| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC W 701 HARBHAJAN VIHAR AWHO SECTOR 14 SAS NAGAR MOHALI PB 140307 | S A S NAGAR | PUNJAB | 140307 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.3 L+₹2.6 L (6.58%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹42.4 L+₹3.6 L (9.30%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest | |
| 4 | L4₹43.1 L+₹4.3 L (11.1%)Rejected-Finance 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L4 | Rejected-Finance Not being Lowest | |
| 5 | L5₹43.3 L+₹4.5 L (11.6%)Rejected-Finance SCO 1 SECTOR 5 MANSA DEVI COMPLEX PANCHKULA HARYANA | PANCHKULA | HARYANA | 133301 | L5 | Rejected-Finance Not being Lowest |
Tender Value
₹48.3 L
EMD Value
₹96,600
Closing Date
23 Jan 2023, 6:00 pmClosed
GE Chandimandir
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-90/2022-2023 SPECIAL REPAIR TO BLDG NO P-715 AND PROVN OF TOILET AT CHANDIMANDIR
2022_MES_571076_1
GE/CHM-90/2022-2023
Open Tender
Civil Works
Item Rate
100 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹96,600
Yes
23 Jun 2023
24 Dec 2022
30 Jan 2023
24 Dec 2022
23 Jan 2023
9 Jan 2023
Amount
Taking down chowkats or frame not exc. 1.5 Sqm with shutters, without taking off shutters from the frame, complete all as specified and directed.
Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed.
Taking down cement plaster / terrazo of any description from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete, all as specified and directed.
Dismantling floor hearth or wall tilling including cement mortar bedding, complete as specified and directed.
Demolition of cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded or laid bedded pointed in any mortar, all as specified.
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, all as directed.
Taking down 100mm dia AC rain water pipes including all fittings , complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, all as directed.
Excavation in trenches in any type of soil, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier hole etc. and getting out, complete all as specified.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed.
Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed.
Sand filling under floors including watering and consolidation , all as specified.
Hard core of gauge of broken stone or boulders, not exc 63mm , deposited spread and lavelled in layers n-exc 25 cm watered & rammed to a true surface ,complete all as specified.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete, all as specified & directed.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete, all as specified & directed.
Brick work with fly ash brick of class 10 (min. compressive strength 100Kg/sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Brick work with sub class ‘B’ bricks of class 10 (min. compressive strength 100Kg/sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Brick work with fly ash bricks of class designation 10 (min. compressive strength 100Kg/sqcm) old size bricks, straight or curved on plan to any radius, in half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
Rendering 10mm thick in CM 1:3 on fair faces of concrete surfaces as in ceilings , finished fair and smooth, complete all as specified and directed.
Rendering 10mm thick in Cement and Sand mortar 1:6 over fair faces of brick/concrete surfaces ,finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work surfaces, finished even and fair in cement mortar (1:4), complete all as specified.
Rendering 15mm thick on other than fair faces of brick work surfaces, finished even and fair in cement mortar (1:4), inclunding using water proofing compound, complete all as specified. Note : WPC shall be measured and paid separately.
Dubbing out average 10mm thick on irregular face of walls /RCC surfaces in cement mortar (1:4), complete all as specified.
Supply only integral liquid water proofing compound (ISI Marked) complete all as specified & directed.
Machine cut Kota Stone Slab flooring, 18 to 22mm thick, best quality (minimum area of each slab not less than 0.30 Sqm) over and including cement screed bed 20mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab, cutting, rubbing, grinding and polishing (mirror finish) complete all as specified and directed.
Machine cut kota stone slab flooring 15-18mm thick (size matching the floor) , laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as in in skirting, dados, risers to steps, pillar etc, laid over and including 10mm screed layer in cement mortar 1:4, cutting, rubbing, grinding and polishing complete, all as specified.
Glazed ceramic coloured tiles of size 300mmx450mmx 7mm thick , set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10 mm thick bedding layer in CM 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed.
75mm thick PCC 1:4:8 type D-2 (using 40m graded crushed stone aggregate) as in sub base flooring, finished even ,all as specified and directed.
25mm thick PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in flooring, finished even and rough, all as specified and directed.
Factory made glazed / polished chequered cement concrete tiles 300mm x 300mm x 25mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Vitrified ceramic coloured tiles, area of each tile not exc. 0.36 Square metre , 10mm thick, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:6 , complete all as specified and directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) or PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed pipe, etc., and making good, cutting not exceeding 10cm girth, complete all as specified and directed.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over and including 1mm thick wall care putty, all as specified.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer , complete all as specified and directed.
Preparation of old surfaces of walls and applying two coats of oil bound distemper , complete all as specified and directed.
5mm thick tinted sheet glass in panels exc 0.50 Sqm in each pane including all fixing accessories, all as specified and directed.
4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square n.exc 0.5 Sqm in each panes complete, all as specified and directed.
4mm thick figured glass pin head type ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square n.exc 0.5 Sqm in each pane, complete all as specified and directed.
Solid PVC frame having profile 105mm x 60mm , single rebate, made out of solid PVC foam with homogenous fine cellular structure having density not less than750Kg/ cum, smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws , complete all as specified and directed. Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing mentioned on Srl Page No. 134, 135 and 146 of SSR Part-II including aluminum iron mongery.
Powder coated anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per site requirement and the directions of Engineer-in-charge.
Stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm , fixed with stainless steel wire staple/ wooden beads, complete all as specified.
Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and directed.
Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21, all as directed.
150mm long aluminum anodised handle, fabricated type, all as directed.
Aluminium, anodized barrel tower bolts of extruded section and fixed, 150mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified.
Stop valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions, complete all as specified .
Angle stop valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions, complete all as specified .
Bib tap, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions, complete all as specified .
Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 90gms), all as specified and directed.
Viterous china bowl urinal flat back, size of 465 x 355 x 265mm white (Minimum) with grating and union for discharge pipe including providing & fixing plugs, waste pipe , bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified & directed by Engineer-in-charge.
Vitreous china squatting pan "orissa" pattern, size 580 x 440 mm white, with integral foot rest (excluding flushing cistern and flush pipe) and connecting to trap, complete all as specified and directed .
Cast iron "P" or "S" trap, complete all as specified and directed.
Vitreous china, wash down water closet pan, white, pedestal pattern with ‘P’ or ‘S’ trap, (excluding, flushing cistern and flush pipe), complete all as specified and directed.
PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia CP flush pipe (long type for squatting pan), complete all as specified & directed.
Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings, framework of water tanks, framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc and similar work conforming to Fe.290.Gde-E-165, all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide, complete all as specified and directed.
Reinforced cement concrete, 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, all as specified.
Reinforced cement concrete, 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams etc, shelves and the like complete, all as specified and directed .
Mild steel TMT bars 10mm dia and over ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Mild steel TMT bars 6mm to 8mm dia ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , finished fair, all as specified.
Form work to flat surfaces of suspended slabs such as roof slab, floor slab, landing, shelves etc not exceeding 200mm thick, including edges in any position, rough finished surfaces, complete all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 , complete all as specified & directed by Engineer-in-Charge.
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
110 mm bore PVC (SWR) bends of any radius complete, all as specified and directed.
Steel water tubes, 15mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed.
Steel water tubes, 20mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified and directed.
PVC (SWR) pipe, 110mm bore, single socketed in any length with rubber ring joints fixed to walls/laid in floor/trenches including fixing arrangement, complete all as specified and directed.
PVC (SWR) pipe, 75mm bore, single socketed in any length with rubber ring joints fixed to walls/laid in floor/trenches including fixing arrangement, complete all as specified and directed.
110mm bore PVC (SWR) bends any radius ,complete all as specified and directed.
75mm bore PVC (SWR) bends any radius, complete all as specified and directed.
1000 Litres capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) triple layered , hoisted and fixed in position including PTMT ball valve 20mm bore with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm-210gms and PTMT tank nipple, etc, complete all as specified and directed.
Stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, all as directed.
2mm thick fibre glass reinforced translucent plain coloured sheeting with 2 corrugations side lap, fixed with coach screws and washer as in roof/wall , complete all as specified and directed.
Material and labour PCC 1:2:4 type B-1 (20 mm graded stone aggs) as in roof padding (not exceeding 30mm thick) , roof kerbs rounded or chamfered on edges complete all as specified and directed.
Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 on concrete roof surfaces for maintaining proper roof slope including flashings and junction of parapets etc , finishing the surface even and fair without using extra cement, all as specified and directed .
APP based polymeric membrane 3mm thick, minimum weight 3 kg/Square metre , reinforced with polyester non woven fabric (weight not less than 150 gms/Square metre) laid on primed surface by torch application on and including bituminous primer @ 0.40 ltrs per square metre by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, . The membrane shall be laid using butane torch and sealing all joints as per manufacturers instructions after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/Square metre on top of membrane, complete all as specified and directed.
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Square metrem ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Square metrem ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit 20mm bore, terminated on and including sheet steel modular sunken/ flush boxes 1.2mm thickness and suitable size of frame cover for mounting switch, sockets, regulator, fixed on surface in touch with wall, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch and fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /floor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
All as per serial item 87 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
All as per serial item 87 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 87 herein before but for one light point controlled by two way switches, complete all as specified and directed
All as per serial item 87 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Square metrem (nominal area ) FRLSH cable & 2.5 Square metrem (nominal area ) cable as earth continuity conductor
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Square metrem ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Square metrem ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit, terminated on and including sheet steel modular sunken/ flush boxes 1.2mm thickness and suitable size of frame cover for mounting switch, sockets, regulator, fixed on surface in touch with wall, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch and fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /floor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
All as per serial item 92 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
All as per serial item 92 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 92 herein before but for one light point controlled by two way switches, complete all as specified and directed
All as per serial item 92 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Square metrem (nominal area ) FRLSH cable & 2.5 Square metrem (nominal area ) cable as earth continuity conductor
Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed
Modular switch 1 way 6A, 1 module, complete all as directed
Modular switch 2 way 6A, 1 module, complete all as directed
Switch piano, flush type, 16 amps, 230 volts, single pole, one way (ISI marked) complete all as directed
Modular switch 1 way 16A, 1 module, complete all as directed
Sockets outlet multipurpose 2 in 1 pin, 6 Amps flush type ISI marked all as specified and directed
Modular Socket, 6A - 2/3 pin combined 2 module, all as specified and directed
Sockets outlet multipurpose 2 in 1 pin, 6/16 Amps flush type ISI marked all as specified and directed
Modular Socket, 6/16A ,2/3 pin combined 2 module, all as specified and directed
Modular type fan step regulator, 120W - 2 module, all as specified and directed.
Modular Bell push 6A 1 module, all as specified and directed.
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed .
Diconnecting and taking down old MCCB, MCB DB's along with MCB's, complete all as directed.
MCB DB, with provision for incoming 2 pole (MCB / Isolator ) and single phase outgoing, suitable for surface and flush mounting, IP 43 protection, of metal 2 way, fixed in repairs, complete all as specified and directed.
MCB DB, with provision for incoming 2 pole (MCB / Isolator ) and single phase outgoing, suitable for surface and flush mounting, IP 43 protection, of metal 8 way double door, complete all as specified and directed.
MCB DB, with provision for incoming 2 pole (MCB / Isolator ) and single phase outgoing, suitable for surface and flush mounting, IP 43 protection, of metal 12 way double door, fixed in repairs, complete all as specified and directed.
MCB ,SPN, 240 volt, 32 Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs, complete all as specified and directed
MCB ,SPN, 240 volt, 40/63Amp, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs, complete all as specified and directed
MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs, complete all as specified and directed
MCCB of capacity 63 Amps, four pole,3 phase ,16KA, 415 volt with adjustable thermal and maganetic release complete with thimbles, fixed in repairs, all as specified and directed.
Vertical TPN distribution board, double door flush mounting with provisions for MCCBs incomer upto 125Amps 415 volts and outgoing 4 way having IP 54 protection, fixed in repairs, complete all as directed.
Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting including 9 watts LED lamp, complete all as specified and directed.
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, fixed in repairs, all as directed.
LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, fixed in repairs,all as directed.
Indoor decorative extruded aluminium anodized housing /CRCA sheet steel coated housing LED batten type luminaries (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation, 4 feet long, high efficiency electronic driver, system wattage not more than 20 watt with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sq mm, all as directed.
All as per Srl item no 121 here-in-before but fixed in repairs.
Decorative wall light fixture made up of carbonate, suitable for 15 watt, all as specified. Make: Havells CITY 3 cat part no: LHDL06160099 or equivalent in CG/Phillips.
Surface mounted LED porch down lighter, 06 watt, complete all as specified and directed. Make:Havells cat part no: LHEAABP7IL1W006 or equivalent in Phillips/CG as approved.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion , all as directed.
Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth strip of 34 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including GI protection pipe, light grade 40mm, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated and testing on completion including removing / dismantling of old earthing , all as directed.
GI bracket made of GI pipe, medium Grade of size 40mm dia and 1.5 mtr long, bend to shape of 120 degree, fixed to pole/wall with clamp of size 50x6 of suitable length ,fixed with nuts/ bolts and 1.5 mtere long 1.5 sqmm 2 core flexible wire from connector / ceiling rose to light fitting, complete all as specified and directed.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, all as specified and directed .
LED panel of size 2' x 2' of 36 watts, surface mounted with heat exchanger, LED driver surge protection, complete including cutting hole of requisite size in false ceiling, taking out old light fitting and making good the disturbed surfaces, all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm, 2 core, all as specified and directed.
Double walled corrugated HDPE duct pipe of 25mm dia, coforming to IS-14930 Part-II with anti-rodent and non flame propagating properties, of approved colour with fittings for cable protection, all as specified and directed.
Making opening of suitable size in existing brick wall for fixing of exhaust fan of 300mm sweep and making good the disturbed surface by plaster in CM(1:4) , all as directed by Engr-in Charge.for
Metallic body exhaust fan of 300mm sweep , 230 V and 50 Hz, with louvers and shutter, all as specified and directed.
Taking down of copper sub main wiring including existing battens/conduit etc, complete all as specified and directed.
Sub main wiring using two single core, PVC insulated and unsheathed FRLSH multi stranded copper conductor of size 6 Sqmm ( nominal area) 1100 volts grade with and including PVC pipe of minimum 25mm dia size with cutting & chases in wall and making good for for PVC concealed conduit with and including continuous earth wire of size of 06 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade, cable as earth wire and connected to main board ,complete all as specified and directed. Note : (i) Three runs each of one RM of 6 Sqmm cable shall be considered as 1 running metre for payment purposes.
Sub main wiring using four single core, PVC insulated and unsheathed FRLSH multi stranded copper conductor of size 16 Sqmm ( nominal area) 1100 volts grade with and including PVC conduit of requisite dia size with cutting & chases in wall and making good for for PVC concealed conduit with and including continuous earth wire of 16 Sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor 1100 volts grade, cable as earth wire and connected to main board ,complete all as specified and directed. Note : (i) Five runs each of one RM of 16 Square mm cable shall be considered as 1 running metre for payment purposes.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
Full body Non skid vitrified coloured tiles 9 to 10 mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors & skirting, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:4, complete all as specified and directed.
Factory made CPRI approved LT Panel board, outdoor type double door , suitable for floor mounting of size not less than 1500 x 900 x 450 mm with locking arrangement , fabricated out of 2mm thick CRCA sheet, powder coated , dust/water & vermin proof , suitable for 415 volts 3 phase 50 Hz with 4 No's heat shrinkable insulated copper bus bars of capacity not less than 1.5 times of incoming MCCB's including all MCCB connections , having ISMC 75 for base frame, 750 mm long legs of 50mm x6 mm angle iron (04 Nos) grouted in PCC 1:2:4, all as directed, complete with and including the following accessories :- (a) Four pole MCCB 415 volts, 50 HZ, 630 amps with adjustable thermal & magnetic release capacity 50 KA and Ics = 100 % of Icu - 01 No - INCOMING (b) Four pole MCCB 415 volts, 50 HZ, 100 amps with adjustable thermal & magnetic release capacity 25 KA and Ics = 100 % of Icu - 08 No - OUTGOING (c) Phase indicator lamp complete with copper control wiring with suitable size of CT complete - 01 (set of three). (d) Earthing terminals - 02 Nos. (e) Digital type LCD display voltmeter and ammeter of size 96mm x 96mm- 01 set. (f) Danger notice plate dully rivetted/fixed on front door - 01 No Note: Removal/dismantling of old LT panel is included in this item.
Premier Constructions
M/s Om parkash
M/s APEX ENTERPRISES
PARVEEN KUMAR AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .