SUPREINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, MEERUT
GIVING TEMPORARY CONNECTION 600 KW OR 667 KVA OF MS L AND T CARE OF POORAN SINGH SITE 4C SHATABDI NAGAR, MEERUT UNDER DEPOSIT SCHEME UNDER SDO II PARTAPUR UNDER EDD I MEERUT
2020_PVVNL_503844_1
40/EDC/MT/2020-21
Open Tender
Electrical Works
Lump-sum
15 days
WORK
GIVING TEMPORARY CONNECTION 600 KW OR 667 KVA OF MS L AND T CARE OF POORAN SINGH SITE 4C SHATABDI NAGAR, MEERUT UNDER DEPOSIT SCHEME UNDER SDO II PARTAPUR UNDER EDD I MEERUT
3 documents required · 3 mandatory
₹590
SUPREINTENDING ENGINEER
₹2,000
Yes
10 Sept 2020
22 Aug 2020
4 Sept 2020
22 Aug 2020
4 Sept 2020
22 Aug 2020
180 days
Amount
Cartage of following material from store center Meerut to JE Store including loading & unloading at both ends maximum distance up to 40 Km. :-
ST Pole 11 Mtr. Long.
Line material such as Conductor, Stay rod, Earth Rod, MS Channel, MS Angel, Stay Wire etc. etc.
11 KV CT/PT unit & Metering Cubical
XLPE 11 KV Cable 3x120
Cartage of following material from JE, Store to site of work including loading & unloading at both ends maximum distance up to 40 Km. :-
ST Pole 11 Mtr. Long.
Line material such as Conductor, Stay rod, Earth Rod, MS Channel, MS Angel, Stay Wire etc. etc.
11 KV CT/PT unit & Metering Cubical
XLPE 11 KV Cable 3x120 mm2
Erection of STP Pole 11 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of Soil including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of all 11 KV HT/LT line accessories.
Erection of Double pole on STP pole 11 mtr after digging a pitt of size 1.20 x 0.60 x 1.6 mtr in all type of Soil for each pole including back filling of the pole with proper ramming after completion of work.
Fabrication and fixing of MS angle and MS channel, fixing all 11 KV accessories
Mounting of CT/PT unit
Making a section pole to exist pole after fabrication & fixing of T channel fixing of all 11 KV accessories.
Erection of stay rod complete after digging a pit of size 1.20 x0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming.
Laying lifting stringing of Stay wire double circuit
Earthingh of each 11 KV line pole & T/F properly after drive of electrodes if size 20mm x 250 mm and connection the earthing point with GL wire.
Cutting & chopping tree branches near side of line for making the clearance between line and tree.
Laying of 11 KV XLPE of size 3x120 mm2
Fixing the cable jointing kit with the end of XLPE cable including mounting the same on pole with proper binding.
Grouting of Metering Cubical
GARG ELECTRIC STORE
Shyam Constructions
Kanti Prashad Mittal
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .