Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.0 L+₹2.5 L (11.1%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹25.4 L+₹2.9 L (13.0%)Rejected-Finance BLOCK NO 7 BEHIND MALTI APTS NEAR SHIV DAIRY WANOWARI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹25.4 L+₹2.9 L (13.1%)Rejected-Finance S NO 7 3 FLAT NO 4 HILL VIEW RESIDENCY LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance High rate | |
| 5 | L5₹26.8 L+₹4.3 L (19.1%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Jun 2022, 6:00 pmClosed
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8313 SPECIAL REPAIRS TO RCC ROOF SLAB AND CHAJJAS AND OTHER WORKS OF BLDG NO P83 U BLOCK IN CADETS HOSTEL BOYS AT AFMC UNDER GE CENTRAL PUNE
2022_MES_524589_1
8313SPECIAL REPAIRS TO RCC ROOF SLAB AND CHAJJAS
Open Tender
Civil Works
Works
180 days
GE (Central) Pune
As per Tender NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Pune
₹60,000
Yes
4 Aug 2022
17 May 2022
10 Jun 2022
17 May 2022
8 Jun 2022
25 May 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises (outside of MoD Land) directed by Engr-in-Charge.
Demolition of cement Concrete in sunken portion and rubbish off the premises (outside of MoD Land) directed by Engr-in-Charge.
Taking down cement plaster on brick/ block walling including raking out joints, hacking for key, scrubbing down with water etc including necessary scaffolding etc complete.
M & L rendering 15 mm thick on brickwork or concrete surfaces in CM 1:3 with using water proofing compound in sunken portion. Note:- Water proofing compound shall be measured and paid separately at supply rate only.
M & L for applying two coats of polymeric based chemical on plastered/ concrete surfaces as per manufacturer's instructions in sunken portion etc complete. Make of Polymeric chemical as approved by GE.
Cutting holes not exc 150 Sqcm into or through brick / PCC block/stone walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
M & L Cement concrete 1:5:10 type B-2 using 20 mm graded stone aggregate in filling of sunken portion complete
M&L for 25 mm thick PCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in levelling course for floor tiling etc complete.
M & L for 450 x 300 x 6 to7 mm thick, coloured glazed vitrified tiles as in skirting/dado set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick rendering in cement mortar 1:4 on stone / brick/ concrete masonry surfaces all as specified
M&L Non skid ceramic colored tiles 7to8mm thick, (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc.set and jointed in neat cement slurry & pointed in white or coloured cement to match.including 15mm thick screed bed or bedding layer as in CM 1:6 all as specified
M & L granite ( of any type ) work ( table rubbed and polished ) 18 to 20 mm thick in steps, jambs, pillars, window cill , cooking platform and flooring in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick, in CM 1:6 on stone masonry surfaces.
M & L chamfer, splays or arris in facework to granite exc 15 mm but n exc 50 mm wide.
M&L Machine cut cudappah stone slab 20mm to 25 thick, over cement screed base laid and jointed in grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete
Demolition of stone slabs and tiles of any description of thickness in floors, aprons etc laid bedded and pointed in any mortar.
Taking up or down carefully steel tubing and connections including cleaning for refixing or removal to store of size:-
(a) 15mm dia
(b) 20mm dia
(c) 25mm or 32 mm dia
(d) 40 mm dia
Refixing old steel tubing and connections in new or old postion (wall/floor/ceilings etc) of size
(a) 15mm dia
(b) 20mm dia
(c) 40mm dia
S&F GI tubing tubes "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc.
(a) 15mm dia bore
(b) 20mm dia bore
(c) 25mm dia bore
(d) 32 mm dia bore
(e) 40 mm dia bore
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades,shelves , lintels, etc.and cutting chases for concealed water tubing and making good, cutting not exc 10 cm girth in brick walls.
S & F vitreous china wash down water closet pan , white including connection to drain ( or outgoing pipe ) and to flushing pipe with and including Plastic water closet seat,closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S & F in repairs 15 mm chromium plated 2 way bib cock fancy type with wall flange complete all as specified and directed.
S & F in repairs 15mm dia CP health faucet including flexible cod complete.
S & F in repairs CP toilet paper holder complete all as specified and directed.
S & F in repair vitreous china Urinal bowl flat back half stall type white with grating and union for discharge pipe incl waste pipe of polyethylene of low or high density or PVC 32 mm dia etc complete.
S & F in repair 15 mm dia CP push button taps fancy type, for urinals , screwed for iron pipe complete.
S&F in repair oval shaped vitreous china , under counter WHB, snow white, fancy type of overall size 560 x 430 mm, cat No FLS-WHT-5701 of Jaquar or of equivalent make specified here-in-after including 32 mm CP waste coupling, PVC waste pipe etc complete all as specified and directed by Engr-in-Charge.
S & F 15 mm bore pillar taps,fancy type , quarter turn, cat No.KUP-35001PM of Jaquar or of equivalent make specified here-in-after complete.
S & F in repairs 15 mm bore, 600 mm long PVC connections with PTMT nuts complete fixed to iron pipe at both ends complete all as specified and directed.
S & F in repairs 15 mm CP concealed stop cock with long shank with flange, fancy type complete all as specified and directed.
S&F 15mm bore chromium plated angle cock complete all as specified and directed.
S & F in repairs 15 mm chromium plated wall mixer (2-in-1) with arrangement for overhead shower complete all as specified and directed.
S & F in repairs 125 mm dia brass chromium plated shower rose including shower arm of approved quality complete.
S & F in repairs 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, including flush pipe 32 mm dia.
S & F PVC (SWR) multi floor trap of 75 mm dia of outlet with grating including jointing with solvent cement complete.
S & F chromium plated soap dish fixed to plugs with chromium plated brass screws as fixed in repairs.
S & F Transparent Glass 7.5 x 7.5 inch corner bathroom shelves with bracket (set of 2) complete all as specified and directed.
S & F in repairs brass chromium plated Tubular towel rail 20mm dia "D" type 60cm long.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) n.exc. 1.5 Sqm each.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with M.S square tube, supplying & fixing in opening as per specifications, drawings complete.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting, of frame made out of M.S tubes for top & bottom rails M.S frame shall be covered with heat molded plain co lour PVC ‘C’ channel having a PVC sheet strip of 20mm width struck inside with solvent cement for steel & plain co lour PVC sheets for top rail, lock rail& bottom rail on either side & or gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheet banding, and joints to gather with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S & F 75 mm long stainless steel butt hinges for PVC door shutters.
S&F 150 mm aluminium anodized barrel tower bolts of extruded section for door shutters.
S & F 300 mm long aluminium alloy , anodised sliding door bolt with hasp , staple( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast - aluminium alloy and fixed.
S & F 150 mm extruded aluminium alloy handles, fabricated type anodised.
S&F ventiltors/ louvers with parttially guaged shutter using 5 mm thick x 10 cm wide frosted glass strips and following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make and rubber beading etc all as directed. (a) SP 20048 (b) Glazing clips 19352
S&F two track sliding window / ventilators with two or more shutter witth 4 mm thick frosted glass , with good quality bearing, handle lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge. (a) Bottom frame 20620 (b) Top frame & Verrtical 20621 (c) Handle (side) 20606 (d) Shutter inter lock 20724 (e) Shutter top & Bottom 20844 (f) Glazing Clip 19352
Complete removal of existing treatment and M&L for applying 3 mm thick wall care putty and applying two coats of distemper oil emulsion on walls all as specified and directed.
Complete removal of existing treatment and M&L for applying 3 mm thick wall care putty and applying two coats of distemper oil emulsion on ceiling all as specified and directed.
Taking down SWR pipes, any description, (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store complete .
S & F 75 mm dia PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 110 mm dia PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 110mm PVC (SWR) WC connector complete all as specified & directed.
S & F 75 mm bore PVC (SWR) bends any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends any radius complete all as specified & directed.
S & F 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified & directed.
S & F 75 mm borePVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified & directed.
S & F 110 mm borePVC (SWR) branch piece, single (single Y) equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) junction double, (double T), equal or unequal with access door complete all as specified & directed.
M&L for 15mm thick rendering in CM 1:6 over Stone /brick / concrete wall surfaces trowelled to even & smooth w/o using extra cement for external wall surfaces including necessary scaffolding etc complete.
M&L for 15mm thick rendering in CM 1:3 over Stone /brick / concrete surfaces of chajjas top, soffit ,extended facias, etc , trowelled to even & smooth with using extra cement including Dr. Fixit water proofing chemical compound as per manufacturere's instruction including all necessary formwork and scaffolding complete all directed by Engr-in-Charge.
M & L Preparation of newly plastered surfaces and applying external wall care putty on the entire surface including filling up undulations and then sand papering the same to give smooth and even surface when surface is dry and Material & Labour for applying Two or more coats of 100% Premium exterior acrylic emulsion paint , Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 lit/10Sqm over and including priming coat of exterior primer @ 0.90 lit/10Sqm applied on surfaces of walls , cornices, borders, facia of chajjas & projected columns complete all as specified and directed. Note :- (a) Height of Bldg G+3 (b) Exterior acrylic emulsion paint shall be anit-fungal, dust resistant, water repellant, crack-bridging, weather proof type 1st Quality. (c) The work shall be caried out by the authorised applicator of the company. (d) The contractor shall furnised 05 year guarantee against efficiency of work under the above item on non judicial stamp paper of appropriate value.
Complete removal of existing treatment and applying external wall care putty on the entire surface including filling up undulations and then sand papering the same to give smooth and even surface when surface is dry and Material & Labour for applying Two or more coats of 100% Premium exterior acrylic emulsion paint , Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 lit/10Sqm over and including priming coat of exterior primer @ 0.90 lit/10Sqm on surfaces of walls , cornices, borders, facia of chajjas & projected columns complete all as specified and directed. Note :- (a) Height of Bldg G+3 (b) Exterior acrylic emulsion paint shall be anit-fungal, dust resistant, water repellant, crack-bridging, weather proof type 1st Quality. (c) The work shall be caried out by the authorised applicator of the company. (d) The contractor shall funised 05 year guarantee against efficiency of work under the above item on non judicial stamp paper of appropriate value.
Disconnecting existing water storage tanks of capacity 1000 lt ltrs setting aside, and refixng in the same position after carryout necessary roof treatment including necessary fittings and GI pipes if required including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as directed. (Note:- Necessary arrangement for water supply to be done by the contractor till completion of roof work)
Dismantling water tanks of capacity 1000 ltrs complete.
S&F 1000 ltrs capacity ,rotational moulded polythylene water storage tanks of tripple layers (cylindrical vertical with colsed top) hoisted and fixed in postion including all necessary GI fittings complete all as spd and directed .
S & F ball valves high pressure of PTMT with epoxy coated, aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule 20 mm bore complete( 210 gms weight)
S&F 40 mm dia gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified.
Removing of existing old bitumenous tarfelt (water proofing treatment) including cement screed bed and clean the surface with wire brush and washing with water to achieve the original surface of slab all as specified and directed.
Demolition of cement concrete of any description and in any position on roof slab as in padding / mud phuska etc complete all as specified and directed.
M&L for PCC 1:2:4 type BO using 12.5 mm graded agg as in PCC padding in roof kerbs or mud stops, rounded and chamfered on edges and on chajjas laid over RCC surface fineshed enen and smooth without using extra cement including necessary water proofing chemicals all as specified and directed by the Engr-in-charge.(Note: WPC shall be measured and paid separately)
Supply only integral water proofing compound ISI marked complete all as specified and as directed.
M & L water proofing treatment to RCC roof slab, walls, chajjas etc, shall be carried out as specified below and as directed by Engr-in-charge(a) M & L for 10 mm thick plaster screed bed layer in CM 1:3 on concrete surfaces (b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc and evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyster, 3mm thick weighing not less than 3.5 Kg/Sqm with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engr-in-charge, Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified and as directed by Engr-in-charge.
M & L water proofing treatment to RCC roof slab, walls, chajjas etc, shall be carried out as specified below and as directed by Engr-in-charge(a) Preparing plastered surfaces of roof edges / chajjas / chajja edges etc, by brooming with broom sweeping free from dirt dust etc and evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (b) Laying APP polymer modified approved membrane, non woven, polyster, 3 mm thick and weighing not less than 3.5 Kg/Sqm with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engr-in-charge, Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE. (c) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified and as directed by Engr-in-charge.
S & F mild steel framed work such as grills, framed guard bars etc and similar work confirming to Fe-290, grade E-165.
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome preimer complete.
Hacking out old glass from metal frame and S & F 3 mm thick Figured glass, pin head type and securing, glazing with oil putty in squares n exc 0.5 sq. m in each pane complete. Note :- (a) Height of bldg - G+3, (b) Necessary scaffolding safety equipment to labourers shall be arranged by contractor without any extra charges
Taking down old unserviceable point wiring( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants,regulators, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors, ceiling etc.complete all as specified.
Taking down old unserviceable/worn out sub main wiring of any type and size complete all as specified.
Taking down Main switches/DBs/MCb enclosure of any make and type including teakwood board, MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified.
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC casing caping 25mm wide heavy duty ISI marked including all accessories etc. with PVC modular boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:- Note:- Making good of disturbed surfaces will be done by contractor without any extra claims.
(a) One light point controlled by one switch complete all as specified and directed.
(b) OneFan point controlled by one switch complete all as specified and directed.
(c) One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board complete all as specified
(d) One 3 pin 5 amps socket outlet point on same board complete all as specified.
All as per item no 83 here in before but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sq.mm single core cable as earth and connecting to earth dolly complete all as specified for one 15 amps socket outlet point on independent board. Note:- Making good of disturbed surfaces will be done by contractor without any claims.
S & F modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F 240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 amp single pole MCB complete all as specified.
S&F ceiling rose surface type three terminals complete all as specified and directed.
M & L for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4 sqmm in and including PVC casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor and one run of PVC casing caping shall be measured as one unit length.)
M & L for Sub main wiring complete with two single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 2.5 sqmm in and including PVC casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of PVC casing caping shall be measured as one unit length.)
S&F MCB SPN DB 8 way, double door, with 200 amp rated busbar 240 V, all as specified.
S&F MCB SPN DB 4 way, double door, with 200 amp rated busbar 240 V, all as specified.
S & F for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified.
S & F for MCB double pole of rated capacity 32 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified.
Supply and fix in replacement LED Tube light fittings wall mounted, 20W LED surface and suspended compatible LED batten with extruded aluminium housing and highend non-yellowwish difuser to achive glare & flickers free illumination for continuous operation 230 V etc. including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to connector Conforming to Cat Part No. BCLSB 20 WH. Make :- Bajaj or Equivalant in other approved makes.
S&F in replacement of LED light fitting surface and wall mounted LED batten with Aluminium housing & integrated electronic driver complete in all respect of 10W cap. Cat Part No BCLSB 10 W of make - Bajaj or equivalent in other approved makes.
Parhar Enterprise
TRINITY ENGINEERS
R K CONSTRUCTION AND ENGINEERING
Sayili Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .