Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC 01 MADHU BHAWAN FIRST FLOOR FLATE NO 01 NAWADIH DHANBAD JHARKHAND 828130 | DHANBAD | JHARKHAND | 828130 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.4 L+₹1.1 L (5.82%)Rejected-Finance AT KARGALI BAZAR PO BERMO PSBERMO DIST BOKARO JHARKHAND 829104 | BOKARO | JHARKHAND | 829104 | L2 | Rejected-Finance L2 | |
| 3 | L3₹19.8 L+₹1.5 L (7.94%)Rejected-Finance GANDHI NAGAR F 4 BERMO PURVI SUNDAY BAZAR BOKARO 829127 | BOKARO | JHARKHAND | 829127 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹28,700
Closing Date
18 Sept 2024, 11:00 amClosed
PE(EnM), AKKOCP
office of the Project officer ,AKKOCP, PIN 829127
Upgradation and Renovation of mines feeder and Switches along with dedicated secondary switch for 3 mva transformer at 33 kv main sub station akkocp
2024_CCL_317269_2
PE(EnM)/AKK OCP/e-tender/24-25/34
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
AKKOCP
as per NIT
5 documents required · 5 mandatory
₹28,700
Yes
21 Nov 2024
12 Sept 2024
19 Sept 2024
12 Sept 2024
18 Sept 2024
13 Sept 2024
12 Sept 2024 - 17 Sept 2024
Amount
Supply and Providing of round finished polished Aluminium tube for busbar38/50mm outer dia aluminium bus-bar of 6 mm thickness .
Fitting and fixing charges for installation and commissioning of Aluminium bus bar
Providing and fixing of pad connector suitable for bus pipe having outer dia approx 50mm
Providing and fixing of T connector suitable for bus pipe having outer dia approx 50mm
Providing and fixing of connector of alloy aluminium pipe to pipe suitable for bus pipe having outer dia approx 50mm
Providing and fixing of support connector suitable for bus pipe having outer dia 50mm
Providing and fixing of Bi-metallic connector
Supply and providing of 50 mm x 6 mm copper flat for making of Z shape
Fiting, fixing including fabrication charges for Z
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Providing and fixing of corrosion resistant 11kV post insulator
Re-organization, handling including dressing of HT cables to a safe place to avoid any hindrance in the workplace and again handling and placement of cable as as per instruction of Engineer In-Charge
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 120 sq. mm
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Supply and providing of do fuse 600 Amps grade
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1 All kinds of soil
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply of three pole 11KV 400A isolator with all acessories such as handle
Assembling and installation of line/bus isolator on the isolator structure adjusting of opening mechanism in proper alignment so as to ensure smooth operation of the same in case of line isolator
Providing and fixing of Electrical / mechanical interlock arrangement between isolators and breaker with all required material.
Shifting carefully & safely 11KV/ 3.3KV switchgear/ transformer from inside of the switchgear room, including grouting the two nos 100x50x6mm channels pieces (each 800mm long including cutting to size) and foundation bolts in 1:2:4 CC (including cutting of CC of the floor and finishing of floor) as per direction of Engineer in-charge, placing and fixing of switchgear on foundation providing G.I. Nuts & Bolts of proper size in proper position and alignment and checking (hydra/crane is to provided by the agency)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing : 1:1½:3 (1 cement : 1½ coarse sand :3 graded stone aggregate 20 mm nominal size)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Laying of one no pvc insulatedd and pvc sheathed / xlpe power cablw of 11 kv grade of following sizes direct in ground including excavation , same , cushioning , protective covering and refilling of trench etc as required above upto 120 sqmm
Erection of steel tublar or rail pole struct in cement concrete 1:3:6 fouundation including excavation and refilling and secured with holdiing clamps, bolts , nuts etc as required
Supply and Providing of Control cable 2.5 sqmm 8 core
Supplying of two length of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for thrice wire 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron brac.ket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
upgradation of current transformer from 300 amps to 600amps -5-5-5 for control and protection
Supervision, overhead and other incidental cost including contractor's profit @10% of estimated cost
Total impact of GST for the purpose of CTC
M/S ROSHNI ENTERPRISES
M/S MANOJ ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .