| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAdmitted-Finance | ₹11.8 L | L1 | Admitted-Finance |
| 2 | L2₹11.9 LAdmitted-Finance 487 A 1 GOPAL MISHRA ROAD BEHALA KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | ₹11.9 L | L2 | Admitted-Finance |
| 3 | L3₹12.2 LAdmitted-Finance GROUND FLOOR HOLDING NO N 113 2402 GANDHI NAGAR WARD 43 SEVOKE ROAD DARJEELING WEST BENGAL 734001 UDYAM WB 09 0043581 | JALPAIGURI | WEST BENGAL | 734001 | ₹12.2 L | L3 | Admitted-Finance |
Tender Value
₹11.9 L
EMD Value
₹23,860
Closing Date
28 Jan 2026, 10:00 amClosed
Joint Project Manager (Electrical), HRBC
ST. GEORGES GATE ROAD (MUNSHI PREM CHAND SARANI) KOLKATA-700 021
Improvement of illumination by supplying and fixing new LED Power saving light fittings and allied electrical works at Kona Expressway and Andul Road under H.R.B.C
2026_HRBC_987787_1
HRBC/JPM(E)/NIT/15/25-26
Open Tender
ELECTRICAL WORKS ORG
15 days
KOLKATA
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹23,860
13 Feb 2026
14 Jan 2026
30 Jan 2026
14 Jan 2026
28 Jan 2026
14 Jan 2026
Supply and fixing of 240 Volt, 50Hz, 200 watt LED street lighting luminaire. (Make -Crompton / Philips / Wipro / LT). i) Lumen efficacy > or = 135 Lumen/ Watt, ii) CCT- 5700K iii) CRI = or > 70 iv) THD < or = 10% (at Full Load), v) SDCM < or = 05, vi) P.F = or > 0.95. viii) Efficiency should be = or > 85%, ix) The Driver(Make - XITANIUM / MEANWELL / OSRAM / INVENTRONICS) should be a potted driver and mounted inside the luminaire. Wattage of the Driver should always be greater than OR equal to the Wattage of the Luminaire. x) The LED chip module(make- Osram / Nichia / Cree or Bridgelux etc.) xi)LED chip module should not be overdriven or underdriven by the driver as compared to its rated current as per OEM standard. xii) The luminer must have pure polyester powder coated pressure die cast Al. housing IP 66, impact resistance IK >= 07. xiii) SPD internal should be 4 KV and external should be 10 KV,and covered in proper housing. xiv) Luminaire and Driver both should have the life of 75000 burning hour @ L70B50, having LM79, LM80, BIS type test report from a NABL accredited Govt. LAB. xv) Each Light fittings should be of 05 Years Warranty approved from minimum rank of Regional Manager level or Equivalent of the manufacturing Co. & from the Agency.
Supply and fixing of PVC loop box (Make- Sintex/ Hensel) (250 x 200 x 105) mm with 04 nos. Elmex make stud type connector, connector channel etc. and necy. Connection complete.
Supply and delivery of 1.1 KV grade PVC insulated XLPE aluminum armored cable 4 core 16 sq. mm. (Make- HAVELLS /KEI/GLOSTER/POLYCAB)
Laying of one No. cable upto 35 sqmm in under ground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of cable as below, after cutting floor/ pavement /wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish, i)From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below 4 Core 16 Sq. mm PVC Al. Ar. Cable.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 35 Sq. mm PVC Al. Ar. Cable
Civil work for making CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76mt. above ground level, neatly cemented finish (3 mmthick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required d) 2 x 36/0.3 (2.5 sqmm)
Dismainteling of existing damage muffing, existiing loop box, existing Light Fittings & other electrical accessories.
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. d) 1st coat of synthetic enamel paint over the primer e) 2nd coat of synthetic enamel paint over the 1st coat
Please Enable Macros to View BoQ information
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.22 MB
Tender_Docs.pdf
Tender Documents • 0.29 MB
2911Form.pdf
Tender Documents • 1.02 MB
BOQ_2412943.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid