| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹5.6 L+₹63,767 (12.9%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹6.1 L+₹1.2 L (23.8%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹6.3 L+₹1.3 L (26.8%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹7.1 L+₹2.1 L (42.8%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
25 Jan 2025, 6:00 pmClosed
CWE(AF) BAMRAULI
HQ CWE(AF) BAMRAULI PRAYAGRAJ 211012
REPAIR/MAINT TO INTERNAL ELECTRIFICATION ALONGWITH FITTINGS,FIXTURES AND DISTRIBUTION BOARDS IN OTM ACCN AT MILITARY STATION GORAKHPUR
2024_MES_690546_1
87486/C/E8
Open Tender
Civil Works
Item Rate
182 days
GE(AF) GORAKHPUR
MES Enlisted Contractor of Class E category b i
7 documents required · 7 mandatory
₹500
GE(AF) GORAKHPUR
₹16,000
Yes
3 Feb 2025
26 Dec 2024
29 Jan 2025
26 Dec 2024
25 Jan 2025
11 Jan 2025
26 Dec 2024 - 2 Jan 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit including making good disturbed surfaces of walls, floors etc to match with the existing complete all as specified and as directed.
M&L point wiring with single core FRLSH PVC sheathed multi stranded copper conductor of size 1.5 Sqmm drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size ,mild steel terminal box made out of 1.6mm thick mild steel sheet with brass screws for mounting switchs, sockets,regulators etc including 1.5 Sqmm FRLSH PVC sheathed stranded copper conductor cable as continuous earth wire and connected to main earth dolly complete all as specified and directed for one light/Fan/exhaust fan point/ bell point controlled by one Switch
Description same as per item No 2 above but for 3 pin 5 Amps socket out let on same board complete all as specified and as directed.
Description same as per item No 2 above but for 3 pin 5 Amps socket out let on independent board complete all as specified and as directed.
Description same as per item No 2 above but for one power point 3/5 pin 15 Amps socket out let independent board using 2.5 Sqmm multi stranded FRLSH PVC insulated copper conductor cable with 2.5 Sqmm multi stranded FRLSH PVC insulated copper conductor cable as earth wire complete all as specified and as directed.
M&L point wiring with single core FRLSH PVC sheathed multi stranded copper conductor of size 1.5 Sqmm drawn through and including PVC casin and caping ISI marked not less than 20mm wide with GI saddles GI screws, rawl plugs (concealed conduit wiring in walls and casing capping on ceiling or roof ) including Tee, Junction boxes and provision of 3 mm thick plastic laminated sheet cover of suitable size ,mild steel terminal box made out of 1.6mm thick mild steel sheet with brass screws for mounting switchs, sockets,regulators etc including 1.5 Sqmm FRLSH PVC sheathed stranded copper conductor cable as continuous earth wire and connected to main earth dolly complete all as specified and directed for one light/Fan/exhaust fan point/ bell point controlled by one Switch
Description same as per item No 6 above but for 3 pin 5 Amps socket out let on same board complete all as specified and as directed.
Description same as per item No 6 above but for 3 pin 5 Amps socket out let on independent board complete all as specified and as directed.
Description same as per item No 6 above but for one power point 3/5 pin 15 Amps socket out let independent board using 2.5 Sqmm multi stranded FRLSH PVC insulated copper conductor cable with 2.5 Sqmm multi stranded FRLSH PVC insulated copper conductor cable as earth wire complete all as specified and as directed.
S&F Switch piano ,flush type single pole, one way, 6 Amps, 230 V complete all as specified and as directed.
S&F socket outlet 2 in 1,3 Pin,6 Amp, 230 V complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 Pin, 6 & 16 Amps, 230 V complete all as specified and as directed.
S&F Switch piano flush type single pole, one way 16 Amps, 230 V complete all as specified and as directed.
S&F ceiling rose surface bakelite 63.5mm x 20mm complete all as specified and directed. Make : Anchor / Cona / Havells as approved
Taking down old unserviceable light fittings conventional type from wall or ceiling or any position and making good the disturbed surfaces to match with the existing complete all as specified and as directed.
S&F 20 watt LED light fitting engineering extruded aluminium batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with all accessories internally perwired and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make:- Havells cat part No LHEXAPP7PN1W020 or equivalent in Bajaj / CG/ Wipro as approved.
S&F recess mounting LED luminaire of size 2'x2' white 36 watt, 230 volts for ceiling with driver connector block etc complete with all accessories duly prewired and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make:- Havells cat part No LHEBAEP7IW1W036 or equivalent in Bajaj / CG/ Wipro as approved.
S&F recess mounting LED luminaire round shape 12 watt, 230 volts for ceiling with driver connector block etc complete with all accessories duly prewired and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Make:- Havells cat part No LHEAAHP7IL1W012 or equivalent in Bajaj / CG/ Wipro as approved.
S&F post top lantern LED type 20watt, 230 volts, AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. Make:- Havells cat part No LHFOAQE1NZ5K7X5 or equivalent in Bajaj / CG/ Wipro as approved.
S&F energy saving, die cast aluminium housing IP 65 protection, 50 W LED flood light fitting with high power LED as light source, 5000 lumen, 6500K complete fixed on wall/pole using 30mmx5mm flat iron clamps, nuts, bolts and washers as per site requirement complete all as specified and as directed.. Make:- Havells cat part No LEECNP7PB6J050 or equivalent in Bajaj / CG/ Wipro as approved.
Taking down old unserviceable sub main wiring of 2/3 runs of any sizes from any position including exisitng batten or conduit etc and making good disturbed surface of wall or ceiling etc complete all as specified and as directed.
S&F submain wiring with two single core 2.5 sqmm FRLSH PVC insulated multistrand copper conductor cable drawn in and including PVC casing caping not less than 20 mm wide, ISI marked with all fittings and fixing accessories and one single core 2.5 sqmm FRLSH PVC insulated multistrand copper conductor cable as continuous earth wire complete all as specified and as directed. Note:- Two run of 2.5 sqmm copper cable,one run of PVC casing caping and one run of 2.5 sqmm copper cable earth wire shall be measured as one unit.
S&F submain wiring with two single core 4 sqmm FRLSH PVC insulated multistrand copper conductor cable drawn in and including PVC casing caping not less than 20 mm wide, ISI marked with all fittings and fixing accessories and one single core 4 sqmm FRLSH PVC insulated multistrand copper conductor cable as continuous earth wire complete all as specified and as directed. Note:- Two run of4 sqmm copper cable,one run of PVC casing caping and one run of 4 sqmm copper cable earth wire shall be measured as one unit.
S&F submain wiring with two single core 6 sqmm FRLSH PVC insulated multistrand copper conductor cable drawn in and including PVC casing caping not less than 20 mm wide, ISI marked with all fittings and fixing accessories and one single core 6 sqmm FRLSH PVC insulated multistrand copper conductor cable as continuous earth wire complete all as specified and as directed. Note:- Two run of 6 sqmm copper cable,one run of PVC casing caping and one run of 6 sqmm copper cable earth wire shall be measured as one unit.
Taking down unserviceable distribution boards any type/size disconnecting and making good to disturbed surfaces to match with the existing complete all as specified and as directed.
S&F factory made epoxy powder coated distribution board TPN, 4 ways, double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and as directed. Make :-Indo asian Havells/Legrand as approved
S&F factory made epoxy powder coated distribution board SPN, 12 ways ,double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates complete all as specified and as directed. Make :-Indo asian Havells/Legrand as approved
S&F factory made epoxy powder coated distribution board SPN, 8 way ,double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates complete all as specified and as directed. Make :-Indo asian Havells/Legrand as approved
S&F factory made epoxy powder coated distribution board SPN ,4 way, double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates complete all as specified and as directed. Make :-Indo asian Havells/Legrand as approved
S&F 100 Amp MCCB, 4 pole, 16 KA current rating with adjustable thermal and magnetic setting to be fixed in distribution board complete all as specified and as directed.
S&F 125 Amp MCCB, 4 pole, 16 KA current rating with adjustable thermal and magnetic setting to be fixed in distribution board complete all as specified and as directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and as directed.
S&F MCB, SP, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and as directed.
S&F MCB, SPN, 40 to 63 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutters, single phase 230 volt, AC 300mm sweep including connection with copper flexible wire of suitable size complete all as specified and as directed. Make:- Havells/Bajaj/CG as approved.
S&F in replacement exhaust fan, steel body AC single phase 230 volt, 300mm sweep with blades, frame and louversincluding connection with copper flexible wire of suitable size complete all as specified and as directed. Make:- Havells/Bajaj/CG as approved.
S&F in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and as directed. Note :-Old unserviceable ceiling fans shall be deposited in MES store yard.
Disconnecting, taking down carefully the existing exhaust fans of any description, any sweep and from any position for repairs/servicing, dismantling an opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling and greasing, fixing the serviceable parts in position, removing and replacement of defective/ unserviceable parts with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging/fixing the repaired fans in position, connecting and testing at site to the entire satisfaction of Engineer-in-charge complete all as specified and as directed. Note:- (i) Rewinding shall be measured and paid separately under respective item. (ii) The rates quoted is inclusive of transportation charges from E/M store yard to workshop and vice versa.
Rewinding of motor of exhaust fans of 225/250 mm sweep of any description with appropriate size of super enameled copper wire approx 170 gram including insulating material such as leatherized paper, cotton tape, glass sleev, insulating varnish etc testing at workshop complete all as specified and as directed. Make of winding wire:- Atlas/Finolex/ Devi Dayal as approved.
Rewinding of motor of exhaust fans of 300/400 mm sweep of any description with appropriate size of super enameled copper wire approx 200 gram including insulating material such as leatherized paper, cotton tape, glass sleev, insulating varnish etc testing at workshop complete all as specified and as directed. Make of winding wire:- Atlas/Finolex/ Devi Dayal as approved.
S&F 25 mm wide PVC casing caping , ISI marked complete all as specified and as directed.
S&F modular type PVC enclosure with a two pin and earth plug and socket 16 Amps complete with one single pole MCB 20 Amps capacity complete all as specified and directed.
S&F in replacment 4sqmm copper cable,single core,heat resistant flame retardant (HRFR), PVC Insulated Industrial flexible cable 1100 volts complete all as specifeid and directed.
S&F in replacment motor, single phase for 200/250mm Exhaust fan (as per sample) complete all as specified and as rected.
MK Enterprises (BID ID -3217711)
M/s A.K Construction (BID ID -3217614)
M/s R.S. Enterprises (BID ID -3223365)
Hindustan Power Corporation (BID ID -3217728)
M/S RAJEEV KUMAR (BID ID -3223279)
M/S SHAILZA TRADERS (BID ID -3217806)
Unitech India (BID ID -3217901)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .