Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 CrAccepted-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹11.2 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹12.2 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹12.2 Cr | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹12.7 CrRejected-Finance 208 2ND FLOOR EXPRESS MARKET AMBEDKAR ROAD GHAZIABAD 201001 UP | GHAZIABAD | UTTAR PRADESH | 201001 | ₹12.7 Cr | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹12.9 CrRejected-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹12.9 Cr | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹13.5 CrRejected-Finance | ₹13.5 Cr | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹10 Cr
EMD Value
₹8.3 L
Closing Date
27 Jan 2022, 6:00 pmClosed
Chief Engineer Bathinda
HQ Chief Engineer Bathinda Zone, Bathinda Military Station
PROVISION OF SWIMMING POOL AT BIKANER MIL STN
2021_MES_478880_2
CA NO CEBTZ/BKN/TOKEN-13 of 2021-22
Open Tender
Civil Works
546 days
Bikaner Mil Stn
As per NIT
8 documents required · 8 mandatory
₹3,000
GE P Bikaner
₹8.3 L
Yes
26 Mar 2022
17 Dec 2021
29 Jan 2022
17 Dec 2021
27 Jan 2022
7 Jan 2022
Amount
Sch 'A' Sec - I, ( BUILDING/STRUCTURE WORK)
Lump sum price worked out by the Contractor for **Rs. ______________ “Building Work / Structure Work” as listed in Schedule ‘A’ Section - I Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section I
Sch 'A' Sec - II ( Part-I) (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “Internal Electrification” as listed in Schedule ‘A’ Section - II (Part-I) Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section II (Part-I)
Sch 'A' Sec - II ( Part-II) (INTERNAL ELECTRIFICATION WORKS)
M&L for Point wiring complete with 1.5 sqmm (Nominal cross sectional area) PVC insulated flame retardant low smoke un-sheathed and multistranded copper conductor cable with colour code ISI marked and including rigid non metallic PVC medium grade concealed conduit ISI marked and conduit fittings for one light point/fan point /engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable GI sunken box of suitable size and covered with & including 3 mm thick bakelite laminated sheet (ISI marked) top cover etc complete all as specified and directed. (Cost of GI sunken box and bakelite sheet included in the rate)
All as per Srl No.6.00 here-in-before but one three pin switch socket outlet 5 Amps on the independant board.
M&L Point wiring complete with 2.5 sqmm (Nominal area) PVC insulated flame retardant low smoke un-sheathed and multistranded copper conductor cable ISI marked in and including rigid non metallic PVC medium grade concealed conduit medium quality and conduit fitting for 3 pin 15 Amp multipurpose switch socket combination including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connected to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc complete all as specified and directed.
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed FRLS multi-stranded copper conductor single core FRLS cable as earth continuity conductor to common earth and connected to earth dolly, & including GI terminal box with base frame and cover plate of required module (suitable for modular including switch/sockets ) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium grade concealed conduit all as specified.
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
NOTE FOR SERIAL ITEM 6 to 9.02: (a) Switch(es), socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) Terminal boxes shall be fixed flush to walls with cement & sand mortar (1:4) complete on the location as approved by EIC.
Supply and fixing LED lamp minimum 3 star rated 10 W LED Bulb B-22 base including lamp holder complete all as specified and directed by Engr-in-Charge with following specification:- (a) Lumen system efficacy of luminaries should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to plus 45° (d) Power factor : Minimum 0.90 (e) CRI : More than 80 as specified.
Wiring with TV coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a copper wire net for TV antenna from terminal boxes to TV socket complete all as specified (conduit pipe and fittings shall be measured and paid separately).
GI box flush mounted 100mm x100mmx100mm having holes for 20 mm conduit entry including 2 pin TV socket outlet flush type duly marked with symbol of TV and 3 mm thick plastic laminated sheet cover complete for TV connection all as specified.
Wiring with twin core PVC insulated sheathed cable with copper conductor having single strand of 0.6 mm dia taped for telephone wiring from terminal box to telephone socket complete all as specified (conduit and conduit accessories shall be measured and paid separately).
GI box flush mounted 100mm x100mmx100mm having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and 3 mm thick plastic laminated sheet cover complete for telephone connection all as specified.
Supply and hanging Ceiling fan 1200 mm sweep, AC supply, (input oltage 120 to 280 Volts) brushless direct current motor (BLDC), 5 Star rating, BEE & ISI marked super enamelled copper winding of 'B' class insulation, single phase 26 W ( + 10%), PF 0.90 (Min), air delivery of 220 Cum/ minute (CMM), 350 RPM ( + 10%), temperature rise 40 degree maximum, without remote, with electroniv regulator, 3 Blades, down rod including accessories, white colour, total harmonic less than 10 %, 5 speed, hanging in position including connection with and including flexible cord twin core twisted copper conductor of size 23/ 0.0076 from ceiling rose or connector to fan all as specified. NOTE:- Srl number of ceiling fan and GE's office name shall be writing on fan with Red colour permanent paint and cost is deemed to include in unit rate quoted. .
All as per item No.16 here-in-before including note but 380 mm sweep plastic body
Supply and fixing LED light complete fitting surface/recessed mounted including batten and T-8 Retro LED polycarbonate 1 x 20 Watt, approx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting complete fitting with all accessories and following specification all as directed by Engr - in Charge:- (a) Lumen system efficacy of luminaries should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) IP rating : IP -20 (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the make as of the luminaries. (J) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacture. (k) Surge protection minimum 2.5 KV (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time 50000 burning hrs (Average 10 to 12 hrs daily) equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply and fixing LED mirror light fitting 1 x 5 Watt, including LED lamp extruded polycarbonate environment friendly, including electric with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting complete fitting with all accessories and following specification all as directed by Engr - in Charge:- (a) Lumen system efficacy of luminaries should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to plus 45° (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) IP rating : IP -20 (g) CRCA pre coated housing with two coloured plastic end cap. (h) LED Driver of the make as of the luminaries. (j) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacture. (k) Surge protection minimum 2.5 KV (l) CCT : 6500K (m) CRI : More than 80 (n) Rated life time 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing energy efficient LED street light fitting of 1 X 25 watt pressure die cast alumunium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminare, with driver, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting complete fitting with all accessories and following specification all as directed by Engr - in Charge:- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) IP rating : IP -66 (g) IK rating : IK07 (h) CRCA pre coated housing with two coloured plastic end cap. (j) LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacture. (l) Surge protection minimum 10 KV (inbuilt + extended) (m) CCT : 5700K (m) CRI : Minimum 70 (n) Lens: High efficiency wide angle lens (o) BIS approved fixtures and driver (p) Rated life time 50000 burning hrs (Average 10 to 12 hrs daily)
Note for item No – 10, 18 to 20 (a) Contractor shall submit LM - 79 and LM - 80 reports obtain from manufactures . (b) Contractor shall to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced including taking down and re-fixing new luminary free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in luminary (or Lux at 1 mtr) below 90% of claimed values of lumens (or Lux at 1 mtr) of the LED luminaries. (c) All LED light/luminary must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Minor items required for completion of job are included in overall cost quoted by Contractor. Nothing extra shall be payable on this account.
Rigid non metallic, 20mm bore PVC concealed conduit, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main, TV & telephone wiring and the like complete.
RCBO, 16 Amp, 300mA, TPN, type confirming to IS, suitable 415 volts, AC supply, breaking capacity not less than 10 kA, , complete all as specified.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 16 Amp complete all as specified.
Blanking plate of plastic and fixed in location (Suitable for distribution board)
Subtotal
Sch 'A' Sec - III (Part-I) (Internal Water Supply)
Lump sum price worked out by the Contractor for **Rs. ______________ “Internal Water Supply" as listed in Schedule ‘A’ Section - III(Part-I) Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section III(Part-I).
Sch 'A' Sec - III (Part-II) (Internal Water Supply)
Bib tap, small body, cast copper alloy, chromium plated fancy type with quarter turn handle, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete all as specified.
Bib tap, long body, cast copper alloy, chromium plated fancy type with quarter turn handle, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, complete all as specified.
Spreader for urinal, cast copper alloy chromium plated, fancy type suitable for 15mm bore, high pressure with crutch handle screwed down, boh ends screwed for iron pipe o for unions and fixed complete all as specified.
Subtotal
Sch 'A' Sec - IV, (Part-I) (Sewage Disposal Work)
Lump sum price worked out by the Contractor for **Rs. ______________ “Sewage Disposal Work" as listed in Schedule ‘A’ Section - IV (Part-I) Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section IV (Part-I).
Sch 'A' Sec - IV, (Part-II) (Sewage Disposal Work)
DWCPE (SN8) confirming to IS-16098, 150 mm nominal bore complete laid in trenches and jointed including testing with and including necessary jointing material tees/ union/ socket etc complete as per manufacturers instructions. NOTES:- (i) Earth work shall be measured & paid for separately under respective items of Schedule 'A'/BoQ. (ii) The rate of necessary tees/ union/ socket/ other accessories of same material and size of pipe is included in this item and nothing shall be paid extra on this account.
Subtotal
Sch 'A' Sec - V, (Part-I) (Road Work)
Lump sum price worked out by the Contractor for **Rs. ______________ “Road Work" as listed in Schedule ‘A’ Section - V(Part-I), Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section V(Part-I).
Sch 'A' Sec - V, (Part-II) (Road Work)
Thermo plastic road marking 2 mm thick painting (lines, dashes, arrow, letters etc on new road surfaces) with road safety spikeries glass beads including preparation of new road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed .
Jodhpur stone slab edging 7.5 cm thick to 10 cm thick , 30-35 cm wide and 30-45 cm long, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6 mm for top and exposed surfaces of sides and 20 mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush, including necessary earth work, embedding to depth as required and tamping around edging and removal of surplus spoil to a distance not exceeding 50 mtr and deposited as directed complete all as specified.
Subtotal
Sch 'A' Sec - VI, (Part-I) (SIDE WALK, PATH AND CULVERT WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “ Path and Culvert Work" as listed in Schedule ‘A’ Section - VI, (Part-I) , Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section VI).
Sch 'A' Sec - VI, (Part-II) (SIDE WALK, PATH AND CULVERT WORKS)
Endura anti skid tiles 300 x 300 x 9 to 10mm thick, set, jointed in neat cement slurry and pointed in white/ colour cement to match the colour of tile in floors complete all as directed and specified.
Subtotal
Sch 'A' Sec - VII ( Part-I) (AREA DRAINAGE AND SURFACE DRAIN WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “AREA DRAINAGE WORKS" as listed in Schedule ‘A’ Section - VII , Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section VII).
Sch 'A' Sec - VII ( Part-II) (AREA DRAINAGE AND SURFACE DRAIN WORKS)
300 mm wide PVC grating as drain cover all as specified
Subtotal
Sch 'A' Sec - VIII (SECURITY FENCING WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “SECURITY FENCING WORKS" as listed in Schedule ‘A’ Section - VIII , Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section VIII).
Sch 'A' Sec -IX (COMPOUND WALL WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “COMPOUND WALL WORKS" as listed in Schedule ‘A’ Section - IX , Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section IX).
Sch 'A' Sec - X (Part-I), (External Water Supply and Filtration Plant works)
Lump sum price worked out by the Contractor for **Rs. ______________ “External Water Supply and Filtration Plant works” as listed in Schedule ‘A’ Section - X (Part-I), Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Sec - X (Part-I) .
Sch 'A' Sec - X (Part-II), (External Water Supply and Filtration Plant works)
Making connection by cutting existing CI/DI main 450 mm dia under ground pipe for inserting of tee 450mm x 450mm x 100mm and CI collar incuding necessary earth work complete all as specified. Note :- CI/DI fittings, jointing material, Tee 450mm x 450mm x100mm and CI collar shall be measured and paid seperately under respective items of BOQ.
CI/ DI fittings upto 450mm bore pipe line for reducing/bends (any type radius and angle) tapers of any type ( straight, bend, increasing, decreasing or double socket extra), Tee pieces single branch 'Y' Junction, double branch, cross ( all sockets or socket and spigot), collars, caps, plugs etc complete all as specified.( Cost of joints including jointing material shall be deemed included in unit rate quoted by the tenderer. )
Ductile Iron pressure pipe 100 mm bore with spigot and socketed ends centrifugally cast, Class K-9, conforming to IS: 8329/2000 - blast furnace slag cement with portland cement properties suitable for push-on-jointing (Rubber tyton joints) with inside cement mortar lining with internal metallic zinc coating and external Black Bitumen coating complete all as specified and as directed by Engr-in-charge. Note:- Cost of joints including jointing material shall be deemed included in unit rate quoted by the tenderer. Earth work & DI specials/ fittings shall be measured & paid separately.
100 mm bore sluice valve,ISI marked PN 1.6 conforming to IS-14846-2000 both end flanged, drilled, gunmetal spindle and iron wheel handle, CI gate with brass ring complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and directed.
100mm bore cast iron non return valve, ISI marked confirming to IS-5312-2004 both end flanged drilled complete with CI plate including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and directed.
Supply, Installation, Testing and commissioning of water Filtration cum recycle plant for Swimming Pool complete with following:- (a) TOTALLY ANTI-CORROSIVE Bobbin Wound Multi Grade sand filter including Valve Battery Manifold made in PVC with flanges for connecting to filters as per DIN 2501 standards complete with one set of butterfly valves of 150mm size as per design of manufacturer for carrying out filtration, back-washing, rinsing and shut down of the filters. Valves should be suitable for working pressure of 2.5 Kg/cm2 and Test Pressure 3.5 kg/cm2 and should conform EN ISO 9001 :2000 Standard. Filter should be supplied with all standard fitting and accessories as per designated of official products of FINA with certificate. Filters should be complete with following:- (i) Back wash arrangement shall be made to facilitate the back washing system. (ii) Pressure gauge lot as recommended by manufacturer of filter plant. (iii) Air vent system with gun metal valve. (iv) Pressure relief valve. (v) Suitable size of man and hand hole.
Item No 72 Contd… (vi) Filter Flow Rate - 150 m3/Hr. (vii) Filtration Velocity - 40 m3/Hr/m2. (viii) Vessel Dia - 2200 mm. (ix) HOS - 2390 mm Make-Astral/Hayward/Leisure Pool/Tech Pool Note:- (i) Drawing for filtration plant layout shall be approved by GE before placing order. (ii) Colour coding of pipes lines, arrow marking and numbering of valves shall be done as per IS Code.
Supply and fixing uPVC pressure pipes of following sizes Class - 5 (10kg/cm2) with plain socket suitable for and including solvent cement jointing conforming to IS: 4985/2000 complete with fitting and specials such as bends, tees, unions, reducers, flanges and plugs etc complete. Make:- Astral/ Hayward/ Leisure Pool/ Tech Pool Note : The pipes and fittings shall be tested to pressure of 10 Kg/Sqcm.
63 mm bore
150 mm bore
160 mm bore
200 mm bore
250 mm bore
300 mm bore
Supply and fixing water type cast iron butterfly valves of the following sizes tested to 10 kg/sq.cm pressure (including flanges & All other accessories) complete all as specified and directed. Make :- Zoloto/ Leader/ Venus
63 mm bore
150 mm bore
200 mm bore
250 mm bore
Supply and fixing of 200mm bore CI dual plate Check Valve (PN 20) complete with matching flanges rubber insertion sheet, nuts, bolts and washer etc complete.Make :- Zoloto/ Leader/ Venus
Supply and fixing of following sizes of heavy duty PVC puddle flanges of suitable length and made of (uPVC pipe 10kg/cm2) complete with matching flanges including jointing material all as specified and directed. Make:- Supreme/ Astral/ Finolex/ Prince Note :- These flanges shall be suitably placed between steel reinforcement as per standard Engineering practice.
160 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for PVC heavy duty foot nozzles fitted vertically on the UPVC pipe 160mm bore on the bottom for the swimming pool and diving pool for filling the swimming pool and diving pool complete. Make:- Astral/ Hayward/ Leisure Pool/ Tech Pool/ ION EXCHANGE Note: All the nozzles shall be fixed as per swimming pool and driving pool water supply drawing or as per manufacturer recommendation.
Supply & fixing of ABS white plastic suction port/ vacuum nozzle suitable for and including solvent cement connection. Make-Astral/Haywards/Leisure poolTech Pool/ ION EXCHANGE
Supply & Installation, Testing and Commissioning of cast iron pump 3000 RPM complete with mechanical seal in stainless steel IP-54 motor protection stainless steel AISI-420 shaft with stainless steel AISI-316 strainer basket conn. PN 1.6 according to DIN 2501, voltage 400V/3 Ph (4 working and 1 standby) complete all as specified and directed and making electrical connection with control panel with and including copper cable of suitable size with following specification - (i) Discharge/Flow Rate - 150 m3/Hr. (Minimum). (ii) Head to suit the flow of filter plant or as recommended by filtration plant manufacturer but not less than 22 mtr. Make-Astral, Hayward, Leisure Pool, TechPoo/ ION EXCHANGE
Supply, Installation, Testing and Commissioning of UV system consisting of following:- UV system flow rate: 25.00 m³/h, dose: 11 MJ/cm², light power : 75W UVC equipment made using the latest technological design to ensure effective water flow through the unit, driving better UV light performance designed to bear pressure up to 4 bars, power consumption low, the whole of the electrical system protected so that water cannot enter and thermal element to prevent power surges, the UVC units distributed with two male threads of 1.5''/50mm, the product easy to install, each unit distributed with stainless steel anchoring fixtures for vertical or horizontal fastening and complete all as directed. Make-Astral / Leisure pool/Hayward/ Tech Pool/ ION EXCHANGE
Supply, installation, testing and commissioning of Automatic Membrane Dosing Pumps complete with chemical storage tank, Agitators and with following specifications:- (i) Dosing pumps:- Design, supply, installation, testing and commissioning automatic sensor based dosing pump sets including LCD screen on/off or proportional operation mode 0-14PH 1000-1400 MV, PH, RX (ORP) electrode inlet (10 tera OHM), including electrode screen resolution 0.01PH ( + ) 1 mv ph/ Rx 10 litre /hour -5 bar, IP-65 protection anti acid plastic casing, control panel protection weather proof and resisting UV rays, standard power supply 230V AC 50 HZ single phase with sensor. PH sensor kit including PH sensor buffer solution, sensor holder, level sensor including RX sensor, buffer solution, sensor holder, level sensor. (ii) Chemical storage tanks:- Semi transparent polyethylene tank with external scale so that levels can be checked easily capacity of tank 500Lts. (iii) Agitators:- Agitators for easy installation in the tanks, provided with steering grip in Bakelite, rod and propeller arms in PVC, length of stirring rod 900mm. Make-Astral, Haywards, Leisure Pool, TechPool/ ION EXCHANGE.
Supply of Trolley mounted suction sweeper kit, complete with motor pump & starter, mounted on trolley 3 feet long, along with heavy duty nylon brush size of 50 mm x 900 mm, complete all as specified and directed. (i) Trolley made of MS painted with wheels for smooth movement around the deck. (ii) Including self priming, NONCLOG Trolley mounted suction SP Series pump motor capacity not less then 2 HP, 3 phase, AC, 50 Hz, Head range 9-23m, discharge range 6.2 LPS, ( Make Kirloskar, Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE all as specified and directed. (iii) Float complete to support the hose, clips for connection - 10 Nos
Supply, Installation, testing and commissioning of filter header system of 400 mm bore made of Stainless Steel Pipe 304 grade suitable for pumping sets and filtration plant including cutting, welding and making provision for different pipe connection e.g Circulation pump suction line, filter valve assly, Inlet connection with all necessary fitting, flanges, Nut bolts, gasket as required to complete the job as per filtration plant/pump set manufactures recommendation and all as directed.
Supply, installation, testing and commissioning of GI perforated Cable Tray 150 mm wide all as specified and directed.
Supply, installation, testing and commissioning of GI perforated Cable Tray 200 mm wide all as specified and directed.
Supply, installation, testing and commissioning of GI perforated Cable Tray 300 mm wide all as specified and directed.
Supply, installation, testing and commissioning of MS Structure work made out of Angle, Fastners, Tie Rods, flat for pipe support and pump footing, all as specified and directed. Note : All MS work to be painted with 02 coats of synthetic enamel paint over a coat of red oxide primer.
Supply and fix anodised Extruded Stainless Steel Vacuum Head - 900 mm Stainless steel grade -304 fixed with clip type connection 1- 1/2" , maintenance kit complete all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool., ION EXCHANGE
Supply only reinforced telescopic Handle 3.6 - 7.2 mtr long all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply only floating suction made of polyethylene blue colour 40 mm ( 1- 1/2" ) 30 mtrs long all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply only deep bag skimmer clip type all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPoo, ION EXCHANGE
Supply only water surface skimmer clip type all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPoo, ION EXCHANGE.
Supply only curved brush clip type all specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply only test kit for pH and chlorine all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool.
Supply only Algae Brush stainless steel Bristle all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply only straight brush clip all as specified and directed. Make-Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply only of calcium based high strength sodium hypo chloride for water disinfectant as granular from in factory sealed HDPE container (45 to 50 Kg each) having chlorine concentration level not less than 65%. All as specified and as directed. Make-Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply only of Trichloroisocyanuric acid TCCA - 90 (Swimming pool treatment compound) in granular from having concentration 90 % in factory seated HDPE container of 45/50 kg each. Make : Astral, Haywards, Leisure Pool, TechPool, ION EXCHANGE
Supply and fixing PVC insulated copper conductor, single core cable 4 x 6 sq mm complete all as specified and directed.
Supply only Alum crystal free from impurity class I suitable for swimming pools complete all as specified and directed.
Supply and Fix CI Foot Valve ISI marked, flanged type, suitable for 200 mm bore pipe including jointing material such as nuts, bolts, washers, gasket etc complete all as specified and directed.
Construction of brick masonary valve pit chamber size 45 X45 X70 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning filling, disposal of surplus soil to a distance not exceeding 50 mtr & depoisted where directed, PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-1 using 12.5 mm graded stone aggregate, brick wirk in cement mortar 1:4, inner plaster 12 mm thick in CM 1:4 finished even & smooth without usin extra cement & pointing lus externally as the work proceeds in same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of primer red oxide complete all as specified and directed.
Construction of brick masonary valve pit chamber size 100 X100 X100 cm (internal dimension)using sub class 'B' bricks complete including excavation & earth work, returning filling, disposal of surplus soil to a distance not exceeding 50 mtr & depoisted where directed, PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-1 using 12.5 mm graded stone aggregate, brick wirk in cement mortar 1:4, inner plaster 12 mm thick in CM 1:4 finished even & smooth without usin extra cement & pointing lus externally as the work proceeds in same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of primer red oxide complete all as specified and directed.
Construction of brick masonary valve pit chamber size 150 X150 X150 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning filling, disposal of surplus soil to a distance not exceeding 50 mtr & depoisted where directed, PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC 1:2:4 type B-1 using 12.5 mm graded stone aggregate, brick wirk in cement mortar 1:4, inner plaster 12 mm thick in CM 1:4 finished even & smooth without usin extra cement & pointing lus externally as the work proceeds in same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of primer red oxide complete all as specified and directed.
Subtotal
Sch 'A' Sec - XI (Part-I), (External Electric Supply Works)
Lump sum price worked out by the Contractor for **Rs. ______________ “External Water Supply Works” as listed in Schedule ‘A’ Section - XI (Part-I)Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Sec - XI (Part-I) .
Sch 'A' Sec - XI (Part-II), (External Electric Supply Works)
Supply and fix time switches astro type( Having longitude and latitude of Indian cities in memory) 250V single phase of 32 Amp rating with contactor fitted inside steel enclosure.
Cable route / path indicators made out of 40x40x4mm angle iron 1.2 mtr long and plate of size 100x150x6mm welded only on one side end having embossed on plate as cable HT including PCC 1:4:8 of size 30cmx30cmx 30cm duly embedded the angle iron in PCC including excavation / earth work complete all as specified and directed.
Making hole using treanch less technology under road or hard standing suitable for laying and inserting pipe upto 100 mm bore, any length by mechanical drill system and making the surface good as per existing completer all as specified.
Supply, installing, commissioning and testing LT panel board ( Out door type) with power factor capacitor bank factory made (CPRI approved) fabricated, suitable for 415 volt, 3 phase, 4 wire 50 Hz AC supply, cubical type, dust & vermin proof (Kiosk type), made out of CRCA sheet 3.15 mm thick except inner sheath. Frame and legs shall be made of 50 x 50 x 6 mm size angle. Vertical height of legs shall be not less than 45 cm from top of PCC floor finish. Legs shall be grouted in PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate). The dimensions/size of the LT Panel shall be as on required basis for incorporating the electrical accessories / components as specified following. The front and back side of the LT Panel shall be provided with hinged double doors with locking arrangement. The locks shall be built in flush type of superior quality as directed by Engineer in Charge. The hinged shall be of such construction that the door can swung open by not less than 150 degree. The fixing of the doors shall be such that the doors should automatically come to closed position if not kept open with effort. The panel shall be designed in such a way so as to have independent compartments /cabins for housing MCCB’s, cable gallery, bus bar chamber with aluminium busbar of capacity 300 Amps, TPN, three phase, 4 wires, switch and other accessories. Panel shall be painted with anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) all s specified in relevant IS. and consisting of the following :- (a) Incoming MCCB 4 pole 200 Amps, 35 KA . With adjustable thermalmegnetic release type and extension links. – 01 No. (b) Out going MCCB 4 pole 160Amps, 25 KA . With adjustable thermalmegnetic release type and extension links. – 01 No.
Item No 113.00 (Contd...) (iv) Wiring of complete panel board with suitable size of copper wire and copper thimbles, complete with number sleeves markers. (v) Power cable copper conductor cable of suitable size complete with thimbles. (vi) Microprocessor based automatic power factor control relay unit suitable for number of stages of capacitor bank mentioned below in Schedule. . The processor shall have following features:- (i) Suitable for programming at site. (ii) Over/under voltage trip point +/-10% (iii) Self adjusting switching sequence. (iv) PF adjusting range upto 1.00 (v) 50 Hz frequency 433 volts 3 phase system. (vi) Single phase prevention of capacitors. (vii) Indication for operational state of capacitors LED type. (viii) No of transformer required – 02 Nos.
Supply & Fixing and testing Junction box of size 200 x160x 98 mm or 200 x 140 x 95 mm or any other higher size made out of poly carbonate with glass fiber reinforced material having IP 66 protection in accordance with IEC 60529 fixing with and including clamp made out of MS flat iron 25 x 3 mm including painting to MS clamp, nuts, bolts with two coats of aluminium paint over a coat of red oxide primer complete comprising of the following:- (i) Junction box shall meet the provn laid down in IEC 60998-1, IEC 60670-22, IEC 60670 - 2 to 5 and colour according RAL 9011. (ii) The manufactuerer of junction box shall submit copy of IEC certificate. (iii) Junction box shall be fire retardant and self extinguishing in accordance with IEC 60695-2 to 11, DIN VDE 0304 Part-3, UL 94 V-2 flammability standard. It shold be tested at Glove wire test for 960 Degree C . (iv) Th degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for IK08. (v) Internally embedded gasket of polyurethance. (vi) Junction box shall be 4P with SP MCB ‘C’ curve of 6 Amp rating
Supply and fixing of energy efficient LED street light fitting with LED lamp of 100W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection using 1100 Volts grade FRLS, PVC insulated standard copper conductor cable PVC sheathed 2.5 Sqmm flat or circular twin core cable, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : More than 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) (p) bracket made out of 40 mm bore light grade GI pipe at 120 degree angle with help of suitable CI clamps including nuts, bolts, washers etc
Supply and fixing of energy efficient LED street light fitting with LED lamp of 72W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection using 1100 Volts grade FRLS, PVC insulated standard copper conductor cable PVC sheathed 2.5 Sqmm flat or circular twin core cable, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : More than 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) (p) bracket made out of 40 mm bore light grade GI pipe at 120 degree angle with help of suitable CI clamps including nuts, bolts, washers etc
Supply and fixing of LED Post top light fitting with LED lamp of 25 watt, decorative design, Glare-free and better uniformity, complete fitting with all accessories and LED lamp, fixing on GI pipe pipe 50 mm dia medium grade as directed by Engineer-in-charge including making electric connections using 1100 Volts grade FRLS, PVC insulated standard copper conductor cable PVC sheathed 2.5 Sqmm flat or circular twin core cable, complete all as specified and as directed by Engineer-in-charge and as per the following specifications:- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : More than 70 and CCT : 5700 K. (g) IP rating : IP65. (h) IK rating : Minimum IK07 (j) Pressure die cast aluminium alloy housing and front cover clear toughned glass (k) Built in potted LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection 10 kV (inbuilt + extended) (n) Lens - High Efficiency wide angle lens. (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Notes for item No. 115 to 117 (a) Contractor shall submit LM-79 and LM - 80 reports obtained from manufacturers (refer Sch A' note ). (b) Contractor shall to furnish a Replacement warranty from manufacturer of five years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced including taking down and refixing new luminaire free of cost in the following cases:- (i) Manfacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or Lux at 1m) below 90% of clamied values of lumens (or lux at 1m) of the LED/Luminaries.
Notes for item No. 115 to 117 (Contd...) :- (c) All LED light/luminare must meet the provisions laid down in IS -16101, 16102 Part - I/II , 16103 Part -I, 16104,16105, 16106, 16108/2012 and 15885 Part-II Section 13. (d) Minor items required for completion of job are included in overall cost quoted by Contractor. Nothing extra shall be payable on this account.
Local tibba sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR-Part-1 before laying of cable and 150mm thick after laying of cable and punned down to 180mm after laying complete. Note:- Punned thickness shall be considered for payment purpose.
Installation and commissioning of 11/0.433KV upto 160 KLVA transformers with and including dehydration and top up transformer oil upto the appropriate level with standard dielectric strength including handling and transporting of transformer from store yard to proposed site of work. Note:- (i) Transformer shall be issued by the department out of existing holding free for fixing. (ii) All T & P/ vehicle and manpower for loading, unloading and transporting of transformer shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted. (iii) Cost of transformer oil upto 10 litre required for top up shall be deemed to be included in the unit rate quoted.
Subtotal
Sch 'A' Sec - XII (Part-I), (SUMMER COOLING APPLIANCES WORKS)
Lump sum price worked out by the Contractor for **Rs. ______________ “SUMMER COOLING APPLIANCES WORKS” as listed in Schedule ‘A’ Section - XII (Part-I)Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Sec - XII (Part-I) .
Sch 'A' Sec - XII (Part-II), (SUMMER COOLING APPLIANCES WORKS)
Supply, install , commissioning of Water cooler fully stainless steel, electric driven single phase having storage capacity 60 litre and nominal cooling capacity 120 litre per hour mounted on locatiion as directed complete including connecting and making water and electric connection complete.
Supply, install , commissioning of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 1KVA with mounting bracket complete with time delay relay. complete all as specified .
Subtotal
Sch 'A' Sec - XIII, (Site clearance, Earth Work and Development of land works)
Lump sum price worked out by the Contractor for **Rs. ______________ “Site clearance, Earth Work and Development of land works" as listed in Schedule ‘A’ Section - XIII Representing ** _______ % ____________ percent *Above / Below the lump sum price on col 5 inserted by the MES in Schedule ‘A’ Section XIII.
JASRAJ AND COMPANY
VADERAS INTERIORS AND EXTERIORS
M/s R L PAREEK
Jagdish Prashad and Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid