Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical NO 33 JEENIS ROAD SAIDAPET CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | Not Admitted-Fee/PreQual/Technical Others-1)Documents Checked and found that CA certificate is upto FY20-21 (2)Labour certificate and Authorization certificate from manufacture not submitted (3) NIT doc not uploaded along with technical bid doc. |
Tender Value
₹12.7 L
EMD Value
₹25,444
Closing Date
14 Nov 2023, 4:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) BSNL Electrical Division-II WMS Compound 47th Cross 9th Main 5th Block Jayanagar Bengaluru 560 041
Tech bid SITC of AFD Fire Alarm System DTC 6th Floor STR NTB Bengaluru Recall1
2023_BSNL_172736_1
28/23-24/BSNL/ED-II/ BGL
Open Tender
Electrical Works
Item Rate
60 days
6th Floor STR NTB Bengaluru
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash) BSNL BGTD
₹25,444
4 Mar 2024
31 Oct 2023
16 Nov 2023
31 Oct 2023
14 Nov 2023
31 Oct 2023
Amount
SITC of AFD System
Fire Alarm Control Panel (FACP): Supply Installation Testing and Commissioning of Microprocessor based 2 wire fault tolerant. Networkable type Fire Alarm detection 2 loop Addressable type AFD control panel (each loop to suit minimum 99No of Fire detectors and 99 No of Modules/devices) The panel shall be able to give location of all fire and fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF the respective control modules whenever any alarm is triggered. The panel shall have rectifier loop cards, 80 characters LCD unit to indicate Fire, Fault signal with address and analog output with provision for adding external printer to log all fire of fault events complete in all respects. The panel shall be sheet steel powder coated sealed to IP:30. The panel shall have LED indicators for indication of various signals. The panel should have TCP/IP Connectivity and should have the facility to view remote access with similar view of FACP PMI . The panel shall have a built in power supply and battery charger along with maintenance free 7Ah 2 x 12Volts SMF batteries capable of Running for minimum of 2 hours with battery charger and conforming to BS: 5839 Standards and duly approved by EN54/LPCB/VDS/UL as per specifications complete in all respects etc. complete as required.
Supply Installation Testing and Commissioning of intelligent analogue Addressable MULTISENSOR type smoke detectors complete with single/twin LED, Hard Addressable having rotary decade Address switches from 01-99, with, mounting base conforming to BS:5839 standards and duly approved by EN54/UL/FM/LPCB/VDS etc complete as required. (Installed on real ceiling/on False ceiling/on false flooring)
Addressable Heat Detector: Supply Installation Testing and Commissioning of EN54/ UL/ FM/ LPCB/ VDS Intelligent Analogue addressable ROR Heat detector with junction box etc. as required.
Response Indicator: SITC of Response indicator having twin LEDs for mounting on false ceiling / wall at the entries of the cabin for indicating the operation of detectors in the above false ceiling / below false flooring detectors etc. as required.
Manual Call Point: Supply Installation Testing and Commissioning of intelligent analogue Addressable Type Manual call points having surface or Flush mounting option fully compliant to EN54 having Rotary Decade switches for addressing from 01-99 with back box for mounting as required conforming to BS5839 Standards and duly approved by EN54/ UL/ FM/ LPCB/ VDS as required.
Electronic Hooter : Supply Installation Testing and Commissioning of addressable type loop powered Hooter complete with mounting base conforming to BS:5839 Standards and duly approved by EN54/ UL/ FM/ LPCB/ VDS as required.
Fault Isolator Module: Supply Installation Testing and Commissioning of Addressable Type Fault isolator for isolating shorted, delinked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable and conforming to BS:5839 Standards and duly approved by EN54/ UL/ FM/ LPCB/ VDS etc. as required.
Addressable control modules: Supply Installation Testing and Commissioning of Addressable control modules for providing tripping contacts for package Air Conditioning system/AHU’s (This shall be wired in loop and located near the AHU's etc as required.
Supply and Laying of additional 2 x 1.5 sq.mm PVC/XLPE insulated, PVC sheathed, FRLS armoured copper cable on surface of wall /ceiling with necessary glands, saddles etc., complete as required. (Make: Any ISI marked cable with FRLS insulation)
Supplying & Fixing GI Box of following size (Nominal size) on surface of with suitable size phenolic laminated sheet cover in front including panting etc., as reqd. a)85x85mm x50mm deep
Supply & making end termination with brass compression gland suitable for 2x1.5 sq. mm. copper cond. UG cable etc., as reqd.
Re-arrangement of existing 2 x 1.5 sq.mm PVC insulated, PVC sheathed, FRLS armoured/flexible copper cable of old Fire Detection system to suit the new Addressable Fire Alarm system i/c dismantling of existing old detector, MCPs, Hooters, Response Indicators, AFD panel, Mimic diagram etc as per the direction of Engineer In-charge etc., as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .