CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
REPAIRS AND PERIODICAL MAINTENANCE OF CERTAIN PACKAGE TYPE AC PLANTS AND COLD STORAGE PLANTS AT AFA HYDERABAD
2023_MES_626081_1
86727/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AFA HYDERABAD
₹60,000
Yes
3 Jan 2024
1 Nov 2023
6 Dec 2023
1 Nov 2023
4 Dec 2023
15 Nov 2023
1 Nov 2023 - 10 Nov 2023
Amount
M&L for servicing of compressor unit with blower unit (Package Type AC plant and servicing whole chamber, blowing out the dust, rectifying the minor problems, checking of interlock of safety/ control device, checking of all electrical connections in unit, refrigerant pipe lines, renewal of all corroded sheet metal screws, servicing of blowers, cleaning of evaporator coils washing with chemicals with forced feed method to remove the dust from the coil and filters, greasing the blower fan bearings, alignment of the blower and shaft, adjustment of the 'V' belts tension, tightening the nuts bolts, including replacement of damage trucking canvas with zip as per old of the following capacities of Package type AC plants complete all as specified and directed by EIC. Note:- Small repair work related to servicing part (if any) shall be included in the scope. No extra payment shall be admissible for that account.
Set of 1 x 5.5 TR Capacity
Set of 2 x 5.5 TR Capacity
Set of 3 x 5.5 TR Capacity
Set of 2 x 8.75 TR Capacity
Set of 3 x 8.75 TR Capacity
Set of 3 x 11.0 TR Capacity
M&L for complete servicing the condensing unit (Package Air conditioning unit), with and including dismantling the condensing units sheet metal body, blowing out the dust, spraying the organic based scale removing agent at the appropriate ratio to the condenser fan area, till removal of complete scales & dust, flushing through for proper air flow across the coil, checking of all electrical connections, greasing of motor bearing, renewal of all corroded sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion in inner body, reassembling the sheet metal parts, and testing the unit all as specified and as directed by Engineer-in-Charge. Note:- Small repair work related to servicing part (if any) shall be included in the scope. No extra payment shall be admissible for that account.
Set of 1 x 5.5 TR Capacity
Set of 2 x 5.5 TR Capacity
Set of 3 x 5.5 TR Capacity
Set of 2 x 8.75 TR Capacity
Set of 3 x 8.75 TR Capacity
Set of 3 x 11.0 TR Capacity
M&L for leak testing of the total refrigerant system of Package type AC plants by pumping down the refrigerant to cylinder, flushing out the entire system arrest all leakages by replacing the damaged flare nuts, taflon washers, brazing, gaskets, o rings etc and leak test by supply and charging with Nitrogen gas ( N-2) under constant pressure of 250 - 300 PSI , watching the pressure for 24 Hrs for confirmation, flushing out the system vacuumising and charge the required qty of refrigerant and lubricant testing and commissioning the system all as directed for the following capacity of plants (Note: Refrigerant & compressor oil shall be measured and paid separately under respective items)
Set of 1 x 5.5 TR Capacity
Set of 2 x 5.5 TR Capacity
Set of 3 x 5.5 TR Capacity
Set of 2 x 8.75 TR Capacity
Set of 3 x 8.75 TR Capacity
Set of 3 x 11.0 TR Capacity
M&L for taking down unserviceable hermetically sealed compressor after disconnecting the suction/delivery lines and Supply & fixing hermetically sealed compressor of following capacities as per existing make, model & specification, including pressure testing, vacuumising and charging of refrigerant, testing and commissioning all as directed Make : Copeland/Danfoss/kirloskar/Blue star/Voltas (As per site requirement)
5.5 TR Capacity
8.75 TR Capacity
11.0 TR Capacity
Note: Refrigerant will be measured and paid separately
S&F liquid line filter drier as per existing make & specification and suitable size to fixing with existing refrigerant line for 5.5 TR to 8.75 TR capacity compressor of AC Plant including taking down unserviceable liquid line filter drier all as specified and directed by the Engr-in-charge
S&F liquid line filter drier as per existing make & specification and suitable size to fixing with existing refrigerant line for 11 TR capacity compressor of AC Plant, including taking down unserviceable liquid line filter drier all as specified and directed by the Engr-in-charge
Removing the worn-out unserviceable blower motor following capcity of AC Plant from the position after disconnecting the electrical connections and transporting to the work shop and opening the end covers, removing the unserviceable winding, clean the slots with CTC, rewind the motor by super enameled copper winding wire of suitable gauge and size with insulating paper, insulating varnish and drying for obtaining requisite insulation values complete with necessary PVC sleeves, lead wire, new terminal block complete and bring back and install in position including testing and commissioning all as directed
upto 3 HP capacity
5 HP to 7.5 HP capacity
Supply and fixing blower motor V-belt as per existing same Model & specification and suitable size to fixing with existing system for 5.5 TR/ 8.75/ 11 TR capacity Package unit including taking down unserviceable blower motor V-belt and all as specified and directed Make:- FENNER/DUNLOP/NIRLON
M&L for Repair/Servicing microprocessor based control panel with display including replacing wornout u/s single/three phase controllers, contractors, fuse, internal wiring as per existing same model & specification and suitable size to Package unit of AC Plant, all as specified and directed
S&F in replacement microprocessor based control panel alongwith single phase controllers, contractors and LED display as per existing same model & specification, controlling for condensing unit, compressor unit & blower of following units to Package type AC plant, all as specified and directed Make:- Voltas/Bluestar/LG
5.5 TR Package Unit
8.75TR Package Unit
11.0 TR Package Unit
Cold Storage 15000 BTU, (+ / -10°C) capacity
M&L thermal insulation with aluminium faced nitrile rubber 12 mm thick for duct/blower unit as per existing density and thermal conductivity including packing material for the 5.5 TR to 3 x 11TR capacities of Package type AC plants complete all as specified and directed by EIC. Make- Armaflex / Aeroflex / Thermobreak
M&L nitrile rubber tubular insulation for copper tubing as per existing density and thermal conductivity including packing material, aluminium sheet cover and PVC tie for the 5.5 TR to 3 x 11TR capacities of Package type AC plants complete all as specified and directed by EIC. Make- Armaflex / Aeroflex / Thermobreak
S&F copper refrigerant tubing for the following sizes (outer dia) including suitable joints / branch connectors and distributers with flare nuts/brazing for indoor & outdoor units as required at site complete including removing the chocked unserviceable copper refrigerant tubing all as specified and as directed.
6.4 mm to12.7 mm
15.9 mm to 22.2 mm
25.4 mm to 28.6 mm
M&L for rigid PVC conduit (medium grade) size 32 mm dia for water drain out line for Package type AC plant, laid on walls, ceiling, in floors with clamping/fixing mtrls complete all as specified and directed.
All as per item 14 above but size 40 mm dia.
M&L for preparation of surfaces by scrapping and removing rusted portion with wire brush and applying one coat of Red-oxide primer and two coats of synthetic enamel paint by spray method of the following capacities Package type AC Plant complete all as specified and directed
Set of 1 x 5.5 TR Capacity
Set of 2 x 5.5 TR Capacity
Set of 3 x 5.5 TR Capacity
Set of 2 x 8.75 TR Capacity
Set of 3 x 8.75 TR Capacity
Set of 3 x 11.0 TR Capacity
S&F thermostat switch of range -5 to +25 degree centigrade of following capacity 5.5 to 22 TR including removing the unserviceable thermostat switch all as directed by the Engr-in-charge
S&F thermostat expansion valve of following capacities including cutting and brazing complete including removing the unserviceable thermostat expansion valve from the evaporating unit all as specified and directed by Engr-in-charge.
5.5 TR Capacity
8.75 TR Capacity
11.0 TR Capacity
M&L for repairing the Cold Storage Room PVC wall and ceiling by replacing u/s PVC insulated panels made up of expanded polyesterene (EPS) stuck to 2mm thick PVC sheet with PVC strip/aluminium frame and repairing insulated door, by replacing door beading, repair to door lock etc. all as required at site and as directed by Engr-in-Charge.
M&L for servicing / overhauling to complete indoor/outdoor (Cold Storage plant) labour only for overhauling and servicing whole chamber, blowing out the dust, rectifying the problems, checking of interlock of safety/ control device, checking of all electrical connections in unit, refrigerant pipe lines, renewal of all corroded sheet metal screws, servicing of blowers, cleaning of evaporator coils washing with chemicals with forced feed method to remove the dust from the coil and filters, greasing the fan including leak testing of the total refrigerant system of plants by pumping down the refrigerant to cylinder, flushing out the entire system arresting all leakages by replacing the damaged flare nuts, taflon washers, brazing, gaskets, o rings etc and leak test by supply and charging with Nitrogen gas ( N-2) under constant pressure of 250 - 300 PSI , watch the pressure for 24 Hrs for confirmation tightening the nuts bolts, of the following capacities of Cold Storage Plant plants complete all as specified and directed by EIC.
Cold Storage 15000 BTU, (+10°C) capacity (Room No 1 & 3)
Cold Storage 15000 BTU, (-10°C) capacity (Room No 2)
Cold Storage 20000 BTU, (+10°C) capacity (Room No 4)
Cold storage 2 x 2 HP ( Eva -23.3°C to -28.0°C) capacity
Note for item No. 20 above:- Servicing shall have to be carried out in an interval of every six months( Atleast 2 times during the currency of the work)
Supply and top up Compressor oil of suitable grade in the refrigeration compressor to the requisite level complete all as directed Make: Freezol/servo freeze
Supply and filling/topping up/ charging of Refrigerent gas R-22 for Central/Package type ACs complete all as directed.
Supply and filling/topping up/ charging of Refrigerent gas R-407 for Central/Package type ACs complete all as directed.
Supply and filling/topping up/ charging of Refrigerent gas R-404 A for Central/Package type ACs complete all as directed.
Supply and filling/topping up/ charging of Refrigerent gas R-410 for Central/Package type ACs complete all as directed.
Dismantling and taking down existing unserviceable submain wiring from batten/conduit of any size and making good to disturbed surfaces to match the existing surfaces.
M&L for submain wiring with 4X10.0 SQMM + 2x10.0 SQMM Earth Wire single core PVC insulated FRLS sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC casing caping/conduit pipe as per direction , all accessories complete all as specified and directed. Note:- 6 run copper wire and 1 run casing caping/conduit pipe shall be measured as unit length.
M&L for submain wiring with 4X16.0 SQMM + 2x16.0 SQMM Earth Wire single core PVC insulated FRLS sheathed cooper cable connecting to common earth dolly in and including heavy duty PVC conduit pipe as per direction , all accessories complete all as specified and directed. Note:- 6 run copper wire and 1 run conduit pipe shall be measured as unit length.
S&F CRCA Sheet metal enclouser with provision to mount MCB/Isolator/RCCB etc, suitable for use on 415 V, 50 Hz supply, metal door IP 20, 4 way for 4 Nos modules including taking down old u/s. Make:-Standard/L&T /Legrand .
MCCB 100 Amps ,415 volt ,35 kA Breaking capacity, fixed magnetic & adjustable thermal setting 4 pole incl all termnials, fitting etc . Make:-Standard/L&T /Legrand .
S&F MCB Four Pole 40 Amps 415V incl all termnials, fitting etc. Make:-Standard/L&T /Legrand .
S&F MCB Changeover two way centre off switch FP, 40 Amps 415V incl all termnials, fitting etc. Make:-Standard/L&T /Legrand .
S&F in replacement for the following unserviceable spare parts for Package type AC plants of any make & model all as specified and directed
Contactor rated current AC 3, 9 Amps, coil voltage 230 V AC, 50Hz, capacity as per existing specification
Contactor rated current AC 3, 18 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification
Contactor rated current AC 3, 25 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification
Relay switch of range 4 to 6.5 Amps
Relay switch of range 6 to 10 Amps
Relay switch of range 9 to 14 Amps
Relay switch of range 13 to 21 Amps
LED Indicator lamps of colors R / Y / B
HRC fuse 2.5 to 10 Amps
HRC fuse 16 to 32 Amps
K LAKSHMAN SINGH AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .