| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹16.5 L+₹2,810 (0.17%)Rejected-Finance | L2 | Rejected-Finance Other than L1 After deducting schedule of credit Rs 52553.00 | |
| 3 | L3₹18.1 L+₹1.6 L (9.91%)Rejected-Finance BHARDA KALAN P O TEH AKHNOOR DISTT JAMMU J K | AKHNOOR | JAMMU | JAMMU AND KASHMIR | 181201 | L3 | Rejected-Finance Other than L1 After deducting schedule of credit Rs 52553.00 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
31 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Akhnoor
GE North Akhnoor PIN 181201 CO 56 APO
COMPREHENSIVE REPAIR OF BR EM NATURE OF WORK FOR ZONE B AT RLT VIHAR MD ACCN UNDER GE NORTH AKHNOOR
2022_MES_542801_1
GE(N)/AKH-45/2022-23
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
Class D Cat a i b i
8 documents required · 8 mandatory
₹500
Yes
GE North Akhnoor
₹50,000
Yes
8 Dec 2022
3 Aug 2022
2 Sept 2022
3 Aug 2022
31 Aug 2022
17 Aug 2022
60 days
Amount
Taking down old treatment incl padding, sunken floors ,removing existing bitumen felt treatment incl brushing,cleaning top surfaces of roof slab, broming etc complete all as specified.
M&L for rendering 10mm thick cement plaster with cement mortar(1:4) on fair finishes of brick work or concrete surface of roof slab all as specified.
Sunken Floor treatment :- (a) Apply a coat of biruminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepardd surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to (IS-702 @ 1.20 Kg/Sqm of surfaces. (c) Provide APP modified polymeric five layed membrane with central core of 100 micron high molecular high density film. Minium width of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi p[lus manufactured by M/S STP texa Ltd Gurgoan/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slop from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown. (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as perIS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bvitumen coat. (e) Coved fillet in PCC (1:2:4) type BO radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6. Note :-Concrete for sunken slabs shall be mixed with WP compounds as manufacturing instructions before carrying out water proofing treatment the sunken slab slab shall be tested with water for 48 hrs for any leakage/dampeness is seen in ceiling below, then treatment is again carried out to RCC slab and it is again tested ( Water proof compound rate is not paid seperatly.)
Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc.
M&L for rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement .
M&L for rendering 10 mm thick cement plaster with cement mortar(1:6)on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement.
M & L provinding 1mm thick wall care putty on internal walls.
M&L for rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement.
M&L for preparation complete removal of exising treatment of old surfaces.
M & L Perparatrion of newly/Old plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer all as speicfied and directed.
M&L for preparation of new surfaces and apply two coat of cement base paint to walls.including one coat of cement primer.
M&L for preparation of old surfaces and apply two coat of cement base paint to walls.including one coat of cement primer.
M& L for preparation of new /Old treated surface and apply two coat of Oil bound distemper on ceiling.
S&F curtain rail ,20 mm dia Stainless steel ,cromium plated fixed with braket, incl taking down of old curtain rods, all as directed.
Providing cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight).
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete.
Taking up or down steel water tubing and connections of following descriptions :-20mm.
Taking up or down steel water tubing and connections of following descriptions :-15 mm.
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of following descriptions :-20 mm.
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of following descriptions :-15 mm .
S&F stop valves cast copper alloy serwed down high pressure ,15 dia bore fixed in repairs.
S&F stop valves cast copper alloy serwed down high pressure with crutch or butterfly handle 20mm dia bore fixed in repairs.
S&F ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia bore fixed in repair.
PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs.
S&F vitreous china squtting pan "Orissa Pattern" size 580 x 440 mm in any coloured with integral foot rest incl lime motor, 'S' trap and complete all as specified, fixed in repairs.including taking down all as specified.
S&F PVC connection 15 mm size with PTMT nuts 450 mm long fixed in repair.
S & F Stainless steel gratings 100mm dia with hole and fixed with cement motar fixed in repair.
S&F Swivel shower of PTMT any colour for fixing with 15 mm pipe ,with shower arm of size 195 mm long with bend of 54 digree with flange of any colour (minimum weight 40 gm), supplied and fixed in repairs complete.
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), includding all fittings, heads , shoes bends , swan-necks etc . All as specified.
S & F 110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber joints fixed in floors etc all as specified and directed.
S&F PVC Bends (any radius) diminishing pieces or tapers (larger bore measured) for pvc pipes, 75 mm bore complete all as specified and directed.
S & F PVC branch piece , single (Y)ipes 110mm single equal or unequal ordinary or inverted (spigot or socket type) with access door with paralled branches all as specified and directed.
S & F PVC branch piece, 75 mm double (Y) equal or unequal ordinary or inverted (spigot or socket type) with access door with paralled branches all as specified and directed.
S & F PVC SWR Type-B (pressure not less than 6 Kg/cm2) cowls 110mm fall as specified directed.
S & F PVC SWR Type-B (pressure not less than 6 Kg/cm2) cowls 75mm fall as complete all as specified.
S & F PVC (SWR) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified.
S & F fixed in repair Plate rack made of stainless steel 0.8mm thick overall size 786mm x 610mm x 254mm complete all as specified and directed.
S & F kitchen sink bowl with drainage board gloss finishing stainless steel 1.00 mm thick sheet for kitchen with plugs, washers and wastes including fixing in reinforcement cement concrete slab and connecting union to pipe overall 510 x 430 x203 supplied and fixed in repairs with complete fittings all as specified and as directed by Engineer-in-Charge.
S & F CP angle valve/concealed stop cock of cast copper alloy (ISI Marked) chromium plated fancy type scrwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore incl add if fixed in repairs complete all as specified and directed.
S & F Bib taps (Long body) , fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified.
S & F CP Brass wall mixture with Telephonic shower arrangement for mixing hot cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type fixed in repair complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches , pillars etc.
M&L Brick work with sub class 'B' bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6
S&F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm complete all as specified and directed.
S&F Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
S&F Steel windows/ventilator (Box type) factory made without glazing bars shutter only complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
S&F Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed in repairs.
S&F Glazing with sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane.
S&F figured glass sheet, 4mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane.
Dismantling of wall and ceiling boards ( fibre ,pulp, insulation,etc,) or insulation boards/slabs/blankets any thickness,including cover fillets.
GI frame work 605 x 605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and wev of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from sofit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kruled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 c/c including 4mm thick Non absetos desinger board in grid and applying three coats of white wash including preparation of surfaces.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store andd rubbish off the premises
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors/skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4 all as directed by Engr-in-Charge.
M&L Glazed ceramic tile 350 x 250 x 06-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement and sand mortar 1:4 all as directed by Engr-in-Charge.
Repair to balcony/Facia/parapet and soffit of chajjas etc by taking down old rendering 15 mm thick incl dubbing coat where required to match with the existing thickness in CM 1:4 and hacking clearly the edges and corners smooth and rounded for new plastered including formwork/scaffolding work upto height 3.5mtr above ground level of bldg complete all as specified.
diito all as per srl item No 57 above, but ht exc 3.5m but n.exc 7.0m
S & F 110mm bore PVC SWR Type B pipes ( pressure not less than 4 kg /cm2)single socket in vertcal length for Rain water with rubber joints fixed in wall etc all as specified and directed.
S & F in replairs PVC SWR Type B ( pressure not less than 4 kg /cm2) bends any radius 110 mm bore all as specified.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through existing PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed. One light point/fan /bell point controlled by one switch. Make of Cables : Havells, KEI,Anchor (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
All as per Srl Item No 62 here-in-above but one 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per Srl Item No 62 here-in-above but One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through existing PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for One 6 pin 16/6 amps power socket outlet point controlled by one 16 amps switch on independent board. Make of Cables Havells, KEI,Anchor (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
Supply & fixing modular type switch 16 Amps, single pole,1way,1 module,240V, ISI Marked Complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . Make : Indoasian glint, Crabtree, Anchor
Supply & fix fan regulator modular type electronic, stepped type(01 to 4/5), 100 to 120 Watts,240Volts,AC,ISI marked complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor
Supply & fix angle lamp holder with LED Bulb, insulated body with back plate for batten fittings complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor
Supply and fixing buzzer, ding dong AC, 230 volts single pole.
S & F modular bell push 6A , 1 module, 240V, ISI Marked Complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed Make : Indoasian glint, Crabtree, Anchor
Taking down unserviceable DBs and Supply and fixing in replacement of sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp bus bar including blanking plates where required . Make : Indoasian, Legrand, Schiender, Havells etc.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed Make -Indoasian part No- 811122 TO 811129 or its equivalent in Havells ,Legrand, L & T etc.
Supply & fix MCB SPN 63 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed. Make -Indoasian part No- 811151 or its equivalent in Havells ,Legrand, L & T etc.
Taking down unserviceable Sub main wiring and M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
S& F in replacement of Energy saving 10 Watt LED Bulk head luminaries, 230V, 50Hz with oval shape, surface mounted, comprising high brightness LEDs complete all as specifed and directed. Make- Havells, Cat part No RUGBYNEONFT10WLED760SSYMBOPC or its equivalent in Bajaj, Philips, Crompton Greaves etc.
Supply & Fixing LED light fitting 1x20W ,220v,AC decrotive box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
PACHNANDA BUILDERS
JR CONSTRSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .