| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹48.1 L+₹8.2 L (20.5%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.0 L+₹10.1 L (25.2%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.6 L+₹10.7 L (26.7%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹51.1 L+₹11.2 L (28.1%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,900
Closing Date
3 Jul 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF WATER SUPPLY PUMPING NETWORK PUMP MOTORS AND CERTAIN MISC WATER SUPPLY WORKS AT AF STN SULUR
2021_MES_451443_1
8411/E8
Open Tender
Miscellaneous Works
Item Rate
304 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,900
Yes
28 Jul 2021
14 Jun 2021
5 Jul 2021
14 Jun 2021
3 Jul 2021
28 Jun 2021
14 Jun 2021 - 26 Jun 2021
Amount
SCHEDULE A BOQ
M&L Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L PCC 1:1½:3 type A0 (using 12.5 mm graded stone aggregate) as in floors, finished even and smooth without using extra cement complete all as specified and directed
M&L Cutting, removing existing rusted and damaged hand rails with stand posts of OH tanks and material and Labour, fabricate, new Compound girders and stanchions, lattice girders, aerial masts, staging of water tank and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250), with square /round or any shape and sizes of MS pipe including two coats of synthetic enamel painting over a coat of red oxide, with scaffolding complete all as specified and directed.
M&L Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 150 mm dia GI/DI/MS pipes complete all as directed. Note:- a) Quoted rates are deemed to inclusive of cutting of joints in GI/DI/MS Pipes and preparation of new flanged sockets with jointing materials and refixing the pipe line after repairs at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
M&L Excavation for taking out broken CI/DI pipe line upto 200/150mm dia, cutting of CI/DI pipe line upto 200mm dia at two portion with the help of electrical driven pipe cutter and levelling the cutting face of pipe with the electric driven grinder and then CI/DI welding by electric welding machine, fixing detacheble joint, tail piece etc properly fixed the same pipe line on PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) foundation filling and mass concrete, returning filling of excavated materials including removal of surplus soil for making good complete all as specified.
M&L Opening of existing sluice valve of 200mm bore by dismantling from existing water line and opening of gland cover taking out with spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc and to refixing on the same line complete all as specified and directed Note: Any new parts like stainless steel Spindle with check nuts,Gland plate of required size shall be measured and paid separately under respective items
M&L Opening of existing sluice valve of 150mm bore by dismantling from existing water line for servicing and opening of gland cover for taking out unserviceable spindle with check nut of stainless steel & refixing the same after servicing, greasing including replacement of rubber packing, nuts & bolts, glands etc and to refixing on the same line complete all as specified and directed Note: New parts like stainless steel Spindle with check nuts,Gland plate of required size etc shall be measured and paid separately under respective items.However the qouted rate is inclusive of cost of labour for repairand refixing etc.
Supply only 200 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Supply only 150 mm bore stainless steel spindle with check nut, gland plate complete all as specified and directed.
Supply and fix CI foot valve 150mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.
M&L Taking down defective centrifugal pump set 60 HP to 83 HP capacity by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at same location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60 HP to 83 HP capacity motor pump as per manufacturer's design complete all as specified and as directed.
M&L Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150/200/ size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on cemented surfaces and one coat of synthetic paint on steel surfaces complete to make an operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers will be given as per requirement by the Engineer-in-Charge.
M&L Taking down defective centrifugal pump set 60 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately as supply only in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only Air cock grease nipple suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed..
Supply only water seal suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 60 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 60HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply and fix CI foot valve 100mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc including taking out old unserviceable one by dismantling suction pipe from pump set all as specified and directed.
Rectification of leakage of GI pipe diameter 80 to 100mm in trench after carry out excavation upto volume of 2 cum, replacement of unserviceable pipe fittings like collar, bend, Tee, Reducer, etc, including threading of existing pipe, including returning and filling after repairs for making good as per original and removal of surplus soil upto 50 mtr distance all as directed
S&F Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 200 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing unserviceable sluice Valve all as specified and as directed.
S&F Rotational moulded polythene water storage tank of 1000 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and pipe and fixed for 25 mm dia bore and including taking out unserviceable ball valves complete all as specified and directed.
S&F PVC water storage tank cover suitable for 500 to 1000 ltrs capacity tank with locking arrangement complete including taking down of existing one all as specified and directed
M&L Removing of accumulated earth over water supply mains of any width and depth up to 30 cm. including cleaning/cutting the grass and removing the grass waste to outside MD land complete all as specified and as directed. Note :- The unit rate quoted is deemed to be inclusive of following:- (a) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (b) Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled.
M&L Cleaning/ overhauling of squirrel cage induction motor by dismantling stator and rotor assembly, carryout necessary testing of windings to findout any core loss in windings, test of insulation resistance, etc. and applying of proper insulation material for strengthening of insulation, cleaning the casing and slots with wire brush, washing out dust and carbon particles with proper chemical solution, replacement unserviceable bearing, bush, carryout re-alignment of crank shaft re-assembling stator and rotor assemblies, testing complete all as specified and directed for capacity upto 60 HP. Note:- (i) Rewinding of stator and rotor if required will be measured and paid seperately. (ii) Cost of Transportation to and from the local workshop is deemed to be incl in the quoted rate.
M&L Rewinding of stator core with proper gauge and amount of highly insulated copper wire as per existing, testing complete.
M&L Rewinding of rotor core with proper gauge and amount of highly insulated copper wire as per existing, testing complete.
M&L Disconnecting electric connection and taking out submersible sewage cutter pump set of capacity 10 HP, 3 Phase, 415 volt from sewage well, transport to the workshop and back for making the serviceable/ repair, dismantle the motor/pump, taking out burnt winding of stator, removal of burnt insulation material from the slot, cleaning the stator slots and M&L for rewinding the stator using super enamelled, submersible grade copper winding wire of same gauge and turns, cleaning and overhauling the pump, tightening impeller complete including replacing the unserviceable spares, reinstall the pump in original position and testing at full load capacity all as specified and as directed by Engineer-in-Charge. Make : Kirlosker Location : Mehra Subway Note: Replacement of spares will be measured and paid separately as supply only but cost of labour element is deemed to be inclusive of the unit rate quoted.
Supply only Coil wound set with class "F" insulation
Supply only Mechanical seal lower
Supply only Mechanical seal upper
Supply only Ball Bearing Set
Supply only "O" Ring & gasket set
Supply only Fastner Set
Supply only Rotor rework with S.P Sleeve with balancing
Supply only Impeller with balancing work.
M&L Disconnecting the delivery pipe line of submersible pump sets of any capacity from water mains to take out by lifting column pipe of 50mm dia alongwith submersible cable and pump set from shallow well of any depth for servicing of submersible pump sets of any capacity at site, re-assembling the column pipe and re-connection of submersible cable with pump set and lowering in the shallow/open well, testing and commissioning all as specified and directed. Note:- (a) The cost of tools and equipments reqd for lifting/ lowering of pipes and pumps are deemed to be included in the quoted rate.
M&L Dismantling pump and motor of submersible pump set of capacity upto 10 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below as supply only. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only sleeve MS key for impeller
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 10 sq mm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make :- Havells, Polycab, Finolex
M&L Taking down defective centrifugal pump set 40 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : BATLIBOI Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case of services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed..
Supply only split casing gaskets suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 40 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 40HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L Cleaning of RCC Over Head Tanks of the following capacities by involving of the followings 09 (NINE) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge from RCC Over Head Tanks (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete (iv) Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Treatment of inside of tank which effective against all pathogens all complete. (vi) Sterilization of the tank atomosphere by UV radiation inside of the tank. (vii) Applying one coat of white wash internal surfaces. (viii) Replace nylon net for vent pipes & man hole cover (ix) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc
Note for item No 70 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted rate is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed off at out side MD land. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 500/- per day. (v) All safety with gadgets like safety Belts, special safety ladder, Helmets, Heavy Duty Gum Boots, Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.
(a)50000 gallon capacity 68 ft height at Siruvani Complex
(b)50000 gallon capacity 50 ft height at new KV, old KV and Mehra
(c)40000 gallon capacity 50 ft height at AKASH & MAP
(d)30000 gallon capacity 59 ft height at Amarvati Complex
(e)30000 gallon capacity 50 ft height at Kamal Park
(f)25000 gallon capacity 50 ft height at Technical area
(g)25000 gallon capacity 50 ft height at BRD HQ
(h)15000 gallon capacity 50 ft height MES key personal
M&L Cleaning/ overhauling of squirrel cage induction motor by dismantling stator and rotor assembly, carryout necessary testing of windings to findout any core loss in windings, test of insulation resistance, etc. and applying of proper insulation material for strengthening of insulation, cleaning the casing and slots with wire brush, washing out dust and carbon particles with proper chemical solution, replacement unserviceable bearing, bush, carryour re-alignment of crank shaft re-assembling stator and rotor assemblies, testing complete all as specified and directed for capacity 30 HP. Note:- (a) Rewinding of stator and rotor if required will be measured and paid seperately. (b) Cost of Transportation to and from the local workshop is deemed to be incl in the quoted rate.
M&L Rewinding of stator core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
M&L Rewinding of rotor core with proper gauge and amount of highly insulated copper wire as existing, testing complete.
S&F Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 150 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing unserviceable sluice valve all as specified and as directed.
M&L Construction of Valve Chamber of size 900 X 900 X 900 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 230 mm thick Brick work with fly ash bricks in Cement Mortar 1:6, 40 mm thick, PCC 1:2:4, Type B1, using 20mm graded aggregate in coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
M&L Rectification of existing defective flanged joints with rubber or fibre gasket complete with necessary nuts, bolts and washers for 100 mm dia GI/DI/MS pipes complete all as directed. Note:- a) quoted rates are inclusive of cutting of GI/DI/MS Pipes, jointing materials and preparation of new flanged sockets and refixing the same at existing place. (b) Necessary excavation shall be measured and paid separately under respective items of BOQ
S&F Rotational moulded polythene water storage tank of 500 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and pipe and fixed for 20 mm dia bore and including taking out unserviceable ball valves complete all as specified and directed.
Supply and lay UPVC pipe class “SCH 40” 100 mm dia, conforming to IS 13592 with all fittings (specials) and fixtures including disconnecting and taking out old unserviceable pipe with specials complete all as specified and directed.
Supply and fix UPVC butterfly valve of 100mm bore with all fixing accessories, gaskets nuts, bolts and washers and including disconnecting and taking out unserviceable valve complete all as specified and directed.
Supply and fix UPVC Non Return Valve (NRV) of 100mm dia with all fixing accessories, gaskets nuts, bolts and washers and including disconnecting and taking out unserviceable valve complete all as specified and directed.
M&L Disconnecting electric connection and taking out submersible sewage cutter pump set of capacity 7.5 HP, 3 Phase, 415 volt from sewage well, transport to the workshop and back for making the serviceable/ repair, dismantle the motor/pump, taking out burnt winding of stator, removal of burnt insulation material from the slot, cleaning the stator slots and M&L for rewinding the stator using super enamelled, submersible grade coper winding wire of same gauge and turns, cleaning and overhauling the pump, tightening impeller complete including replacing the following unserviceable spares, reinstall the pump in original position and testing at full load capacity all as specified and directed by Engineer-in-Charge. Make : Kirlosker Location : Old Kalpa Note: Replacement of spares will be measured and paid separately as supply only but cost of labour element is deemed to be inclusive of the unit rate quoted.
Supply only Coil wound set with class "F" insulation
Supply only Mechanical seal lower
Supply only Mechanical seal upper
Supply only Ball Bearing Set
Supply only "O" Ring & gasket set
Supply only Fastner Set
Supply only Rotor rework with S.P Sleeve with balancing
Supply only Impeller balancing work.
M&L Taking out silt, liquid water sludge in solid/semi solid state / pumping out all mud sewage water from collection sump of size 5 M dia and 8 mtrs depth /Manholes STP tanks of any capacity and size and removing the same using truck mounted honey sucker of capacity minimum 4 cum and to dispose off the sludge in low lying area at any distance during Sunday and holiday as per requirement, duly covered with earth over it and leaving the collection sump clean etc. complete all as specified and directed.
Note for item No 100 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level around collection sump. Useful material shall be stacked.
(ii) De-watering by high pressure submersible pump all complete.
(iii) Removal of sludge & sand from inside the tank scrubbing and washing side walls and bottom with bleaching powder solution and making surface free from any fungus, deposited stains using wire brush filling of cavities inside of tank with CM 1:2.
(iv) cleaning of walls , flooring and ceiling with special mechanized high pressure jet machines by high pressure jet pum 80-180 bar pressure , which dislodges the layer of dirt, algae, fungus stuck on its surface usage of scrubbing machines for old stains.
(v) Anti-Bacterial Treatment of Inside of the tank should be treated with specially developed 4 ft long ultraviolet Radiator to kill further floating bacteria/virus in order to make the tank totally clean, bacteria free and safe for storage of drinking water.
(vi) Cleaing/ above operations should be executed by trained workers and technicians.
(vii) Cost of T&P like rods, bamboos, gum shoes and hand gloves etc complete.
(viii) Driver and operator must be in possession of a valid licence and confirm the serviceability of the Truck.
(ix) Removal of blockage of sewage lines up to one metre from collection sump including manholes by using necessary tools/ mechanically tools or manually such as passing rope knots, bamboo kamti and disc of required size including safety measures such as test for gas etc. before flushing the pipe well with water after removal of blockage of pipe complete all as specified and directed.
(x) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 500/- per day.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in hard/dense soil and getting out for taking down/laying of pipes,valves etc
Returning, refilling including spreading levelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point
S&F Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" for 100mm bore with Socket and Spigot ends conforming to IS - 8329 in standard lengths suitable for Push-On Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating including taking down any description and any size of pipe complete all as specified and as directed. Note : Excavation earth work and DI special shall be measured separately.
M&L DI fittings Bend,(any type ,radius and angle) tapers any type (straight, bend,increasing,decreasing or double socket etc), Tee pieces, connection pieces, collers, caps and plugs complete all as specified and directed
M&L Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 116:- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil after cutting the existing road surfaces.
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land.
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 using 20 mm graded sone aggregates to make good existing road
M&L for excavation, earth work up to 1 Cum in any type of soil, cutting existing PCC plinth protection of 0.6 Cum for laying/ removing pipes and making good to the disturbed PCC as specified, dismantling existing water supply pipes of any type, re-routing the pipe as directed at site of work by using 3-Layer 32mm outer dia PPR pipe SDR 7.4 ( PN-16 @ 20°C) type connecting both ends to close the pipe line net work, testing during next supply hours of water distribution , complete all as specified and directed by Engr-in-charge. Note:- (i)3-Layer SDR 7.4 ( PN-16) type PP-R pipe 32mm outer dia and additional fittings required for the work will be measured seperately mentioned here-in-below as supply only. (ii) cost of Refixing of disturbed existing pipes on the wall including provision of new clamps are deemed to be included in the unit quoted rate. (iii) It will be the responsibility of the contractor to arrange all T&P required to execute the job and cost for same will be deemed to be included in the unit quoted rate.
Supply only 32mm outer dia 3 Layer PP-R Polyproplyne random copolymer pipe concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply fixing complete to walls, floors, ceilings, under trenches complete all as specified and directed. Make : SFMC, Prince, KPT
Supply only plain union for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only Reducer 63mmx32mm for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C). Make : SFMC, Prince, KPT
Supply only female threaded adaptor suitable for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only Elbow 90 degree for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only Male Threaded Adaptor for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only female threaded elbow suitable for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only female threaded union suitable for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C) of size 32 mm. Make : SFMC, Prince, KPT
Supply only reducing Tee 63mmx32mm for 3 Layer PP-R SDR 7.4 (PN 16 @ 20°C). Make : SFMC, Prince, KPT
M&L Re-winding of submersible motor by taking out burned copper winding stator, cleaning the casing and slots with wire brush and washing water and dirt with solution,and replace the unserviceable bearing bush,re alignment for crank shaft and winding and re-winding the motor with insulated copperwinding wire of existing gauge and making the winding leak proofing and taking out electric connection with suitable size of submersible copper cable up to 2 mtr long of capacity up to 7. 5 HP
M&L Servicing/ cleaning of water fountain consisting of submersible/ hollow well pump set 3 HP to 7.5 HP and connected accessories like pipe rings/ jets/ nozles/ suction and delivery pipes/ cable and electrical controlls, and any other efforts to make smooth flow of water through the pipes and nozles complete all as directed. Note :- (a) Replacement of unserviceable nozles upto 5 Nos, clamps, welding upto 12 stiches are deemed to be incl in the quoted rate. (b) Repair to the pumpset and replacement of cables will be measured and paid seperately under relevant items.
Taking down defective centrifugal pump set 30 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lath work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing capacity at least for 8 hrs on load, complete all as specified and as directed. (Supply of spare parts shall be measured and paid for separately under respective items here-in-after). Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 1000 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only split casing gaskets suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 30 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 30HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 30HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L Cleaning of RCC UG sumps of the following capacities by involving of the followings 09 (Nine) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure all complete (iv) Removing dirt and sludge by vaccum pump (v) Anti- Bacterial Tratment of inside of tank which is effective against all pathogens all complete. (vi) Sterilization of the tank atomosphere by UV radiation inside of the tank. (vii) Applying one coat of white wash internal surfaces. (viii) Replace nylon net for vent pipes & man hole cover (ix) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc
Note for item No 144 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted rate is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed off at out side MD land. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penality shall be imposed @ Rs 500/- per day.
(a)Semi underground sump of capacity two tank 200000 gallon capacity at KVPH (No 6)& Booster pump House at technical area.
(b)Semi underground sump of capacity two tank 150000 gallon capacity at KVPH (No 5)
(c)Semi underground sump of capacity 150000 gallon at KVPH.
(d)Semi underground sump capacity of 150000 gallon at KVPH two compartment (No 4)
(e)Semi underground sump of capacity two tank 80000 gallon each at booster pump house. Two compartment (No 2 & 3)
(f)Semi underground sump of capacity 50000 gallon at technical area.
(g)Semi underground sump of capacity two tank 20000 gallon capacity at KVPH (No 1)
(h)Semi underground sump of capacity two tank 20000 gallon at booster pump house at technical area.
(j)Semi underground sump of capacity 20000 gallon at technical area.
(k)Semi underground sump capacity of 10000 gallon single compartment at MES Key personal quarters.
(l)Underground sump of capacity 8800 gallon single compartment at sub way.
(m)Underground sump of capacity 500 gallon single compartment at old ATC bldg at technical area
M&L Arrangement of Chemical and bacteriological analysis of drinking water by collecting samples from different sources like UG sumps/ user end taps/ bore wells/ open wells etc located in 12 km periphery, collection of samples in sterrilized laboratory bottles/ canes, transportation to authorised Govt laboratory to deposit the samples in stipulated time, including payment of fees, collection and submit of reports to the Engineer-in-Charge complete all as directed.
Note for item No 158 :- (a) Cost of transportations for collection of sterrilized bottles from laboratory, deposition of collected samples in stipulated time, report collection after completion of tests, payment of fees to the laboratory for each sample, etc are deemed to be included in the quoted rate. (b) The rate quoted is considered to be for each sample. (c) Sample from different sources to be taken as per time schedule directed by Engineer-in-Charge throughout the currency of the contract. (d) Payment will be made after submission of report from authorised Govt laboratroy only.
M&L Flat Three Core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 sq mm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make : Havells/ Polycab/ Finolex
M&L DOL starter suitable for upto 5 HP, single phase 240V, 10-40 Amps motor pumping set including replacing the unserviceable wiring kit complete including taking down existing one all as specified and directed. Make : L&T, C&S, BCH, Havells
M&L Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, suitable for 100 mm dia pipes, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing unserviceable sluice valve all as specified and as directed.
M&L Construction of Valve Chamber of size 600mmx 600mmx 600mm (internal) internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded stone aggregate for foundation, 200 mm thick Brickwork with fly ash bricks using modular bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
S&F 90 mm outer dia of pipe of 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings fixing complete to walls, floors, ceilings, under trenches including taking down of existing GI/CI unserviceable pipes complete all as specified and directed. Make : SFMC, Reliance Industries, KPT.
Note for item No 164 :- (a) The unit rate shall include for taking down existing pipe and connections and all fittings as directed.
(b) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
S&F 90 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Supply only 90 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete
Servicing/ cleaning of water fountain consisting of submersible/ hollow well pump set up to 1 HP and connected accessories like pipe rings/ jets/ nozzles/ suction and delivery pipes/ cable and electrical controlls, and any other efforts to make smooth flow of water through the pipes and nozles complete all as directed. Note :- (a) Replacement of unserviceable nozzles upto 5 Nos, clamps, welding upto 12 stiches are deemed to be incl in the quoted rate. (b) Repair to the pumpset and replacement of cables will be measured and paid seperately under relevant items.
M&L Dismantling pump and motor of submersible pump set for capacity upto 7.5 HP to carry out repairs and replacements at local workshop, duly replacing worn out parts, applying one coat of spray painting with synthetic enamel paint of existing colour and testing complete all as specified and directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be included in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only GM Bush.
Supply only sleeve MS key for impeller
Supply only SS coupling bearing.
Supply only oil seal thrust bearing.
Supply only Sand Guard.
S&F 63 mm outer dia of pipe of 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings fixing complete to walls, floors, ceilings, under trenches including taking down of existing GI/CI unserviceable pipes complete all as specified and directed. Make : SFMC, Reliance Industries, KPT.
Note for item No 177 :- (a) The unit rate shall be include for taking down existing pipe and connections and all fittings as directed.
(b) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(c ) Wall thickness of pipes shall be all as per IS : 15801
S&F 63 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes and including taking out unserviceable Gate valves complete all as specified and directed.
Supply only 63 mm outer diameter of pipes in cutting road portion 3 Layer PP-R Polyproplyne random copolymer concealed SDR 7.4 (PN 16 @ 20°C) UV stabilized and antimicrobial fusion welded havIng thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropyelene random fittings complete
Taking down defective centrifugal pump set 20 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Make of Pump : M/s B E Pvt Ltd/ Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 20HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 20HP motor pump as per manufacturer's design complete all as specified and as directed.
Taking down defective centrifugal pump set 10 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 10 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 10HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L Rising/down pipe of 150mm DI pipe, K-9 with flanges for fixing as rising/ down/wash out pipes for over head water reservoir upto 18mtr elevation including arragement of scaffolding and other lifting equipments, repairs to damaged surfaces to match with existing specifications and removal of old corroded pipes complete all as specified and directed.
M&L Making arrangement to flush out the existing pipe line of any type upto 50mm bore and upto 100m length, applying 4.5 N/sqmm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
M&L Making arrangement to flush out the existing pipe line of any type 63 to 100 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
M&L Making arrangement to flush out the existing pipe line of any type 110 to 150mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
M&L Making arrangement to flush out the existing pipe line of any type 160 to 200 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 202 to 205 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This will be inclusive in quoted rate. (ii) Excavation and earth work required will be measured and paid seperately. (iii) The flushing out will be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This will be inclusive in quoted rate.
PRIYA ENTERPRISES
SARASWATHI CONSTRUCTION
T C KARUNANITHI
pk janardhanan
Neptune Engineers and Builders
kaarthic builders
p.chinnasamy
KUMAR AGENCIES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .