Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
23 Aug 2022, 6:00 pmClosed
GE I R and D Chandipur
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIR TO EXTERNAL ELECTRIFICATION DEHYDRATION OF TRANSFORMERS AND REPAIR TO DG SETS WITH CONECTED WORKS AND DISTRIBUTION BOX SUB MAIN AND POINT WIRING LIGHT FITTINGS EARTHING AND REPAIR TO DOMESTIC SUMMER APPLNS ALLIED WORKS UNDER AGE BALASORE
2022_MES_539930_1
8701/CDP
Open Tender
Civil Works
Item Rate
180 days
Balasore
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R and D Chandipur
₹70,000
Yes
26 Dec 2022
22 Jul 2022
25 Aug 2022
22 Jul 2022
23 Aug 2022
17 Aug 2022
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I (EXTERNAL ELECTRIFICATION)
Repair/maintenance and servicing of oil cooled step down transformer of capacity 150 to 300 KVA, comprising following work services :- (a) Disconnection of cable termination of HT & LT ends. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks. (d) Cleaning all sludges from main oil tank and conservator tank and removal off the site. (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Cleaning, polishing of serviceable bush and stud both HT/LT side and refixing the same. (g) Replacing unserviceable stud and bush as required as directed by Engr-in-Charge. (h) New silica gel requied for replacing Note :- (i) While replacing and refixing the stud and bush all nuts, washers and gaskets are to be replaced with new one against the coated rate (ii) New bushes and studs required for replacement . (h) Refixing all cable terminals HV & LV sides and transformer top cover, conservator tank in position. (l) Connecting HT & LT side with existing incoming and outgoing cables including reconnection of earth strip/lead.Note: (i) HT side cable connection shall be made with new HT tape & M Seal Monoplast. (ii) M seal monoplast required for replacement shall be deemed in coated rate. (iii) The items of work mentioned here-in-after are tentative and may vary as per site requirement as assessed by the representative and the Engn-in-Charge after strip inspection and the contractor shall have no claim on that account. (iv) Contractor wiil be very careful and should ensure not to enter any type of moisture in side the transformer during maintenance. Location: ITR Substation : 2Nos PXE Substation: 02 No OT Road- 02 Nos
Supply and refilling of transformer oil having di-electric strength not less than 50 KV after initial dehydration/filteration conforming to IS 335 and ISI marked to be brought at site in sealed container different capacity of transformers including drain out the old transformer oils all as directed.
Material and labour for painting (with spary machine) of transformers any capacity with one coat of synthetic enamel paint after and including cleaning of existing surface of all dirts and greasy materials including marking of SM/MES Nos with letters n exc 15cm height at appropriate places complete all as specified and as directed by the Engr-in-Charge. Note: The superficial area for the purpose of painting shall be considered approx 10 Sqm.
Complete servicing to the DG set comprising of the following works for the capacity 20 to 35 KVA complete all as specified and as directed by the Engr-in-Charge :- (a) Draining out unserviceable engine oil from engine, refill with new. (Engine oil will be supplied by contactor) (b) Cleaning all sludge/deposits in the oil sump and removed off the site c) Supply and replacing the primery, secondary and bi-pass fuel filters (d) Supply and replacing oil filters with gasket (e) Cleaning of air filters (f) Supply and replace unserviceable hose pipe as required at site (g) Supply and replace PVC fuel indication tube (h) Supply and replacing battery terminals (i) Cogged fan belt (j) Complete body and canopy Painting with Sprayer/compressor
Supply & Replace lead acid type wet cell battries of Capacity 180Amp/hr 12V for DG sets including taking down. Make : Exide, SF super sonic
Dismantling of HT 11 KV GOAB switch /DO fuse assembly / lightening arrestor of any type complete with all accessories complete all as specified.
Supply, fixing , commissioning and testing in replacement of outdoor type , 11 KV gang operated switch with drop out fuse assay complete of current rating upto 400 Amps 4 insulator Vertical type triple pole each pole consisting of galvanized steel based HT insulator as per IS non ferrous knife and spring loaded contacts, arching horns of adequate section to break magnetizing current of the transformers horizontol Gi of adequate length for phase separation , adequate length of GI pipe operation from ground level and operating handle with locking arrangement complete in both OFF and ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather suitable for Vertical mounting on existing structure complete all as specified and directed. Make:- Jaipuria/BHEL/Pactil
M&L for lighting arrestors expulsion type complete with all fitting, transmission class, discharge capacity 65 KA suitable for 11 KV complete with necessary connection and testing complete including taking down old U/S complete all as specified.
Material and labour for painting (with spray machine) of panel board any size at various locations with two coat of superior quality of synthetic enamel paint after cleaning of existing surface including marking of incoming feeder and outgoing feeder with letters n exc 15cm height complete all as specified and as directed. Note : The superficial area for the purpose of painting shall be considered as n exc 15 Sqm.
Supplying ,fixing danger notice plate of 1.6 mm thick mild steel sheet, with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed.
M & L for painting of RCC pole or IRON pole 7/9mtrs long and carrying out following phase of work all as directed (a) Cleaning and preparation of surface of RCC pole 9mtrs (b) Carrying out one coat cement based paint(apprx 7mtr long) © Carrying of painting with synthetic enamel paint one coat over the concrete surface of pole using Black and Yellow paint all as directed area 0.80 sqmtr(apprx) per pole including painting of brackets and clamp of any size. (d) Writing of RCC pole Number over black painted surface(0.2 sqmtr) using capital letter 10.0 cm high (5 Nos in an average for each pole)
S&F New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07, suitable for wet Location of Capacity of 60W fitting including bracket made out of GI pipe of 40mm dia light grade not less than 1.8 mtr long bent to shape, fixed to pole in any position with flat iron clamps of size 50x6 mm including taking out old unserviceable fitting complete all as specified and directed complete all as specified and directed.
Supply and fixing Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp with required size of GI Pipe/ Brackets complete. all as specified and as directed.
S& F ACP LED light signage board Size 0.9mx0.6m is made from 5 MM thick virgin glass transparent Acrylic sheet. LED Light holder is made from 2 mm thick black color acrylic sheet.illuminated (Glow) from 12 V, 8 W Coloured LED Light modules. Frame to be made up of Stainless steel 304 grade to hold the ACP LED board including earthwork and installation as direction.
Supply & draw 1.5sqmm twine core flat along with one single core flat 1.5 Sqmm flat type weather proof copper conductor cable as repair from street light to terminal box drawn through PVC contude pipe complete including taking down all as specified & as directed ( For street light connection)
S&F 7 M high hot dip galvanized iron Octogonal pole 3.0 mm wall thickness, with bottom size 130 mm diameter, top size 70mm diameter with 3mm thick base plate of size 220x220x12 mm, pole fabricating out of medium grade tapered pole octagonal cross section and shall be continuosly tapered with single longitudinal conforming to BSEN 100 25/100 27 with base plate Fe 410 conforming to IS 2062 of suitable thickness with provision of 4 Nos foundation bolts. The pole shall be galvanized as per IS 4759/BSEN1461 standards/housing with 4 way terminal block inside inbuilt junction box complete including single luminary arm 42mm diameter, 2.6mm thick, 1 Meter long, with grouting of base plate in concrete foundation as per manufacturer recommendation including excavation, earth work, refilling etc. (All poles should be prewired from Junction box to fixture with 1.5 Sqmm size of wires for Phase, neutral and Earth and provision for mounting fitting on pole) including Earth work and excavation ,necessary foundation i.e reinforcement,holding down bolts, nuts, washer of suitable size concrete etc complete pole as per manufactures instruction and standards and necessary accessories for mounting light fittings on pole.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 50 Sqmm 3½ core as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down/up existing unserviceable cable complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning will be measured and paid separately under respective item.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
S&F Street light junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings incl dismentling taking down unsv complete all as specified and directed. :- (a) Bus bar with two aluminium strips, 63 Amps capacity insulated with insulators, including colour coding, including PVC cable of suitable size from bus bar to MCB (b) Clamps made out of 25mm x 3mm flat iron duly weldedwith nuts & bolts complete all as specified and directed.
S&F Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismentling taking down unsv complete all as specified and directed.
S & F in repairs Astronomical , Multifunctional digital time switchs of 110-240 Volt AC, 50/60 Hz for Street light on/off time set complete all as directed by Engineer -In charge.
S & F in repairs Power contactor MU-2, 2 pole relay range 26-40A, 240 Volt complete all as directed by Engineer -In charge.
S&F for install of LED Flood light with PDC aluminium housing with toughned glass of IP 66 protection of cap - 60 W LED with lens Including taking down old U/S lights complete all as specified & as directed.
Supply and fix in repair LED bollard light 1.0m height fitting 10 watts IP 65 cylindrcal shaped integral decorative with polycarbonate diffuser with IP66 connection box complete with all accessories and internally prewired and necessary fixing arrangement including PCC platform by providing GI bolts complete all as specified and directed
Cutting of exsiting PCC road / hard standing / floor, etc. exc. 45 cm. and not exc. 90 cm in depth and width 45 cm (min) for laying of pipe, tubing, etc. and making good and finished & matching the disturbed surfaces with existing surfaces complete all as specified and directed.
Cutting of exsiting Bituminous road exc. 45 cm. and not exc. 90 cm in depth and width 45 cm (min) for laying of pipe, tubing, etc. and making good and finished & matching the disturbed surfaces with existing surfaces complete all as specified and directed.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Material and labour in replacement for Galvanised iron strip 32 x 6 mm burried in ground complete all as specified and directed.
Supply and fixing MCCB 4 pole,415 V,adjustable type,160 amps with breaking capcity 36 KA including taking down old one.
Supply and fixing MCCB 4 pole,415 V,adjustable type,250 amps with breaking capcity 36 KA including taking down old one.Make :
Supply and fixing MCCB 4 pole,415 V,adjustable type,630 amps with breaking capcity 50 KA including taking down old one.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3½ core as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down/up existing unserviceable cable complete all as specified and as directed by the Engr-in-Charge. Note : Earth work, brick protection and sand cushioning will be measured and paid separately under respective item.
Supply and fixing as in replacement Voltmeter, single phase, size 96x96x45 mm, 90-300 Volt AC, class - 1, input voltage measurement range 50-550 Volt AC (P-P) digital type including taking down old unserviceable one complete all as specified and as directed.
Supply and fix as in repair Digital AC ampere meter, 3 phase,auxiliary supply of 90 - 300V AC of size 96 x 96 square type , accuracy class 1.0 ,Operating Temperature 0 ºC to +55 ºC complete all as specified and as directed by the Engr-in-Charge.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down/up existing unserviceable cable complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning will be measured and paid separately under respective item.
M & L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified and directed
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION)
Taking down old Unserviceable DB including fittings/fixtures with MCBs of any make and size all as specified and directed
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 16 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 12 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
Taking down unserviceable sub main /Sub circuit wiring of any type and size including conduit, batten wiring for necessary repair/replacement.
M&L Sub main wiring using two runs of FR grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 4.0 Sqmm and one run of 4.0 Sqmm FR grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified. Note : Two runs of 4.0 Sqmm copper wire,one run of 4.0 Sqmm wire & one run PVC Conduit shall be measured as one unit.
All as per Sl item No 2.07 above but in existing Concealed Conduits
M&L Sub main wiring using two runs of FR grade PVC insulated ,unsheathed ,stranded, copper conductor cable of size 6.0 Sqmm and one run of 6.0 Sqmm grade PVC insulated, unsheathed, stranded, single core, copper wire to be drawn in and including 25 mm size PVC Conduit (medium grade) in Concealed wiring of suitable size including taking down old submain wiring with fittings & fixtures and all as specified. Note : Two runs of 6.0 Sqmm copper wire,one run of 6.0 Sqmm wire & one run PVC Conduit shall be measured as one unit.
All as per Sl item No. 2.09 above but in existing Concealed Conduits
S&F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 30 kA, 415 Volts, 63 Amps.
S&F MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 30 kA, 415 Volts, 100 Amps.
S&F MCB, SPN. 40-63 Amps rating 240, volt, 'C' series, 10 kA
Fixing only MCB SPN 6-32 Amps (Serviceable MCB obtained from respective item shall be reused).
S&F MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA
Fixing MCB SP 6-32 Amps (Serviceable MCB obtained from respective items shall be reused).
Supply and fixing Highly robust industrial Box type LED extruded Batten type indoor decorative type luminaire suitable for LED Tube 1 x 20 watt (4ft ) complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
S & F LED Polycarbonate T8 Tube with in built driver with metal heat sink double sided connection of capacity 1x 20 watts all as specified and directed.
Supply and fixing High-quality design LED Tube light fittings in extruded aluminium housing with high quality PC diffuser 1x20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories including LED tubelight internally pre-wired with capacity of 125 lumen/watt and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
Supply and fixing High-quality design LED Tube light fittings in extruded aluminium housing with high quality Milky white diffuser 1x20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories including LED tubelight internally pre-wired with capacity of 100 lumen/watt and including connecting up with twin core twisted flexible copper conductor cable including taking down old light fittings complete all as specified and directed.
S&F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings.
Fixing only lamp holder (Serviceable Lamp holder obtained shall be reused)
Supply and fixing of Step type electronic Fan regulator socket type on the existing phonolic laminated sheet etc as required as existing type and size
S & F for Ding Dong calling bell AC. 230 volts, single pole
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Material and labour in replacement for Galvanised iron strip 32 x 6 mm burried in ground complete all as specified and directed by the Engineer-in-Charge.
Taking down geyser and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete for 25 Ltr capacity complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for heating elements of 1.5 /2 KW 230 V suitable for water heater of any type including connection with suitable cable complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for thermostat switch of geyser 230 V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centi grade suitable for water heater complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for 450mm long brass CP braided hoses with 2 nuts without nipple suitable for geysers complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing as in replacement for apparatus plate , including suitable for water storage heater of 25 ltrs capacity complete all as specified and as directed by the Engr-in-Charge.
Supply and replace hermatically sealed rotary type compressure suitable for split type AC cap. 1.5/2.0 ton of make: technomush/kirloskar/ Voltas/Carrier/LG
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure.
Supply and replace starting capacitor suitable for window/split type AC cap 1.5/2.0 ton.
Supply and replace thermostate suitable for window/split type AC cap 1.5/2.0 ton of MAKE: indfass/denfoss.
Supply and replace overload relay suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace blower fan motor suitable for window/ Split type AC cap 1.5/2.0 ton
Supply and replace micro filter suitable for window type/split type AC cap 1.5/2.0 ton
Supply and replace front PVC grill suitable for window type AC cap 1.5 ton as per existing sample.
Material & Labour for taking down AC split type complete inner and outer unit and relocate as per given site complete including refixing inner & outer unit piping with insulation and testing all as directed
M/S JANAKI ENTERPRISES
ALLIANCE
M/s R.C REFRIGERATION
jlenterprise
KRISHNA ENTERPRISES
MS SUBHAM ENGINEERING AND CO
Bidder Name
ALLIANCE
KRISHNA ENTERPRISES
M/s R.C REFRIGERATION
M/SNeelachal Enterprises
jlenterprise
M/S JANAKI ENTERPRISES
MS SUBHAM ENGINEERING AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .