| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC | L1 | Accepted-AOC Awarded by Competent Authority |
| Sl No | Description | Qty | Unit | ISHTIYAQ ELECTROMACHENICALS L1 |
|---|---|---|---|---|
| 1.01 | SH -I
Earthing with G.I. earth pipe 4.5 mtrs long x 40mm dia i/c
accessories and Pdg. masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt) complete as reqd | 4 | Job | 33,200 ₹39,176 Lowest |
| 1.02 | Providing and laying earth connection from earth electrode
with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth
electrode including connection with G.I. thimble excavation and refilling etc as reqd. | 15 | mtr | 4,500 ₹5,310 Lowest |
| 1.03 | Providing and fixing 6 SWG dia GI wire on surface
or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring cable etc. as reqd | 25 | mtr | 1,500 ₹1,770 Lowest |
| 1.04 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required .
( TE Saltauwa & Rudhauli)
(a). 4 way (4+12), Double door | 2 | No | 18,400 ₹21,712 Lowest |
| 1.05 | Supplying and fixing following rating four pole 415 V isolator in the existing MCBDB complete with connections, testing and commissioning etc as reqd.
(a). 63 Amp | 4 | No | 4,800 ₹5,664 Lowest |
| 1.06 | Supplying and fixing 5 A to 32 A rating 240/415 volt 10 KA "C" curve MCB suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc as reqd.
(a). Single pole | 18 | Nos | 5,580 ₹6,584.4 Lowest |
| 1.07 | (b) Triple Pole | 2 | Nos | 2,400 ₹2,832 Lowest |
| 1.08 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit as reqd.
(a) 2x1.5 Sq mm | 35 | Mtr | 2,975 ₹3,510.5 Lowest |
| 1.09 | (b) 3x1.5 sq mm | 25 | Mtr | 2,950 ₹3,481 Lowest |
| 1.10 | {c}4x1.5 sq mm | 25 | Mtr | 3,625 ₹4,277.5 Lowest |
Tender Value
₹5.0 L
EMD Value
₹9,948
Closing Date
1 Aug 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Dismantling and shifting of 32.0 KVA EA set from Kaptainganj to Rudhauli, 15 KVA EA set from Ghandhinagar to Saltauwa and rectification of of various Faults in EI at OLT location Saltauwa,Rudhauli in OA Basti.
2025_BSNL_242038_1
27/TED/GKP/2025-2026
Open Tender
Government Stock/Security
Item Rate
90 days
Basti
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹9,948
16 Sept 2025
21 Jul 2025
2 Aug 2025
21 Jul 2025
1 Aug 2025
21 Jul 2025
SH -I Earthing with G.I. earth pipe 4.5 mtrs long x 40mm dia i/c accessories and Pdg. masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt) complete as reqd
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and refilling etc as reqd.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring cable etc. as reqd
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . ( TE Saltauwa & Rudhauli) (a). 4 way (4+12), Double door
Supplying and fixing following rating four pole 415 V isolator in the existing MCBDB complete with connections, testing and commissioning etc as reqd. (a). 63 Amp
Supplying and fixing 5 A to 32 A rating 240/415 volt 10 KA "C" curve MCB suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc as reqd. (a). Single pole
(b) Triple Pole
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit as reqd. (a) 2x1.5 Sq mm
(b) 3x1.5 sq mm
{c}4x1.5 sq mm
(a) 2x2.5 Sq mm
(b) 3x2.5 sq mm
{c}6x2.5 sq mm
Supply aqnd fixing following piano type switch / socket on the existing switch box / cover including connections etc as reqd. (a)5/6 amps switch
(b) 5 Amp 3pin Socket
© 15 Amp Switch
(d) 15 Amp 6pin Socket
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 20 mm dia
(b) 25 mm dia
SH-II Dismantalling & Disconnection of 15.0 KVA EA set & Canopy & all other EMS i/c Loading ,unloading and lifting with the help of crane, labours & transpotation of 15.0 KVA EA set and all EMS from Ghandhinagar BTS to Saltauwa etc complete as required.
Installation of dismantled 15.0 KVA EA set & Canopy & all other accessories at TE saltauwa i/c making connections propery ,testing,Commissioning etc as required.
Providing suitable PCC plinth with ratio 1:2:4 (1cement:2coarse sand:4stone ballast aggregate 20 mm nominal size) for installing the engine alternator set in canopy i/c plastering, cementing,curing and shuttering etc as required.( Plinth size:- length 2.4m x breadth 1.2m x height 0.5m.(at TE saltauwa)
Dismantalling & Disconnection of 32 KVA EA set & Canopy & all other EMS i/c Loading ,unloading and lifting with the help of crane, labours & transpotation of 32.5 KVA EA set and all EMS from TE Kaptainganj to TE Rudhauli etc complete as required.
Installation of dismantled 32 KVA EA set & Canopy & all other accessories at TE Rudhauli i/c making connections propery ,testing,Commissioning etc as required.
Supplying and fixing of 40/32 mm dia x 1.50 mtr long GI pipe (medium class) bracket for mounting of street light fitting on wall bending the pipe to the required shape2 nos 20 mm x 3 mm flat iron clamps with nuts and bolts and washers painting the flat iron with primer and finish paint etc as reqd.
Supply and fixing of 45 watt LED type energy saver with inbuilt day night sensor street Light fitting i/c connection ,testing etc complete as reqd (Havells or ss make)
Supplying and fixing of the 250 mm globe (Dom) model holder type fittings in the existing garden and compound light fittings i/c 15watt LED Bulb connections etc. complete as reqd.
Supply and fabrication of cage made out of 3mm MS wire mesh fabricated on 25mmx25mm angle iron frame for protection of gate lights from monkeys etc complete as required
Painting of existing compound lights pole with two coat of silver color paint etc complete as required.
Providing and fixing 20 watt LED tube fitting i/c connection with 1.0 sq mm copper wire as reqd.
Replacement of 63 Amp Kit Kat fuse unit i/c fixing, connection, etc complete as reqd. (M/S L&T/Havells/S.s make)
Supply and Fixing of 1200 mm sweep ceiling fan i/c regulator, connection, testing etc as reqd.
Supply and Fixing of electronic regulatorfor ceiling fan i/c connection, testing etc as reqd.
Replacement of 63 Amp 4 pole on load change over switch in sheet steel enclosure i/c connection, testing etc complete as reqd. (M/S HPL/Havells/S.s make)
Replacement of faulty AVR suitable for 15.0 KVA Alternator ( approved make) on the existing alternator to stablized the voltage etc complete as required. (At Saltauwa)
S/F of Dynamo (battery charger) of 15 KVA EA set i/c fixing,making control connection etc.complete as reqd.
Visit charges of the skilled mechanic with helper for tracing out various faults of EI /engine testing complete as required.
Running test of EA set on load for 1 Hr by providing required diesel & making connections properly on both ends of EA set etc.complete as reqd
Replacement of following faulty items in existing LT panels etc. i/c connection, testing etc. complete as required. (a ) 63 Amp TPN SFU (HPL)
(b ) 32 Amp TPN SFU
(c ) 63 Amp HRC fuse
(d ) 32 Amp HRC fuse
(e ) 63 Amp Changeover
Refilling of existing 4.5 Kg fire extinguisher i/c pressure testing etc complete as reqd.
Replacement of damaged Hose & horn pipe on existing fire extinguisher etc complete as reqd.
S/F of electronic battery charger for charging of starting battery of DG set on UPPCL supply i/c connection testing etc. complete as reqd.
Wiring of control wiring & making arrangement for starting with starting key panel i/c connetion testing etc as reqd.
Replacement of solenoid switch i/c connetion testing etc as reqd.
Supplying and fixing of 3 feet x 2 feet size glow sign board made of metalic base and acrylic front sheet and printed with "BSNL" with one logo of BSNL and glowing arrangement with 2 feet size LED tubes i/c on-off switch, connection, testing etc complete as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .