Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹87,000Qualified Make: LUMINIOUS
Model: CRUZE3.5KVA WITH 4 TUBLAR BATTERIES AFL CHAK 6 BHM KANKADWALA LUNKARANSAR BIKANER RAJASTHAN 334603 | BIKANER | RAJASTHAN | 334603 | Make: LUMINIOUS
Model: CRUZE3.5KVA WITH 4 TUBLAR BATTERIES AFL | L2 | Qualified | |
| 2 | L3₹78,700Qualified Make: LUMINIOUS
Model: Luminous 3 KVA Inverter with 200 AH battery and trolley 00 AHURI AHURI MOHANGANJ RAEBARELI UTTAR PRADESH 229309 | AMETHI | UTTAR PRADESH | 229309 | Make: LUMINIOUS
Model: Luminous 3 KVA Inverter with 200 AH battery and trolley | L3 | Qualified | |
| 3 | Qualified Make: LUMINIOUS
Model: Cruze 3.5 KVA 2 year warrenty+ RC 18000 150 Ah 3 year warranty Battery with Trolley JALANDHAR PUNJAB 144008 | JALANDHAR | PUNJAB | 144008 | Make: LUMINIOUS
Model: Cruze 3.5 KVA 2 year warrenty+ RC 18000 150 Ah 3 year warranty Battery with Trolley | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
8 Jul 2018, 9:00 pmClosed
Inverter with sine wave output Inverter With Sine Wave Output ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to IS:13314 - Rating in KVA & Min. VAH Capacity of Battery 3 KVA/12960 VAH 3 KVA/12960 VAH Technology IGBT-PWM IGBT-PWM Energy Star Rating 3 Star 3 Star Trolley with trolley with trolley Type of Battery Tubular battery confirming to IS:13369 Tubular battery confirming to IS:13369 Backup time (Minutes) Minimum 180 Minutes - CONSTRUCTIONAL Thickness of sheet for trolley (in mm) minimum 1.2 - Trolley Material CRCA Steel - Type of enclosure CRCA Steel - Thickness of sheet for enclosure ( in mm) minimum 1.2 - Inverter shall have by pass facility Yes - FUNCTIONAL Total Harmonic distortion </=5% - 1/3 Input Single Phase sine wave(120 to 260 V) - Output Single Phase sine wave 240 V - Inverter Efficiency (%) >/=87% - Overload Time (in Minutes) >/=10 - Overload of rated load (in %) >/=10 - PROTECTION Battery cut-off voltage to protect from overdischarge (in Volt) >10.5 - Degree of protection IP 21 - METERING AND INDICATIONS The inverters shall be provided with output voltage and current meters conforming to IS 2419 : 1979 and of an accuracy class not inferior to 2.5 in accordance with IS 1248 : 1983 Yes - CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab Yes - Climatic test report as per clause 7.10.1 of IS 13314 yes - Type Test Certificate No. 7562 - Name of Lab SHRI LAB - Type Test Certificate date 02/08/2015 - Address of Lab NEW DELHI - Inverter shall have valid BIS CRS certifications for </= 10 KVA Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jasdeep Kaur 144102
OIC ATG
AIR FORCE STATION ADAMPUR JALANDHAR-144103 1 30 2/3 Required No ePBG Required No
276035
GEM/2018/B/39193
Inverter with sine wave output
30 days
Punjab; Jalandhar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Inverter with sine wave output Inverter With Sine Wave Output ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to IS:13314 - Rating in KVA & Min. VAH Capacity of Battery 3 KVA/12960 VAH 3 KVA/12960 VAH Technology IGBT-PWM IGBT-PWM Energy Star Rating 3 Star 3 Star Trolley with trolley with trolley Type of Battery Tubular battery confirming to IS:13369 Tubular battery confirming to IS:13369 Backup time (Minutes) Minimum 180 Minutes - CONSTRUCTIONAL Thickness of sheet for trolley (in mm) minimum 1.2 - Trolley Material CRCA Steel - Type of enclosure CRCA Steel - Thickness of sheet for enclosure ( in mm) minimum 1.2 - Inverter shall have by pass facility Yes - FUNCTIONAL Total Harmonic distortion </=5% - 1/3 Input Single Phase sine wave(120 to 260 V) - Output Single Phase sine wave 240 V - Inverter Efficiency (%) >/=87% - Overload Time (in Minutes) >/=10 - Overload of rated load (in %) >/=10 - PROTECTION Battery cut-off voltage to protect from overdischarge (in Volt) >10.5 - Degree of protection IP 21 - METERING AND INDICATIONS The inverters shall be provided with output voltage and current meters conforming to IS 2419 : 1979 and of an accuracy class not inferior to 2.5 in accordance with IS 1248 : 1983 Yes - CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab Yes - Climatic test report as per clause 7.10.1 of IS 13314 yes - Type Test Certificate No. 7562 - Name of Lab SHRI LAB - Type Test Certificate date 02/08/2015 - Address of Lab NEW DELHI - Inverter shall have valid BIS CRS certifications for </= 10 KVA Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jasdeep Kaur 144102 | - | - | - |
| OIC ATG | - | - | - |
| AIR FORCE STATION ADAMPUR JALANDHAR-144103 1 30 2/3 Required No ePBG Required No | - | - | - |
Exempted
8 Jul 2018
30 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_276035.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .