Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.0 CrAccepted-AOC PLOT NO HIG 7 CHUNVATI LANE GOPALGAN BALASORE 756001 | BALESHWAR | ODISHA | 756001 | ₹7.0 Cr | L-1 | Accepted-AOC Being lowest bidder |
| 2 | L-2₹7.2 Cr+₹25.6 L (3.67%)Rejected-Finance | ₹7.2 Cr+₹25.6 L (3.67%) | L-2 | Rejected-Finance Not being lowest |
| 3 | L-3₹7.8 Cr+₹82.5 L (11.8%)Rejected-Finance NATIONAL TOWER 5TH FLOOR SCO 89 DSC RANJIT AVENUE AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹7.8 Cr+₹82.5 L (11.8%) | L-3 | Rejected-Finance Not being lowest |
| 4 | L-4₹10.0 Cr+₹3.0 Cr (43.0%)Rejected-Finance | ₹10.0 Cr+₹3.0 Cr (43.0%) | L-4 | Rejected-Finance Not being lowest |
Tender Value
₹6.5 Cr
EMD Value
₹6.5 L
Closing Date
16 Feb 2023, 6:00 pmClosed
CE RnD Delhi
HQ CE RND, Probyn Road, Timarpur, Delhi 110054
PROVISION OF CENTRALISED AIR CONDITIONING SYSTEM IN 05 BUILDINGS OF LC-III AT ITR CHANDIPUR
2022_MES_557150_2
CE RND/DLI-15/CHANDI/2022-23
Open Tender
Civil Works
Lump-sum
700 days
Chandipur
Please refer tender documents
8 documents required · 8 mandatory
₹3,000
GE I RND CHANDIPUR
₹6.5 L
Yes
14 Mar 2023
18 Jan 2023
21 Feb 2023
18 Jan 2023
16 Feb 2023
2 Feb 2023
Amount
SCHEDULE `A' SECTION- I BUILDING WORK as under is prepriced by MES based on SSR-2020 Pt-II
Lump sum price worked out by the Contractor for “Building work” as listed in Schedule ‘A’ Sec-I
NOTE : Schedule 'A' Section II to Section XIII as under Ser No. 2.01 to 2.12 are prepriced by MES
Lump sum price worked out by the Contractor for “Excavation, earth work & site development” as listed in Schedule ‘A’ Section- II
Lump sum price worked out by the Contractor for “ROAD/PATH/HARDSTANDING/CULVERTS” as listed in Schedule ‘A’ Secton- III
Lump sum price worked out by the Contractor for “AREA DRAINGE” as listed in Schedule ‘A’ Section- IV
Lump sum price worked out by the Contractor for “AC DUCT” as listed in Schedule ‘A’ Section- V
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- VI
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section- VII
Lump sum price worked out by the Contractor for “FIRE FIGHTING” as listed in Schedule ‘A’ Section- VIII
Lump sum price worked out by the Contractor for “DG SET” as listed in Schedule ‘A’ Section- IX
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’ Section- X
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section- XI
Lump sum price worked out by the Contractor for “AIR CONDITIONING” as listed in Schedule ‘A’ Section- XII
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- XIII
SCHEDULE `A' PART - XIV MISC ITEMS as under is not prepriced by MES.
ROAD/PATH/HARDSTANDING/CULVERTS
M&L for providing, laying and consolidating 150 mm thick (in two layers) Premix WMM from mixing plant rolled 08 to 12 Ton vibrating (Tondom) road roller to confirm uniform surface and compacted to required gradient and camber complete with mechanical paver, filler shall be added as per job mix design complete all as specifed and directed.
SEWAGE DISPOSAL
M&L for RCC NP3 150 mm dia pipes laid on 150mm thick moorum /sand /crushed stone bed with excavation upto depth 1.65 mtr in any type of soil ,incl manholes of standard size made of brick masonary/RCC/precast RCC with SFRC ventilating cover and frame incl all items including necessary testing of pipe after laying the pipe.
M&L for Sokage well of size 1.20mx1.50m effective depth. Internal dia 1.20 m and effective depth 1.50m excavation in any type of soil,foundation in PCC 1:3:6 ,walls of honey combed masonary with top ring of M-25 concrete incl intercepting chamber and screen chamber made of brick masonary in CM,RCC cover slab in M-25 /SFRC cover ,interconnecting pipes of RCC/DWC complete filled brick bats as per TD Drgs and as specified in Particular specification.
M&L for on site LLDPE septic tank design to carry sewage and sullage water ,excavation in any type of soil ,PCC 1:4:8 below foundation ,vent sahft ,connection etc.,complete for 10 user horizontal laid all as specified and directed
Exterenal water Supply
M&L for cutting existing steel tubing for alterations or additions (Each cut measured) of size 100/50 mm bore dia complete all as specified and directed.
M&L for construction of valve pit chamber of size with using fly ash brick of size 250mmx115mmx75mm 1200mmx1200mmx900mm (internal size) with 3.15mm thick MS sheet cover and angle iron 50x50x6mm thick embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation, removal of surplus soil to a distance not exceeding to 50mtr, returning filling, in PCC 1:3:6 type C-2 75mm thick as in foundation /floor brick work (one brick thick) in cement mortars (1:4) PCC 1:3:6 type C1 in copping, plastering in CM 1:4 and 75mm thick hard core below foundation etc complete all as specified and directed.
Supply and fixing brass full way gate valve with C I wheel (screwed end) 80 mm dia complete conforming to latest IS and as approved by GE.
EXTERNAL ELECTRIFICATION
M & L for Cable route indicators for HT cable with CI plate and angle iron 40 x 40 x 6mm showing MES HT cable, voltage and location/direction duly embossed including necessary excavation earth work, PCC work (1:2:4) type B1 for embedding (using 20mm graded aggregate) of size 15 x 15 x40 cm complete all as specified and directed by Engr-in-charge.
BLANK
Supply and fixing of cable junction box made of thermoplastic halogen free,weather proof with metric knock outs for cable entry including four/five pole terminals and cable entry glands for including,out going and connecting cable with protection grade IP 65 and suitable for LT underground cable any size capacity all as specified and directed.
Supply and fixing of GI pipe Bracket of 40 mm dia light grade pipe bend to shape of approx length 1.5 Mtr incl 2 no. MS Clamp of flat iron size 40x6 mm complete with nut, bolt, washers of suitable size all as specified and directed at site.
Supply, install, testing & commisioing of LT control panel board "outdoor type" of size 1500 mm (height)x 1200 mm (width) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make to it completely dust & vermin proof & degree of protection not less than IP- 65 & general construction conforming to IS-13947, double door, front & back openable. The panel shall be provided with venetilation facility in the form of louvers for better heat dissipation & tinned copper bus bar wrapped with colour PVC tapes/sleeves of rating in conformity to the incoming ACB/MCCB rating, The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick for inner portions CRCA sheet duly pre-treated & powder coated, supporting angles iron frame of size 65x65x6mm & MC channel (MC-75) base suitable for 3 ph , 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl copper glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation, necessary earth work (if any) complete all as specified and directed with & incl the following accessories:- (A) BUS -BAR and internal connections The bus-bar shall be made of 04 Nos high grade tinned copper 1000 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable size "F" class insulators of non-hygroscopic, non combusible, all internal connections from main bus bar to switch gear etc.
Fire Fighting
BLANK
Material and labour for cutting existing steel tubing for alternation or additions (Each cut measured) of size 150 mm bore dia complete all as specified and directed.
DG SET
BLANK
Supplying, installing, testing & commissioning of factory assembled silent diesel Engine driven generating set 1500 RPM of capacity 400 KVA, 3 phase, 4 wire, 415 Volts, 0.8 PF, complete with control panel including integrated powder coated acoastic enclousre as per CPCB regulations and duly certified by agencies/lab designated by CPCB for noise and sound pollution level, floor mounted including PCC foundation as per manufactures's instructions complete all as specifed and directed and comprising of the followings:- (A) DIESEL ENGINE Diesel Engine for reuired capacity for driving 400 KVA alternator mutli cylinder , vertical type, 4 stroke, water cooled, electric start, cold starting conforming to IS :10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following:- (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vaccum indicator (vi) Electronic governer (vii) Exhaust silencer (viii) Fuel filler & Fuel hoses (ix) Fan & water pump assembly (x) Lub oil filter & pump
(xi) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 12 Volts.120 AH DC as per manufactures requirement including interconnecting cables/leads with terminals complete with starting/stopping switch. -01 set. (xii) Exhaust gas driven turbo charger (xiii) Engine safety shut down system against low lub oil pressure and high water pressure. (xiv) oil filter (xv) Lub oil cooler (xvi) Emergency stopping switch outside canopy (xvii) Suitably designed acoustic enclosure with locking arrangement of doors as per CPCB regulations/norms. (xviii)Suitably pollution control device to reduce air pollution.
(B) ENGINE INSTRUMENT PANEL Digital type having facility for automatic/manual starting, reset switching with an indicating the following including internal control wiring controlled with MCB & connected to safety features of engine & alternator:- (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil tempreature (vi) Battery charging meter (vii) Safety alarm against high water temp and high lub oil pressure
(C) ALTERNATOR: Alternator shall be self excited, self regulated, bush less for 400 KVA continuous operation at the speed of 1500 RPM at 415 Volts, 50 Hz three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and conforming to IS -13364/4722 or BS-2613 of 1970 complete- 01 No. (D) BASE FRAME Common fabricated base frame for engine & alternator made from structural channel, jerk proof mounted on PCC plateform made of PCC 1:2:4 type B1 foundation incl adequate number of suitable anti vibration pads all as per the recommendation of the manufacture-01 No Note:- Cost of suitable size of PCC foundation incl 400 mm extra PCC platform around the DG Set from outside of the canopy is deemed to be included in the unit rate quoted by the contractor.
(E) FUEL TANK Bottom mounted steel fuel tank fabricated out of 14 SWG MS Sheet of capacity not less than 8 hrs continuous operation, inside canopy with fuel level gauge drain plug locking arrangements etc with & including GI pipe connections duly laid as per sound engineering practice complete. (F) AMF CONTROL PANEL Supply, fabrication, fixing commisioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 400 KVA DG Set, fabricated using 14 guage thick CRCA sheet, powder coated painting suitable rated bus bar, internal wiring with control MCB, provn of connecting incoming & outgoing leads/bus as approved with and including the following accessories as under:- (i) Master switch for auto/manual/reset/off-01 No (ii) Ammeter digital type 96x96 mm to read 0-1000 Amps with CTs 1 set of 3, aux supply 230 volts, AC, Accuracy class 1.0 (iii) Voltmeter digital type, 96x96mm to read 0-500 Volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter-01 No aux supply 230 volts AC (v) Push button start/stop/reset-01 No (vi) Set of lamp for indicating load on, low pressure , high cylinder tempreature, load on mains, set fails to start, low oil pressure. (vii) Battery charger, connected to load side to charge battery from mains comprising of :-
LIGHTING PROTECTION
BLANK
FIRE ALARM SYSTEM
Taking down existing unserviceable fire alram system complete including control panel smoke /fire detector call points, control modules etc encluding worn out wiring materials complete making good to disturbed surface and all as directed.
S&F fire alarm control panel complying with BS EN 54 two loop panel with 99 detectors and 99 modules and upto 200 detectors and module (per each loop) including taking down old all as specified and directed.
S&F detectors complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS:11360 including taking down old all as specified and directed.
All as per item above but addressable type duct detector housing with sampling tube add up cost of smoke detector all as specified and directed.
Supply, installation, commisioning and testing in Beam master detector transceiver type including power supply unit & module all as specified and directed.
Supply, installation, commisioning and testing in adderssable manual call point/station with base complete all as specified and directed.
Supply, installation, commisioning and testing in intelegent addressable control module with base complete all as specified and directed including taking down old.
Supply, installation, commisioning and testing in of fire alarm sounder/siren electronic type horizontal single stage continous type normal operation for atleast 50minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db complete all as specified and directed including taking down old.
FLAME PROOF & INTERNAL ELECTIFICATION
Supply and fix Flame proof energy efficient LED flood light fixture of 120 W complete with all necessary accessories of make shyam switchgear, Cat part No. SSPL/125/or equivalent of make M/s Sudhir, M/s Balliga/flex pro electricals, nasik, Bajaj, Crompton.
S&F flame proof TPN 4 way DB with incoming MCCB 4 pole, 63 Amps, -01 No and outgoing MCB single pole, 6 Amps, 10 KA, "C" series-12 Nos complete with all necessary accessories.of make M/s Sudhir, M/s Balliga, Flexpro electricals, nasik, Bajaj, Crompton
S&F FLP/WP switch/Isolator 10 amps single pole ON/OFF.Cat Part No-RI/A/146-3 all as specified and directed.
S&F flame proof plug in switch socket 16 A, 3 pin (2P+E) complete with all necessary accessories all as specified and directed. Make:- M/s Shyam Switchgear, cat pat No. SSPL/2C/1010 or equivalent to make M/s Sudhir, M/s Balliga, Flexpro electricals, nasik, Bajaj, Crompton
S&F flame proof plugin switch socket 32 Amps, 5 pin (4P+E) complete with all necessary acessories all as specified and directed. Make:- M/s Shyam switchgear, Cat pat No. SSPL/2C/1010/or equivalent to make M/s to make M/s Sudhir, M/s Balliga, Flexpro electricals, nasik, Bajaj, Crompton
S & F Electronic fan regulator, stepped type 120/280V on existing phenolic laminated sheet complete all as directed by Engineer-in-Charge.
Supply and fix LED tube light fitting 1x22 Watt decorative batten with all accessories including taking down old unserviceable complete all as specified Cat Part No STREAKT8UPTO2X22WDSBSWH as approved by GE.
Supply and fix LED tube light fitting 10 Watt, 2 ft decorative aluminium extruded T5 LED Batten integrated type including taking down old us complete all as specified Cat Part No LUMILINE+BS10WLED865SPCSS or equivalent
S&F in repair LED Bldg security light fitting 45 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed.Make Havells Cat Part ENDURASUNDOWNSL45WLED765PASYBOPC
M&L for sub main wiring for Light/power plug for 05/15 A Independent switch socket board with PVC insulated unsheathed stranded FRLS copper conductor cable of size 2x4 Sqmm, with PVC insulated unsheathed stranded FRLS copper conductor cable of size 1x4 Sqmm for earth continuity wire, to be drawn in and including PVC conduit heavy duty with concealed wiring including all necessary wall cutting and making good disturbed surface
S& F metal boxes of size 75mm x75mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S& F metal boxes of size 100mm x100mmx 60mm deep of thickness 1.2mm on surface or recess with suitable size of phenolic laminated sheet cover of thickness 3mm in front including painting and making good of good disturbed surfaces
S&F in repair FLP WP flood light fittings in aluminium alloy LM-6 construction IP-66 degree of protection, suitable for 120 watt LED light with lamp, driver etc, light grey, apoxy powder coated 1 No. internal and 2 Nos. external earthing with SS hardware alongwith 2 Nos. 3/4 "ET Cable entries with suitable double commpressions brass nickle plated cable gland type-A toughend glass certified by CIMFR Dhanbad for gas group-II as per IS/IEC-60079 & code nagpur as per cat No. SSPL/FL/1251 or equivalent to make M/s Sudhir/M/s Balliga/flexpro electricals, Nasik,/ Bajaj/Crompton.
Taking down flame proof sub main wiring from wall/pillar/roof of technical bldgs removing materials from site all as directed.
S&F DB flame proof LM-6 with sheet steel enclosure 63 Amp, TPN, 415 Volts, 3 phase including 12 Nos, SP 6-32 Amps MCB and provision of FLP and including P/O M/s Angle Iron frame on wall of suitable size for fixing complete including taking down all as specified and directed.
BLANK
S&F flame proof and weather proof switch socket and plug combined 16A, 250 Volt (3P+E) all as specified and directed.
BLANK
M&L for earthing complete with copper earth plate electrode of size 600mmx600mmx3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connect to copper strip of size 20x3mm by means of bolts, nuts check nuts and washer of copper from earth plate to body of the equipment all as shown in electrical plate No. 3 connected to earthing test point on completion with and including 40mm bore medium grade GI protection pipe (upto 7.5 mtr long) for earth and 20 mm GI medium grade for watering including PCC chamber pit & cover with suitable liffitng hooks, with funnel, wire mesh, common salt, charcoal filling necessary excavation and earth work in any type of soil complete all as specified and directed. 1.The rates for earthing includes the cost of followings: (a) Earth electrode. "(b) Main earthing lead from earth electrode to test point upto 7.5 metre" "(c) Material and labour for connecting earth electrode and earthing lead as specified." (d) Adequate quantity of charcoal dust and common salt. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) Test point and extra length of main earthing lead beyond 7.5 metres (l) Connecting lead from test point to main switch or switch board or equipment to be earthed. 2.On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost."
AC PLANT Supply , install , commissioning and testing of Water Cooled Scroll Chillers size 85 TR (2 working + i stand by), with multi compressors, comprising of Semi - Hermetic/Hermetic/ Open Type Compressors, DX Evaporator, Shell and Tube Condenser,suitable expansion device,suitable for operation on R - 134 a /R - 407 C / R - 410a refrigerants and of nominal capacity as shown Chilled water in : 12.8° C Chilled water out : 7.2° C Chilled water flow : 204 USGPM Fouling factor : 0.0001 FPS Condenser Condensor water in : 32.2° C Condenser water flow : 340 USGPM Fouling factor : 0.00025 FPS IKW shall be Max 0.75 K.W / TR(on tender condition) COP - Not less than 5.2
CHW PUMPSETS (PRIMARY) Supplying, erection, testing and commissioning of Centrifugal End suction type primary chilled/hot water pump set capable of delivering 204 USGPM of water against a head 12 Mtr. each pump shall comprise the following as required as per specifications. 1 No. - Split Casing type pump with bronze impeller, S.S Shaft, CED Coated C.I body and mechanical seal. Duly insulated with 80 kg/cum density resin bonded fiber glass cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. 1 No.- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation,IP -55 Protection,Eff-2, 1450 RPM synchronous speed, operating on 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. (2 Working + 1 Stand by )
COND. PUMP SETS Supplying, erection, testing and commissioning of Centrifugal End suction type condensor water pump set capable of delivering 340 USGPM of water against a head 15 Mtr. each pump shall comprise the following as required as per specifications. 1 No. - Split Casing type pump with bronze impeller, S.S Shaft, CED Coated C.I body and mechanical seal. Duly insulated with 80 kg/cum density resin bonded fiber glass cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. 1 No.- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation,IP -55 Protection,Eff-2, 1450 RPM synchronous speed, operating on 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. (2 Working + 1 Stand by )
Chilled Secondary Pumps (variable pumping system) Supplying, erection, testing and commissioning of package type End Suction type secondary chilled water pumping system with VFD and all pump system controller, comprising of the following: (a) Pumping set with CED Coated cast Iron casing, Bronze impellers with stainless steel shaft, connected to suitable capacity TEFC ventilated induction motor with class 'F' insulation, eff-1, 3 Phase, 1450 RPM, suitable for 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. (b) Duly insulated with 80 kg/cum density resin bonded fiber glass cladded with aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. (c) Unless otherwise specified, renewable wear ring of bronze shall be furnished atleast on the casing
(d) Variable secondary Panel should have a dedicated programmable logic controller with individual drive for each pump and with required Nos of sensors and the entire unit has to be procured from the Pump manufacturer to ensure the smooth operation of the system. The Programmable logic controller shall be able to control minimum 1 Pump and maximum of 4/6 Pumps, Automatic cascade control of pumps, automatic sequence change, Friction loss compensation. Pump status shall be there on display shall be graphical type with minimum 320 pixels X 240 Pixels VGA display with backlight.Drive should have rated input frequency 50 Hz and output frequency range of 0.5 to 132 Hz. An IP41/IP55 Nema Standard powder coated steel enclosure for Basement/Roof top, with sufficient capacity of cooling fan shall house all the electrical control components. (e) Microprocessor based control panel shall have suitable hardware & software so that it can be integrated directly to IBMS with standard communication open protocol using backnet / Modbus as well as open IP. (f) All the pump set shall have their control panel with respect to the motor rating. (g) All pumps to be provided with separate variable frequency drives. Control panel should also consist of cooling fan.
(h) One panel for each job shall be provided (for a set of two/three pumps) and the panels should be installed adjacent to each other. (j) The pumps should be suitable for heating as well as chilled water circulation. (k) Lot-Mounting frame work with anti vibration pads. (l) Electronic Differential Pressure Transmitters as required. (m) suitable flanged suction and delivery headers in C-Class MS (n) Complete set system to be mounted on a common Mild Steel base frame and shall follow following duty with following Nos of pumps of following:
Secondary chilled water pump sets Flow Rate : 204 USGPM Head : 32 Metre WC (2 Working + 1 Stand by )
Hot water pump sets Flow Rate :47 USGPM Head : 32 Metre WC (2 Working + 1 Stand by )
CHILLER PLANT MANAGER Supply, Installation, testing & commissioning of Chiller Plant Manager for systematic operation of AC plant comprising of 3 Nos. 85 TR water Cooled Chillers with VFD (2 Working + 1 Future) , 3 Nos. Primary Chilled Water pumps( 2 Working +1 Stand by ) pumps & Motorized Valves 3 Nos. Variable Secondry Chilled Water pumps with VFDs ( 3 Working +1 Stand By) pumps & Motorized Valves etc.3 Nos. Cooling Tower( 1 Working +1 Stand By) . (i) Workstation as required (Intel core i7 processor with 4 GB RAM, 1GB Graphic Card and 500GB HDD, Windows 7 64 bit.) including 21" LED Monitor, keyboard, mouse, and all required accessories complete including Latest version of MS Office and Antivirus software and as required (ii) Network superwise controller unit (Imported UL listed) for connecting all controllers to it and software integration and transfering data to P.C. The processors shall be 32 bit, 50 MHZ, suitable for to store reports and event logs & on BACnet / IP protocol (iii) Dedicated Chiller Plant manager software having inbuilt application.
(iv) Programmable controller (Imported UL Listed) having processors of 32 Bit 50 MHZ, LON CHIP) BACNET compatible/Modbus/ IP protocol, controller for Pumps,Cooling Tower . The controller shall support easy Graphical Programming and suitable for to store the programme in the controller rather than store in the PC. It should include Lockable Mounting Cabinets duly powder coated, connector strip, internal wiring & relays etc. (v) CPM should be suitable for communicate/interface with main IBMS. All required software and hardware to be provided. Any other hardwares required etc.. (vi) FIELD DEVICES & SENSORS FOR CHILLERS & PUMPS (a) Immerssion type Temperature Sensor with thermowell (b) Outside Temp. & RH Sensor (c) Level Switch (d) Flow sensor/ Flow meter (e) Differential Pressure Sensors & Differential Pressure Transmitter (for zone differential pressure sensing) (vii) LOT OF CABLES, CONDUITS & CABLE TRAY Cabling from all instruments, controls & valves to DDC and communication cabling from DDC to central equipment complete with cable gland, earthing, supports & PVC conduits. Surface laid or cable tray laid cables shall be ferruled and tagged, and shall use lugs for termination at both ends. Wherever multicore cables are used, the price shall include the cost of Marshalling Boxes (MS Powder Coated with Elmex Terminals) to connect the multicore cables to 2 core cables for termination in equipments
HOT WATER GENERATOR: Providing and installing electrically operated Hot Water Generator of following nominal capacity having 1mm thick stainless steel lining with heaters arranged in banks and controlled by electronic controller and thermostat so that following flow rate hot water at 70° C and with nominal variations could be supplied including 75mm thick fibre glass/ mineral wool/ insulation finished with 1.25mm thick G.I. sheet clading including necessary electrical panel board, having suitable incoming & outgoing switch gears for boiler and pump automatic controls including inlet and outlet connections for water, foundation for boiler as per specifications complete as required. 70 KW, 47 GPM (2 Working + 1 Stand by )
FLOOR MOUNTED AHU. Supplying, installing, testing and commissioning of factory built Floor mounted double skin type air handling units made of 45 mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8 mm outside layer and 0.8 mm plane inside layer with polyurethene foam (PUF) insulation of density 32 kg/m3 factory injected between them by injection moulding machine, complete with blower section with blower DIDW Backward curved centrifugal fan of 60 mm WC static pressure, 6 row deep cooling coil , & 2 row deep Heating coil section with aluminium finned copper tubes (tube thickness not less than 0.5mm), filter sections with 50 mm thick washable synthetic type Pre filters having efficiency 90% down to 10 micron and provision for Fine filters having efficiency 99% down to 5 micron,provision for ewating coil, belt drive package with TEFC drive motor suitable for 415 ± 10% volts, 50 Hz, 3 phase, A.C supply, complete with drain connections with drain valve, stainless steel drain pan, thermometers and pressure gauge at the inlet and outlet of the coils, necessary vibration isolation arrangement etc, complete as per specifications of following capacities: 12000 CFM , 85 TR
VFD Supply, installation, commissioning and testing of Variable Frequency Drives with IP 55 enclosures and mains disconnect switch comprising of the following: (a) Built in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the Variable Frequency Drive. (b) Built in EMC filters (electro magnetic compatibility filters) for restriction of conducted emissions to comply with IEC61800:3 (un restricted distribution) :2004 Category C 1 (50 meter). (c) Three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of the AHUs or pumps. (d) Integral graphical keypad. Note: (i) Cost of temperature sensor and control cables not included. (ii) Separate Starter not required for switching on motor and pump capacity 7.5 KW
Supplying , Installaing , Testing and Commissioning of 100mm dia dial type thermometers 0-14 kgs ratingas per the specifications.
Y- STRAINER Supply, installation and testing of Y - Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled water circulation including insulation as specified of following sizes.
40 mm dia
100 mm dia
125 mm dia
BALANCING VALVE Supply, installation and testing BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified of following sizes.
100 mm dia
125 mm dia
MOTORISED BALANCING VALVE Supply, installation and testing MOTORISED BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified of following sizes.
100 mm dia
125 mm dia
Supply and fixing of Flexible Connection (Neoprene Rubber Type) of following sizes
40 mm dia
100 mm dia
125 mm dia
Insulated M.S Closed Expansion tank of 500 Ltrs. "Supply, installation, testing and commissioning of insulated mild steel Closed Expansion tanks for chilled water shall be of M.S. construction and of adequate capacity, to contain 200% of the maximum expansion likely to take place in the system. The tank shall be insulated and be complete with valves, drain, Safety Valve, PN16 and Pressurisation Unit complete with double pump (2CMH, 25mWC), IP55 control panel, pressure transmitter, flow meter, interconnecting piping & wiring, PN16."
PRESSURE INDEPENDENT BALANCING CUM CONTROL VALVE WITH THERMOSTAT/HIGH RANGEABILITY VALVE WITH THERMOSTAT FOR AHU Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum of following sizes and capacity.
65mm dia.(300 LPM)
40mm dia.(177 LPM)
Condensate Drain Pipe Supplying, fixing, testing and commissioning of UPVC drain piping 32 mm bore dia with all fitting such as bends, tees etc. necessary clamps, adequate support duly insulated with 9 mm nitrile rubber insulation complete as per specifications and requirement.
POT STRAINER Supply, installation, testing and commissioning of Pot strainer as approved by GE.
MANUAL AIR - PURGE VALVE Supply, fixing and testing of Manual Air - purge valve of 15mm dia & complete as per specifications.
AIR AND DIRT SEPARATOR Supply, installation, testing & commissioning of Air and Dirt Separator with complete accessories suitable for 80mm dia
G. I VOLUME CONTROL DUCT DAMPER Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets,nuts, bolts, screws linkages, flanges etc, all as specified.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers all as specified.
RETURN AIR GRILL Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required
ZET DIFFUSER Supplying, fixing, testing, commissioning of Zet diffusers ( 450 mm Dia)of powder coated aluminium with aluminium volume controldampers with anti smudge ring & removable core all as specified & directed.
FIRE DAMPER Supplying, fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.
(a) Damper
(b) Actuator
M&L for PVC insulated copper conductor cable heavy duty & comprising to relevant IS to following size (a) 6 Sqmm, 4 core
(b) 4 sq.mm. 4 core
MV CABLE END TERMINATIONS Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C X 16 sq. mm (28mm)
3½ C X 50 sq. mm (35mm)
3½ C X 300 sq. mm (70mm)
Supplying and making indoor end termination with brass compression gland and Cooper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 2/3/3.5/4 CORES Copper conductor. CABLE WITH copper LUGS
4 Core X 6 sq. mm
4 Core X4 sq. mm
M&L for earthing complete with galvanised steel earth plate electrode of size 600mmx600mmx6 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connect to GI strip of size 32mmx6mm by means of bolts, nuts check nuts and washer of GI from earth plate to body of the equipment all as shown in electrical plate No. 3 connected to earthing test point on completion with and including 40mm bore medium grade GI protection pipe (upto 7.5 mtr long) for earth and 20 mm GI medium grade for watering including PCC chamber pit & CI cover with suitable liffitng hooks, with funnel, wire mesh, common salt, charcoal filling necessary excavation and earth work in any type of soil complete all as specified and directed. 1.The rates for earthing under items includes the cost of followings: (a) Earth electrode. "(b) Main earthing lead from earth electrode to test point upto 7.5 metre" "(c) Material and labour for connecting earth electrode and earthing lead as specified." (d) Adequate quantity of charcoal dust and common salt. e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) Test point and extra length of main earthing lead beyond 7.5 metres (l) Connecting lead from test point to main switch or switch board or equipment to be earthed. 2.On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost." NOTE:- On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost."
CABLE TRAY M&L for fabricating and installation of following size of perforated hot dipped G.I. cable trays made of 1.6 mm thick GI sheet including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders fixed with rawl plug and including painting with powder coating all as specified and directed by GE of following sizes:-
150 mm. Width x 50mm. Depth
300 mm. Width x 50mm. Depth
Parksons Engineering Company Pvt Ltd
NAFREF ENGINEERS PVT LTD
SVC PROJECTS PVT. LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .