Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹37.0 L
Closing Date
11 Jul 2025, 8:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
DGM APCC and PROC
a.Strengthening of existing 66kV DCross-Gowribidanur1 SC line with Patridge conductor on existing lattice narrow based fabricated ungalvanised towers by SC line with Drake conductor on 110kV DC narrow based towers in the existing corridor from 220kV Gowribidanur SS to 66kV DCross SS for a distance of 36.258Kms in Gowribidnur Taluk and Doddaballapur Taluk. b. Strengthening of existing 66kV LILO line of 66kV Gundamgere SS by replacing existing COYOTE conductor by HPC conductor from Gundamgere LILO point to 66kV Gundamgere SS for a distance of 9.355kms along with replacement of 66kV line CTs at 66kV Gundamgere SS in Doddaballapur Taluk. c. Making LILO arrangement to the existing 66kV Manchenahalli SS by stringing second circuit line with HPC conductor and replacing existing SC line with Coyote conductor by HPC conductor from Manchenahalli tapping point to 66kV Manchenahalli SS on the existing 66kV Manchenahalli tap line for a distance of 9.757kms along with constrcution of 66kV TB and replacement of existing 66kV line CTs at 66kV Manchenahalli SS in Manchenahalli Taluk testing and commissioning on Total Turnkey basis and buy back of existing line released materials
KPTCL/2025-26/TL/WORK_INDENT2286
KPTCL/2025-26/TL/WORK_INDENT2286
Open
Transmission Line
Two Tender Document System(Two Cover)
KPTCL CGM Tech Corporate Office Bengaluru
6 documents required · 6 mandatory
The documentary proof of fulfilling the qualifying requirements in support of 3.2(b)(i)(ii) shall be uploaded along with the bid. The bidder shall upload the P.O, LOI/LOA, DWA, Work done certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional Engineer along with the bid
Documentary proof for Clause No. 3.2(b)(ii) of ITT such as P.O, LOI/LOA, DWA, Work done Certificates, Performance Certificates issued by the end users not below the rank of Executive/Divisional Engineer
The Manufacturer should be an ISO 9001/9002 certified manufacturer and should have a minimum experience of not less than Five (5) years as a regular manufacturer in the design, manufacture, testing and supply of High Performance Conductor (HPC) of same technology as stipulated in technical specification of the subject tender
The Manufacturer should have supplied to Indian Utilities / Consumers at least 50% of the total requirement of High Performance Conductor (HPC) i.e 58.19Km for 66kV or above Voltage Class Transmission Line(s) in the last 10 (Ten) years as on the date of Bid Submission and the same should have been in satisfactory operation for a period of at least Two years as on the date of bid submission subject to furnishing the documentary evidence like purchase orders copies executed, performance certificates issued by the end users not below the rank of Executive Engineer
The type tests certificates of Offered High Performance Conductor (HPC) not older than seven (07) years as on the last date of submission of bid conducted at following laboratories shall be uploaded. The bidder shall furnish complete list of all the type tests carried out as per latest IEC and KPTCL specifications with the offer indicating reference of relevant clauses of IEC and KPTCL specifications test description / details and date of testing along with the copies of the Type test reports
The Bidders/Tenderers can propose the names of maximum of two manufacturers for High Performance Conductor (HPC) who are meeting Qualifying requirements as per bid requirement.
Annual Turnover at Clause No. 3.2 (a), Liquid Assets at Clause No. 3.3(b) & Assessed Available Tender Capacity at Clause No.3.6 shall be met by both the Partners of Consortium Collectively such that, each of the Partners of Consortium shall meet not less than 25% of Financial Criteria specified at Clause Nos. 3.2 (a) and 3.3(b).
The Tenderer shall upload Bankers Certificate duly signed by authorized person in the prescribed format as at Annexure XVIII of Section-4 and as per the clause no.3.1 (b) of ITT (Liquid Assets and /or availability of credit facilities)
Details of Works on hand and Ongoing contractual commitments. Documentary proof for Clause No.3.6 of ITT: Assessed available tender capacity such as, Statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent or certified by Chartered Accountant /Cost Auditor and self-declaration of the Bidder as sought in Note of the said clause in the prescribed format as in clause No: 1.5 of Qualification Information
Undertaking 1 stating that, in the event of an Award, Bidder will procure Proposed HPC Conductor from the manufacturers who meet the stipulated requirements and details of manufacturers for HPC Conductor
Undertaking 2: Legally enforceable Deed of Undertaking on Rs.500/- Stamp Paper by Bidder and HPC manufacturer
Undertaking-3 stating that in the event of order, Bidder/Tenderer will conduct and submit the type test reports for offered High Performance Conductor (HPC) at his cost, at the test houses mentioned at 3.2(d) (B)(c) of ITT before commencing the deliveries without affecting the delivery schedule
Documentary proof for Clause no. 3.2(d) (B)(d) of ITT such as Calculation for the Ampacity for HPC Conductor along with supporting calculations for AC resistance as indicated in clause 1.2 and 1.3 of Technical specification for HPC conductor, GTP of HPC Conductor as per the format specified in Technical specification and Sag Tension calculations at various conditions mentioned in clause no.1.4 of Technical specification for HPC Conductor
Tenderer/Bidder in case of individual participation or both the partners of consortium in case of consortium participation shall possess Valid Super Grade Electrical Contractors License of the Bidder issued by the Govt. of Karnataka as per 2.3 of ITT
Certificate of Incorporation of the Individual or any relevant document in respect of Partnership /Proprietorship/Consortium firms as per the tender document
The bidder should have valid GST registration with GSTIN number PAN Card and ISO Certificates. Note The successful Bidder who have GST registration in other States should have GST registration in the State of Karnataka mandatorily at the time of execution of the Contract Agreement.
No Deviation Certificate as in Annexure-I
Letter of Undertaking as in Annexure-V
The Qualification and experience of key Personnel proposed for carrying out the Work
Description of the Tools & Plant available with them for execution of the Work
Undertaking to source the supply of equipment/material from KPTCL approved Vendors only as per the QR for Vendor registration, available in the KPTCL website i.e., https://kptcl.karnataka.gov.in, Link Tender and Procurement - application for Vendor registration etc
Undertaking to source the supply of equipment/material from Vendors who meet the eligibility clauses regarding restriction on procurement from a country which shares land border with India as specified in Annexure- XVII
Self-declarations of Bidder in respect of Litigation, dis-qualification due to non-performance, Risk and cost clause and Restriction on border sharing as specified in Annexure XVI and Annexure XVII as per Clause No.2.4of ITT
Details of Works on hand and Ongoing contractual commitments
Upload all relevant documents as per Section-3 Qualifying information, NIT, Terms & conditions as stipulated in the Tender Document
Copies of original documents defining the Constitution or Legal Status, place of Registration and Principal place of Business of the Bidder, written Power of Attorney to the Signatories of the Bid to commit the Bidder to the Contract along with the resolution passed in this regard by the Board of Directors / all the Partners of the Firm Both the signatories of the Consortium agreement shall be only those holding valid Power of Attorney. A certified copy by the Company Secretary/Authorised Signatory to the respective Members of the Consortium shall be attached as evidence for authentication
Bidder shall furnish a legally enforceable deed of undertaking with the manufacturer of High Performance Conductor (HPC) on Rs.500/- Non-Judicial Stamp Paper for jointly meeting all obligations under the contract for all technical support, supply, erection, testing, commissioning etc., of High Performance Conductor(HPC), required for the smooth execution of the contract and for jointly meeting all obligations under the contract to guarantee quality, timely supply, performance and warranty for successful operation of the offered High Performance Conductor(HPC) and be responsible under the contract in accordance with the requirement of the contract
₹7,500
₹37.0 L
26 Jun 2025
26 Jun 2025
12 Jul 2025
27 Jun 2025
27 Jun 2025
a. Transmission Line Erection
Check survey to be conducted during construction stage: Conducting detailed check survey along the approved route
duly following the route alignment, GPS Co-ordinates, submission of detailed line sche...
Erection of galvanised 220KV, 110KV, 66KV NBT DC Transmission Line Towers-Grand Total weight of Tower parts-HT, MS and Nut and Bolts, Note:(i) Rate to be quoted on per t Basis. (ii):For detailed quant...
Erection of Bolt & Nuts for galvanised 220KV, 110KV, 66KV NBT DC Transmission Line Towers Grand Total weight, Note:(i) Rate to be quoted on per t Basis (ii):For detailed quantity breakup refer Tec...
Stub setting templates, i. Setting of stub templates and aligning dismantling and transportation of templates from one location to another location for 66 kV
Setting of stub templates and aligning dismantling and transportation of templates from one location to another location for 110 kV
Setting of stub templates and aligning dismantling and transportation of templates from one location to another location for 220 kV
Tower accessories, 1. Supplying and fixing GI angle 450 x 450 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to f...
Supplying and fixing Barbed wire
Phase plate (Set of 3 No.)
Grounding of tower with GI Pipe including the cost of 40mm dia 2.5 mm thick, class 'C' GI pipe of 3mtrs length as per specifications, with 50x60 mm GI flats 3mtr long, salt, charcoal including excavat...
Conductor & Earth wire: 1. Drake ACSR Conductor (Plain Terrian) , Note: The tenderers are required to quote the rate taking in to consideration the charges for loading and unloading of the DRAKE ACSR ...
Conductor & Earth wire, 1. Supply of High Performance Conductor (Equavalent to current carrying capacity of Drake Conductor as per the approved specifications in the Technical Vollumes for existing T...
7/3.15 Ground wire (Plain Terrian)
Tac welding for tower bolts & nuts(No. of tower x 250)
Dismantling of existing 66 kV SC towers parts without stub, 66kV A+0, A+3, B+0, C+0 type SC tower and 66KV A+0, B+0, C+0 DC Type tower Kalpatharu Design, Note:(i) Rate to be quoted on per t Basis. (i...
Releasing of existing Patridge conductor with accessories (33.0472x3=99.141kms)
Releasing of existing Coyote conductor with accessories (9.633+49.967+29.271=88.871Km)
Releasing of existing earth wire with accessories (36.258+8.327+9.757=54.342Km)
b. Transmission Line Supply
Fabrication, Prototype Inspection and Supply of galvanised 220KV, 110KV, 66KV NBT DC Transmission Line Towers-Grand Total weight of Tower parts-HT Note:(i) Rate to be quoted on per t Basis. (ii):For d...
Fabrication, Prototype Inspection and Supply of galvanised 220KV, 110KV, 66KV NBT DC Transmission Line Towers-Grand Total weight of Tower parts-MS Note:(i) Rate to be quoted on per t Basis. (ii):For d...
Supply of Bolt & Nuts for galvanised 220KV, 110KV, 66KV NBT DC Transmission Line Towers Grand Total weight, Note:(i) Rate to be quoted on per t Basis (ii):For detailed quantity breakup refer Techn...
Tower Accessories.1.Number Plates
2.Danger Boards
3.Circuit Plate
4.Phase Plate (set of 3 Nos.)
5.Earth bond of 300mm Long
6.Earth bond of 450mm Long
Conductor & Earth wire: 1. Drake ACSR Conductor (Plain Terrian) , Note: The tenderers are required to quote the rate taking in to consideration the charges for loading and unloading of the DRAKE ACSR ...
Conductor & Earth wire, 1. Supply of High Performance Conductor (Equavalent to current carrying capacity of Drake Conductor as per the approved specifications in the Technical Vollumes for existing T...
Ground wire, i) 7/3.15mm Ground Wire
Insulator Strings with clamps, Arcing horns & hardware for Drake Conductor: 66kV line, as per Technical specifications
NOTE: All the Insulator strings quoted by the bidder shall be of the same type i...
B. Double tension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X5nos. of 90kN Disc insulators Or. b. Porcelain long rod insulator string equivalent to 1...
C. Single Suspension insulator strings consisting of any one of the following: a. Insulator string consisting of 1X4nos. of 90kN Disc insulators, Or. b.Porcelain long rod insulator string equivalent t...
D. Double Suspension insulator strings consisting of any one of the following:
a. Insulator string consisting of 1X4nos. of 90kN Disc insulators, Or. b.Porcelain long rod insulator string equivalent t...
Accessories for High Performance Conductor (HPC) for existing Towers/Supports of 700A Conductor, 1. Single Tension fitting with Terminal Pad
Double Tension fittings
Single Suspension
Double Suspension
ACCESSORIES FOR HTLS Coyote Conductor, a) Mid span compression joint
b) Repair sleeves
c) Vibration Dampers
d) Clamps for Drake ACSR to HPC conductor
e) 66KV 90KN Single tension compression type polymer long rod insulators for Coyote conductor
f) Vibration dampers for Coyote ACSR Conductor
Accessories for Drake Conductor:
1.M S C Joints for Drake Conductor
2.Repair sleeves for Drake Conductor
3.P G Clamps for Drake Conductor
4.Vibration dampers for Drake ACSR Conductor
5.Preformed armour rods Drake (03nos per tower)
Accessories for Earthwire(7/3.15mm):
1.M S C Joints for Earth Conductor
2.Repair sleeves for Earth Conductor
3.P G Clamps for Earth Conductor
4.Single tension clamps (compression type)
4.SuspensionClamps
c. Transmission Line Civil
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution li...
Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, includin...
Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, includin...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tyin...
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
CIRCUIT BREAKER: SF-6 gas circuit breakers with semi pneumatic/pneumatic operated/Spring type operating mechanism, including mounting structure arrangements with rigid, bi-metallic terminal connectors...
ISOLATORS : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators. 66kV, 1250A, 40kA class double...
b.Upright mounting type without Earth switch LPH 4600mm
CURRENT TRANSFORMER: Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor, 1. 66kV class, 31...
2. 66 kV class, 31.5 kA, CT of ratio 1000-800-600-400 /1-1-1 A for tr line. For metering : Accuracy 0.2S, Burden 10VA
For backup protection : Accuracy 5P20. Burden 30VA, For differential /Distance pro...
SURGE ARRESTOR: (Procelain housing) metal oxide, Gapless type as per technical specification, 60kV, 10kA, class - II, Note:For detailed quantity breakup refer Techno-commercial sheet.
Relay & protection Panel: Simplex type control and relay panels complete as per specifications compatible with, For 66kV Transmission line, Note: 1. proposed C&R Panel and associated panels shall be i...
Materials for new bay integration to existing SCADA panel. i. Multi Functional Transducer (MFT) 0.2S class including labour
Opto Coupler (220 or 110V DC) including labour
Contact multiplier relay
terminal block (knife type)
Current Cable-Copper core with 4.0sqmm cross section mutlistrand 7 core for CT Termination
Voltage Cables-Copper core with 2.5sqmm cross section mutlistrand 4 core for PT Termination
Signal/communication Cables-Armoured copper core with 0.5sqmm cross section mutlistrand 10core
Control Cables- copper core with 1.5sqmm cross section mutlistrand 10core
RJ-45 cable for Energy meter integration to DCU
Station Structures: 66kV side station structure fabricated out of galvanised mild steel including bolts & nuts.
i. Station Towers (6T1)(0.956 MT/tower)
Station beams (6B1)(0.504MT/beam)
GI MOUNTING STRUCTURES including Bolts & Nuts
1. 66kV Isolator Live point height 4600 mm . (0.532 MT per Structure) for existing 66 kV PT
66kV Current transformer (0.158MT per Structure)
66kV Lightening Arrestors.(0.116MT per Structure)
66 kV Pedastal Insulators (0.14MT per structure).
BUS BAR FORMATION: a. Drake ACSR
Earth wire 7/3.15mm steel with clamps/lugs
Insulator, i) Post insulators- Cylindrical solid core as per technical Specification, Solid Core Bus Post Insulator 66 kV class, 1Unit/stack
HARDWARES:1.C Type wedge connector suitable for Drake-Coyote
2.C Type wedge connector suitable for Drake-Drake
3.Post insulator clamp suitable for Single Drake ACSR and 66kV solid core insulator
A.C. Distribution Box (Outdoor): AC Distribution Box Single front (Outdoor type) 6 Terminal, one I/C of 100A MCCB 20kA + 6O/G MCB 16A + 1O/G of 100A, HRC fuse, complete as per technical specification.
DC Distribution Box(Indoor Type) as per the Technical specification comprising of Earth fault indicator, Indication circuit for AC Main failure with one no of 100A Sfu for 1C+12nos, 32A SFU for OG etc...
LTAC Panel (indoor),415 V as per technical specification comprising of voltmeter and ammeter, 1No. I/C MCCB 200A + 2 nos. 3 Phase 63A O/G SFU + 2nos. 3 Phase 32A O/G SFU + 14O/G SFU, 6 nos. 3 Phase 16...
LT POWER ARMOURED UG CABLE as per specification: i. 1.1kV PVC insulated 95Sq.mm Aluminium cable, 4 Core with glands / lugs/ ferrules
1.1kV PVC insulated 25Sq.mm Copper cable, 4 Core with glands / lugs/ ferrules
1.1kV PVC insulated 10Sq.mm Copper cable, 4 Core with glands / lugs/ ferrules
Copper control cables:
1.1kV class PVC insulated Copper Control Cable with Lugs / Ferrules, Glands as per technical specificaions, i) 19 Core x 2.5 Sq.mm.
ii) 4 Core x 6.0 Sq.mm.
iii) 4 Core x 2.5 Sq.mm.
v) 2 Core x 2.5 Sq.mm.
vi) 2 Core x 6 Sq.mm.
Miscellaneous items like rubber mats, (size/capacities to be got appfoved), 1.Rubber mats 1000mm x 2000mm x 12mm size tested for 15kV class.
2. Equipments name plates and earthing name plates including fixing at outdoor yard
CIRCUIT BREAKER: SF-6 gas circuit breakers with semi pneumatic/pneumatic operated/Spring type operating mechanism, including mounting structure arrangements with rigid, bi-metallic terminal connectors...
ISOLATORS : Isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators. 66kV, 1250A, 40kA class double...
b.Upright mounting type without Earth switch LPH 4600mm
CURRENT TRANSFORMER: Current Transformer including Marshalling box, Single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for Drake ACSR conductor, 1. 66kV class, 31...
2. 66 kV class, 31.5 kA, CT of ratio 1000-800-600-400 /1-1-1 A for tr line. For metering : Accuracy 0.2S, Burden 10VA, For backup protection : Accuracy 5P20. Burden 30VA, For differential /Distance pr...
SURGE ARRESTOR: (Procelain housing) metal oxide, Gapless type as per technical specification, 60kV, 10kA, class - II, Note:For detailed quantity breakup refer Techno-commercial sheet.
Relay & protection Panel: Simplex type control and relay panels complete as per specifications compatible with, For 66kV Transmission line, Note: 1. proposed C&R Panel and associated panels shall be i...
Materials for new bay integration to existing SCADA panel. i. Multi Functional Transducer(MFT) 0.2S class including labour
Opto Coupler (220 or 110V DC) including labour
Current Cable-Copper core with 4.0sqmm cross section mutlistrand 7 core for CT Termination
Voltage Cables-Copper core with 2.5sqmm cross section mutlistrand 4 core for PT Termination
Signal/communication Cables-Armoured copper core with 0.5sqmm cross section mutlistrand 10core
Control Cables- copper core with 1.5sqmm cross section mutlistrand 10core
RJ-45 cable for Energy meter integration to DCU
Station Structures: 66kV side station structure fabricated out of galvanised mild steel including bolts & nuts. i. Station Towers (6T1)(0.956 MT Per tower)
Station beams (6B1)(0.504MT/beam)
GI MOUNTING STRUCTURES including Bolts & Nuts
1. 66kV Isolator Live point height 4600 mm . (0.532 MT per Structure) for existing 66 kV PT
66kV Current transformer (0.158MT per Structure)
66kV Lightening Arrestors.(0.116MT per Structure)
66 kV Pedastal Insulators (0.14MT per structure).
Bus Bar Formation: c. Formation of main/cross bus using single Drake ACSR
Insulator and Clamps: i. Post Insulator solid core 66kV Side 1 Unit/Stack
A.C. Distribution Box (Outdoor): AC Distribution Box Single front (Outdoor type) 6 Terminal, one I/C of 100A MCCB 20kA + 6 O/G MCB 16A + 1 O/G of 100A, HRC fuse, complete as per technical specificatio...
DC Distribution Box(Indoor Type) as per the Technical specification comprising of Earth fault indicator, Indication circuit for AC Main failure with one no of 100A Sfu for 1C+12nos, 32A SFU for OG etc...
LTAC Panel (indoor),415 V as per technical specification comprising of voltmeter and ammeter, 1No. I/C MCCB 200A + 2 nos. 3 Phase 63A O/G SFU + 2 nos. 3 Phase 32A O/G SFU + 14O/G SFU, 6 nos. 3 Phase 1...
LT POWER ARMOURED UG CABLE as per specification: i. 1.1kV PVC insulated 95Sq.mm Aluminium cable, 4 Core with glands / lugs/ ferrules
1.1kV PVC insulated 25Sq.mm Copper cable, 4 Core with glands / lugs/ ferrules
1.1kV PVC insulated 10Sq.mm Copper cable, 4 Core with glands / lugs/ ferrules
Copper control cables: 1.1kV class PVC insulated Copper Control Cable with Lugs / Ferrules, Glands as per technical specificaions, i. 19 Core x 2.5 Sq.mm.
ii) 4 Core x 6.0 Sq.mm.
iii) 4 Core x 2.5 Sq.mm.
v) 2 Core x 2.5 Sq.mm.
vi) 2 Core x 6 Sq.mm.
Earth Mat Formation:1. Grounding of equipments with 50 x 6mm G I flat and connecting equipments to the earth mat/ground pit including all connected works with all materials supplied by the contract...
Providing C.I. Pipe of 100mm ID 13mm thick 2.75mtr. long with 2 part GI Flat 50x6mm clamp welded allround the pipe etc., including cost of excavation
Supplying and fixing 450mm dia x 450mm height 1.5" to 2" Hume pipe collars for earth pits.
Releaseing of existing CTs (Existing CT ratio 400-200/1-1-1A). Gundamgere sub-station-6 Nos and Manchenahalli sub-station - 3 Nos
Earth work excavation by manual means for drains, canals, waste weir, draft,approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per draw...
Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per dr...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
Form Work for foundation
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by r...
Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/w...
Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work
Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plaster...
Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete...
g. Buy Back of Released line Materials
Existing Scrap Towers Parts / Super Structures of MS, A. Released existing super structure/ tower materials of MS without stubs at 66Kv D Cross - Gowribinur Line under buy back, a. 66kV SC A+0 Type T...
Released Scrap Patridge Conductor under Buy Back.
Released Scrap Coyote Conductor under Buy Back.
Released Scrap Ground Wire under Buy Back.
Released 90KN Scrap Porcelain Disc Insulators Per insulator basis under buy-back. i. 90KN Disc Insulators (Single Tension Strings)
Released 90KN Scrap Porcelain Disc Insulators Per insulator basis under buy-back. ii. 90KN Disc Insulators (Double Tension Strings)
Released 70KN Disc Insulators (Single Suspension Strings)
Released hardware materials like Ball & eye sockets, single tension clamp, single suspension clamp etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Circular for sand.pdf
Tender Document • 0.06 MB
Pre Bid Meeting Proceedings and Quary Reply.pdf
Others - Pre bid meeting proceedings and bidders query reply • 0.38 MB
Detailed Survey (2).pdf
Others - Detailed survey reports • 4.70 MB
TECHNI~2.DOC
Technical Information / Worksheet • 0.03 MB
Revised NIT.pdf
Others - Revised NIT as per SBD • 1.33 MB
Cirular for acceptance of TypeTest of ERDA.pdf
Tender Document • 0.07 MB
DPR OM.pdf
Others - DPR OM Copy • 0.17 MB
SECTION-X.doc
Technical Information / Worksheet • 0.12 MB
NIT.pdf
Instructions to Tenderers • 1.03 MB
SECTION-VII & VIII.docx
Technical Information / Worksheet • 0.09 MB
SECTION-IX.docx
Technical Information / Worksheet • 0.05 MB
Tender Doc Final.docx
Tender Document • 0.90 MB
Technical Specification for HPC (700A).docx
Technical Information / Worksheet • 0.15 MB
SECTION-II.docx
Technical Information / Worksheet • 0.03 MB
QR Amendment.pdf
Others - QR amendment copy • 1.52 MB
SECTION-I.docx
Technical Information / Worksheet • 0.04 MB
SECTION-III.docx
Technical Information / Worksheet • 0.10 MB
vendor approval Guidelines.pdf
Tender Document • 0.95 MB
KPTCL e BG circular.pdf
Tender Document • 0.23 MB
SECTION-VI.doc
Technical Information / Worksheet • 0.44 MB
Revised Tender Doc Final.docx
Tender Document • 0.93 MB
SECTION-IV&V.docx
Technical Information / Worksheet • 0.12 MB
Revised Techno-Com Sheet Final.xlsx
Techno-Commercial Worksheet • 0.67 MB
Advisory Note to Bidders.pdf
Tender Document • 1.02 MB
Revised Tender Doc Final.docx
Others - Revised tender Documents • 0.73 MB
Circular for Vendor Approval labaratories for Drawing GTP etc.pdf
Tender Document • 0.35 MB
Detailed Survey (1).pdf
Others - Detailed Survey cover Letter • 0.12 MB
TECHNI~3.DOC
Commercial Information / Worksheet • 0.12 MB
KPTCL Revised stamp duty circular.pdf
Tender Document • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .