Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹13.3 L+₹11,812 (0.89%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹13.5 L+₹24,538 (1.86%)Rejected-Finance 6 STATION ROAD BERHAMPORE MURSHIDABAD WEST BENGAL 742101 | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹26,444
Closing Date
25 Sept 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PWDte
Bankura
Supply , Delivery and Installation of Hi Wall Split Air-Condition Machine (1.5/2.0 TR) with allied EI Work at On Duty room for EMOs, PGTs, SRs, RMOs, Ground floor of Emergency Building under BMC and H , Bankura.
2024_WBPWD_752560_1
WBPWDTE/EE/BED/NIQ_111/Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
Bankura Sammilani Medical College
Please refer Tender documents.
3 documents required · 3 mandatory
₹26,444
27 Sept 2024
17 Sept 2024
27 Sept 2024
18 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Supplying and fixing double door Horizontal TPNMCB Distribution board with IP-42/4 protection, concealed inwall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make-Legrand/Siemens/Schneider/ Crabtree) 6 Way
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for VTPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment Make-Legrand/ Siemens as to GS 6 way
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. 6A - 32A SP MCB
Supplying of 1.1 KV Grade following sizes Al. Armoured PVC/ XLPE Cable ( Make : Havells/ Glostar/ KEI/PWD Approved ) as per direction of EIC 4 x 35 sq mm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in 20 / 25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 4 sqmm + 1 x 2.5sqmm ( For AC Machine )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 2.5 sq mm
Supply and delivery of Non inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required : 18000 BTU / Hr. or Higher (b) Minimum Star rating- 2 Star or higher (c) Rated voltage—230V +/-5%, Frequency-50Hz. (d) Compressor type- Rotary. (e) Mini. Room Discharge air flow rate - 620 CFM or higher f) Condencer tupe -Copper condencer coil g) Minimum Tonnage required : 1.5T or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernize provision of temperature setting, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement and others.Incl. delivery charges. ( Make:- Mitshubishi Electric Model- MS/MU- GK18VA /O-General Model - ASGA18BMWA-B / Mitshubhisi Heavy Industries)
Supply and delivery of Non-inverter wall mounted SPLIT room air conditioner having the following major specification:- (a) Minimum Cooling capacity required : 24000 BTU / Hr. or Higher (b) Minimum Star rating-2 Star or higher (c) Rated voltage—230v +/-5%, Frequency-50Hz. (d) Compressor type-Rotary. (e) Mini. Room Discharge air flow rate- 650 CFM or higher f) Condenser tube -Copper condenser coil g) Minimum Tonnage required: 2 TR or higher h) Refrigarent- R32/R410A i) Cordless Remote arrangement with all modernized provision of temperature settings, Fan speed option(low/medium/high), Auto swing, Air direction setting, Timer facility, Turbo operation setting, Air ventilation arrangement, and others.Incl. delivery charges. ( Make:- Mitsubishi Electric Model- MS/MU- GK24VA /O-General Model - ASGA24BMWA-B / Mitshubhisi Heavy Industries)
Supply and Delivery of Timer DB 1) 230V, Upto 16 A capacity 24 Hrs Analog Electromechanical Time Switch(Make-(L&T-(L&T-AUTS03ANA00/Legrand/ABB) 2) 2 Pole Power Contrcator (L&T-MNX 22-2P Cat No-CS90238/Legrand/ABB)----- 01 Nos 3) 16A/20A SP MCB. ----- 01 Nos (Legrand/ABB/Siemens) 4) 32A DP Isolator.---- 01 Nos (Legrand/ABB/Siemens) 5) Toggle Switch. ----01 Nos (Make- L&T or equivalent make) 5) (2+12 Way) SPNDB (Legrand/ABB/Siemens)----- 01 Nos Suitable Size Copper Stranded Wire. 7) Green LED Indicator 6) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power. 7) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / ABB )
Supply & Fixing of 250V 50 HZ OLP- 21A single phase A.C Starter ( Make -Electron, / PWD Appvd ) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply, Installation & commissioning of (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (Make-Ryoku/Rajco/Nippon) with 9 mm nitrile rubber tube Insulation on the following sizes of the suction line & Liquid Line copper pipe with proper insulation tape (Make-Accoflex/ Armacell/K-Flex) with max saddling with max 1-meter distance both for suction & discharge pipe complete with fittings, elbows, bends, and supporting arrangements on walls.
S& Laying 3 core 2.5 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
MAXCOOL REFRIGERATION CO. (BID ID -5599652)
JASODA REFRIGERATOR SERVICING CENTRE (BID ID -5600987)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .