Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.8 LAccepted-AOC B 30 JEEVAN VIHAR SHASTRI NAGAR GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | L-1 | Accepted-AOC Due to L-1 | |
| 2 | L-2₹35.2 L+₹42,590 (1.23%)Rejected-Finance | L-2 | Rejected-Finance Due to L-2 |
Tender Value
₹48.3 L
EMD Value
₹96,600
Closing Date
9 Aug 2023, 6:00 pmClosed
Head CSIR-HRDC
SECTOR-19, KAMALA NEHRU NAGAR GHAZIBAD
Annual maintenance contract for operation and routine maintenance of 11 KV Sub-station, DG Sets, pump house including internal and external electrification, HT LT Panels, distribution boards, internal telephone wiring and maintenance ...
2023_CSIR_162692_1
9-1(1)/2023-24/Elect./AMC/HRDC
Open Tender
Electrical Works
Item Rate
365 days
CSIR-HRDC Ghaziabad
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
HRDC
₹96,600
19 Sept 2023
31 Jul 2023
11 Aug 2023
31 Jul 2023
9 Aug 2023
31 Jul 2023
Amount
Sub Head- I
Operation and day to day routine maintenance of round the clock 11 KV Sub-Station, DG Sets , Pump house, Starter panels, tubewell, Water storage Tank, internal & external electrification, telephone wiring and Air conditioning units in office, Res. and Guest house campus at CSIR-HRDC as follows: Transformers 630 KVA, 11 KV HT with VCB panel , LT Panel, DG Sets 380 KVA with AMF Panel, Battery, Inveters, Distribution boards, monoblock pump Set up to 10 HP, Sumbersible pump up to 10 HP, Window, split and tower type Air-conditioners upto 2.0 TR capecity with stablizers, Water coolers up to 120 Ltrs, Deep frezer and Refrigerators etc. The all above item includes repair/ replacement of essential consumable like cleaning material viz cotton waste, greese, distel water, nut bolt, screw, PVC insulation tape, soap, gland and detergent etc. including maintaining the log book day to day work. All required tools provided by contractor . Details as per Scope of work, Annexure-III and IV.
Sub-Head-II Repair/Replacement of following electrical,mechanical component and accessories etc. complete as required .
LED lamp up to 9 W,250V
Tube light 40 W
Tube light 20 W
LED Tube light fitting 16 W 2feet long
LED Tube light fitting 20 W 4 feet long
Choke copper K-40
Choke copper 18 watt for PLC CFL
PLC CFL 18 watt 2 Pin
Starter for 1x20 W FTL, 110V
Starter for 20/40/80 W FTL, 240V
Contactor coil MNX 95-140, 240V, L&T
Coil for MNX 550 contractor,240V , L&T
Ignitors for 70-400 W SON lamp
Metal clad Industrial plug 2 pole + Earth 250V , 20A
Metal clad Industrial Socket 2 pole + Earth 250V , 20A
PVC insulated copper conductor, single core multistrend wire/cable 1.5 sqmm
PVC insulated copper conductor, single core multistrend wire/cable 2.5 sqmm
FRLS PVC insulated annealed copper conductor, unarmored telephone cable ,four pair, 0.5mm dia
SP 5/6 Amps.one way switch piano type ISI Marked
SP 15/16 Amps.one way switch piano type ISI Marked
6 Pin 15/16 & 5/6 A socket outlet piano type ISI Marked
SP 5/6 Amps.one way modular switch ISI Marked
SP 15/16 Amps.one way modular switch ISI Marked
5 Pin 5/6 A modular socket outlet ISI Marked
6 Pin 15/16 & 5/6 A modular socket outlet ISI Marked
PVC modular Box 3 module
PVC modular Box 6 module
Modular base & cover plate 3 module
Modular base & cover plate 6 module
Call bell electronic suitable for D.C./A.C. single phase, 230 volts
Single pole MCB 5 to 32 Amps ,B series, 240 volts
Fly cacher tube light 18 W
Driver for 30W LED street light for Wipro make
32 A, DP main switch with Key ring tag 2 modul
Hermetically sealed Rotary compressor for 1.5 Ton A.C. Unit for all branded split/window type AC.
Hermetically sealed Rotary compressor for 2.0 Ton A.C. Unit for all branded split/window type AC
Runing capecitor 36/45 MFD
Starting capeciter 80 MFD
Fan motor double shaft for 1.5/2.0 ton window AC
PCB card for 1.5/2.0 ton Split AC unit
Relay for 1.5/2.0 Ton AC
Split A.C. Fan motor for outdoor unit 1.5/2 ton
Split A.C. Fan motor for indoor unit 1.5/2 ton
Gas chargies for following AC's and Refrigrator
(a) Split / Tower AC - 2 Ton
(b) Split AC -1.5 Ton
(c ) Window AC - 2 Ton
(d) Window AC -1.5 Ton
(e ) Refrigerator upto 400 Ltrs.
Sub-Head-III: Rewinding and overhauling of following mono block pump motor including replacement of bearings water seal rusted nut & bolt, repairing of shaft & impeller etc. after disconnecting and reinstallation of the same complete in all respect.
The labour charges for taking out and lowring in same of sumbersible pump set up to 10 HP from borewel including charges of chain pulley and tripol stand etc . Complete in all respect.
Rewinding and assembling of following submersible pump motor with oil seal and including replacement of all necessary spares required for smooth functioning of moter complete in all respect.
Rewinding and overhauling of following exhaust fan replacement of bushes bearing shaft including capacitor etc. complete as required
9" Exhaust fan
12" Exhaust fan
18" Exhaust fan
Rewinding and overhauling of following ceiling fan including Bushes, Bearing, bearing, shaft and capecitor, etc. complete as required.
48" Ceiling fan
56" Ceiling fan
Repairing & maintenance charges of all makes 4/5 KVA A.C. Units voltage stabilizer including PCB and relay etc. complete as required.
M/s Deepak Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .