Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.3 L+₹8.6 L (31.3%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L2 | Rejected-Finance Not Being lowest bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
12 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT AND IMPROVEMENT OF LT ELECTRIC SUPPLY DISTRIBUTION SYSTEM AND MISC WORK AT HQ CC, HQ MUPSA, HQ CELZ, CHQ (AMC), 71 BDE AND 41 BDE IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2021_MES_424856_3
GE/EM/LKO/EXT(ELECT)/T-92 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
Class D or above category b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹76,000
Yes
3 Sept 2021
21 Jul 2021
14 Aug 2021
21 Jul 2021
12 Aug 2021
29 Jul 2021
60 days
Amount
Out door luminaries light Aesthetically designed decorative hot dipped galvanised mild steel step pole 3 mtr height with grey powder finish. Compatible window - plasma cut & duly chamfered opening window of 300x100mm for terminal connections with mounting accessories post-top energy saving LED fitting 50 watt, environmental friendly, long life aesthetically designed with symmterical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed by Engineer-in- Charge.
Out door luminaries light Aesthetically designed decorative hot dipped galvanised mild steel step pole 3 mtr height with grey powder finish. Compatible window - plasma cut & duly chamfered opening window of 300x100mm for terminal connections with mounting accessories post-top energy saving LED fitting 25 watt, environmental friendly, long life aesthetically designed with symmterical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed by Engineer-in- Charge.
LED gate light fitting, post-top, energy saving, environmental friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium landsacpe IP65 luminaire with high power COB light as light source complete all as specified and directed by Engineer-in- Charge.
Bollard light 60 cm long, 8 watt street furniture with touch if aesthetic innovatiove design with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landscape environment complete with foundation work nut, bolt and washers etc complete all as specified and directed by Engineer-in- Charge.
LED gate light fitting, energy saving, environmental friendly, long life aesthetically designed with good symmetrical light distribution, spun aluminium landsacpe luminaire with high power LEDs as light source complete all as specified and directed by Engineer-in- Charge.
GI brackets made of 32/40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
MS Junction Box made of 1.6 mm thick MS sheet of size 200mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bas bar 100 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
Supply and errection in of 05 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps, Cat NO: HM-1107 P for pole and HM-SA 1 M for bracket. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 as per pole manufacturer's drawing and earth work all as per requirement complete all as specified and as directed by Engineer-in-Charge.
Shifting of LT pole 9 mtr from one place to another places of entier Cantt area , including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed.
LED street light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 45 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt fitting suitable for pole mounting bracket 40 mm. all releven documents related to luminaries and driver needed to submit for approval fixed as in replacment of old unservicable light , complete all as specified and as directed by Engineer-in-Charge.
LED street light fitting with mandatory driver set having pressure die cast aluminium body and lenses suitable for 60 watt confirming to IP 66 and IK 07 protection having company LOGO ingraved complete lumes high power LED with lenses Lumen efficacy of LED not less than 100 lumen per watt fitting suitable for pole mounting bracket 40 mm. all releven documents related to luminaries and driver needed to submit for approval fixed as in replacment of old unservicable light , complete all as specified and as directed by Engineer-in-Charge.
LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 120 watt IP 65 and IK 07 protection having company LOGO ingraved complete in respect with system lumes high power LED complete all as specified and as directed by Engineer-in-Charge.
LED flood light fitting with mandatory driver set having pressure die cast aluminium body (LM 6 alloy) and lenles suitable for 300 watt IP 65 and IK 07 protection having company LOGO ingraved complete in respect with system lumes high power LED complete all as specified and as directed by Engineer-in-Charge.
PVC perplex cover diamond shape suitable for post top lantern fittings of 18” dia fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
Preparation of old painted surfaces and painting of LT steel tubular pole 9 mtrs long from bottam to top with aluminium paint and painting to bottam up to 1.5 mtr height from top of PCC coping with sysnthetic enamel paint 2 coats in black and Yellow/white alternate strip including numbering in 8 cm height of number with white paint both paint aluminium /synthetic duly approved ,complete all as specified and as directed by Engineer-in-Charge
MCCB TP 63 Amps 10 KA, 415 Volts AC, 50 Hz, complete with in sheet metal enclosere of 1.6 mm thick MS sheet with powder coat painted including connecting with existing system and cabling network including making good disturbed surfaces including testing and taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge.
Painting on old painted surface of LT Panel/Feeder Piller Box by brushing after cleaning stain & grease spot with thinner and sand papar and painting the cleaned surface with synthetic enamel paint as existing colour to acheive good finish by applying two coat paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators, relays and switches to prevent fall of paint drop on them & including writing, numbering, letter etc with white paint on newly painted surfaces ,complete all as specified and as directed by Engineer-in-Charge
Maintenance of feeder pillar/LT panel indoor/outdoor type Panel by cutting corroded MS lid from LT panel, and weilding the same with 2 mm thick MS sheet in any desired shape including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends clean and replacement of following unserviceable parts with new nut bolts and washer , complete all as specified and directed by Engineer-in-Charge. Note : All spare parts and rewiring work will be measured and paid seperately under respective item of Sch 'A' as supply only and cost of fixing is deemed to be included in rates quoted against this item and nothing extra shall be admissible on this account .
Supply only multifunction meters in existing Panel of size 96X96 sqmm flush mounted case 3 line LED display, 1.0 Multifunction Panel Panel mounted meter 3 P2W/3P4W and -/ A or -/ A configurable, with RS 485 comunication port .
Supply only LED Indicator lamps (RYB) as per existing size
Supply only Aluminium bus bars of 200 Amp .
Supply only Powder coated CRCA sheet metal enclosure.
Solar street light 12 watt all-in one not less than 100 Lumen /watt mono crystal solar panel, Lithium iron batteryPWM charge controller , automatic power management LED driver efficiency 90% fixed as in replacement complete all as specified and directed by Engineer-in-Charge. Make: CG, Bajaj, Havells/osram
Supplying, Laying, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed including taking down the old unsv existing cable from site.
All as per item No 24 above but of size 16 Sqmm 4 core
All as per item No 24 above but of size 25 Sqmm 4 core
All as per item No 24 above but of size 50 Sqmm 3.5 core
All as per item No 24 above but of size 95 Sqmm 3.5 core
All as per item No 24 above but of size 120 Sqmm 3.5 core
Taking out old unserviceable LT cable from trench and relaying/rerouting the same after removing of defects any type/size in trenches / road crossing /through pipes pat drains/ducts/floors/along poles/walls/ceilings complete all as specified and as directed by Engineer-in-Charge. Note - excavation and earth work will be measured and paid seprately in appropriate item.
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in soft/loose soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches , complete all as specificed and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type D-2 using 40 mm graded stone aggregates, as copping of poles complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth (punned down to 10 cm depth after laying and stretching of cable), complete all as specificed and directed by Engineer-in-Charge.Note: Punned thickness (over all 18 cm) shall be measured & paid.
Protection of cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge.
Boring / drilling (Horizontly ) manually under existing road Max 10 M in width suitable for passing GI tubing 40 to 100 mm bore, complete all as specified and as directed by Engineer-in-Charge.
End termination heat shrinkable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 25 Sqmm to 50 Sqmm x 3.5/4 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the end for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 38 above but of size 70 to 120 Sqmm
Straight through heat shirankable joint including sleeves suitable for LT XPLE underground aluminium conductor cable 1000 Volt of grade 25 Sqmm to 50 Sqmm x 3.5/4 Core cross sectional area including testing after jointing as in replacment after disconnecting the cable from Panel / Pole, preparing the for jointing including all earth work,complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 40 above but of size 70 to 120 Sqmm
Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
All as per serial item No. 42 above but of size 50 mm bore
All as per serial item No. 42 above but of size 80 mm bore
Trimming/pruning of the tree branches coming cross electric power head line LT feeder clearng the span and making the free from touching the tree branches ,complete all as specified and as directed by Engineer-in-Charge
Dismantling of existing old damage PCC pole/ steel pole of any description complete all as specified and as directed by Engineer-in-Charge.
Shifting of LT pole 9 mtr from one place to another places of entier Cantt area , including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint onecoats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) 30 cm interval and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and as directed by Engineer-in-Charge.
PVC insulated and PVC shethed Aluminium conductor multistrand 10 sqmm 2 core fixed on wall/ under ground in PVC conduit pipe 25mm in size complete all as specified and as directed by Engineer-in-Charge.
Flat twin core ,10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable in and including taking out of old unservicable cable , complete all as specified and as directed by Engineer-in-Charge.
Isolator 4P 100 Amp, 415 volts fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
Isolator TP 63 Amp, 415 volts fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
MCB SPN, 32 Amp 10 kA, 240 volts AC 'C' curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
MCB SP, 05 to 32 Amp 10 kA, 240 volts AC 'C' curve fixed as in replacment , complete all as specified and as directed by Engineer-in-Charge.
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from LT panel Board and supplying, fixing MCCB 100Amp 3/4 pole with spreader and suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and as directed by Engineer-in-Charge.
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from the LT panel Board and Supplying, fixing MCCB 160 Amp 3/ 4 pole with spreader and suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and as directed by Engineer-in-Charge.
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from the LT panel Board and supplying, fixing MCCB 200 Amp 3/4 pole with spreader and suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and as directed by Engineer-in-Charge.
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from the LT panel Board and supplying, fixing MCCB 250 Amp 4 pole with spreader and suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and as directed by Engineer-in-Charge.
Disconnecting all existing electrical connection from panel ,taking out unserviceable MCCB and cable from the LT panel Board and Supplying, fixing MCCB 400 Amp 3/4 pole with spreader and suitable size of cable lugs/thimble complete incl all electrical connection with making good the damaged surface complete all as specified and as directed by Engineer-in-Charge.
GIAN ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .