Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹46.1 L+₹3.2 L (7.39%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹46.3 L+₹3.4 L (7.90%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹46.8 L+₹3.9 L (9.10%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO NOT RESPONDED FOR SHORT FALL DOCUMENTS |
Tender Value
Refer Docs
EMD Value
₹86,400
Closing Date
8 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF CERTAIN SANCTIONED WORK AT AF STN SULUR
2024_MES_637097_1
8628/E8
Open Tender
Miscellaneous Works
Item Wise
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹86,400
Yes
11 Mar 2024
12 Jan 2024
9 Feb 2024
12 Jan 2024
8 Feb 2024
26 Jan 2024
12 Jan 2024 - 23 Jan 2024
Amount
SCHEDULE A BOQ
Excavation in trenches not exceeding 1.5m wide and not exceeeding 1.5m in depth and getting out in hard/dense soil for laying of cables, complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms in hard/dense soil complete all as specified and directed
Removing excavated material to a distance n. exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed
Note for Item No 5 :- The rate is deemed to be inclusive for additional qty of sand if required, to be obtain from out side MD land In case sufficient sand not obtained from excavation as directed by the Engineer-in-Charge.
Supply and lay old size bricks common burnt clay sub-class B for cable protection.
Supplying and fixing 3 x 1.5 sq. mm. PVC insulated and PVC sheathed amoured copper cable complete all as specified and directed.
Supplying and fixing 4 x 1.5 sq. mm. PVC insulated and PVC sheathed amoured copper cable complete all as specified and directed.
Supplying and fixing 6 x 2.5 sq. mm. PVC insulated and PVC sheathed amoured copper cable complete all as specified and directed.
Supplying and fixing 12 x 2.5 sq. mm. PVC insulated and PVC sheathed amoured copper cable complete all as specified and directed.
Supply, Installation Testing & Commissioning of COMPUTER having the following specifications comnplete all as :- (i) Processor :- INTEL i7 processor (ii) RAM :- 8 GB RAM (iii) Hard Disk :- 1 TB storage capacity (iv) Keyboard, Mouse and LAN port. (v) Inbuilt software :- Windows 10 pro or above version along with Anti virus software.
Supply, Installation, Testing and Commissioning of outdoor type power coated PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel made out of 1.6mm thick CRCA sheet for control and monitoring of Ultra Sonic Level Sensor - 01 No, Motorised valves - 02 Nos, along with provision of arrangement for controlling of one more motorised valve as future expansion complete all as directed by Engr-in-Charge. The panel should be of minimum size 1000x750x200mm front opening type, double door type, mounting on support made of anngle iron of size 40x40x5mm with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size. Location:Akash OHT
Note for Item No 13:- The panel shall consist of the following equipments:- (i) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC .
(ii) 4" LCD HMI
(iii) Transformer with regulated output voltage of 230V +/-5%,
(iv) SMPS of Suitable rating
(v) Set of Control Relays and suitable MCB
(vi) Audio visual generator
(vii) Suitable No. of LED Indicators for easy visualisation
(viii) Selecetor Swtiches
(ix) Push Buttons / Illuminated Push Buttons
(x) 0.5 sqmm multistrand internal wiring with ferruling and suitable lugs.
(xi) Memorandum of Understanding :- The tenderers shall submit memorandum of understanding (MOU) from the original equipment manufacturer of the Programmable Controller for installation,testing, commissioning . The contractor shall have to upload the MoU with OEM alongwith Tender documents as per Annexure 'A' given in Particular Specification (ii) PLC control panel should synchronise with the existing SCADA System in AF Stn Sulur
Supply, installation, testing and commissioning of centralized SCADA software for operation, visualization and data acquisition for street light infrastructure and water supply system as per specifications and as directed by the Engineer-in-charge.
Note for Item No 25:- (a) SUPERVISORY CONTROL AND DATA AQUISITION (SCADA) software shall have the programming librarygeneration, soft keys etc. for graphical display and operation by means of soft keys of the automated street light control system, Water supply systems like Pump Houses, Overhead tanks,UG sumps as required by the Engineer in Charge.
(b) SCADA software shall have multi- level password protection, redundancy features, etc.
(c) SCADA shall be capable of integrating the additional installations.
(d) SCADA system should have provision of both manual and automatic operation. (i) configurable database, events, parameters and alarms ii) Multiple project configurable as required by the Engineer in Charge.
Supply, Installation, Testing and Commissioning of a suitable OPC server for unlimited tags with MODBUS TCP/equivalent driver having provision for IOT gateway to exchange data between the PLC based panels and the system complete all as directed by Engr-in-Cherge.
Supply, Installation, Testing and Commissioning of VPN Firewall with 1 year Enterprise Guard License with Ethernet interfaces (fixed) – 4 GbE copper, I/O ports – 2x USB 2.0, 1 x Micro-USB, 1 x COM (RJ45) complete all as directed by Engr-in-Charge.
Supply, Installation, Testing of VPN Firewall at SCADA Server Station, Configuration of VPN Server with Firewall Policies and suitable IPsec tunnels complete all as directed by Engr-in-Charge.
Supply, Installation, Testing and Commissioning of GPRS Modem Dual SIM redundancy for persistent 2G/3G/4G cellular network connections having features of Ipsec /Open VPN /GRE /L2TP /PPTP/ DMVPN with 1 Ethernet Port, 1 RS232/RS485 Port complete all as directed by Engr-in-Charge.
Up-gradation of the existing SCADA software to incorporate management and control of pump house, OHT, HT, developing and adding the additional features as described below by altering the existing SCADA software complete all as specified and directed.
Note for Item No 34 :- The software shall have following features a) Development of libraries and screens for display of the schematic of the remote motorized valves
b) Creation of additional soft keys for remote / manual operation of the motorized valves in the OHTs.
c) Modification of the Main SCADA screen to create a link to easily navigate to the newly developed OHT, PH, HT schematic screen etc. as required.
d) The contractor shall ensure that updation should not disturb the previous data.
Supply, Installation, Testing and Re-commissioning of existing PLC based panels, Configuration of IPsec tunnels/assigning the IPv4 address with compatible subnet mask for 4G dual SIM based modem, ISP router reconfiguration for virtual server and port forwarding complete all as directed by Engr-in-Charge.
Supply, Installation, Testing and Commissioning of UPS for minimum 60 Minutes of battery backup single phase AC input 160 to 260V and output 230 ± 1 % of capacity 1 KVA for running of SCADA computer complete all as directed by Engr-in-Charge.
Upgradation of Exisiting CMDS software domain registration and actibation to facilitate the following complete all as directed by Engr-in-Charge :-
(i)Developer i Phone Mobile App for Service Users similar to Android App
(ii)Publish and Update the i Phone App poicies to Apple Play Store.
(iii)Walkin Complaint Registration.
(iv)Export to Excel Option in Complaint Books and Every Report.
(v)Majaor Complaint Notification Sent on Mobile App.
(vi)Contractor and JE App Updation for Android Only.
(vii) Publish IPhone App to Store and Implement Apple App Store Guide Lines
Terms and condition for Item No 41 :- (a) IPhone application shall be exactly similar to android application
(b)Software Features shall be updated in existing software.
(c) The contractor shall ensure that updation should not disturb the previous data.
Supply, Installation, Testing, Commissioning & Programming of Floor Mounted powder coated Single Phase PLC based indoor type Panels of minimum size 1200x950x300mm made with 1.6 mm thick CRCA sheet, front opening and double door type, with powder coated metal stand made of angle iron with size 40x40x5 mm for Remote Monitoring Control Panel suitable for Remote Monitoring of 11 nos. 11 KV VCBs, which capable to aquire the followings complete all as directed by Engr-in-Charge. Location :Gulmohar Sewage Treatment plant
The PLC Panel shall aquire the below mentioned signals from the VCB Panel; a. Circuit Breaker (ON & OFF status)
b. Trip Circuit Healthy
c. Spring charged
d. Auto Tripped
e. R,Y, B - indications
f. Analog value of current for all three phases for all Modules.
g. Analog value of voltage from the PT (wherever PT exists)
Note for Item No 52:- The scope of work includes providing and installing Additional hardware / accessories in each VCB as per site requirement. The PLC based Panel shall consist of the follwing sub systems (i) Energy meters (06 Nos) with inbult mod bus communication port
(ii) PLC (01 No) with follwing specifications; a. 198 nos Digital inputs / Outputs and 10 Nos. analog inputs b. 4 serial ports supporting open communication protocol c. Programming software based on IEC to facilitate building of custom built function blocks d. Expandable upto 256 DI / DOs
(iii) HMI - 7" (min) (01 No) Graphical Touch screen mluticolour having following minimum features a. serial ports 02 Nos. and USB port 01 No b. Floating Point support c. Built in RTC d. Bar Graph and image (bmp, jpeg files) e. Realtime and historical Trending, f. Realtime and historical alarms,
(iv) 01 no. SMPS of 5 A rating
(v) 01 no. Suitable Surge Protection device suitable for 230V incoming supply
(vi) Suitable no. of interposing relays of 2 A contact rating and suitable voltage rating
(vii) Battery with battery charger for powering the panel for a minimum 60 minutes in case of supply failure.
(viii) Primary communication is OFC, Seconday - GPRS enabled wireless dual SIM card based communication module supporting DNP 3.0 protocol with suitable antenna using 02 different service providers. The module should be programmed to automatically toggle between the two service providers based on the actual signal strength available. The quoted cost shall deemed to be inclusive for the cost of communication for a period of during entire defect liability period from the date of completion.
(ix) Communication between PLC Panel and Smart Station Platform shall be using DNP 3.0 protocol to be installed at MRS
(x) Memorandum of Understanding :- The tenderers shall submit memorandum of understanding (MOU) from the original equipment manufacturer of the Programmable Controller for installation,testing, commissioning . The contractor shall have to upload the MoU with OEM alongwith Tender documents as per Annexure 'A' given in Particular Specification (ii) PLC control panel should synchronise with the existing SCADA System in AF Stn Sulur
Supply, Installation, Testing and Commissioning of outdoor type PLC (Programmable Logic Controller) based Slave Monitoring / Annunciating Control Panel of minimum size 1000x750x200mm made out of 1.6mm thick CRCA sheet mounting on powder coated channel 40x40x5mm made of angle iron for control and monitoring of the following:- Locations:Kalpa PH Centifugal pump -01 No Pressure Transmitter - 01 No Priming solenoid valves - 02 Nos, Air releasing solenoid valve - 01 No Motorised Actuator - 02 Nos
Note for Item No 70:- The panel shall consist of the following equipments; (i) PLC with suitable Digital and analog Inputs / outputs, expansion modules, RTC etc.,
(ii)4" LCD HMI
(iii) Transformer with regulated output voltage of 230V +/-5%,
(iv)SMPS Suitable rating,
(v) Set of Control Relays and suitable MCB
(vi) audio visual generator etc.
(vii) Suitable No. of LED Indicators for easy visualisation
(ix) Push Buttons / Illuminated Push Buttons
(x) 0.5 sqmm multistranded internal wiring with ferruling and suitable lugs.
(xi) OFC communication Panel with the following equipments:- (i)Media Converter (ii)Ethernet Switch (iii) LIU(Light Interface Unit)box patch chord and mounting accessories Communication: OFC Note: The cost shall include the cost of communication for a period of 12 months from the date of completion of work.
(x) Memorandum of Understanding :- The tenderers shall submit memorandum of understanding (MOU) from the original equipment manufacturer of the Programmable Controller for installation,testing, commissioning . The contractor shall have to upload the MoU with OEM alongwith Tender documents as per Annexure 'A' given in Particular Specification (ii) PLC control panel should synchronise with the existing SCADA System in AF Stn Sulur
Supply, Installation Testing & Commissioning of solenoid valve suitable for 10mm GI pipe for priming of pump including bypass arrangement using 10 mm. gate / ball valve with necessary GI fittings with following specifications: Size: 10 mm Material : SS/ Forged Brass/ Cast Bronze Type: Pilot operated, diaphragm type / direct acting type. Pressure rating: 6 kg / sq. cm. Normally closed
Supply, Installation Testing & Commissioning of Pressure Transmitter with Range 0-10 kg/sq. cm and Weather proof IP 65 Enclosure with following specifications:-. :
(a) Working Principle : Micro - Capacitance Silicon sensor
(b) Type : Smart Microprocessor based, 2 wire
(c) Output : 4 – 20 mA DC with Digital Communication (HART protocol)
(d) Power Supply : 10.5 – 45 V DC
(e) Field Communication : Adjustment through push buttons on LCD or Hand-Held HART
(f) Calibrator OR Remotely by PC Possible
(g) Span & Zero Adjustment : Local & Remote
(h) Accuracy : 0.065 % of calibrated Span
(j) Drift / Stability : ±0.1 % of URL for 10 years
(k) Ambient Temp : 40oC to 85oC
(l) Process Temp. Limits : - 40oC to 100oC
(m) Humidity : 0 to 100 % RH
(n) Load Impedance : 577 ohm at 24 V DC
(o) Diagnostic : Self indicating feature
(p) Supply voltage effect : Less Than 0.005% of calibration span per volts
(q) Temperature effect : Less than ± 0.05% of span per 100 C
(r) Zero Elevation & suppress : Anywhere within the range limits maintaining min allowable span
(s) Turn on time : Less Than 10 sec
(t) Damping : 0.06 to 32 sec (configurable)
(u)Vibration effect : Better than ± 0.2 % of span per g at 200 Hz in any axis
(v) Response Time : Less Than 150 msec
(w) Over Range Pressure : Capable of withstanding over pressure upto 3 Times
(x) Update Time : Better than 50 msec
(y) Housing : Die cast aluminum alloy finished with polyester coating
(z) Protection class : IP 68
(aa) Wetted Parts : SS 316
(ab) Flange material : SS 316
(ac) Diaphragm material : SS 316L
(ad) Process Connection : G ½‖ male
(ae) Electrical connection : ½ NPT
(af) Mounting Brackets : Provided (SS)
(ag) Turndown Ratio : 100: 1
Supply, Installation Testing & Commissioning of motorized / solenoid valve suitable for 25mm GI pipe for priming of pump including suitable bypass with necessary GI fittings with following specifications: Size: 25 mm. Material : SS/ Forged Brass/ Cast Bronze Pressure rating: 6 kg / sq. cm.
Supply and fixing 6F HDPE sheathed armoured uni-tube SM optical Fibre cable with central loose tube with jelly compound and high quality electro chromium coated corrugated steel type laid over head on existing available supports complete all as specified and directed
raashi constructions
mahadevi Enterprises
ANAND R L
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .