| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable bid | |
| 2 | L2₹37.9 L+₹7.1 L (22.9%)Rejected-Finance | L2 | Rejected-Finance other than lowest bid | |
| 3 | L3₹41.8 L+₹10.9 L (35.5%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L3 | Rejected-Finance other than lowest bid |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
17 Jun 2020, 6:00 pmClosed
Garrison Engineer (West) Jalandhar Cantt
Garrison Engineer (West) Jalandhar Cantt
As described in Bill of quantities
2020_MES_346720_1
GE/JAL(W)-13/2020-21
Open Tender
Civil Works
Item Rate
183 days
Jalandhar Cantt
As per Tender Documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (West) Jalandhar Cantt
₹88,000
Yes
17 Jul 2020
22 May 2020
19 Jun 2020
22 May 2020
17 Jun 2020
5 Jun 2020
Amount
Schedule 'A' Part-I (B/R Works)
Surface dressing n.exc (not exceeding) 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in post holes (or similar holes) in hard/dense soil each n. exc. 0.5Cum, getting out, returning, filling in, and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to adistance n. exc. 50m and making good the disturbed surface complete all as specified and as directed.
Excavation in trenches not exc. 1.5 m wide and n. exc. 1.5m in depth for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes, sewage line etc. and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, including, spreading, leveling and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing excavated material to a distance n exc 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description in any position not otherwise specifically provided for (below or above ground level) complete all as specified and as directed.
Material and labour for plain cement concrete 1:5:10 type E-2 (40mm graded graded stone aggregate) as in foundations, filling and mass concrete, posts and the like complete all as specified and as directed.
Material and labour for plain cement concrete 1:4:8 type D-2 (40mm graded graded stone aggregate) as in foundations, filling and mass concrete, posts and the like complete all as specified and as directed.
Material and labour for plain cement concrete1:2:4 type B-2 (40mm graded graded stone aggregate) as in foundations, filling and mass concrete, posts and the like complete all as specified and as directed.
Material and labour for reinforced cement concrete1:2:4 type B-1 (20mm graded graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Demolition of cement concrete (Unreinforced) of any description in ground floor and paving not exceeding 15 cm in thickness (below or above ground level) and removal surplus spoil out of defence land where directed at a level n. exc 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for plain cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs, mud stops, coping/benching/bed plates/plinth band lintles etc. and similar work including weathering, slightly rounded or chamfered edges and throating including necessary form work complete all as specified and as directed.
Material and labour for providing precast cement concrete 1:2:4 type B-0 (12.5mm graded graded stone aggregate) as in louvres and jallies, 35mm thick (measured solid), including all mould ings but excluding frame set in cement mortar 1:4 (Precast frame shall be measured separatelycomplete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars, walls and parapet walls etc complete all as specified and directed.
Material and labour for brick work with sub class 'B' bricks, straight or corvered on plan exc. 6.0m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks, straight or corvered on plan exc. 6.0m mean radius built in cement mortar 1:6 (but except bricks) complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks, straight or corvered on plan exc. 6.0m mean radius built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks, straight or curved on plan in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for form work to soffits of suspended slabs such as roof slabs, floor slabs, shelves, landing and similar work not exceeding 200mm thick (horizontal or sloping) and to edges of concrete surface fair finished complete all as specified and as directed.
Material and labour for 50mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path finishing, joints filled with bitumen and sand mixer 50mm thick, finished the surface even and fair without using extra cement complete all as specified and as directed.
Material and labour for 40mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate as in damp proof course, in horizontal/vertical surface including necessary form work and applying evenly a coat of blown bitumen @ 1.5kg/sqm and blinded with clean dry sand @ 0.05cum.Sqm complete all as specified and directed.
Dismantling, floor hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish outside defence land complete all as specified and as directed.
Material and labour for 25mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in levelling course, surface finished rough to receive topping floor/tiles complete all as specified and directed.
Material and labour for non-skid joint free ceramic coloured tiles, 7-8mm thick (Square/rectangular), area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm; as in floors etc, set and jointed in neat cement slurry and pointing in white or coloured cement to match the surface over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and as directed.
Material and labour for non-skid joint free ceramic coloured tiles, 7-8mm thick (Square/rectangular), area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm; as in dado/skirting etc, set and jointed in neat cement slurry and pointing in white or coloured cement to match the surface over and including 10mm thick backing layer of cement mortar (1:4) complete all as specified and as directed.
Material and labour for glazed ceramic coloured tiles, size 450mmx350mm/300mm x 200mm x 6-7mm thick as on vertical surfaces such as dado/skirting etc set and jointed in neat cement slurry and pointing in white cement with pigment to match the surface over and including 10 mm thick rendering or backing layer of cement mortar (1:4) complete all as specified and as directed.
Material and labour for 10 mm thick vitrified ceramic tiles, (square/rectangle) polished area of each tiles not exceeding 0.36 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match surface and over and including screed bed or bedding layer of cement mortar 15mm thick finished in cement sand mortar 1:6 complete all as specified and as directed.
Material and labour for 75mm thick cement concrete 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in levelling course, surface finished rough to receive topping floor/tiles complete all as specified and directed.
Material and labour for 100mm thick cement concrete 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in floor finished even and smooth without using extra cement complete all specified and as directed. complete all as specified and directed.
Material and labour for 20mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and as directed.
Material and labour for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointing in white cement with pigment to match complete all as specified and directed.
Taking down cement plaster of any description on brick or concrete surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and as directed.
Material and labour for 15mm thick rendering in cement mortar 1:6 on other than fair faces of concrete on roof surfaces finished even and smooth without using extra cement complete all specified and as directed.
Material and labour for 5mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all specified and as directed.
Material and labour for 10mm thick rendering in cement mortar 1:3 on on roof/sunken floors surfaces finished even and smooth without using extra cement with integral water proofing compound @ 3% percent by weight of cement complete all specified and as directed.
Supply only integral water proofing compound @ 3% percent by weight of cement complete all as specified and as directed.
Dismantling brick tiles or tile terracing tiles, single layer on roof including plaster complete all as specified and as directed.
Demolition of mud in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof)
Material and labour for 40 mm thick plain cement concrete 1:2:4 type B-1 as roof padding concrete to bring the existing slab in slope of 1:40 complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and as directed.
Material and labour for 3mm thick superior Atactic poly propylene modified polymeric membrance waterproofing treatment of weight not less than 3.6 Kg per sqm with properties of high penetration and the centre core consisting of 90 micron high Molecular-High Density polyethylene (HMHDPE) film consisting of five layers. The superior multi polyplus is to be laid after preparing the surfaces by cleaning thoroughly to achieve a smooth surface over and including a coat of bitumen primer @ 0.30 Litre per sqm over a coat of hot applied Blown Bitumen of grade 85/25 @ 1.2 kg per sqm. The overlaps between super multi polyplus are minimum 10cm seam in width/lengthwise complete all as specified and all as per manufacturer’s directions.
Material and labour for 40 mm thick brick tiles laid on cement mortar and joints grouted and pointed flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and as directed.
Material and labour for 40 mm thick brick tiles laid on cement mortar and joints grouted and pointed flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement but except brick tiles. (Old serviceable brick tiles shall be re-used). Quoted rate shall be deemed to be included the cost of cleaning and washing of serviceable bricks tiles) complete all as specified and as directed.
Material and labour for flush pointing to brick laid flat or brick tiles in paving cement mortar in 1:3 complete all as specified and as directed.
Supply & fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws or fixed with ‘L’ & ‘J' hooks or cranked bolts complete all as specified and as directed.
Supply & fixing pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws or fixed with ‘L’ & ‘J' hooks or cranked bolts complete all as specified and as directed.
Taking down chowkhat or frames with shutter not exceeding 1.5sqm each with shutters (without taking off shutters form the frames) and removing to or from store complete all as specified and as directed.
Taking down chowkhat or frames with shutter exceeding 1.5 sqm not exceeding 4.0sqm each with shutters (without taking off shutters form the frames) and removing to or from store complete all as specified and as directed.
Taking down shutter of any description exceeding 1sqm but not exceeding 2.0sqm each and re-fixing in the same opening including resecuring or easing and adjusting complete all as specified and as directed.
Taking down shutter of any description not exceeding 1.0sqm each and removing to or from store complete all as specified and as directed.
Taking down shutter of any description exceeding 1sqm but not exceeding 2.0sqm each and removing to or from store complete all as specified and as directed.
Supply & fixing aluminium anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Material and labour for anodised aluminium door shutters, aluminium section weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc, complete all as specified and as directed .
Material and labour for rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410-W (Gde-E-250) Quality A complete all as specified and as directed.
Material and labour for framed work as in doors , gates , guard bar etc of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing Fe 410-W (Gde-E-250) Quality A complete all as specified and as directed.
Material and labour for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 Quality A complete all as specified and as directed.
Material and labour for framed work such as holdfasts, knee piece and similar work conforming to Fe.290.Gde-E-165 Quality A complete all as specified and as directed.
Material and labour for mild steel high yield strength TMT bars 8mm dia and over upto 10mm dia cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Material and labour for mild steel high yield strength TMT bars 6mm to 8mm dia in stirrups, spacers and binders cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
Material and labour for steel ventilator fixed type complete all as specified and as directed.
Supply and fixing PVC solid door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, as per specification mentioned in preambles of section-8 and drawing shown in SSR Part-II (2010) and complete all as specified and as directed.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
Supply and fixing 35mm thick 2nd class hard wood factory made glazed and skelton door shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain fitted with cut and mitered beads for securing glass gauze etc the size of members as per section 8 clause 8.24(a) of SSR Part-I complete all as specified and as directed.
Supply and fixing 35mm thick 2nd class hard wood factory made plain framed panelled shutter (two planel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of the rail and stile as per IS:1003(Part I), kiln sseasoned and chemically pressure treated complete all as specified and as directed.
Supply and fixing 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F steel window 1.25mm thick box type (primer coated) ERW hollow P section of size 60x25mmsingle rebated comprises gauged Skelton shutter ERW sec 50x20mm and 1mm thick with two open able leaf consisting two Nos sash bars of T section 20x3mm completed welded to frame with one vertical mullion of ERW box type T section of size 60x25mm and 1.25mm thick incl cutting holes and making good dismantled portion PCC 1:2:4 type B1 four Nos for each window incl following fittings weld to frame shutter (a) hold fast, 150mm long of 12mmx3mm made to shape-04 Nos per window (b) handle of Z section 20x25mm, 100mm long 01 Nos per leaf (c) MS Tower bolt 150mm long of 12x3mm made to shape-04 Nos per window (b) handle of Z section 20x25mm, 100 long stoper-01 No per leaf () MS pintal of hinges of size 75mmx12mm-02 Nos per leaf (g) fabrication & fixing arrangement as per Drg No. CEJZ/TD-06-07. Note : wire mesh and painting shall be measured and paid separately under appropriate item complete all as specified and directed
All as per description of item No 70 above but with glazed shutter complete all as specified and directed
Supply and fixing 4mm thick size 600x600mm HPSC (High pressure steam cured) pre-primered self embossed, textured designerd board E- board classic to be fixed on including GI powder coated grid /section size 600x600mm with main runner 38x24x0.9mm thick, cross tee 28.6x24x0.9mm and wall angle 19x19x0.9mm duly suspended with 6mm dia GI bar hangers 1200mm c/c both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including provision for light fixtures of any size including dismantling of false ceiling complete all as specified and as directed.
Supply and fixing 4mm thick size 600x600mm HPSC (High pressure steam cured) pre-primered self embossed, textured designerd board E- board classic to be fixed on including GI powder coated grid /section size 600x600mm with main runner 38x24x0.9mm thick, cross tee 28.6x24x0.9mm and wall angle 19x19x0.9mm duly suspended with 6mm dia GI bar hangers 1200mm c/c both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including provision for light fixtures of any size complete all as specified and as directed. (Except material)
Supply and fixing galvanized mild steel wire cloth 0.56mm nominal dia and average width of aperture 1.18mm and fixed with tinned tacks or galvanised steel staples complete all as specified and as directed.
Supply and fixing sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane, complete all as specified and directed.
Supply and fixing 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Supply and fixing 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Supply and fixing 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Supply and fixing aluminium die cast body door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and as directed.
Supply and fixing extruded aluminium alloy handles, 150mm size, fabricated type, anodised complete all as specified and directed.
Supply and fixing 150mm long aluminium anodised barrel tower bolt, of extruded section, with bright bolt and fixed complete all as specified.
Supply and fixing butt hinges, 100mm long, medium weight, cold rolled mild steel complete all as specified and as directed.
Supply and fixing butt hinges, 100mm long, extruded aluminium alloy with galvanised mild steel hinge plate complete all as specified and as directed.
Supply and fixing floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 150mm long complete all as specified and as directed.
Supply and fixing 100mm long, mild steel four lever, vertical type lock with two keys for aluminium door complete all as specified and as directed.
Cutting chases, pinning in, making good to facing where reqd and pointing in cement mortar 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting exc 10 cm but n.exc 20 cm girth complete all as specified and as directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Supply, laying, jointing and testing 15mm bore galvanized iron steel tubing medium grade with all fittings such as bends, elbows, sockets, tees, reducers etc, fixed to walls, ceiling or laid in floors, including cutting through wall complete all as specified and as directed.
Supply, laying, jointing and testing 20mm bore galvanized iron steel tubing medium grade with all fittings such as bends, elbows, sockets, tees, reducers etc, fixed to walls, ceiling or laid in floors, including cutting through wall complete all as specified and as directed.
Refixing old 15mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
Refixing old 20mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
Supply and fixing in repair 15mm bore bib tap with long body chromium plated fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
Supply and fixing 20mm size ball brass valves, high pressure, with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed and fixed complete all as specified and as directed.
Supply and fixing 15mm dia pillar taps cast fancy type (Hot and Cold) copper alloy with capstan heads cromium plated screwed down high pressure with long screwed shanks and fly screwed for iron pipes complete all as specified.
Supply and fixing in repair 15mm bore stop valve/angle cock cast fency type (Concealed) copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
Supply and fixing in repair 15mm bore stop valve/angle cock cast fency type copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
Supply and fixing 20mm bore stop valve/angle cock cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
Supply and fixing 15mm bore brass CP mixer for mixing hot & cold water screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
Supply and fixing 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Supply, hoist and fixing in position, 500 litres capacity rotational moulded polythene water storage tank (cylindrical, vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) conforming to IS 12701, double layered including supply and fixing 20mm dia, 450mm long GI washout pipe (medium grade) with plug and 20mm dia, 600mm long overflow GI pipe (medium grade) with all fittings including dismantling the existing tank complete all as specified and as directed.
Supply, hoist and fixing in position, 1000 litres capacity rotational moulded polythene water storage tank (cylindrical, vertical with closed top) ISI marked (Name of firm embossed or engraved on the body of tank) conforming to IS 12701, double layered including supply and fixing 20mm dia, 450mm long GI washout pipe (medium grade) with plug and 20mm dia, 600mm long overflow GI pipe (medium grade) with all fittings including dismantling the existing tank complete all as specified and as directed.
Supply and fixing acrylic corner set of three pieces as per sample approved by Engineer-in-charge complete all as specified and as directed.
Supply and fixing vitreous china wash hand basin white flat back, size 550mm x 400mm, on and including cast iron cantilever brackets, cutting for and pinning in ends of brackets including waste pipe 32mm dia PVC, waste chain and plug and porcelain stopper, fixing of pillar tap, brass coupling 32mm bore chromium plated, restoring all connections complete all as specified and as directed.
Supply and fixing in repair Orissa pattern squatting pan with integral foot rest, vitreous china white of size 580mm x 440mm including making connection to trap, flush pipe, antisyphonic pipe (but excluding flushing pipe and flushing cistern), provision of lime concrete bedding etc and making good the floor surface complete all as specified and directed.
Supply and fixing in repair vitreous china wash down water closet pan (pedestal pattern), white, and connection to drain (or outgoing pipe) and connection to flushing pipe, anti-syphonage pipe, (excluding flusing cistern and flush pipe) etc complete all as specified and as directed.
Supply and fixing in repair plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
Supply and fixing in repair brass chromium plated jet for china wash down water closet pan (pedestal pattern) with flexible pipe of suitable length etc complete all as specified and as directed.
Supply and fixing in repair 10 litres capacity PVC valveless syphonic action type, low level flushing cistern ISI Marked white with inlet, ball valve, float and handle including brackets fixed complete all as specified and as directed.
Supply and fixing in repair brass chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges fixed with brass chromium plated screws complete all as specified and as directed.
Supply and fixing acrylic shelf 450mm long and 125mm wide over WHB of approved quality as per sample approved complete all as specified and as directed.
Supply and fixing grating chromium plated 150mm dia with centre hole fixed in cement mortar 1:3 complete all as specified and as directed.
Supply and fixing in repair 450mm long PVC connection fiber reinforced, for Hot/Cold water 15mm size with PTMT nuts and washer on both ends complete all as specified and as directed.
Supply and fixing toilet paper holder vitreous china of approved quality as per sample approved by Engineer-in-charge complete all as specified and as directed.
Supply and fixing in repair 32mm dia PVC waste pipe for wash hand basin complete all as specified and as directed.
Demolition and breaking up of 100/75/50mm dia drain pipes (SGSW/AC/PVC) set in cement mortar complete all as specified and as directed.
Demolition and breaking up of 150mm dia drain pipes (SGSW/AC/PVC) set in cement mortar complete all as specified and as directed.
Supply and fixing in repair 110 mm bore PVC (SWR) pipes of pressure rating 6kg/cm2 single socketed in any length with rubber joints with adhehive fixed to walls/ laid in trenches complete all as specifid and as directed.
Supply and fixing 110mm bore PVC (SWR) bends any radius complete all as specified and as directed.
Supply and fixing 110mm bore PVC (SWR) single 'T' , Equal & unequal complete all as specified and as directed.
Supply and fixing 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Supply and fixing in repair 75 mm bore PVC (SWR) pipes of pressure rating 6kg/cm2 single socketed in any length with rubber joints with adhehive fixed to walls/ laid in trenches complete all as specifid and as directed.
Supply and fixing 75mm bore PVC (SWR) bends any radius complete all as specified and as directed.
Supply and fixing 75mm bore PVC (SWR) single 'T', Equal & unequal complete all as specified and as directed.
Supply and fixing PVC (SWR) floor trap, plain with grating including jointing with solvent cement diameter of outlet 75mm complete all as specified and as directed.
Material and labour for 100mm bore salt glazed stone ware drain pipes (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed.
Material and labour for 150mm bore salt glazed stone ware drain pipes (Grade-A) laid in trenches and jointed in CM 1:1 and tested complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in concrete bed to 100mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in concrete bed to 150mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Material and labour for 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
Supply and fixing stack clamps out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm dia pipe complete all as specified and as directed.
Material and labour for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of birla white putty complete all as specified and as directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls by removal of existing treatment complete and applying two coats of oil bound distemper white or tinted over a coat of birla white putty complete all as specified and as directed.
Material and labour for prepration of surface and applying three coats of white (lime) wash on new surface of ceiling complete all as specified and as directed.
Material and labour for prepration of surface and applying two coats of white (lime) wash on old surface of walls complete all as specified and as directed.
Material and labour for prepration of surface and applying two coats of white (lime) wash on old surface of ceiling complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for preparation of old plastered or unplastered surfaces of walls by removal of existing treatment complete and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Material and labour for preparation of new or previously untreated wooden surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of pink primer all as specified and as directed.
Material and labour for preparation of new or previously untreated steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for preparation of old painted steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Schedule 'A' Part-II (Internal electrification)
Taking down carefully aluminum point wiring light /fan /light socket /power with fitting such as ceiling rose, air condition socket, Pendent, regulator, light fitting, street light etc which are not required for use and removing the material from site and making good the surfaces of walls ceiling etc all as per existing including white washing, painting all as per existing complete all as specified and as directed.
Taking down sub main wiring of two single core PVC cable PVC insulated 6/4 sqmm size cable including conduit or wooden batten and removing the material from site and making good the surfaces of walls, ceiling etc all as per existing including white washing, painting all as per existing complete all as specified and as directed.
Taking out unserviceable main switch/DB's acomplete all as specified and as directed.
Material and labour for concealed point wiring with 1.5 Sq.mm (nominal area) single core PVC insulated and unsheathed, FRLS cable, multi-stranded, copper conductor cable 1100 Volts grade with universal colour code (Phase & Neutral), in and including PVC concealed conduit medium grade (ISI marked) with accesories like bends, tee junction boxes etc. with sunk pressed steel terminal boxes and providing 3mm thick bakelite sheet top cover including earth wire of PVC insulated FRLS cable, copper conductor multi-stranded, 1.5 Sq.mm size in green colour, for one light /call bell/fan point controlled by one, one way switch complete all as specified and as directed.
Material and labour for concealed point wiring with 1.5 Sq.mm (nominal area) single core PVC insulated and unsheathed, FRLS cable, multi-stranded, copper conductor cable 1100 Volts grade with universal colour code (Phase & Neutral), in and including PVC concealed conduit medium grade (ISI marked) with accesories like bends, tee junction boxes etc. with sunk pressed steel terminal boxes and providing 3mm thick bakelite sheet top cover including earth wire of PVC insulated FRLS cable, copper conductor multi-stranded, 1.5 Sq.mm size in green colour, for one three pin socket outlet 5 Amps on same board with other switches complete all as specified and as directed.
Material and labour for concealed point wiring with 1.5 Sq.mm (nominal area) single core PVC insulated and unsheathed, FRLS cable, multi-stranded, copper conductor cable 1100 Volts grade with universal colour code (Phase & Neutral), in and including PVC concealed conduit medium grade (ISI marked) with accesories like bends, tee junction boxes etc. with sunk pressed steel terminal boxes and providing 3mm thick bakelite sheet top cover including earth wire of PVC insulated FRLS cable, copper conductor multi-stranded, 1.5 Sq.mm size in green colour, for one three pin socket outlet 5 Amps on independent board complete all as specified and as directed.
Material and labour for concealed point wiring with 2.5 Sq.mm (nominal area) single core PVC insulated and unsheathed, FRLS cable, multi-stranded, copper conductor cable 1100 Volts grade with universal colour code (Phase & Neutral), in and including PVC concealed conduit medium grade (ISI marked) with accesories like bends, tee junction boxes etc. with sunk pressed steel terminal boxes and providing 3mm thick bakelite sheet top cover including earth wire of PVC insulated FRLS cable, copper conductor multi-stranded, 2.5 Sq.mm size in green colour, for one six pin socket outlet 15 Amps on independent board complete all as specified and as directed.
Material and labour for concealed point wiring with 4 Sq.mm (nominal area) single core PVC insulated and unsheathed, FRLS cable, multi-stranded, copper conductor cable 1100 Volts grade with universal colour code (Phase & Neutral), in and including PVC concealed conduit medium grade (ISI marked) with accesories like bends, tee junction boxes etc. with sunk pressed steel terminal boxes and providing 3mm thick bakelite sheet top cover including earth wire of PVC insulated FRLS cable, copper conductor multi-stranded, 4 Sq.mm size in green colour, for AC on independent board complete all as specified and as directed.
Supply and fixing switch piano flush button type, 5 Amps, AC, single pole, one way, 230 Volts (ISI Marked) complete all as specified and as directed.
Supply and fixing socket combination, outlet multi purpose universal type, 5/15 Amps, AC, 6 pin, single pole, one way, 230/250 Volts (ISI Marked) complete all as specified
Supply and fixing socket outlet multi purpose flush type 5 Amps, AC, 5 pin, single pole, one way, 230/250 Volts (ISI Marked) complete all as specified and as directed.
Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm having 3 terminals, PVC polycarbonate, isolated body complete all as specified and as directed.
Supply and fixing lamp holder, PVC/ Polycarbonate type insulated body with back plate suitable for batten fittings including 5Watts LED bulb complete all as specified and as directed.
Supply and fixing sheet metal enclosures for MCB's, double door, distribution board single pole and neutral 8way, 240 Volts with 200Amps rated bus bar complete all as specified and as directed.
Supply and fixing sheet metal enclosures for MCB's, double door, distribution board triple pole and neutral 4way, 415 Volts with 200Amps rated bus bar complete all as specified and as directed.
Supply and fixing MCB's, single pole, 6 to 32 Amps, 240 Volts complete all as specified and as directed.
Supply and fixing Isolator, single pole and neutral, 40 Amps, 240 Volts complete all as specified and as directed.
Supply and fixing Isolator, triple pole and neutral, 63Amps, 415Volts complete all as specified and as directed.
Supply and fixing single pole and earth encolsure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps, 240 Volts complete all as specified and as directed.
Supply and fixing electronic fan regulator, step type, 230/250 Volts and connecting up, complete all as specified and as directed.
Supply and fixing 300mm sweep metal body heavy duty exhaust fan, AC single phase 230/240 volts with louvers/shutter with mounting brackets with suitable size of nuts, bolts, washers make opening in the wall of required size for fixing the exhaust fan and making good the disturbed wall/plastered surface and making electrical connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 1.5Sqmm 3 core complete all as specified and as directed.
Supply and fixing LED batten light fitting (double side) 1X22Watts decorative ultra slim aluminium square profile LED light fixture retrofit with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI 6500K (white light) with LED rod 22Watts with fixtures box type and making electrical connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75Sqmm 3 core complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 25Watts pressure dia cast aluminium IP66, 25watts with 2100 lumen output with internal surge protection device of 10KV, IK7 LED (SEOUL) with voltage band of 140-280V CRI 6500K (white light) and making electrical connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75Sqmm 3 core complete all as specified and as directed.
Supply and fixing in replacement LED 2'x2' ceiling light fitting 34Watts, ultra moderen designed, LED luminaire which provides soft light and glare free symmetrical illumination suitable for arm strong/grid ceiling including fixing arrangements ie nuts, bolts and washers etc and making electrical connections to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75Sqmm 3 core complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel earth plate, electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected and including GI earth lead wire 4mm dia connected to earth plate by means of nuts, bolts, check nuts and washers of galvanised iron or steel, GI earth wire protected by 15mm dia GI pipe 'light grade' upto 2 metre above ground level and connected to machinery earth plate surrounded by packed alternate layers of charcoal and common salt 15cm thick all around top and bottom and watering pipe 20mm bore GI light grade all as shown in electrical plate No 3 of SSR Part-I of 2009, testing on completion including providing PCC chamber (1:3:6) using 20mm graded stone aggregate and 50mm thick cover with RCC 1:2:4 type B-1 and 8mm dia TMT bars 100mm C/C bothway and frame including excavation earthwork and returning filling etc, complete all as specified and directed. Note :- Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit.
Supply and fixing sub main wiring with two single core PVC insulated unsheathed, FRLS multistranded copper conductor cable of size 4 sqmm and one single core PVC insulated unsheathed, FRLS multistranded copper conductor cable green colour of size 4 Sqmm as earth lead through and including 25mm dia PVC concealed conduit with fittings complete all as specified and as directed.
Supply and fixing sub main wiring with two single core PVC insulated unsheathed, FRLS multistranded copper conductor cable of size 6 sqmm and one single core PVC insulated unsheathed, FRLS multistranded copper conductor cable green colour of size 6 Sqmm as earth lead through and including 25mm dia PVC concealed conduit with fittings complete all as specified and as directed.
Taking down XLPE insulated, armoured screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor complete all as specified and as directed.
Excavation in trenches not exc. 1.5 m wide and n. exc. 1.5m in depth for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in, including, spreading, leveling and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing excavated material to a distance n exc 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, fixing and laying GI tubing light grade 40 mm bore with all necessary fitting laid in trenches, under road crossing, in floors or fixed to poles/DB for cable protection etc complete all as specified and as directed.
Supply and laying XLPE insulated, armoured screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of cross sectional area 50Sqmm, 4core complete all as specified and as directed.
Material and labour for sand filling in trenches for cable cushioning 8cm below and 15cm above the cable and compaction complete all as specified and as directed.
Material and labour for sub class 'B' bricks laid in trenches for cable protection complete all as specified and as directed.
M/S Vinod Kumar
siddharthenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .