| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹77.9 L+₹1.5 L (1.96%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110 075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 3 | L3₹82.7 L+₹6.3 L (8.21%)Rejected-Finance RZ9 7 GALI NO 2 KAILASH PURI PALAM NEW DELHI 110045 | NEW DELHI | NEW DELHI | DELHI | 110045 | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 4 | L4₹84.7 L+₹8.3 L (10.9%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-Finance QUOTED AMOUNT NOT LOWEST | |
| 5 | L5₹86.6 L+₹10.3 L (13.4%)Rejected-Finance | L5 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
2 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DELHI CANTT
HQ CWE DELHI CANTT DELHI 110010
SPL REPAIR OF BLDG NO T1 T3 AND T5 OF 505 ABW UNDER GE NORTH DELHI CANTT 10
2024_MES_644688_1
CWE/D-42/2023-24
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
As per NIT
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹2.0 L
Yes
4 Jun 2024
1 Mar 2024
3 Apr 2024
1 Mar 2024
2 Apr 2024
26 Mar 2024
Amount
Demolition of brick work built in cement mortar complete all as specified and directed.
M & L Brickwork with subclass 'B' Brick straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:6 complete at any position all as specified.
M & L Brickwork with subclass 'B' Brick straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:4 complete all as specified.
Ditto- but except brick (brick used obtained from demolition) complete.
Demolition of cement concrete (unreinforced) of any descriptioin and in any position not other wise specifically provided complete.
M&L for Plain Cement Concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in foundation filling and mass concrete.
M&L for cement concrete type B-2 1:2:4 (using 20mm graded stone aggregate as in surface channels and drains.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Reinforced cement concrete 1:2 :4 type B-1 using 20 mm graded stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete (reinforcement to be measured separately).
Demolition cement concrete (un reinforced) in ground floor and packing n exc 15 cm thickness (below or above ground level) all as specified
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n exc 1.5 each.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area exc 1.5 but n. exc 4.00 Sqm each and removing from site.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) pr omsi;atopm bpards/slabs/blankets, any thickness, inclusing cover fillets
Dismantling framed work timber scantling under.40 Sqcm in section in fillets,rails, posts, rafters or in any position all as specified and directed.
Dismantling framed work timber scantlings 40 Sqcm and over in section and at any position as in roof truss, purline etc all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings. (corrugated, semicorrugated, etc.) sheets in roof coverings including ridge pieces.
Taking down shutters of any description n exc 1 sqm each from the existing frame.
Taking down shutters of any description exc 1 sqm but n. exc 2.00 each from the existing frame
Taking down shutters of any description n exc 1 sqm each and refixing in same opening after easing adjusting or fixing glass, wiremesh etc. (Note - consumable items to be measured separately).
Taking down shutters of any description exc 1 sqm but n. exc 2.00 each and refixing in same opening after easing adjusting or fixing glass, wiremesh etc. (Note - consumable items to be measured separately).
S&F Pre-painted galvalume aluminum zink coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Pre-painted galvalume aluminum zink coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F Steel work in tubular trusses, Rafters and purlins including special shaped washer etc. complete using washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
Providing and fixing false ceiling with semi perforated 12mm thick micro tegular edged at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture, design and pattern having moisture content less than 2% humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 475 (part-4) -1970 and light Code Description unit rate No 429 Sub Head:26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams over sqm including boh sides) comprising of main-T runners of size 15x32mm of length 3000mm, cross T of size 15x32 of length 1200mm and secondry intermediate cross T of size 15x32 of length 600 mm to form grid module of size 600x600mm suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm, Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall/ partition with the help of plastic rawl pluhs at 450mm centre to centre and 40mm long dry wall screws, The work shall be carried out as per specification drawing and as per direction of the Engineer-in-Charge.
S & F second class hard wood Plain, solid, straight chowkats and frames, wrought, ramed rebated on the solid, rounded or chamfered, rafter, purline etc put together with glue pinned at joints,
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in hold fasts, fixing of truss on wall including necessary use and waste of form work complete.
S&F mild steel work as in holdfast made out of flat iron 25 mm x 5 mm including necessary welding or fixing nuts and bolts complete.
S&F Second class hard wood Glazed and skeleton shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) all as specified and directed.
S & F Roll Forming GI ECO 4000 series double shutter (glazed shutter and mesh shutters) galvanized steel windows and ventilators with guard bars, fabricated from roll formed sections made galvanized steel colour coated/powder coated sections including 4mm thick plain glass pan in glazing for glazed shutter and stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm complete for mesh shutters, including two coat of synthetic enamel paint over a coat of red oxide on steel guard bar , all fitting and fixtures all as specified.
Supply and fixed to chowkats 2nd class hard wood factory made Plain, framed, panelled door shutters 40mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers and framing is moulded on solid (for each side)
S&F to door shutters 300 mm long mild steel sliding door bolts plate type) stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and
S&F butt hinges 100mm long heavy weight, cold rolled mild steel and fixed to door shutters
S&F 200 mm long mild steel barrel tower bolts of stove enamelled black with bright bolt and fixed to door shuttersextruded section and fixed
S&F aluminium handles 150 mm size cast type, anodised complete
S&F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete.
Dismantling floor, wall and hearth tiling including cement mortar bedding ,removing serviceable tiles to store and rubbish off the premises.
M&L for plain cement concrete 25mm thick type B-0 1:2:4 (12.5mm graded stone aggregate) as preparation of surface and prepare the surface to received floor tiles.
M & L for joint free non skid ceramic tiles 7-8mm thick (square/rectangular) area of each tiles exc 0.18 sqm but n exc 0.36 Sqm, in floors etc set and jointed in neat cement slurry & pointed in white or colour cement to match the surfaces over 15mm thick screed bed in cement mortar 1:6 all as specified and directed.
Ditto but in vertical surfaces as in skirting/dados with backing coat 10 mm thick cement mortar 1:4 all as specifed and directed
Cleaning all the dust and loose material or any treatment by brush/blower/Grinder including removing of vegetation/plantation from the surface and exposed RCC Roof top surface. M&L for preparation of roof top surfaces, providing and applying single component elastic cold applied polyurethane modified acrylilc roofing system, co elastic technology (CET) based on modified polyurethane and fully fibre reinforced, having Sun Reflectivity index (SR) of 109 on tip of concrete roof surfaces, All cracks up to 3mm at corner joints, channel and parapets should be treated with crack seal. Applying three coats including one coat of primer of shaliUrethane BTD/Sikalastic 560/smart care damp proof ultra having coverage @ min 0.75kg/m2 and diluting up to 10% and laying reinforced fiber net and applying two coats (without dilution) of shaliUrethane BTD/sikalastic 560/smart care damp proof ultra @ total consumption 2 kg/m2 in two coats for maintaining minimum dry film thickness 1.5mm and elongation at break of free film of approx 350% . The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge/Consultant (Note:6 Hrs interval between two coat will be maintained). All auxiliary and accessories involved during application should be supplied by single. (Make - STP/Sika/Asian paint or equivalent as approved by GE). Note - Application of water proofing treatment will be done by Authorised Applicator only. (i) The water proofing treatment shall be carried out by the manufacturer or their authorized applicators duly approved by GE in writing. (ii) 5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractors risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor's quoted rates for this item shall deemed to be inclusive of this aspect.
(a) The rates including Material & Application:- (b) Delivery : Freight Extra on Material, As Applicable from Gaziabad Godown. (c) Payment Terms : Material Payment 100% Advance against PI. Application Payment will be on Mutual understanding of Applicator & Contractor Warranty letter will be provided by Applicator to contractor. (d) Scaffolding, Electricity & Store to be provided by Customer on FOC at site.
Demolition of cement concrete (reinforced) in gound floors and pavings not exc. 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for providing precast cement concrete in 1:2:4, type B1 using 20 mm graded stone aggregate in landings, cover slabs chullah hoods, chajjas, water troughs including necessary form work and set in CM 1:4 complete all as specified and directed.
M & L for Mild steel TMT bars 10 mm dia and over, cut to length, bent ot shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips
M&L glazed ceramic coloured tiles in vertical surface 450x350x7 or 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl rendering 10mm thick in CM (1:4) and finished rough, complete all as specified & directed.
Demolition/dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar
M&L 20 to 25 mm thick machine cut pre-polished kota stone slab as in flooring over and including 15mm thick screed bed in cement mortar 1:6, laid over cement slurry @ 3 Kg/Sqm and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge of slab complete all as specified and as directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above).
M&L 20 to 25 mm thick machine cut Kota stone slab polishing/diamond polishing by machnical means and using carborandum stone of 0 unit to achive mirror finished surface as in riser or vertical surface over and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge where as specified and as directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size as in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above).
S&F Solid PVC molded door frame of size 50mm x 95mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC Sheet suppling & fixing in opening as per specification & drawing.
Factory Made Solid PVC Moulded Door Shutter with partical board, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing in SSR
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site.
All as per Ser No above but 20 mm dia bore.
All as per Ser No above but 25 mm dia bore.
M&L for 15mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
Ditto but 20 mm bore.
Ditto but 25 mm bore.
Cutting chases pinning in making good to facing where required for concealed water tubing and making good cutting not exc 10cm girth in brick walls complete.
S&F in repair bib taps 15mm bore, long body bib cock with wall flange, fancy type, brass chromium plated with quarter / half turn screwed for iron pipe or for brass ferrule including all accessories complete all as specified and directed.
M & L in repair 15mm Stop valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed
M & L in repair 15mm angle cock, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed
S&F in repair fancy type brass chromium plated shower rose with arm complete
S & F in repair 25 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete.
S & F in repair 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete.
S&F in repair Brass chromium plated tubular towel rail 20mm dia fixed with screw to wall complete
S&F in repair vitreous chaina squatting pan Orissa pattern size 580x440mm white with integral foot rests, trap etc (Excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F vitreous china urinals half stall bowl, flat back large of size 420x395x635 mm white with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement complete all as specified.
S&F in repair Sheet Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long.
S&F in repair only PVC Flushing cistern 10 ltr capacity with inlet ball valve float and handle and 32mm bore flush pipe including bracket complete.
S & F in repair PVC connection 15 mm bore, 600 mm long complete with both ends unions.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore including excavation and demolition/taking down PVC/CI drain/sewage/Rain water pipe complete.
S&F PVC (SWR) bends any radius, 75 mm bore, complete.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate mix with WPC complete all as specified and as directed.
S&F PVC (SWR) bends any radius, 110 mm bore, complete.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, ISI marked, double alyered hoisted and fixed in position including connecting up pipes including dismantling of PVC water tanks complete.
S&F in repair vitreous china wash basin, snow white of size 440x525x195mm oval shape including brackets including cutting for and pinning in ends of brackets in CM 1:3 including 32mm dia chromium plated waste coupling complete all as specified and directed.
S&F in repair WHB mixer to mix Hot & cold water, cast copper alloy, with half/quarter turn swan neck, fancy type, chromium plated, screwed down high pressure, long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete.
M&L for 18-20mm thick granite (of any type) stone slab work (table rubbed and polished) as wash hand basin laid over and including 15 mm thick screed bed in cement mortar 1:6, set in white cement with pigment and pointed in white cement 1:2 using marble dust with admixture of pigment to match with shade including cutting granite slab circular or oval shape for fixing of vitreous china wash hand basin of desired size and shape including rubbing and polishing and making sandwitch moulding to edges complete all as specified and directed. Note - Breakage if any in granite slab will be born by the contractor).
M&L for two coats of synthetic enamel paint on old steel surfaces , over 10 cm in width or grith not other wise described complete.
S&F in repair vitreous china urinal partition white of size 310 x 770mm complete all as specified and directed.
Taking down cement plaster including raking out joints hacking for key scrubbing down with water complete.
Removing old cement wash or any treatment , hacking for key, racking out joints of old brick work or stone work built in cement mortar, not previously plastered : and scrubing down with water etc to receive plaster all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 over brick or concrete surfaces finishing the surfaces fair and even without using extra cement. (Note-approved stone dust to be used instead of river sand)
M&L for rendering 15 mm thick in CM 1:6 over brick or concrete surfaces finishing the surfaces fair and even without using extra cement. (Note-approved stone dust to be used instead of river sand)
M&L for rendering 5 mm thick in CM 1:3 as in ceilling surfaces finishing the surfaces fair and even without using extra cement. (Note-approved stone dust to be used instead of river sand)
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of priming with chalk whiting, on plastered surfaces preparatory to distempering complete.
M&L for preparation of new plastered surfaces of wall and applying two coat of distemper oil emulsion over a coat of priming chalk whiting on plastered surfaces preparatory to distempering.
M&L for Preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete.
S&F in repair 4 mm thick sheet glass ordinary quality in squares n.exc. 0.50 sqm in each pane fixed with oil putty or wooden beading.
S & F, Stainless steel, wire cloth 0.36 mm nominal dia of wire, and average width of aperature 1.40mm and fixed with stainless steel wire stapples complete all as specified.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in subase of floor, including necessay form work complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation.
M&L for 60mm thick M-35 grade factory made rubber moulded coloured machine pressed precast concrete interlocking paver block in approved design and colour, conforming to IS-15658-2006 with grey cement and pigment as approved laid over and including 25mm thick sand cushion and joints filled with sand complete all as specified and directed. (Note - sand measured and paid seperatly).
S&F for factory made kerb stone of M-25 grade precast cement concrete/stone laid in position to the required line, level and curvature, jointed with cement mortor 1:3 including making the joint with or without grooves including making drainage opening where ever required complete as per direction of Engineer-in-Charge Note (i) Length of finished kerb edging shall be measured for payment (ii) precast CC kerb shall be approved by the Engineer-in-Charge.)
M&L for painting of two coats synthetic enemal paint over kerb stone in white/yellow/black shades including priming coat and cleaning/preparation of the surface laid as per design approved by Engineer-in-Charge
M&L cement concrete type C-1, 1:3:6 (using 20mm graded aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair without using extra cement incl making joints at every 2.5m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight including necessary form work and complete all as specified.
M & L for preparation of new wooden surfaces and applying two coats of synthetic enamel paint of any description over 10 cm width or girth over a coat of pink primer complete.
M & L for preparation of old wooden surfaces rubbing with sand paper and applying two coats of synthetic enamel paint of any description over 10 cm width or girth.
S&F plates Fe-290 (Gde E-165) (plain or chequered) channels, square cut or notched (Ordinary and counter sunk) forming holes, without any attachment.
Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long of dia exc 12mm n exc 20mm dia for fixing of truss on wall in concrete all as specified and directed.
M&L for preparation of new steel untreated surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel (ordinary tint) over a coat of Red oxide zinc chrome all as specified and directed.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete
Material & labour for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and metal flush box, etcand making good to the disturbed surfaces to match the existing complete all as specified and directed for for One light / bell point controlled by one, one way switch 06 Amps
All as per above item here-in-before but one Ceiling / exhaust fan point controlled by one, one way switch 5/6 Amps
All as per above item here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per above item here-in-before but one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch
All as per above item above here-in-before but with point wiring 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board and independent MCB complete all as specified and directed
S&F of switch piano flush type, 06 Amps, single pole, one way, 230 volts complete
S&F of switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete
S&F of socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete
S&F of socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete
S&F of ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, humfree, AC, 230 volts, 100 watts complete
S&F of ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F of lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulb complete.
S&F in replacement of surface mounting LED integrated aluminium housing batten luminaire not less than 20 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete.
S&F in replacement of surface mounting LED integrated aluminium housing batten luminaire not less than 8/10 watt 2 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete.
S&F in replacement of surface mounted LED building security light fitting in high pressure die cast aluminium housing not less than 35 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core complete all as specified and as directed.
Supply and fixing in replacement of exhaust fan, steel body, AC, single phase, 230 V of size 300mm sweep with blades, frame & louver having 1400 RPM speed, 1600 CMH and including making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces to match the existing complete all as specified and as directed.
M&L for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed, including taking down old sub main wiring complete
S&F (in replacement) sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and sheet metal enclosure double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 Amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Note :- MCCB & MCB SP will be measured seperately)
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning by using suitable copper lugs complete:-
(a) SP 5 To 32 AMP
(b) SPN 40 to 63 AMP
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete.(Note: On testing after completion if the desired earth resistance upto 5 ohm is not obtained the earthing will be redone at no extra cost.)
The new hut furnitures
Adhunik Builders
VED PRAKASH ARORA
M/S Yamin
imran construction company
M/S ANIL KUMAR
CHOPRA BUILDERS
GIAN ENGINEERS
G and G Infratech Private Limited
Mohit Infratech
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .