Tender Value
₹30.6 L
EMD Value
₹61,300
Closing Date
9 Mar 2024, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
PETTY REPAIR/MAINT OF EXTERNAL WATER SUPPLY AT KHANPUR ARMY CAMP, MANESAR ARMY CAMP, DUNDAHERA MIL STN AND INDU BINOLA UNIVERSITY UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2024_MES_641676_1
GE/DS-76/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹61,300
Yes
15 Apr 2024
9 Feb 2024
11 Mar 2024
9 Feb 2024
9 Mar 2024
24 Feb 2024
Amount
Supply only chloroscope for water testing range of 0.1 ppm to 2.0 ppm Make:- Water Chem
Supply only ORTO-TOLUDINE regent solution in 500 ml bottle Make : Glaxo/SDS/Water Chem/ACME Chemicals.
Supply only ALTOCH-GP high strength calcium based granular disinfectant for chlorination of water.
Supply only first Aid kit (PVC container) No-3 as per the specification including first aid medical treatment materials complete.
Attending day to day external water supply compliants of all nature i.e. leakage in water supply pipe lines,fittings/Fixtures over flow of overhead tank, no water supply two shifts from 0600 hrs to 1400 hrs (1st Shift) and 1400 hrs to 2200 hrs (2nd Shift) including noting the compliants from Khanpur North and South Army camp P/H,Dundahera Mil Station P/H & Manesar Army camp P/H in compliant register and distribution to the tradesman complete all as directed.(Any material required for attending complaints shall be measured & paid separately under respectvie item here-in-after as "Supply only" Note :- The suitable shift duties as deems fit shall be the decision of the Engr-in-charge
Supply only GI union 100 mm bore
Supply only GI union 75/80 mm bore
Supply only GI union 40/50 mm bore
Supply only GI union 20/25 mm bore
Supply only GI socket 100 mm bore
Supply only GI socket 75/80 mm bore
Supply only GI socket 40/50 mm bore
Supply only GI socket 20/25 mm bore
Supply only GI El bow 100 mm bore
Supply only GI El bow 75/80 mm bore
Supply only GI El bow 40/50 mm bore
Supply only GI El bow 20/25 mm bore
Supply only GI End plug 40/50 mm bore
Supply only GI End plug 20/25 mm bore
Supply only GI Tee 80/50 mm bore
Supply only GI Tee 50/40 mm bore
Supply only GI Tee 25/20 mm bore
Supply only GI Flange 80 mm dia
Supply only GI Flange 50 mm bore
Supply only Nipple 20 mm bore
Supply only Nipple 25 mm
Supply only Nipple 40 mm
Supply only Nipple 50 mm
Supply only GI Reducer medium grade 15 mm /20mm
Supply only GI Reducer medium grade 20 mm/25mm
Supply only GI Reducer medium grade 25 mm/40
Supply only GI Reducer medium grade 40 mm/50
Supply only GI Reducer medium grade 25 mm/15mm
Supply only GI Reducer medium grade 40mm/20mm
Supply only GI Reducer medium grade 40mm/25mm
Supply only GI Reducer medium grade 50mm/25mm
Supply only Gun metal gate valve 20 mm
Supply only Gun metal gate valve 25 mm
Supply only Gun metal gate valve 40 mm
Supply only Gun metal gate valve 50 mm
Supply only Float valve 20 mm bore
Supply only Float valve 25 mm bore
Supply only Lead pig Bar
Supply only Spurn Yarn
Supply only Nuts, Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia
Supply only 3mm thick rubber gasket
M&L for cutting and screwing the existing steel tubing of following size bore for addition & alteration or lengthening screw on pipe to form connector complete all as specified and as directed.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
M&L for opening of existing sluice valve including opening of gland cover taking out with stem nut of brass or of stainless steel & refexing the same after with & including replacement of rubber packing, nut & bolts, glands dori etc complete all as specified and as directed of following sizes. Note:- Spare parts under relevant items shall be measured and paid separately under respective items.
80 mm bore
100 mm bore
150 mm bore
Supply only 'stem' made out from stainless steel of sluice valve of following sizes, complete all as specified and as directed.
Stem, 80 mm bore
Stem, 100 mm bore
Stem, 150 mm bore
Supply only 'Stem Nut' made out from stainless steel suitable to match with existing sluice valve, sizes as under, complete all as specified and as directed.
Stem Nut, 80 mm bore
Stem Nut, 100 mm bore
Stem Nut, 150 mm bore
Supply only 'Gland Plate' made out from Cast Iron suitable to match with existing sluice valve, sizes as under, complete all as specified and as directed.
Gland Plate, 80 mm bore
Gland Plate, 100 mm bore
Gland Plate, 150 mm bore
Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed.
M&L for Rubber Gasket joint (Tyton) including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
100 mm bore
150 mm bore
S&F rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed..
S&F rotational moulded polyethylene water storage tanks, cylindrical vertical with closed top, 1000 litres capacity, tripple layered, hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed..
Supply Installation testing and commissioning of retrofit emission control device for 12.5 kVA desiel generator of any make/vintage Category Application:- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine. Technology/Type:- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets.
TEST REPORTS Certification:- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below:- (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set)
Supply Installation testing and commissioning of retrofit emission control device for 15 kVA desiel generator of any make/vintage Category Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets
TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set)
Supply Installation testing and commissioning of retrofit emission control device for 20 kVA desiel generator of any make/vintage Category Application:-Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets
TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set)
Supply Installation testing and commissioning of retrofit emission control device for 35 kVA desiel generator of any make/vintage Category Application:- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type :- ESP (Electrostatic Precipitator), Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) 70% for all DG sets
TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below:- (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set)
Testing of drinking water being collected from local source(bore well/Shallow wells/under ground sumps) in the area under AGE E/M South and submission of detailed test report to the office of Engr-in-Charge as detailed below :-
Notes:- (a) Colleciton of water from different sources of water ie sump, bore wells & shallow wells in sterilized bottle. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour taste, surbidity, PH value TDS total hardness, iron chloride, fluride and residual free chlorine and Bacteriological total E collie form organisms per 100 ml (MPN) and E Collie in 100 ml) and submitting to this office with specific recommendaiton regarding suitability of water for drinking purpose. (c) Rate quoted shall ldeemed to be included for:- (i) Cost of sterilized bottle as required. (ii) To and fro transportaiton charges for collection of samples from sources (sump/bore well/shallow wells)
Note :- The contract sum shall be after deducting the amount of credit shown in Sch of Credit of this tender
amisha trading co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .