Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC 13193 GALI NO 9 NAMDEV MARG BATHINDA | L1 | Accepted-AOC l1 | |
| 2 | l2₹15.0 L+₹2.0 L (15.1%)Rejected-AOC BATHINDA | l2 | Rejected-AOC l2 |
Tender Value
₹13.1 L
EMD Value
₹26,126
Closing Date
27 Sept 2024, 11:00 amClosed
Xen,Kandi Canal Stage2 Division,hoshiarpur
Xen,Kandi Canal Stage2 Division,hoshiarpur
Repair of Damaged Pojewal Distribution system off taking at RD 2150 m from riser of Pojewal Lift Irrigation Scheme off-taking at RD 112.526 Km left side of Kandi canal stage-II(Outlet 25 m AND 365 m)
2024_WR_119563_2
75
Open Tender
Civil Works - Canal
Item Rate
60 days
Hoshiarpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹26,126
Yes
19 Feb 2025
13 Aug 2024
27 Sept 2024
13 Aug 2024
27 Sept 2024
13 Aug 2024
WATER SUPPLY
(2) Excavation by mechanical means (JCB or Hydraulic excavation) in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.
((a)) Earth work upto 1.5 m. Depth
(28.2 (a)-ii) For Ordinary soil having gravel upto 40%
(27) Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
(B) Class PN-1.6 as per ISI
(28.27-B (c)) 150 mm / 160 mm i/d Sluice Valves flanged
(28.27 B (d)) 180 mm /200 mm i/d Sluice Valves flanged
(28.27 B (e)) 225 mm / 250 mm i/d Sluice Valves flanged
(10) Supplying and fixing of ISI Marked CI D-joint (complete with nut, bolts & rubber ring) as per IS:8794 for repair of pipe line including cutting , jointing and testing etc. but excluding cost of excavation complete.
(c) 150 mm /160 mm
(29) Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete.
((d)) C.I Single air valve screwed (Size 50mm)
(66) Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
(a) Size 0.6 m. x 0.6 m.
(b) Size 0.9 m. x 0.9 m.
Supply of Socketed for 160 mm dia uPVC pipe ISI mark confirming to ISI 4985(Premium make such as Supreme/Finolex/Jain etc) 2.5 kg/cm2 pressure
Supply of Socketed for 180 mm dia uPVC pipe ISI mark confirming to ISI 4985 (Premimum make such as Supreme/Finolex/Jain etc) 2.5 kg/cm2 pressure
Supply of Socketed for 200 mm dia uPVC pipe ISI mark confirming to ISI 4985 (Premimum make such as (Supreme/Finolex/Jain etc) 2.5 kg/cm2 pressure
Supply of Socketed for 225 mm dia UPVC pipe ISI mark confirming to ISI 4985 ( Premimum make such as Supreme/Finolex/Jain etc) 2.5kg/cm2 pressure
Supply and fixing for 160 mm dia. Alpha valve including carriage, rehandling, loading, unloading, testing etc. complete in all respects as per PWD specifications or instructions of the Engineer-in-charge.
Supply and fixing for 180 mm dia. Alpha valve including carriage, rehandling, loading, unloading, testing etc. complete in all respects as per PWD specifications or instructions of the Engineer-in-charge.
Supply and fixing for 200 mm dia. Alpha valve including carriage, rehandling, loading, unloading, testing etc. complete in all respects as per PWD specifications or instructions of the Engineer-in-charge.
Supply and fixing for 225 mm dia. Alpha valve including carriage, rehandling, loading, unloading, testing etc. complete in all respects as per PWD specifications or instructions of the Engineer-in-charge.
BRICK WORK
(11.7) First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
PLASTERING & POINTING
(15.9) 12.5 mm thick cement plaster 1:4
CONCRETE
(10.13) Cement concrete 1:2:4
(10-10.13-a(1)) mixing by manual means
STEEL AND IRON WORK
(18.18) Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing & fixing for 160 mm dia uPVC Bend (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing for 180 mm dia uPVC Bend (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing for 200 mm dia. uPVC Bend (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Providing & fixing for 225 mm dia. uPVC Bend (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
Supply and fixing of uPVC equal-Tee of 160 x 160 x 160 mm dia. 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC equal-Tee of 180 x 180 x 180 mm dia. 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC equal-Tee of 200 x 200 x 200 mm dia. 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC equal-Tee of 225 x 225 x 225 mm dia. 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC reducers/increase of 180 x 160 mm 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC reducers/increase of 200 x 160 mm 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC reducers/increase of 225 x 200 mm 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply and fixing of uPVC reducers/increase of 225 x 180 mm 6 kg/cm2 pressure conforming to IS-codes with latest amendments if any at site of work.
Supply fixing of 160 x 6 Kg mm flange tail end point with CI flange inculding carriage, rehandling, loading and unloading, testing etc. complete in all respects as per PWD specifications or instructions of Engineer-in-charge.
Supply fixing of 200 x 6 Kg mm flange tail end point with CI flange inculding carriage, rehandling, loading and unloading, testing etc. complete in all respects as per PWD specifications or instructions of Engineer-in-charge.
Supply fixing of 250 x 6 Kg mm flange tail end point with CI flange inculding carriage, rehandling, loading and unloading, testing etc. complete in all respects as per PWD specifications or instructions of Engineer-in-charge.
Supply and fixing socket for 160 mm dia. including carriage, re-handling, loading & unloading, testing etc. respect as per PWD specifications and instructions of the Engineer-in-Charge.
Supply and fixing socket for 180 mm dia. including carriage, re-handling, loading & unloading, testing etc. respect as per PWD specifications and instructions of the Engineer-in-Charge.
Supply and fixing socket for 200 mm dia. including carriage, re-handling, loading & unloading, testing etc. respect as per PWD specifications and instructions of the Engineer-in-Charge.
Supply and fixing socket for 225 mm dia. including carriage, re-handling, loading & unloading, testing etc. respect as per PWD specifications and instructions of the Engineer-in-Charge.
any other item
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .