| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹55.9 LAccepted-AOC N A | NA | NA | 121004 | 1 | Accepted-AOC lower bid | |
| 2 | 2₹55.9 L+₹53.63 (<0.01%)Rejected-Finance DMFT MADHARGAT TATICHHARIYA PRAHAND ANTARGAT KASTURBA GANDHI BALIKA AWASIYA VIDYALAYA TATICHHARIYA | KHUNTI | JHARKHAND | 835209 | 2 | Rejected-Finance higher bid |
| Sl No | Description | Qty | Unit | M/S DEEPAK CONSTRUCTION L2 | ASHISH KUMAR MEHTA L1 |
|---|---|---|---|---|---|
| 1.00 | Providing two coats of oil bound distemper of approved shade and make over old surface including washing, cleaning and papering the walls, scaffolding, washing of floors and taxes, all complete as per building specification and direction of E/l. | 2,937.18 | M2 | 74.24 ₹2,18,055.87 Lowest | 74.24 ₹2,18,055.87 Lowest |
| 2.00 | Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) | 1,595.24 | M2 | 139.18 ₹2,22,025.5 Lowest | 139.18 ₹2,22,025.5 Lowest |
| 3.00 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 1,800.56 | M2 | 21.46 ₹38,640.08 Lowest | 21.46 ₹38,640.08 Lowest |
| 4.00 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 921.65 | M2 | 40.75 ₹37,557.24 Lowest | 40.75 ₹37,557.24 Lowest |
| 5.00 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. | 276.5 | M2 | 184.06 ₹50,891.67 Lowest | 184.06 ₹50,891.67 Lowest |
| 6.00 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. | 1,524.07 | M2 | 165.8 ₹2,52,690.47 Lowest | 165.8 ₹2,52,690.47 Lowest |
| 7.00 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/l. | 2,731.85 | M2 | 12.59 ₹34,394.02 Lowest | 12.59 ₹34,394.02 Lowest |
| 8.00 | Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. | 4 | Each | 45.12 ₹180.48 Lowest | 45.12 ₹180.48 Lowest |
| 9.00 | Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. | 17.9 | M2 | 4,283.14 ₹76,668.21 Lowest | 4,283.14 ₹76,668.21 Lowest |
| 10.00 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) | 375 | Kg | 82.31 ₹30,866.25 Lowest | 82.31 ₹30,866.25 Lowest |
Tender Value
₹55.9 L
EMD Value
₹1.1 L
Closing Date
22 May 2025, 3:00 pmClosed
EE BCD BUILDING DIVISION,HAZARIBAG
Office of the Executive Engineer, Building Construction Department, Building Division,Hazaribag
Renovation Work of Different Existing School Building at Upgrde. Middle School Saryiachatti ,Block- Padma , Dist- Hazaribag
2025_BCD_101074_1
BCD/EE/HAZARIBAG/14/08/2025-26
Open Tender
Civil Works
Item Rate
180 days
HAZARIBAG
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.1 L
12 Aug 2025
15 May 2025
23 May 2025
15 May 2025
22 May 2025
15 May 2025
Amount
Providing two coats of oil bound distemper of approved shade and make over old surface including washing, cleaning and papering the walls, scaffolding, washing of floors and taxes, all complete as per building specification and direction of E/l.
Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)
Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/l.
Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and laying 25mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime morter (1:1:1) (lime putty : surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. 600 x 600 mm size (iv) 600 x 600 mm size
Providing primer one coat of red lead paint ofapproved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I.
Providing and laying APP (Atactic olypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical andchemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Providing and laying in position cement of specified grade excluding the cost of centering and shuttering-All work up to plinthlevel 1:1.5:3(1 cement:1.5 coarse sand(zone III):3 Gradestone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm ominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including ecessary excavation,levelling & dressing & finishing the top smooth
Providing 150 mm. wide brick drain in cement mortar (1:6) with av. 125 mm. clear depth and 250 mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
Carrage of Materials (A) Sand av lead 10 K M
Carrage of Materials (B) Bricks av lead 15 K M
Carrage of Materials ( C ) Chipes av lead 15 K M
Carrage of Materials ( D ) Metal av lead 15 K M
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular type switch, modular plate, suitable size PVC/ G. I. box etc. as Group C
Wiring for light / power plug with 2 x 4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 Nos. 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for Twin Control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular type switch, modular plate, suitable size PVC/ G.I. box etc. as required.
Supplying and fixing following modular type switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 5/6 amps, two way switch
5/6 amps, 3 pin socket outlet
Wiring for Circuit/ Submain siring along with earth wire with the following sizes PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
4 x 4.0 sq. mm + 2 x 4.0 sq. mm earth wire
4 x 6.0 sq. mm + 2 x 6.0 sq. mm earth wire
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing batten/angle holder including connection etc as required
Supplying and fixing suitable size G. I. box with modular plate and cover on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.(for light
Supplying and fixing suitable size G. I. PVC box with modular plate cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc, as required.(for light
Installation, testing and commissioning of celling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing following way, three pole and neutral, sheet, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, etachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 4 way (4 + 12 ), Double Door, Horizontal type
6 way (4 + 18 ), Double Door, Horizontal type
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required. (But without charcoal or coke and salt )
Supplying and laying 6 SWG G. I. wire at 05. meter below ground level for conductor earth electrode, including soldering etc. as required.
Supplying and laying 25 mm x 5 mm G. I. strip at 0.50 meter below ground as strip earth electrode, including soldering etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G. I. tube, having single prong at top, with 85 mm dia 3 mm thick G. I. base plate including holes etc. as required.
Earthing with G. I. pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. But with charcoal and salt as required.
Reverting, swearing and soldering of copper/ G. I. tape ( with another copper / G. I. tape, base of the finial ar any other metallic object) as required.
Providing and fixing G. I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
Providing and fixing G. I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing testing joint, made of 20 mm x 3 mm thick G. I. strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, check nuts and spring washers etc. complete as required.
Providing and laying G. I. tape 32 mm x 6 mm from earth electrode directly in ground as required.
Supplying and fixing 6 amps to 32 amps rating , 240 volts, 'B' series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.6/32 amps, single pole, 'B' series
40 amps, single pole, 'B' series
Supplying and fixing following rating, four pole, 240 volts isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps
Supplying and fixing following rating, four pole, 240 volts isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 amps
S.T.C.OF Floowing rating LED street lighting luminarie with pressure die cast housing and toughened glass cover(IP 66 protection ) in existing pole/pipe for supply voltge 100-270 V AC,50Hz.Luminarie Shall be confirm ti IS:10322 part 5/section -3and shall be complete with all neccssary accessories as required 90/100 W LED Street light
Supply Installtion, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS: 374: 2019 Including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm.FR PVC Insulated copper wire suitable for 230 v 50Hz ,single phase supply etc complete as required 1200 mm (48") Ceiling fan
S.T.C.OF Floowing rating reccess /surface mounted LED tube light fitting suitable for 230v 50Hz,single phase supply etc.complete as required 15/16 Watt LED Bulb
2x20 watt tubelight
Add GST 18 %
Add L.Cess 1 %
M/S DEEPAK CONSTRUCTION (BID ID -660392)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .