroseal-W+ or eqivalent (for plaster hardening, to control efflorescence & fungal growth) as approved by GE.
M&L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for TMT bars 6 mm to 8 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
S&F aluminium louvered ventilators of section size 100mm x 25mm x 1.50mm including frosted glass fixed in half portion & adjustable type louvers in another half and stainless steel wire mesh fixed type on outside frame etc including taking down existing steel ventilator all as directed by Engr-in-Charge. Note : Glazing and 0.56 mm dia SS wire mesh with average width of aperture 1.18 mm shall be deemed to be included in unit rate quoted.
M&L for 1.25 mm thick of laths Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete with gear operated type with chain wheel and hand chain incl Safety lever locks mild steel with 4 levers for rolling shutter ball bearing for rolling shutters all as specified and direted.
supply & fixing tiled false ceiling of Everest Designer tile pre-painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing MS Steel frame, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 3mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, in repairs all complete at all heights as per direction of Engineer-in-Charge.
S&F powder coated (minimum thickness of powder coating shall not be less than 50 microns of approved colour) aluminium frame for partitions, doors, windows and ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating shall not be less than 50 microns of approved colour) aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified & directed Engineer-in-Charge.
Supply & fix for 5mm thick sheet glass ordinary quality and glazing exceeding 0.5 Sqm in each pane all as specified and directed.
S&F for 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work all as specified and directed.
Excavating in post holes (or similar hoels) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 mtr complete.
M&L for PCC M-15 grade (nominal mix) using 20mm graded stone aggregate in foundations, filling and mass-concrete complete all as specified and directed
S & F of mild steel work in angle iron or other stock section or core for wooden hand - rail straight portioon, drilled and countersunk for balusters, nosing of steps, including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe – 290 Gde E -165 complete all as specified and directed.
Supply only chain link of wire MS galvanised fencing of any size and any type complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, any size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
S&F mild steel round bars 10 mm dia fixed to chainlink fencing cut to length, bent to required shape including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed by Engineer-in Charge.
M&L for prepration of new steel surfaces, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed by Engineer-in-Charge.
S & F hot rolled medium and high tensile structural steel of Fe-410W grade E 250 quality A conforming to IS 2062: 2011 as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, but length of bolts exc 5cm but n exc 10cm long of diameter of shank 11 to 15mm
S&F for framed work such as gate, grills gratings flat iron,angle iron MS Sheet etc. with ends of bars shouldered and rivited or forged into spikes framed guard bar barred iron doors and similar work fixed at exc RCC Pillar as a MS frame work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engr-in-Charge.
S & F on site hume pipe septic tank designed to carry wast water and sullage water,incl excavation in any type and soil PCC M-7.5 grade (nominal mix) using 40mm graded stone aggregate below foundation, vent shaft, connection etc complete in for 10 users incl all necessary fitting as reqd & fixed complete on site all as per drg, as specified and directed.
M & L for 20mm thick Granite slab machine cut in jambs, cills, and like laid over cement screed and jointed with grey cement slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including cutting and polishing laid over & including screed bed 15mm thick in CM 1:4 complete on site as specified and directed.
S & F 3mm thick figured glass pin head type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 150 mm bore PVC (SWR) pipes type 'A' single socketed, in any length with rubber ring joints, fixed on walls complete all as specified & directed.
S&F 150mm dia PVC (SWR) bends any radius all as specified and directed.
M&L for of preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer finishing surfaces even and smooth, complete all as speciified and directed
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and directed.
Supply & fixing 15mm bore CP bib taps, cast copper alloy, with capstan heads, chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix 1000 liters capacity triple layer, rotational moulded, polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises all as specified and directed by Engr-in-Charge.
M&L Coloured Non Skid ceramic joint free tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or Coloured cement to match with colour of tile laid over and including 15 mm thick screed bed in CM 1:4 complete all as directed.
M & L for point wiring complete with and including 1.5 Sqmm (nominal area) single core multi stranded copper conductor PVC insulated but unsheathed FRLS cable 1100 volts drawn in to and including stove enamelled steel conduit ISI marked of suitable size including its accessories such as tee, bend, elbow, socket also including 1.5 sqmm PVC insulated and PVC unsheathed single core multistranded copper conductor FRLS cable 1100 V grade as earth wire for housing flame proof socket, regulator, switches etc complete including necessary FLP-WP multiple entry junction box of suitable size , FLP flexible metalic hose conduit and compressing cables with glands of flameproof double compression cable glands brass of suitable size and connecting to earth dolly all as specified and directed for the following:-
One light, fan point controlled by one no of one way flameproof switch
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS cable of size 1.5 sqmm 1100 volt grade drawn into stove enamelled steel concealed conduit of suitable size including 1.5 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing including chasing/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface complete all as directed by Engr-in-Charge. Note: Two single core cable 1.5 Sqmm, earth wire 1.5 Sqmm and stove enamelled steel conduit shall be measured as one length.
S & F Switch flame proof rotary type with termination box in LM6, 16 A, single pole 250 V, complete all as specified and directed.
S&F heavy duty flame proof exhaust fan with steel body, blades, frames and louvers of size 450 / 457 mm (18") sweep, AC single phase, 230 Volt, 1440 RPM with motor capacity 0.50 HP and air flow capacity 4000 cfm complete all as specified and directed. Make : Cat Part No EF/140 of Sudhir or equivalent make given under list of make.
M&L for point wiring using approved colour coding as per IS (Red, black and green for single phase circuits), with multi stranded copper conductor 1.5 Sqmm nominal cross sectional area,single core, PVC insulated and unsheathed FRLS cable1100 volts grade, ISI-694 (1990) marked with valid CML No in and including medium grade, PVC Conduit of suitable size on walls/roof/floor etc, ISI marked with suitable accessories, mild steel/ pressed steel sunken box of 1.2 mm thick and 60 mm deep (with earth dolly) duly painted with two coat of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulator etc, including PVC insulated multistranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by engr in charge for the following:-
One fan/light /bell point controlled by one switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
Supply and fix switch piano type one way 6 Amps flush type, 240volt AC all as specified and directed.
Supply and fix socket outlet 2 in1, 3 pin 5 Amps all as specified and directed.
Supply and fix switch socket combination (SSC) 2 in 1, 3 pin, 5 Amps flush type, 240volt AC all as specified and directed.
S & F sheet metal enclosures for double door distribution board factory made duly painted 8 way SPN 240V of following capacity with 200 amps rated bus bar, suitable for fixing MCB /Isolators all as specified
Supply and fixing miniature circuit breaker (MCB) of following current carrying capacity, in the MCB DB Complete with connection testing and commissioning
SP 5 to 32 AMP,240V, 10 KA 'B' curve
SPN 32 Amps,240V, 10 KA 'B' curve
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
M & L for earthing complete with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. Note:- (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge.
Supply & fix Aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
Supply & fix Galvanised iron strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof all as directed.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw as specified.
Material and labour for earthing complete with GI earth plate 600mm x 600mm x 6.3 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 40 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-15 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete. Note :- (i) Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth. (ii) Resistance value shall be less than 5 ohm.
Supply & fix four pointed (centre tip 150mm and side spike 75mm) copper spike lighting arrester heavy duty copper rod of size 15 mm dia both end screwed for easy fitment and 1.5mtr long and heavy duty copper base plate duly drilled on four corners of size 75mm x 75mm, with necessary fixing arrangement on top/side of pole complete
Aishwarya Constructions
Sunrise Traders
M/S JAYCONSTRUCTION CO
ShreHari Civil Enginneering and Contractors
Vastushilpa Contrustion
AGREN ENTERPRISES
M/S SANDEEP CONSTRUCTION COMPANY
Gruham Luxe Interiors
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .